Laserfiche WebLink
NUMBER <br />FROM <br />TO <br />SIZE <br />POWER <br />CONTROL <br />SIGNAL <br />COMMENTS <br />C-001 <br />CONTROL PANEL <br />PUMP 1 STARTER <br />3/4" <br />4414, 1#14G <br />C-002 <br />CONTROL PANEL <br />PUMP 2 STARTER <br />3/4" <br />4414, 1#14G <br />C-003 <br />CONTROL PANEL <br />STILLING BASIN SAMPLER 2 <br />1" <br />2414, 1#14G <br />C-004 <br />CONTROL PANEL <br />(F) SDMH 1-4 SAMPLER <br />1" <br />VIA J -P3, JB-P4 <br />C-005 <br />CONTROL PANEL <br />SDMH 1-3 SAMPLER <br />1" <br />2414, 1#14G <br />VIA JB-P3, JB-P4 <br />C-006 <br />CONTROL PANEL <br />(F) FSMH 2-2 SAMPLER <br />1" <br />2414, 1#14G <br />VIA J -P3, JD=P4 <br />C-007 <br />CONTROL PANEL <br />(E) STILLING BASIN SAMPLER <br />1" <br />2414, 1#14G <br />P-001 <br />EXISTING PANEL XS4VO2-2-(40-09) <br />XS4VO2-2-1 (40-03) <br />2" <br />342, 146G <br />VIA J -P1, JB-P2, JB-P3 <br />P-002 <br />STUB UP NEAR XS4VO2-2-(40-09) <br />JB-P3 <br />2" <br />SPARE <br />VIA JB-P1, JD-P2 <br />P-003 <br />STUB UP NEAR XS4VO2-2-(40-09) <br />JB-P3 <br />2" <br />SPARE <br />VIA JB-P1, J -P2 <br />P-004 <br />XS4VO2-2-1 (40-03) <br />XFMR <br />1" <br />343, 1-#1OG <br />P-005 <br />XS2VO2-2-1 (40-03) <br />CONTROL PANEL <br />111 <br />2412, 1-#12G <br />P=006 <br />XS2VO2-2-1 (40-03) <br />FSMH 2-2 SAMPLER <br />1" <br />2410, 1-#10G <br />VIA J -P3 <br />P-007 <br />XS VO2-2-1 (40-03) <br />UPSTREAM VALVE DISC SW <br />1" <br />3412, 1- 12G <br />P-003 <br />UPSTREAM VALVE DISC SW <br />UPSTREAM VALVE <br />1" <br />3412, 1-#12G <br />P-009 <br />XFMR <br />XS2VO2.2-1 (40-03) <br />211 <br />446, 1-#3G <br />P-010 <br />XS4VO2-2-1 (40-06) <br />SITE LIGHTING <br />1" <br />2412, 1- 12G <br />VIA J -P3 <br />P-011 <br />XS2VO2-2-1 (0-03) <br />RECEPTACLES <br />1" <br />2412, 1-#12G <br />VIA J - 3 <br />P-012 <br />XS2VO2-2-1 (0-03) <br />FIT F-1 <br />1" <br />2412, 1-#12G <br />VIA -P3 <br />P-013 <br />XS2VO2-2-1 (40-03) <br />(F) SDMH 1-4 SAMPLER <br />1"" <br />VIA JB-P3, JB-P4 <br />P-014 <br />XS2VO2-2-1 (40-06) <br />SDMH 1-3 SAMPLER <br />1"' <br />2410, 1410G <br />VIA JB-P3, J -P4 <br />P-015 <br />XS2VO2-2-1 (40-03) <br />STILLING BASIN SAMPLER 2 <br />1" <br />2410, 1-#10G <br />VIA J -P3 <br />P-016 <br />XS2VO2-2-1 (40-06) <br />FIT F-2 <br />1" <br />2412, 1-412G <br />VIA JB-P3 <br />P-017 <br />XS4VO2-2.1 (40-06) <br />EX-DBRISER-GATE DISC SW <br />1°' <br />3412, 1-#12G <br />VIA J -P3 <br />P-013 <br />EX-D RISER -GATE DISC SW <br />EX-D RISER -GATE <br />1" <br />3412, 1412G <br />P-019 <br />XS4VO2-2-1 (40-03) <br />PUMP 1 STARTER <br />3/4" <br />3412, 1412G <br />P-020 <br />XS4VO2-2-1 (40-06) <br />PUMP 2 STARTER <br />3/4" <br />3412, 1-#12G <br />P-021 <br />PUMP 1 STARTER <br />PUMP 1 <br />3/4" <br />3412, 1-#12G <br />P-022 <br />PUMP 2 STARTER <br />PUMP 2 <br />3/4" <br />3412, 1-#12G <br />P-023 <br />JB-P3 <br />JD-P4 <br />1" <br />SPARE <br />P-024 <br />JB=P3 <br />JB=P4 <br />1" <br />SPARE <br />P-025 <br />XS2VO2-2-1 (40-03) <br />JB-P3 <br />1" <br />SPARE <br />P-026 <br />XS2VO2-2-1 (40-06) <br />J -P3 <br />1" <br />SPARE <br />P-027 <br />XS4VO2-2-1 (40-06) <br />HEATER DISCONNECT SWITCH <br />3/4" <br />3412, 1-#12G <br />P-023 <br />HEATER DISCONNECT SWITCH <br />HEATER <br />3/4" <br />3412, 1-#12 <br />P-029 <br />XS2VO2-2-1 (40-06) <br />EXHAUST FAN DISCONNECT SWITCH <br />3/4" <br />2412, 1412G <br />P-030 <br />EXHAUST FAN DISCONNECT SWITCH <br />EXHAUST FAN <br />3/4" <br />2412, 1412G <br />P-031 <br />XS2VO2-2-1 (40-06) <br />40-03 BUILDING LIGHTING <br />3/4" <br />2412, 1-#12 <br />P-032 <br />XS2V02-2A (40-03) <br />40-03 BUILDING RECEPTACLES <br />3/4' <br />2412, 1412G <br />S-001 <br />(E) HONEYWELL PANEL <br />CONTROL PANEL <br />1" <br />1/C#16(SH), NETWORK CABLE <br />VIA JB-S1, JD=S2, JB=S 9 COORDINATE WITH HONEYWELL FOR NETWORK CABLE TYPE <br />S-002 <br />STUB UP NEAR (E) HONEYWELL PANEL <br />JB-S3 <br />1" <br />2/C#16(SH) <br />S-003 <br />STUB UP NEAR (E) HONEYWELL PANEL <br />JB=S3 <br />1" <br />2/C#1 (SH) <br />S-004 <br />EX-D RISER=GATE <br />CONTROL PANEL <br />1" <br />2-2/C 16(SH) <br />S-005 <br />UPSTREAM VALVE <br />CONTROL PANEL <br />1" <br />2-2/C#16(SH) <br />S-006 <br />FIT F-1 <br />CONTROL PANEL <br />1" <br />2/C#16(SH) <br />VIA J -S3 <br />S-007 <br />(F) SDMH 1-4 SAMPLER <br />CONTROL PANEL <br />1" <br />VIA J -S3, J -S4 <br />S-003 <br />SDMH 1-3 SAMPLER <br />CONTROL PANEL <br />1" <br />2/C#16(SH) <br />VIA J -S3, JB-S4 <br />S-009 <br />LT L-3 <br />CONTROL PANEL <br />1" <br />2/C16(SH) <br />VIA J-S3, JB-S4 <br />S-010 <br />STILLING BASIN SAMPLER 2 <br />CONTROL PANEL <br />1" <br />2/C#16(SH) <br />S-011 <br />LT L-2 <br />CONTROL PANEL <br />1" <br />2/C16(SH) <br />VIA JB-S3, JD=S4 <br />S-012 <br />FIT F-2 <br />CONTROL PANEL <br />1" <br />2/C#1(SH) <br />S-013 <br />LT L-1 <br />CONTROL PANEL <br />1" <br />2/C#16(SH) <br />S-014 <br />(E) SAMPLER <br />CONTROL PANEL <br />1" <br />2/C 16(SH) <br />S-015 <br />(E) GV-1 <br />CONTROL PANEL <br />1" <br />2-2/C#16(SH) <br />S-016 <br />CONTROL PANEL <br />(F) FSMH 2-2 SAMPLER <br />1°° <br />2/C#16(SH) <br />VIA J - 3 <br />S-017 <br />(E) LT-4 <br />CONTROL PANEL <br />11° <br />2/C16(SH) <br />S-013 <br />LT-5 <br />CONTROL PANEL <br />1" <br />2/C 16(SH) <br />VIA J -S3, JP-S4 <br />S-019 <br />LT-6 <br />CONTROL PANEL <br />1" <br />2/C#16(SH) <br />VIA J -S3, J -S4 <br />S-020 <br />CONTROL PANEL <br />J-S3 <br />1" <br />SPARE <br />S-021 <br />CONTROL PANEL <br />JB-S3 <br />1" <br />SPARE <br />S-022 <br />JB=S3 <br />JB=S4 <br />1" <br />SPARE <br />S-023 <br />JB=S3 <br />J -S4 <br />1 °° <br />SPARE <br />S-024 <br />CONTROL PANEL <br />(E) LT <br />sym <br />I REVISION <br />ICY <br />APPROVED <br />DATE <br />sYm <br />®® <br />DOEING EVERT SITE STORMWATER UPGRADE <br />25065486 <br />KJ <br />ZOD <br />0105e21 <br />REMSION <br />13Y <br />APPRMD <br />DATE <br />ACCEPTABILITY <br />Meiia <br />03.05.21 <br />�� ffnnE <br />THIS DESIGNAND/OR <br />SPECIFICATION IS APPROVED <br />CHECKED <br />J. Mohr <br />03.05.21 <br />PROVED BY <br />DEPT. <br />DATE <br />UNCREER- <br />Z. Devlin <br />03.05.41 <br />ME <br />ZAPPROVED- <br />HECK D <br />. 21 <br />ELECTRICAL <br />