My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 45-767 Plans 2023-01-26
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-767
>
Plans
>
3003 W CASINO RD 2019 BLDG 45-767 Plans 2023-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2023 9:57:14 AM
Creation date
1/25/2023 2:05:23 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-767
Permit
B1904-001
B2004-003
Year
2019
Notes
STALL 113 MODIFICATIONS TO BOEING FLIGHTLINE TRAILERS. STALL 113/115 BUILDING MODIFICATIONS BOEING
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br />COPPER WATER PIPELINE RISERS <br />DIELECTRIC UNION <br />ABOVE GRADE <br />GROUNDING CLAMP, <br />TYP OF 2 <br />O • <br />Q0 <br />CONCRETE TRAFFIC BOX WITH TEST STATION <br />M540- 2 <br />r—CONCRETE GRADE <br />`—NATIVE MATERIAL <br />II <br />#10 AWG HMWPE <br />I I I PIPELINE TEST CABLES (BLACK) <br />TOP OF PIPELINES <br />#10 AWG RHW-2/USE-2 <br />ANODE LEAD CABLE (RED) <br />WATER MAIN PIPELINE PRE —PACKAGED HIGH POTENTIAL <br />DIELECTRIC FLANGE INSTALLED AT 18" 18of MAGNESIUM BAG ANODE <br />CONNECTION POINT BETWEEN MIN MIN CL OF FLUSH MOUNT M540-2 <br />COPPER AND CAST IRON COPPER WATER PIPELINE TEST STATION <br />PIPELINES. SEE DETAIL 6/M540-2 <br />NOTE: <br />BURIED COPPER PIPING OMITTED FOR CLARITY. <br />AT -GRADE TEST STATION INSTALLATION - <br />STALL 112 203. 205 <br />SCALE: NONE <br />M540-2 <br />COPPER WATER PIPELINE RISER <br />>__�_,DIELECTRIC UNION <br />ABOVE GRADE GROUNDING CLAMP <br />FCONCRETE TRAFFIC BOX WITH TEST STATION <br />M540 2 <br />.. , .. <br />♦ • <br />I <br />d♦ a d • ♦. •p. I I ♦ . ♦• j p <br />#10 AWG RHW-2/USE-2 <br />ANODE LEAD CABLE (RED) <br />II <br />#10 AWG RHW-2/USE-2 <br />ANODE LEAD CABLE (RED) <br />BOTTOM OF PIPELINE <br />PRE —PACKAGED HIGH POTENTIAL <br />MAGNESIUM BAG ANODEMCOPPER WATER PIPELINE 18" 18'► <br />DIELECTRIC FLANGE INSTALLED M540-2 <br />AT CONNECTION POINT BETWEEN MIN MIN OF FLUSH MOUNT <br />COPPER AND DUCTILE IRON PIPING TEST STATION <br />NOTE: <br />BURIED COPPER PIPING OMITTED FOR CLARITY. <br />AT -GRADE TEST STATION INSTALLATION - <br />STALL 113, 114, 118, 119, 120, 215, 216 <br />SCALE: NONE <br />20'-0" LONG #10 AWG <br />RHW-2/USE-2 ANODE <br />LEAD CABLE (RED) <br />LOW RESISTIVITY BACKFILL <br />CLOTH BAG <br />in <br />HIGH POTENTIAL MAGNESIUM ANODE <br />(2-3/4"x3-3/4"x59-3/4" LONG) <br />20 LB BARE WEIGHT AND <br />80 LB PACKAGED WEIGHT <br />M540 2 <br />HIGH POTENTIAL MAGNESIUM BAG ANODE DETAIL <br />SCALE'. NONE M540-2 <br />SYM I REVISION I BY I APPROVED I DATE I SYM I REVISION BY APPROVED DATE <br />ORIG I 777X STALL MODIFICATIONS W45357371 CEI I MS 1 12.29.17 <br />COTT <br />12" THICK CONCRETE GRADE <br />PROVIDE 18" MINIMUM CABLE <br />SLACK IN BOTTOM OF VALVE BOXY <br />#10 AWG HM PE PIPELINE <br />TEST CABLES (BLACK) — <br />13-13/16" <br />° ♦ �� • 4e <br />° ° TEST STATION TERMINAL BOARD <br />M540-2 <br />10-3/8" I.D. 02" HIGH DENSITY \, REINFORCED CONCRETE TRAFFIC VALVE <br />BOX WITH BOLT DOWN CAST IRON LID <br />NATIVE MATERIAL BELOW VALVE BOX <br />#10 AWG RHW-2/USE-2 ANODE LEAD (RED) <br />TYPICAL TRAFFIC BOX WITH TEST STATION DETAIL <br />scn¢: zone u,sao-z <br />SHUNT (ON BACKSH <br />#10 AWG RHW /USE-2 <br />ANODE CABLE (RED), <br />LprA r_ If <br />��_*,,44m <br />FINK" TERMINAL BOARD (BLUE) <br />I, <br />IN <br />COTT 0.1 OHM SHUNT i <br />STAINLESS STEEL BOLT. <br />#10 AWG HMWPE PIPELINE <br />TEST CABLES (BLACK) <br />COLLET NUT (BLUE) <br />FRONT VIEW <br />SIDE VIEW <br />NLESS STEEL <br />K WASHER, TYP <br />NLESS STEEL NUT, <br />AP TIGHT RING TERMINAL <br />ILATED GRIP, TYP <br />TYPICAL TEST STATION TERMINAL BOARD DETAIL � <br />SCALE' NONE M540-2 <br />INSULATING BOLT SLEEVE <br />INSULATING WASHER <br />316L STAINLESS STEEL <br />WASHER <br />316L STAINLESS STEEL <br />STUD <br />DUCTILE IRON PIPELINE---- <br />FULL—FACE WELD NECK <br />DUCTILE IRON FLANGE <br />FULL —FACE INSULATING GASK <br />BURIED DIELECTRIC FLANGE <br />SCALE: NONE <br />INSULATING WASHER <br />316L STAINLESS STEEL WASHER <br />316L STAINLESS STEEL NUT (TYP) <br />COPPER PIPELINE <br />FULL —FACE BRAZED <br />NECK FLANGE <br />titllf= <br />GENERAL NOTES <br />t. REFER TO MECHANICAL HARD STAND DETAILS ON <br />SHEET M558-2, 3, AND 4 ,FOR MECHANICAL <br />HARD STAND COMPONENTS, DIMENSIONS, AND <br />DIELECTRIC FLANGE KIT INSTALLATION LOCATIONS. <br />REFERENCE DRAWINGS <br />CONSTRUCTION NOTES <br />1. PRIOR TO INSTALLATION OF INSULATING GASKET, <br />CLEAN ALL SURFACES, REMOVE OIL, GREASE, AND <br />DIRT. <br />2. AFTER INSTALLATION OF INSULATING GASKET, TEST <br />AND CONFIRM PROPER ELECTRICAL ISOLATION, PER <br />SPECIFICATION SECTION 221100. <br />3. AFTER ELECTRICAL ISOLATION TESTING IS COMPLETE, <br />COAT ENTIRE INSULATING JOINT WITH VISCOUS <br />ELASTIC INSULATING JOINT WITH VISCOUS ELASTIC <br />POLYOLEFIN COATING SYSTEM PER <br />SPECIFICATION SECTION 221100. <br />FOR REFERENCE ONLY <br />FACILITY DESIGN <br />ACCEPTABILITY <br />THIS DESIGN AND/OR <br />SPECIFICATION IS APPROVED <br />DRAWN <br />B. HOPKINS <br />DATE <br />12.29.17 <br />SUBTITLE <br />CATHODIC PROTECTION <br />- DETAILS <br />CHECKED <br />T. LOONEY <br />12.29.17 <br />APPROVED BY <br />DEPT. <br />DATE <br />ENGINEER <br />M. HERNBERG <br />12.29.17 <br />TITLE 777X STALL MODIFICATIONS <br />SITE 4 <br />-Y D <br />CHECKED <br />APPROVED <br />BY CEI <br />DATE 03.26.19 <br />ISSUE FOR PERMIT <br />3/26/2019 <br />CURRENT REVISION SYMBOL DATE <br />W4535737 0 R I G 12.29.17 <br />SHEET <br />M540-2 <br />JOB NO. <br />EVERETT, WA DWG NO. <br />MECHANICAL MASTER <br />45-YD-M540-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.