IM,Ir 720afr.M� <br />ORDER OF PRECEDENCE <br />IN CASE OF DISCREPANCIES IN CONSTRUCTION DOCUMENTS, THE DRAWINGS SHALL <br />CONTROL OVER THE STRUCTURAL NOTES AND ANY OTHER WRITTEN <br />SPECIFICATIONS. THE STRUCTURAL NOTES SHALL CONTROL OVER ANY OTHER <br />WRITTEN SPECIFICATIONS. <br />A. DESIGN CODES <br />1) WASHINGTON STATE BUILDING CODE BASED ON THE 2015 IBC <br />2) ADDITIONAL REGULATIONS: STATE OF WASHINGTON OCCUPATIONAL <br />SAFETY AND HEALTH ACT. <br />B. OCCUPANCY AND CONSTRUCTION REQUIREMENTS <br />1) RISK CATEGORY II <br />aL��a <br />C. DESIGN CRITERIA F /J.- ort : j1wL OC&F <br />1) LATERAL LOADS r` aj- d rPLomF <br />a) SEISMIC <br />1) SEISMIC IMPORTANCE FACTOR,'E= 1.0 <br />2) SEISMIC IMPORTANCE FACTOR FOR COMPONENTS, IP = 1.( <br />3) MAPPED SPECTRAL RESPONSE ACCELERATION PARAMET <br />SS = 1.446 <br />S, = 0.558 <br />4) SITE CLASS: D <br />5) DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETE <br />SDS = 0.964 <br />SD 0 0.558 <br />6) SEISMIC DESIGN CATEGORY: D <br />7) ANALYSIS PROCEDURES USED: EQUIVALENT STATIC FOR( <br />2) GRAVITY LOADS <br />a) GROUND FLOOR LIVE LOAD = 500 PSF <br />b) ELEVATED FLOOR LOADS <br />1) LIVE LOAD = 60 PSF; LIVE LOAD REDUCTION NOT APPLIED. <br />2) DEAD LOAD = STRUCTURE WEIGHT <br />A. GENERAL <br />1) THESE DRAWINGS HAVE BEEN PREPARED SOLELY FOR USE IN THE <br />CONSTRUCTION OF THE PROJECT LOCATED IN EVERETT, WASHINGTON. <br />POSSESSION OF THESE DRAWINGS DOES NOT GRANT LICENSE TO CONSTRUCT <br />OR FABRICATE THE WHOLE OR PARTS OF THIS PROJECT IN OTHER LOCATIONS. <br />B. COORDINATION <br />1) COORDINATE WORK IN SUCH A MANNER AS TO MINIMIZE IMPACT ON FACILITY <br />OPERATIONS. <br />2) COORDINATE WORK OF OTHER CRAFTS HAVING INTERDEPENDENT <br />RESPONSIBILITIES FOR INSTALLING, CONNECTING TO, AND PLACING IN SERVICE <br />MATERIALS AND EQUIPMENT. <br />3) FIELD VERIFY ALL EXISTING ELEVATIONS AND DIMENSIONS SHOWN ON THE <br />DRAWINGS BEFORE PROCEEDING WITH THE WORK, IMMEDIATELY REPORT ANY <br />DEVIATIONS TO THE OWNER AND ENGINEER. <br />C. CONSTRUCTION METHODS AND PROJECT SAFETY <br />1) THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED <br />STRUCTURE AND DO NOT INDICATE METHODS, PROCEDURES OR SEQUENCE OF <br />CONSTRUCTION. THE STRUCTURE(S) AND ALL OF ITS PARTS MUST BE <br />ADEQUATELY BRACED AGAINST WIND AND LATERAL EARTH AND SEISMIC <br />FORCES UNTIL THE PERMANENT LATERAL FORCE RESISTING SYSTEMS HAVE <br />BEEN CONSTRUCTED AND ALL ATTACHMENTS AND CONNECTIONS NECESSARY <br />FOR THE STABILITY OF THE STRUCTURE(S) AND ITS PARTS HAVE BEEN MADE. <br />THE OWNER AND ENGINEER SHALL NOT BE RESPONSIBLE FOR ENFORCING <br />SAFETY REGULATIONS. THE CONTRACTOR SHALL DESIGN, CONSTRUCT, AND <br />MAINTAIN ALL SAFETY DEVICES. CONSTRUCTION MATERIALS SHALL BE EVENLY <br />DISTRIBUTED IF PLACED ON FRAMED FLOORS OR ROOFS. LOADS SHALL NOT <br />EXCEED ALLOWABLE LOADING FOR THE SUPPORTING MEMBERS OR THEIR <br />CONNECTIONS. THE CONTRACTORS CONSTRUCTION AND/OR ERECTION <br />SEQUENCE SHALL TAKE INTO CONSIDERATION THE EFFECTS OF THERMAL <br />MOVEMENTS OF THE STRUCTURE DURING THE CONSTRUCTION PERIOD. <br />2) THE CONTRACTOR SHALL CONFORM TO ALL FACILITY SAFETY REGULATIONS <br />AND REQUIREMENTS. <br />D. SUBMITTALS <br />1) SUBMITTAL PROCEDURES <br />a) IDENTIFY PROJECT CONTRACTOR, SUBCONTRACTOR, AND/OR SUPPLIER. <br />b) ALL SUBMITTALS SHALL BE PROVIDED IN PDF FORMAT. SUBMITTALS SHALL <br />BE RETURNED IN PDF FORMAT VIA EMAIL OR PROJECT WEBSITE. <br />c) ALLOW FIVE (5) WORKING DAYS MINIMUM FOR REVIEW AND RETURN OF <br />SUBMITTALS. PRODUCT PURCHASE/FABRICATION SHALL NOT COMMENCE <br />UNTIL SUBMITTALS ARE RETURNED. <br />d) SHOP DRAWINGS: ALL SHOP DRAWINGS SHALL BE PREPARED ON <br />ELECTRONIC MEDIA, ANY REVISIONS TO THE DRAWINGS SHALL BE CLOUDED <br />AND MARKED WITH REVISION NUMBERS. <br />e) ALL SUBMITTALS SHALL BE REVIEWED, APPROVED AND INITIALED BY THE <br />SUPPLIER/DETAILER AND BY THE CONTRACTOR PRIOR TO SUBMITTING FOR <br />REVIEW BY THE ENGINEER, ANY SUBMITTALS NOT REVIEWED, APPROVED <br />AND INITIALED BY THE SUPPLIER/DETAILER AND CONTRACTOR SHALL BE <br />RETURNED WITHOUT REVIEW. <br />2) SCHEDULE OF SUBMITTALS: <br />a) SHOP DRAWINGS <br />1) CONCRETE REINFORCING STEEL <br />2) STRUCTURAL STEEL <br />3) METAL FABRICATIONS <br />b) PRODUCT DATA <br />1) CONCRETE MIX DESIGN <br />2) CONCRETE REINFORCING MILL TEST REPORTS <br />c) TESTING AND INSPECTION REPORTS <br />d) WELDER CERTIFICATES <br />E. QUALITY CONTROL <br />1) COMPLY WITH SPECIFIED PROJECT STANDARDS AS A MINIMUM FOR QUALITY <br />FOR THE WORK, EXCEPT WHERE THE DRAWINGS, CODE TOLERANCES, OR <br />SPECIFIC REQUIREMENTS INDICATE HIGHER STANDARDS OR MORE PRECISE <br />WORKMANSHIP. <br />2) CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CORRECTING ALL SITE <br />CONDITIONS CAUSED BY CONSTRUCTION ACTIVITIES. <br />3) PROTECT ALL EXISTING AND NEW UTILITIES, STRUCTURES AND EQUIPMENT <br />FROM DAMAGE. <br />4) CONSTRUCT ALL ITEMS AND COMPONENTS IN FULL ACCORDANCE WITH THE <br />DRAWINGS AND SPECIFICATIONS. ANY VARIANCE MUST HAVE WRITTEN <br />APPROVAL BY THE ENGINEER PRIOR TO CONSTRUCTION. <br />5) UNLESS OTHERWISE NOTED, ALL NEW WORK SHALL MATCH EXISTING IN LINE <br />AND ELEVATION. SHOULD THESE LINES AND ELEVATIONS CONFLICT WITH THE <br />LINES AND ELEVATIONS SHOWN ON THE DRAWINGS, CONTACT THE OWNER AND <br />ENGINEER IMMEDIATELY. <br />A. SITE CONDITIONS <br />1) THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE SITE CONDITIONS. <br />B. MATERIALS <br />1) STRUCTURAL FILL: CLEAN, FREE -DRAINING, WELL -GRADED, CRUSHED ROCK <br />WITH ALL MATERIAL PASSING THE 1 INCH SIEVE AND NOT MORE THAN 5% <br />PASSING THE NUMBER 200 SIEVE. <br />2) FLOWABLE CONTROL DENSITY FILL (FCDF): FLOWABLE, SELF -LEVELING <br />MIXTURE OF PORTLAND CEMENT, FLY ASH, FINE AGGREGATES, AIR <br />ENTRAINING ADMIXTURES AND WATER. EXCAVATABLE: 50 PSI MINIMUM, 100 <br />PSI MAXIMUM 28-DAY COMPRESSIVE STRENGTH. SUBMIT MIX DESIGN TO <br />ENGINEER FOR REVIEW AND APPROVAL PRIOR TO PLACING. <br />C. EXCAVATION <br />1) VERIFY THAT SURVEY BENCHMARKS AND INTENDED ELEVATIONS FOR WORK <br />ARE AS INDICATED. <br />2) REMOVE ALL ORGANIC MATERIAL, TOPSOIL, AND ANY FILL FROM UNDER <br />BUILDINGS AND SLAB AREAS. <br />3) OVER -EXCAVATE AREAS NOT CAPABLE OF IN SITU COMPACTION. <br />4) NOTIFY ENGINEER OF ANY UNUSUAL CONDITIONS ENCOUNTERED IN FOOTING <br />EXCAVATION. <br />5) CLEAN ALL FOOTING AREAS OF LOOSE MATERIAL BY HAND. REMOVE ALL WET, <br />SOFT SOIL FROM FOOTING EXCAVATIONS PRIOR TO PLACING FOUNDATIONS. <br />6) ALL FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED NATIVE SOILS OR <br />COMPACTED STRUCTURAL FILL A MINIMUM OF 18 INCHES BELOW GRADE. NO <br />LOOSE SOIL OR FILL SHALL BE PERMITTED UNDER FOOTINGS OR <br />FOUNDATIONS. <br />D. BACKFILL <br />1) SCARIFY AND PROOF ROLL SUBGRADE TO A DEPTH OF 12 INCHES TO IDENTIFY <br />SOFT SPOTS. REMOVE ANY SOFT SPOTS AND BACKFILL WITH STRUCTURAL <br />FILL. <br />2) BACKFILL OVER -EXCAVATED AREAS WITH STRUCTURAL FILL. <br />3) STRUCTURAL FILL: BACKFILL IN LAYERS NOT TO EXCEED 6 INCHES <br />COMPACTED DEPTH. <br />4) COMPACTION SHALL MEET OR EXCEED THE FOLLOWING REQUIREMENTS AS <br />SHOWN AS A PERCENTAGE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM <br />D698, STANDARD EFFORT, ASTM D1557, MODIFIED EFFORT: <br />a) FILL UNDER SLABS: COMPACTED TO 95%. <br />5) COMPACTION TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM <br />D1556 (SAND CONE METHOD) OR ASTM D6938 (NUCLEAR METHOD). <br />E. TESTING AND INSPECTION <br />INSPECTION1) TESTING AND DIVISION <br />DiVISION _ l_. _ <br />A. REFERENCES <br />1) ACI 301 - STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR <br />BUILDINGS <br />2) ACI 302 - GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION <br />3) ACI 304R - GUIDE FOR MEASURING, MIXING, TRANSPORTING AND PLACING <br />CONCRETE <br />4) ACI 318 - BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND <br />COMMENTARY <br />5) CRSI MSP-1 - MANUAL OF STANDARD PRACTICE <br />6) AWS D1.4 - STRUCTURAL WELDING CODE -REINFORCING STEEL <br />B. CONCRETE REINFORCING <br />1) SUBMITTALS <br />a) SHOP DRAWINGS: INDICATE BAR GRADES, SIZES, SPACING, LOCATION, <br />QUANTITIES, BENDING & CUTTING SCHEDULES. <br />b) MILL TEST REPORTS. <br />2) REINFORCING STEEL <br />a) ASTM A615 GRADE 60 (60 KSI) DEFORMED BAR. <br />1) THE ACTUAL YIELD STRENGTH BASED ON THE MILL TESTS REPORTS <br />SHALL NOT EXCEED THE SPECIFIED YIELD STRENGTH BY MORE THAN <br />18,000 PSI AND THE RATIO OF ACTUAL ULTIMATE TENSILE STRENGTH TO <br />THE ACTUAL YIELD STRENGTH SHALL NOT BE LESS THAN 1.25. IF ASTM <br />A615 GRADE 60 REINFORCING DOES NOT SATISFY THESE REQUIREMENTS, <br />ASTM A706 REINFORCING SHALL BE PROVIDED. <br />b) REINFORCING SUBJECT TO WELDING: ASTM A706 GRADE 60 (60 KSI) <br />DEFORMED BAR. <br />1) USE ONLY LOW HYDROGEN E70XX ELECTRODES. <br />2) WELDING SHALL BE PERFORMED IN ACCORDANCE WITH AWS D1.4. <br />c) DEFORMED BAR ANCHORS (DBA): ASTM A496, TYPE D2L BY TRW NELSON. <br />d) HEADED CONCRETE ANCHORS (HCA) TYPE H4L BY TRW NELSON. <br />3) ACCESSORIES: <br />a) DOWEL BAR SPLICE ASSEMBLIES: LENTQN FORMSAVER BY ERICO PRODUCTS <br />INC. <br />4) UNLESS OTHERWISE NOTED ON THE DRAWINGS, LAP SPLICES FOR <br />REINFORCING SHALL BE AS FOLLOWS: <br />BAP SIZE <br />(US) <br />EAR SIZE <br />METRIC (SI) <br />CLASS B <br />SPLICE <br />(INCH) <br />TOP BAR <br />SPLICE <br />(INCH) <br />#3 <br />#10 <br />19 <br />25 <br />#4 <br />#13 <br />25 <br />33 <br />#5 <br />#16 <br />31 <br />41 <br />#6 <br />#19 <br />37 <br />49 <br />#7 <br />#22 <br />54 <br />70 <br />#8 <br />#25 <br />62 <br />80 <br />#9 <br />#29 <br />69 <br />90 <br />#10 <br />#32 <br />77 <br />100 <br />#11 <br />#36 <br />85 <br />110 <br />#14 <br />#43 <br />108 <br />140 <br />#18 <br />#57 <br />139 <br />180 <br />TOP BARS ARE HORIZONTAL BARS PLACED SUCH THAT MORE <br />THAN 12 INCHES OF • BELOW <br />SPLICE. <br />5) PROVIDE SPECIFIED COVER AS FOLLOWS: <br />a) CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3 <br />INCHES (-3/8 INCH/+1 INCH) <br />b) CONCRETE EXPOSED TO EARTH OR WEATHER: <br />1) #6 BAR AND LARGER: 2 INCHES (-3/8 INCH/+5/8 INCH) <br />2) #5 BAR AND SMALLER: 1 1/2 INCHES (-3/8 INCH/+1/2 INCH) <br />c) CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH EARTH: <br />1) SLABS, WALLS, JOISTS: <br />a. #14 BAR AND LARGER: 1 1/2 INCHES (-1/4 INCH/+1/2 INCH) <br />b. #11 BAR AND SMALLER: 3/4 INCH (-1/4 INCH/+1/4 INCH) <br />2) BEAM, COLUMNS, PEDESTALS (PRIMARY REINFORCING, TIES, STIRRUPS, <br />AND SPIRALS): 1 1/2 INCHES (-3/8 INCH/+1/2 INCH) <br />6) UNLESS OTHERWISE NOTED ON THE DRAWINGS, PROVIDE CORNER BARS TO <br />MATCH HORIZONTAL REINFORCING AT CORNERS AND INTERSECTIONS, <br />C. CAST -IN -PLACE CONCRETE <br />1) MATERIALS. - <br />a) FINE AND COARSE AGGREGATES: ASTM C33, <br />b) ADMIXTURES: <br />1) AIR ENTRAINMENT: ASTM C260 <br />2) ADMIXTURES: ASTM C494 <br />2) ACCESSORIES: <br />a) SEE SPECIFICATION <br />b) CORRUGATED PAPER FORMWORK: SUREVOID PRODUCTS, BY VOIDFORM <br />PRODUCTS, INC. <br />3) CAST IN PLACE ANCHOR RODS: SEE DIVISION 5. <br />4) POST INSTALLED CONCRETE FASTENERS: <br />a) EXPANSION ANCHORS: MECHANICAL EXPANSION TYPE: ICC-ESR APPROVED <br />KWIK BOLT-TZ BY HILTI, INC., OR [CC-ESR APPROVED STRONG BOLT 2 BY <br />SIMPSON STRONG -TIE. <br />b) UNDERCUT ANCHORS: ICC-ESR APPROVED HDA UNDERCUT ANCHOR BY <br />HILTI, INC. OR ICC-ESR APPROVED TORQ-CUT BY SIMPSON STRONG TIE. <br />c) CHEMICAL ADHESIVE ANCHORS: CHEMICAL ANCHOR TYPE: ICC-ESR <br />APPROVED HIT -RE 500 V3 BY HILTI, INC., OR ICC-ESR APPROVED SET-XP BY <br />SIMPSON STRONG -TIE. SEE DIVISION 5 NOTES FOR THREADED ROD <br />MATERIAL TO BE USED WITH ADHESIVE ANCHORS. <br />• ALTERNATE PRODUCTS MUST BE APPROVED w BY THE <br />STRUCTURAL ENGINEER PRIOR TO USE OR PROPOSED <br />SHOWINGALTERNATE PRODUCT SUBMITTALS WILL BE EVALUATED CONSIDERING <br />• CURRENT CODE FOR SEISMIC <br />SPACINGUSES AND LOAD RESISTANCE, PROVIDE MINIMUM EDGE DISTANCE AND <br />D+ ! IN THE PRODUCT'S REPORT <br />OTHERWISE NOTED•, THE DRAWINGS. <br />CONCRETE <br />CONCRETE SHALL BE TRANSPORTED AND PLACED IN ACCORDANCE WITH <br />a) ALL CONCRETE SHALL COMPLY WITH THE REQUIREMENTS OF ACI 318. <br />6 HOT WEATHER CONCRETINGBE IN ACCORDANCEACI 305R. <br />7) COLD WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 306R. <br />8) FINISHING <br />a) ALL FINISHING SHALL BE ACCORDANCE WITH ACI 301 SECTI <br />1. EXPOSED <br />.• :.` SHALL <br />.- Y BE FORMED <br />r.:. 4 INCH <br />CHAMFER <br />. -:- : . <br />OTHERWISE NOTED. <br />c) SEE BOEING SPECIFICATIONS FOR CONCRETE FINISH REQUIREMENTS. <br />S. CURING <br />CONCRETE SHALLBE . BY USE OF A CURING COMPOUND OR BY USE OF <br />CONCRETEAN APPROVED WET CURING PROCESS FOR A MINIMUM OF 7 DAYS AFTER <br />PLACEMENTACCORDANCE ACI 308.1.CURING COMPOLIN <br />SHALL BE APPLIED ACCORDANCE ■ WRITTEN <br />INSTRUCTIONS AND S <br />E. GROUT <br />1) ASTM Cl 107, ICC-ES APPROVED, NON -SHRINK, NON-METALLIC, MINIMUM <br />COMPRESSIVE STRENGTH OF 5000 PSI AT 7 DAYS: FIVE STAR GROUT BY FIVE <br />STAR PRODUCTS OR MASTERFLOW 928 BY BASF. <br />2) EQUIPMENT BASES AND COLUMN BASE PLATES SHALL BE GROUTED IN STRII <br />ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTRUCTIONS. <br />F. TESTING AND INSPECTION <br />1) TESTING AND INSPECTION PER DIVISION 1 <br />A. REFERENCES <br />1) AISC 360 - STEEL CONSTRUCTION MANUAL <br />2) AWS D1.1 - STRUCTURAL WELDING CODE <br />3) SSTC - STRUCTURAL BOLTING HANDBOOK <br />4) SDI - DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS, AND ROOF DECKS <br />B. STRUCTURAL STEEL <br />1) SUBMITTALS: <br />a) SHOP DRAWINGS: INDICATE PROFILES, SIZE, SPACING, LOCATIONS OF <br />STRUCTURAL MEMBERS, OPENINGS, ATTACHMENTS, CONNECTIONS, <br />FASTENERS, CAMBERS, AND WELDMENTS USING AWS WELD SYMBOLS. <br />b) WELDERS CERTIFICATES: PROVIDE WELDERS CERTIFICATES BY AN <br />APPROVED CERTIFYING AGENCY. <br />2) MATERIALS. <br />a) STRUCTURAL STEEL W-SECTION SHAPES: ASTM A992 GRADE 50 (Fy = 50 KSI) <br />b) STRUCTURAL STEEL CHANNELS: ASTM A36 (Fy = 36 KSI). <br />c) STRUCTURAL STEEL PLATES: ASTM A572 GRADE 50 (Fy = 50 KSI). <br />d) STRUCTURAL STEEL ANGLES: ASTM A36 (Fy = 36 KSI). <br />e) HOLLOW STRUCTURAL SHAPES: SQUARE AND RECTANGULAR STRUCTURAL <br />TUBE: ASTM A500 GRADE B (Fy = 46 KSI), ASTM A500 GRADE C (Fy = 50 KSI) <br />WHERE NOTED. <br />f) HIGH -STRENGTH BOLTS (HSB): ASTM F3125 GALVANIZED TO ASTM F2329 <br />UNLESS NOTED OTHERWISE. <br />g) ANCHOR RODS: ASTM F1554 GRADE 36 HEAVY HEX TYPE. RODS, NUTS AND <br />WASHERS GALVANIZED IN ACCORDANCE WITH ASTM F2329. <br />h) THREADED ROD: ASTM F1554 GRADE 36. GALVANIZED IN ACCORDANCE WITH <br />ASTM F2329. <br />i) PLATE WASHERS: ASTM A36. <br />j) HARDENED WASHERS: ASTM F436 TYPE 1. GALVANIZED TO ASTM F2329 UNLESS <br />NOTED OTHERWISE. <br />k) BEVEL WASHERS: ASTM F436 TYPE 1. GALVANIZED TO ASTM F2329 UNLESS <br />NOTED OTHERWISE. <br />1) NUTS (STANDARD, JAMB AND HEAVY HEX TYPE): ASTM A563. GALVANIZED TO <br />ASTM F2329 UNLESS NOTED OTHERWISE. HEAVY HEX NUTS SHALL BE USED IN <br />ALL HSB CONNECTIONS UNLESS OTHERWISE NOTED. ALL NUTS TO HAVE A <br />PROOF LOAD STRESS EQUAL TO OR HIGHER THAN THE MINIMUM SPECIFIED <br />TENSILE STRENGTH OF THE THREADED PART (BOLT OR ROD). <br />m)SHEAR CONNECTOR STUDS AND HEADED CONCRETE ANCHORS: TYPE B <br />IN CONFORMANCE WITH AWS D1.1, AS MANUFACTURED BY NELSON STUD <br />WELDING OR TRU-WELD DIVISION OF TRU-FIT PRODUCTS CORP. <br />INSTALL/FASTEN TO STEEL MEMBERS IN STRICT ACCORDANCE WITH <br />MANUFACTURERS RECOMMENDATIONS. <br />n) WELDING FILLER MATERIAL: AWS D1.1 TABLE 3.1, AWS A5.1 OR A5.5 E70XX FOR <br />SMAW WELDING PROCESS; AWS A5.18 ER70S-X FOR GMAW WELDING PROCESS; <br />AWS A5.17 OR A5.23 F7XX-EXXX FOR SAW WELDING PROCESS; AWS A5.20 <br />E7XT-X FOR FCAW WELDING PROCESS. <br />1) TYPE: LOW -HYDROGEN. <br />C. CONNECTIONS <br />1) ALL STRUCTURAL CONNECTIONS SHALL UTILIZE 3/4 INCH DIAMETER A325 HIGH <br />STRENGTH BOLTS AND BE TYPE N (BEARING WITH THREADS INCLUDED IN THE <br />SHEAR PLANE) UNLESS OTHERWISE NOTED. CONNECTIONS NOTED AS SC (SLIP <br />CRITICAL) SHALL INCLUDE LOAD INDICATOR WASHERS OR USE TENSION <br />CONTROLLED HIGH -STRENGTH BOLTS. FAYING SURFACES OF CONNECTING <br />PARTS IN SC CONNECTIONS SHALL BE PROTECTED AGAINST PAINT AND <br />OVER -SPRAY. <br />2) HIGH STRENGTH BOLTS SHALL BE INSTALLED AND TIGHTENED IN ACCORDANCE <br />WITH RCSC "SPECIFICATIONS FOR STRUCTURAL JOINTS USING HIGH -STRENGTH <br />BOLTS" (AISC 360) AND SSTC "STRUCTURAL BOLTING HANDBOOK". <br />3) ALL HIGH STRENGTH BOLTS SHALL BE FULLY TENSIONED UNLESS NOTED <br />OTHERWISE. <br />D. WELDING <br />1) ALL WELDING SHALL BE PERFORMED IN ACCORDANCE WITH AWS D1.1. <br />2) ALL WELDING ON ELEMENTS OF THE SEISMIC FORCE -RESISTING SYSTEM SHALL <br />BE PERFORMED IN ACCORDANCE WITH AWS D1.8. <br />3) GUARDRAILS AND HANDRAILS SHALL BE PROVIDED WITH CLOSED ENDS AND <br />CONNECTIONS SHALL BE CONTINUOUSLY WELDED UNLESS NOTED OTHERWISE. <br />SYM <br />REVISION <br />BY <br />APPROVED <br />DATE SYM <br />REVISION <br />I BY <br />APPROVED <br />DATE <br />�® Af.p�A ACCEPTABILITY <br />A <br />PFP SPAR PAINT BOOTH 1 AND 2 - IFC REMOVAL <br />W5983281 <br />HG <br />RLT <br />08.09.19 <br />� A � THIS DESIGN AND/OR <br />SPECIFICATION IS APPROVED <br />- <br />B <br />PFP SPAR PAINT BOOTH 1 AND 2 - IFC FOUNDATION <br />VV5983281 <br />HG <br />RLT <br />10.25.19 <br />ill RON:; <br />APPROVED BY <br />DEPT. <br />MIR <br />C <br />PFP SPAR PAINT BOOTH 1 AND 2 - IFC <br />W5983281 <br />HG <br />RLT <br />11,19.19 <br />D <br />PFP SPAR PAINT BOOTH 1 AND 2 - IFP <br />V6983281 <br />HIS <br />RLT <br />11.19.19 <br />36 <br />0ST <br />L <br />2oZo�s <br />DATE <br />CHECKED <br />R. PINLAC <br />ENGINEER <br />K. WITT <br />CHECKED <br />A. WARNER <br />APPROVED <br />R. THIRTYACRE <br />11.06,18 <br />08,09.19 <br />08,09.19 <br />08.09,10, <br />08.09.19 <br />SUBTITLE <br />TITLE <br />STRUCTURAL MASTER <br />E. STEEL GRATING <br />1) EXTERIOR PLATFORM & STAIR LANDING GRATING: TYPE ANSI/NAAMM MBG 531: <br />W-19-4 <br />1 1/4 X 3/16 STEEL. TOP SURFACE: PLAIN. FINISH: PAINTED PER PROJECT <br />SPECIFICATIONS. <br />2) STAIR TREAD GRATING: TYPE ANSI/NAAMM MBG 531: VV--19-4 1 1/2 X 3/16 STEEL. <br />TOP SURFACE: PLAIN. NOSING TYPE: CAST ABRASIVE. FINISH: PAINTED PER. <br />PROJECT SPECIFICATIONS. <br />3) PAINT BOOTH TRENCH GRATING TYPE: TYPE ANSI/NAAMM MBG 531: W-19-4 (3 X <br />1/4) STEEL, MCNICHOLS TYPE "GHB" OR EQUAL. TOP SURFACE: PLAIN. FINISH: <br />GALVANIZED PER ASTM A123. <br />3) SUPPORT SPACE TRENCH GRATING TYPE: TYPE ANSI/NAAMM MBG 531: W 19-4 <br />(1 112 X 3/6) STEEL. TOP SURFACE: PLAIN. FINISH: GALVANIZED PER ASTM A123. <br />4) SPAR PAINT BOOTH SUMP TRENCH GRATING TYPE: TYPE ANSI/NAAMM MBG 531: <br />19-SI-4 (1 1/2 X 1/4) SWAGE -LOCKED ALUMINUM, MCNICHOLS TYPE "GIA" OR <br />EQUAL. <br />5) ACCESSORIES: <br />a) FASTENERS AND SADDLE CLIPS: GALVANIZED. <br />6) GRATING PANELS SHALL BE BANDED USING THE SAME MATERIAL AS GRATING. <br />BAND GRATING PANELS AT THE FOLLOWING LOCATIONS UNLESS OTHERWISE <br />NOTED: <br />a) OPENINGS AND BLOCKOUTS. <br />b) REMOVABLE PANELS. <br />c) PERIMETER OF INDIVIDUAL PANELS. <br />F. STEEL DECK <br />1) SUBMITTALS: <br />a) SHOP DRAWINGS: INDICATE TYPES, PROFILES, SIZES, GAUGES, FINISH, <br />DIMENSIONS, PROPERTIES, SUPPORTS, POSITIONS, LAP LOCATIONS, <br />OPENINGS, FASTENING TYPE AND SCHEDULE, ACCESSORIES, ETC FOR THE <br />FABRICATION AND INSTALLATION OF ALL STEEL DECKING. <br />2) PRODUCTS: VERCO STEEL FLOOR DECK SYSTEM TYPE "PLB FORMLOCK" OR <br />EQUAL BY VERCO STEEL. <br />3) MATERIALS: <br />a) SHEET STEEL: GALVANIZED ASTM A653 GRADE 50 STRUCTURAL QUALITY. <br />FINISH: ASTM A924 G60. <br />b) POWDER -ACTUATED OR PNEUMATIC DRIVEN FASTENERS: TYPE X-ENP-1915 <br />MANUFACTURED BY HILTI, INC., WITH KNURLED SHANKS AND 1/2 INCH <br />DIAMETER (MINIMUM) STEEL CLAMPING WASHERS. PROVIDE SDK2 SEALING <br />CAPS WHERE INDICATED. <br />4) STEEL FLOOR DECK: SECTION DEPTH: 1 1/2 INCH. SECTION THICKNESS: 16 <br />GAUGE. RIB SPACING: 12 INCHES ON CENTER. SIDE LAPS: STANDARD <br />INTERLOCKING SEAM. <br />5) STEEL FLOOR DECK INSTALLATION: SHORE ALL CANTILEVER SPANS, AND ALL <br />OTHER SPANS WHERE REQUIRED BY THE DECK MANUFACTURER. PLACE PANELS <br />AND ADJUST TO FINAL POSITION PRIOR TO PERMANENT ATTACHMENT. PROVIDE <br />2 INCH MINIMUM BEARING, 3 INCH MINIMUM END LAPS. END LAPS SHALL OCCUR <br />OVER SUPPORTS ONLY. PROVIDE SHEAR STUD CONNECTORS WHERE INDICATED <br />ON THE DRAWINGS. ATTACH PANELS AT PERPENDICULAR SUPPORTS WITH 4 <br />FASTENERS PER 36 INCH WIDE PANEL WIDTH. ATTACH PANELS PARALLEL TO <br />SUPPORTS WITH FASTENERS AT 12 INCH ON CENTER MAXIMUM SPACING. PANEL <br />SIDE LAPS SHALL BE FASTENED/INTER-CONNECTED WITH MANUFACTURERS <br />PROPRIETARY INTERLOCKING PUNCH SYSTEM AT 12 INCH ON CENTER MAXIMUM <br />SPACING. <br />6) SPECIAL INSPECTION: ALL STEEL DECK SHALL HAVE SPECIAL INSPECTION AFTER <br />INSTALLATION AND PRIOR TO INSTALLATION OF FINAL COVER. <br />A) CORROSION PROTECTION <br />1) ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL SHOP PRIMED,UNLESS <br />OTHERWISE NOTED. ALL STRUCTURAL AND MISCELLANEOUS STEEL NOTED AS <br />GALVANIZED SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION IN <br />ACCORDANCE WITH ASTM A123. <br />2) FINAL FINISH OF ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL MATCH <br />EXISTING OR SPECIFIED BY BOEING. <br />3) FIELD TOUCH UP OF GALVANIZED STEEL SHALL BE WITH GALVICON COLD <br />GALVINZING COMPOUND. MINIMUM 2 MILS D.F.T. RESTORATION OF THE <br />GALVANIZED COATING SHALL BE IN ACCORDANCE WITH ASTM A780 "STANDARD <br />PRACTICE FOR REPAIR OF DAMAGED AND UNDERSOATED AREA OF HOT -DIP <br />GALVANIZED COATINGS". <br />4) FINAL FINISH OF CONCRETE AND COATING OF CONCRETE SHALL MATCH <br />EXISTING OR SPECIFIED BY BOEING. <br />PFP SPAR PAINT BOOTH 1 AND 2 <br />EVERETT, WA <br />DWG NO. <br />40-058-S2g <br />