Laserfiche WebLink
PARTITION. SEE WALL <br />TYPE ON PLAN <br />518" TYP X GYP E <br />1/4" METAL COVE <br />STRIP OR 1" TRI <br />1/4" HARDIBACKE <br />WALLS. NOT RE( <br />PLYWOOD WAIN; <br />EPDXY FLOORIN <br />SYSTEM WITH SI <br />RADIUSED COVE <br />EXTERIOR <br />SEE WALL TYF <br />SCALE: 3"=l'-0" 1A10-14 A540 <br />i ill Pill <br />ff <br />06 WIN <br />SCALE: 3"=1'-0" A65 A540 <br />SCALE: 1-1/2"4 0" <br />ACKER ROD AND ACOUSTIC <br />SEALANT <br />HROUGH PENETRATION <br />OXULACOUSTIC INSULATION <br />A540 <br />FIR SEALANT <br />1-5/81" MTL S <br />CLIP ANGLE <br />SCALE. 1-1/74-0" <br />EXTERIOR CONT. URETHANE SEALANT AROUND <br />ALL EDGES OF FLASHING <br />TOP AND BOTTOM COVER PLATE <br />ASSEMBLY - RIVET OR SCREW TO <br />SIDING PANEL TOP (BOTTOM) AND <br />SIDES OF PLATES -- <br />1" MIN OVERLAP <br />F_ <br />PIPE WHERE OCCUR , <br />SEE A65 <br />CONT. URETHANE SEALANT <br />3/8" MIN. FILLET AROUND PIPE <br />INSULATED -CORE <br />METAL WALL PANELS <br />GUARDRAIL SEE STRUCTURAL <br />)EFLECTION TRACK <br />1 LAYER 5/8" TYPE X GWB <br />EA SIDE <br />31/2" (R-10) BATT INSULATION <br />INTERIOR <br />PANEL CUTOUT (112" MINMUM <br />CLEARANCE AROUND PENETRANT) <br />HSS WHERE OCCURS, <br />SEE A65. <br />EXPANDABLE FOAM <br />y1 <br />SCALE: 3"=1'4' A65 A540 <br />SCALE: 1-1/2"44' <br />STUD BLOCKING <br />6 PCF MINERAL WOOL PACKING <br />1-114"" THICK FIRE RATED <br />SEALANT OVERLAP <br />ONE OR MORE PIPE OR CONDUIT <br />SEE UL <br />tt---------------- <br />d <br />EXTERIOR CONT. URETHANE SEALANT AROUND <br />ALL EDGES OF FLASHING <br />TOP AND BOTTOM COVER PLATE <br />ASSEMBLY - RIVET OR SCREW TO <br />SIDING PANEL TOP (BOTTOM) AND <br />SIDES OF PLATES — <br />V MIN OVERLAP <br />CONT. URETHANE SEALANT ° <br />3/8" MIN. FILLET AROUND PIPE ° <br />° <br />INSULATED -CORE <br />METAL WALL PANELS <br />INTERIOR <br />PANEL CUTOUT (1/2" MINMUM <br />CLEARANCE AROUND PENETRANT) <br />KNIFE PLATE <br />EXPANDABLE FOAM <br />CONT. SEALANT <br />STAINLESS STEEL <br />CLAMPING RING <br />PRE -MOLDED PIPE BOOT <br />(PORTALS PLUS OR EQUAL) <br />PVC FLASHING <br />I ROOF ASSEMBLY <br />® PVC ROOFING MEMBRANE <br />® 4" GLASS MAT GYP SHEATHING FIREGUARD <br />OVERLAYMENT <br />® 5-1/2" POLYISOCYANURATE RIGID INSULATION <br />BOARD <br />I ° 32 MIL SELF -ADHERED VAPOR RETARDER <br />j FIGERGLASS MAT GYP. SHEATHING <br />UNDERLAYMENT <br />® STEEL DECK, REF STRUCTURAL DRAWINGS <br />PIPE THROUurl ROOF r7 <br />SCALE: 1-1/2"44' RFA10-14 A540 <br />SINGLE OR MULTIPLE (7 MAX) <br />PENETRANTS, STEEL PIPE, <br />COPPER TUBING, OR CONDUIT. <br />SEE UL DESIGN FOR APPROVED <br />PENETRANTS <br />FIRE RATED MORTAR <br />CONCRETE FLOOR <br />a <br />BASED ON UL DESIGN: <br />A540 SCALE: 1-1/2"44' <br />SYM <br />REVISION <br />BY <br />APPROVED <br />DATE SYM <br />REVISION <br />BY <br />APPROVED <br />DATE <br />A <br />PFP SPAR PAINT BOOTH 1 AND 2 - IFC <br />W5983281 <br />HG <br />RLT <br />11.19.19 <br />B <br />PFP SPAR PAINT BOOTH 1 AND 2 IFP <br />W5983281 <br />HG <br />RLT <br />11,19.19 <br />SINGLE OR MULTIPLE PENETRANTS C-AJ-1631 <br />SEE UL DESIGNS C-AJ-1631 SHEET A599 FOR ADDITIONAL <br />MIA10-14 I A540 <br />FIRE STOPPING NOTES <br />1. PER IBC 110.3.6, PROTECTION OF JOINTS AND PENETRATIONS IN FIRE -RESISTANCE -RATED ASSEMBLIES, <br />SMOKE BARRIERS AND SMOKE PARTITIONS SHALT. NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND <br />APPROVED BY BUILDING OFFICIAL. <br />2, CONTRACTOR SHALL SUBMIT SPECIFIC DETAIL FOR EACH PENETRATIONS TYPES, EACH PENETRATION <br />DETAIL MUST BE APPROVED BY DESIGN ENGINEER PRIOR TO START OF ANY WORK ON THAT PENETRATION. <br />3. THESE TYPICAL DETAILS SPECIFY DESIGN INTENT. ALL PENETRATIONS THROUGH BUILDING ELEMENTS <br />SHALL BE MADE WITH LEAST OVERSIZE HOLES PRACTICAL AND SHALL BE SEALED WITH SEALANT OR <br />SEALANT AND ESCUTCHEON. PENETRATIONS THROUGH FIRE RESISTANCE RATED BUILDING ELEMENTS <br />SHALL CONFORM TO APPROPRIATE LISTED PENETRATION SYSTEMS. SEE SPECIFICATION SECTION 07 8413 <br />FOR APPROVED FIRE STOPPING MANUFACURERS. <br />SLOPE TO DRAIN <br />4. SEAL ALL PENETRATIONS AFFECTED BY THIS PROJECT. FOR FIRE'RATED SEALANT' SEE SPECIFICATION 07 <br />- INSTALL 4' LUNG FRP PANEL <br />8413. FOR'SEALANT' SEE SPECIFICATION 07 92 00. PROVIDE BACKING ROD OR MINERAL WOOL PACKING AT <br />ON EXISTING PLYWOOD <br />ALL PENETRATIONS MADE THROUGH WALL, FLOOR, OR ROOF ASSEMBLIES WHERE REQUIRED BY UL <br />WAINSCOTT FROM TOP OF <br />DESIGN. PROVIDE METAL SLEEVE TO CONFIRM PACKING WHERE NEEDED. <br />COVE TO 4'-6 AFF <br />91/2' <br />5. MAKE INDIVIDUAL CONDUIT PENETRATIONS. CUT NEAT HOLE THROUGH EXISTING WALL, SIDING OR FLOOR <br />SLAB. MAKE HOLE 1/2" GREATER THAN CONDUIT DIAMETER AT WALL OR SIDING AND 1" GREATER THAN <br />THIS DIMENSION IS FROM <br />CONDUIT DIAMETER AT FLOOR SLAB OR AS RECOMMENDED BY SEALANT MANUFACTURER, ARRANGE <br />FACE OF PLYWOOD WAINSCOT <br />MULTIPLE PENETRATIONS TO MAINTAIN AT LEAST 2-INCH EXISTING SIDING BETWEEN HOLES OR PROVIDE <br />INSTALL FRP ON GWB FROM <br />MULTIPLE PENETRANT FIRE STOPPING DETAIL. <br />TOP OF COVE TO 4'-6 AFF <br />n" <br />THIS DIMENSION IS FROM <br />FACE OF GWB. <br />NOTE; <br />ALL DIMENSIONS ARE FROM FACE OF )TUD(S) OR FACE OF TRENCH LINO. <br />TRENCH <br />SCALE: 3/3"=14' 1A10-14 I A540 <br />INSCOT WHERI U:, <br />URS <br />WAINSCOT AT SIM. — <br />METAL STUD WALL <br />WITH 5/8" GWB EACH <br />SIDF_, SEE WALL TYPES. <br />SCALE: 1-1/2"44' <br />MINERAL WOOL AT <br />FIRE RATED'"'"" <br />Q <br />s � <br />r� <br />} <br />0 <br />SEE WALL TYPE <br />6' <br />METAL DECK <br />DOOR GUIDE PER <br />MANUFACTURER <br />CORNER GUARD CG -1. SEE <br />SPEC SECTION 10 26 00 <br />MC6 X 16.3 <br />TRENCH WHERE OCCURS <br />A351 I A540 <br />== — 0.145"Xi-1/4" POWDER ACTUATED FASTENER @ 16" O.C. MAX TYP <br />17-11 <br />LL I SLOTTED SLIP TRACK OR DEFLECTION TRACK <br />STUDS ATTACHED TO TRACK WITH #8 WAFERHEAD FRAMING SCREWS AT <br />MIDDLE OF SLOTS. <br />ABOVE CEILING AT NON RATED WALLS <br />TYPE S BUGLE HEAD SCREWS ATTACHED TO STUDS. DO NOT ATTACH <br />WALL FINISH TO SLOTTED TRACK. <br />WHERE CEILING OCCURS. SEE REFLECTED CEILING PLAN. <br />CUT STUDS TO I" SHORTER THAN ASSEMBLY HEIGHT. <br />DEFLECTION TRACK 1" COMPRESSION, I" EXTENSION, 2" TOTAL <br />SCALE: 1-1/2"44' <br />5174 <br />ACCEPTABILITY <br />R. PINLAC <br />REGISTERED <br />ARCHITECT <br />THIS DESIGN AND/OR <br />SPECIFICATION IS APPROVED <br />CHECKED <br />R. PINLAC <br />APPROVED BY <br />DEPT. <br />DATE <br />ENGINEER <br />R.GHIGLIANO <br />CHECKED <br />RODERTA L. GHfGLIANO <br />L. COSGROVE <br />STATE OF WASHINGTON <br />APPROVED <br />R. PLUCINSKI <br />11 /21 /2019 <br />APPROVED <br />R THIRTYACRE <br />A540 <br />11.19.19 ARCHITECTURAL MASTER <br />STEEL A <br />COORDI <br />WITH DC <br />MANUFA <br />METALS <br />WITH 5IE <br />SIDE. SE <br />MBLY <br />SCALE: 1-1/2"::V-0" A351 A540 <br />"'NERAL WOOL 4 PCF COMPRESSED 33% IN FLUTE @ FIRE RATED WALLS <br />WHERE TRACK @ HEAD DOES NOT FALL ON FLUTE: 20 GA GALV <br />STEEL CONTINUOUS STRAP FASTENED TO DECK WITH STRIPS <br />IN CONTACT WITH BOTTOM OF DECK. FASTEN TO FLOOR <br />ASSEMBLY WITH STEEL FASTENERS.@ 16" O.C. AND 2" MAX <br />FROM ENDS AT JOINTS. FASTEN AT MID FLUTE. <br />WHERE TRACK HEAD FALLS ON FLUTE: EXTEND GWB TO DECK <br />AND SEAL AT FACE WITH FIRE SEALANT. <br />MIN. 20 GA SLOTTED TRACK WITH 3" LEGS WITH 1 1/2" <br />SLOTS. OR APPROVED DEFLECTION SYSTEM. INSTALL <br />PER MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />CUT STUDS 1" SHORTER THAN ASSEMBLY HEIGHT <br />ACOUSTIC BATT INSULATION <br />WHERE DESIGNATED <br />DEFLECTION TRACK 1" COMPRESSION, 1" EXTENSION, 2" TOTAL <br />FIRE RATED HEAD BASED ON UL HW-D-0633 <br />14 <br />SCALE: 1-1/2"=1'-0" <br />CURRENT REVISION SYMBOL DATE <br />VV5 B 11.19.19 <br />cu��r <br />