Laserfiche WebLink
STRUCTURAL ABBREVIATIONS <br />& <br />- AND <br />@ <br />- AT <br />.9 DEG <br />- DEGREE <br />0, DIA <br />- DIAMETER <br />(E), EXIST <br />- EXISTING <br />NO <br />- NUMBER <br />LB <br />- POUND <br />AB <br />- ANCHOR BOLT <br />ABV <br />- ABOVE <br />ADDL <br />- ADDITIONAL <br />ADH <br />- ADHESIVE <br />ADJ <br />- ADJACENT <br />AFS <br />- ABOVE FINISHED SLAB <br />ALT <br />- ALTERNATE <br />ALUM <br />- ALUMINUM <br />APPROX <br />- APPROXIMATE <br />AR <br />- AS REQUIRED <br />ARCH <br />- ARCHITECTURAL <br />ASPH <br />- ASPHALT <br />ASSY <br />- ASSEMBLY <br />BASE PL <br />- BASE PLATE <br />BLDG <br />- BUILDING <br />BLKG <br />- BLOCKING <br />BLW <br />- BELOW <br />BM(S) <br />- BEAM(S) <br />BO xxx <br />- BOTTOM OF xxx <br />BOT <br />- BOTTOM <br />BRB <br />- BUCKLING RESTRAINED BRACE <br />BRG <br />- BEARING <br />BS <br />- BOTH SIDES <br />BTWN <br />- BETWEEN <br />C <br />- CHANNEL <br />CANT <br />- CANTILEVER <br />CDF <br />- CONTROLLED DENSITY FILL <br />CEM PLAS <br />- CEMENT PLASTER <br />CIP <br />- CAST -IN -PLACE <br />ci <br />- CONSTRUCTION JOINT/CONTROL JOINT <br />Cip <br />- COMPLETE JOINT PENETRATION <br />WELD <br />CL <br />- CENTER LINE <br />CLR <br />- CLEAR(ANCE) <br />cmu <br />- CONCRETE MASONRY UNIT <br />COL <br />- COLUMN <br />CONC <br />- CONCRETE <br />CONN <br />- CONNECT(ION) <br />CONSTR <br />- CONSTRUCTION <br />CONT <br />- CONTINUOUS <br />CONTR <br />- CONTRACTOR <br />COORD <br />- COORDINATE <br />CSK <br />- COUNTER SUNK <br />CTR <br />- CENTER(ED) <br />D <br />- DEPTH/DEEP <br />DO <br />- DEMAND CRITICAL <br />DBL <br />- DOUBLE <br />DEG <br />- DEGREE <br />DEMO <br />- DEMOLITION <br />DET <br />- DETAIL <br />DA <br />- DIAMETER <br />DAG <br />- DIAGONAL/DIAGRAM <br />DIM <br />- DIMENSION <br />DIST <br />- DISTANCE <br />DN <br />- DOWN <br />DWG <br />- DRAWING <br />DWL <br />- DOWEL <br />EA <br />- EACH <br />EF <br />- EACH FACE <br />EJ <br />- EXPANSION JOINT <br />EL <br />- ELEVATION <br />ELEC <br />- ELECTRICAL <br />ELEV <br />- ELEVATOR <br />EMBED <br />- EMBEDMENT/EMBEDDED <br />EOS <br />- EDGE OF SLAB <br />EQ <br />- EQUAL <br />EQL SPCD <br />- EQUALLY SPACED <br />EQUIP <br />- EQUIPMENT <br />ES <br />- EACH SIDE <br />ESC <br />- ESCALATOR <br />EW <br />- EACH WAY <br />EXP <br />- EXPANSION <br />EXT <br />- EXTERIOR <br />FIN <br />FINISH(ED) <br />PAF <br />POWER ACTUATED FASTENER <br />FLO <br />- FLANGE <br />PAR <br />PARALLEL/ PARAPET <br />FLR <br />- FLOOR <br />PC <br />PRECAST CONCRETE <br />FO xxx <br />- FACE OF xxx <br />PEMB <br />PRE ENGINEERED METAL BUILDING <br />FOC <br />- FACE OF CONCRETE <br />PEN <br />PENETRATE/PENETRATION <br />FOF <br />- FACE OF FINISH <br />PIL <br />PILASTER <br />FOS <br />- FACE OF STEEL <br />pip <br />PARTIAL JOINT PENETRATION <br />FP <br />- FIREPROOFING) <br />WELD <br />/FIRE PROTECTION <br />PL <br />- PLATE <br />FRT <br />- FIRE RETARDANT TREATED <br />P L C S <br />- PLACES <br />FS <br />- FAR SIDE <br />PNI <br />- PANEL <br />FT <br />- FOOT, FEET <br />PRCST <br />- PRECAST <br />FTG <br />- FOOTING <br />PREFAB <br />- PREFABRICATED <br />PSF <br />POUNDS PER SQUARE FOOT <br />GA <br />- GAGE/GAUGE <br />PSI <br />POUNDS PER SQUARE INCH <br />GALV <br />- GALVANIZED <br />PT <br />POST TENSIONED/PRESSURE TREATED <br />GEN <br />- GENERAL <br />PUR <br />PURLIN <br />GLB <br />- GLUE LAMINATED TIMBER <br />GR <br />- GRADE <br />R <br />RADIUS <br />GB <br />- GRADE BEAM <br />RC <br />REINFORCED CONCRETE <br />GYP BD <br />- GYPSUM BOARD <br />RD <br />ROOF DRAIN <br />REF <br />REFERENCE <br />H <br />- HIGH <br />REINS <br />- REINFORCING <br />HDR <br />- HEADER <br />REQD <br />- REQUIRED <br />HGR <br />- HANGER <br />RO <br />- ROUGH OPENING <br />HLDN <br />- HOLDDOWN <br />RTU <br />- ROOFTOP UNIT <br />HORIZ <br />- HORIZONTAL <br />HSS <br />- HOLLOW STRUCTURAL <br />SO <br />- SLIP CRITICAL <br />SECTION <br />SCHED <br />- SCHEDULE <br />HT <br />- HEIGHT <br />SLRS <br />- SEISMIC LOAD RESISTING SYSTEM <br />HVAC <br />- HEATING, VENTILATING AND <br />SHT <br />- SHEET <br />AIR CONDITIONING <br />SHTHG <br />- SHEATHING <br />Sim <br />- SIMILAR <br />0 <br />- INSIDE DIAMETER <br />sms <br />SHEET METAL SCREW <br />IF <br />- INSIDE FACE <br />SPEC <br />SPECIFICATION <br />li <br />- ISOLATION JOINT <br />SPCS <br />SPACES <br />IL <br />- INSIDE LAYER <br />SQ <br />SQUARE <br />IN <br />- INCHES <br />SSH <br />SHORT SLOTTED HOLE <br />INFO <br />- INFORMATION <br />SST <br />STAINLESS STEEL <br />INSUL <br />- INSULATE/INSULATION <br />STD <br />STANDARD <br />INT <br />- INTERIOR <br />ST117 <br />STIFFENER <br />STLI <br />STEEL <br />JST <br />- JOIST <br />STL JST <br />- STEEL JOIST <br />JT <br />- JOINT <br />STRUCT <br />- STRUCTURAL <br />SYMM <br />- SYMMETRICAL <br />KIP <br />- KIP (1,000 POUNDS) <br />K& <br />- KIPS PER SQUARE INCH <br />TB <br />- THROUGH BOLT <br />KWY <br />- KEYWAY <br />TBC <br />- THREADED BAR COUPLER <br />TBR <br />- TO BE REMOVED <br />L <br />- ANGLE/LENGTH <br />THK <br />- THICK(NESS) <br />LBR <br />- LUMBER <br />T.O. xxx <br />- TOP OF xxx <br />LLBB <br />- LONG LEG BACK TO BACK <br />TOO <br />- TOP OF CONCRETE <br />LLH <br />- LONG LEG HORIZONTAL <br />TOF <br />- TOP OF FOOTING <br />LLV <br />- LONG LEG VERTICAL <br />TOGB <br />- TOP OF GRADE BEAM <br />LC <br />- LOCATION <br />TOS <br />- TOP OF STEEL <br />LSH <br />- LONG SIDE HORIZONTAL <br />TOSL <br />- TOP OF SLAB <br />LSV <br />- LONG SIDE VERTICAL <br />TOW <br />- TOP OF WALL <br />TRANSV <br />- TRANSVERSE <br />MAX <br />- MAXIMUM <br />TRTD <br />- TREATED <br />MB <br />- MACHINE BOLT <br />TYR <br />- TYPICAL <br />MBR <br />- MEMBER <br />T/C <br />- TENSION/COMPRESSION CORD <br />MECH <br />- MECHANICAL <br />T&B <br />- TOP AND BOTTOM <br />MEZZ <br />- MEZZANINE <br />T&G <br />- TONGUE AND GROOVE <br />MFR <br />- MANUFACTURE(R/D) <br />MFR REC <br />- MANUFACTURER'S <br />UON <br />- UNLESS OTHERWISE NOTED <br />RECOMMENDATIONS <br />MH <br />- MANHOLE <br />VIF <br />- VERIFY IN FIELD <br />MID <br />- MIDDLE <br />VNR <br />- VENEER <br />MIN <br />- MINIMUM <br />VERT <br />- VERTICAL <br />MISC <br />- MISCELLANEOUS <br />W <br />- WIDE/WIDTH <br />NA <br />- NOT APPLICABLE <br />WD <br />- WOOD <br />NIC <br />- NOT IN CONTRACT <br />WF <br />- WIDE FLANGE <br />NIP <br />- NOT IN PERMIT <br />WO <br />- WHERE OCCURS <br />NORM <br />- NORMAL <br />WP <br />- WATERPROOFING/WORK POINT <br />NO <br />- NUMBER <br />WPM <br />- WATERPROOF MEMBRANE <br />NS <br />- NEAR SIDE <br />WT <br />- WEIGHT <br />NTS <br />- NOT TO SCALE <br />WWF <br />- WELDED WIRE FABRIC <br />W/ <br />- WITH <br />Oc <br />- ON CENTER <br />W/o <br />- WITFIOUT <br />OD <br />- OUTSIDE DIAMETER <br />OF <br />- OUTSIDE FACE <br />YD <br />- YARD <br />OFS <br />- OUTSIDE FACE OF STUDS <br />OPH <br />- OPPOSITE HAND <br />OPNG <br />- OPENING <br />OPP <br />- OPPOSITE <br />Ovs - OVERSIZED (HOLES) <br />sym I REVISION BY APPROVED DATE SYM REVESlOhf BY APPROVED DATE <br />ORIG 45-001 STRUCTURAL VERTICAL UPGRADES 1786915 CPA 10.08.19 <br />A DEFERRED SUBWTTAL 1786915 CP&A/HSK 07.10.20 <br />N <br />BUILDING CODE <br />ALLCONSTRUCTION, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF <br />THESE DRAWINGS, SPECIFICATIONS, AND THE CODES, RULES AND REGULATIONS OF THE <br />INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION, AS ADOPTED AND AMENDED BY THE CITY OF <br />EVERETT, HEREINAFTER REFERRED TO AS THE BUILDING CODE. <br />E L_ <br />ENGINEER OF RECORD <br />FOR ALL ASPECTS OF THE STRUCTURAL VERTICAL UPGRADES, CASPER, PHILLIPS & ASSOCIATES <br />WILL DESIGNATE A PARTICULAR PERSON AS THE REGISTERED DESIGN PROFESSIONAL, ALSO KNOWN <br />I <br />HEREIN AS THE "ENGINEER OF RECORD," (EOR). THE DESIGNATED FOR WILL BE THE <br />PROFESSIONAL ENGINEER THAT SEALS THESE DRAWINGS. <br />STANDARDS <br />CONSTRUCTION, MATERIALS, AND WORKMANSHIP SHALL ALSO CONFORM TO THE FOLLOWING <br />STANDARDS. WHERE THESE STANDARDS CONFLICT WITH THE BUILDING CODE, THE BUILDING CODE <br />SHALL GOVERN. <br />ASCE "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES" <br />AMERICAN SOCIETY OF CIVIL ENGINEERS <br />ASCE/SEI 7-10 <br />AWS 'STANDARD SYMBOLS FOR WELDING, BRAZING, AND NON-DESTRUCTIVE EXAMINATION <br />AMERICAN WELDING SOCIETY <br />AWS A2.4: 2012 <br />"STANDARD WELDING TERMS AND DEFINITIONS" <br />AMERICAN WELDING SOCIETY <br />AWS A3,OM/A3.0® 2010 <br />AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" <br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />ANSI/RISC 360-10 <br />AISO "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" <br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />ANSI/AISC 303-10 <br />AWS "STRUCTURAL STEEL WELDING CODE - STEEL" <br />AMERICAN WELDING SOCIETY <br />AWS Dl.1/DIIM: 2010, AS MODIFIED BY ANSI/RISC 360-10 <br />RCSC "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS,' <br />RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS <br />DECEMBER 31, 2009 <br />DESIGN CRITERIA <br />ONLY GRAVITY LOADS ARE CONSIDERED FOR THIS WORK. PER l8kC SECTION 101.4.7, <br />WORK ON EXISTING BUILDINGS IS GOVERNED BY THE INTERNATIONAL EXISTING <br />BUILDING CODE (IEBC), 2015 EDITION, PER THE IEBC WORK AREA METHOD, THE <br />ALTERATIONS TO THE 45-001 BUILDING QUALIFY AS A "LEVEL 1" ALTERATION. A <br />LEVEL 1 ALTERATION ONLY REQUIRES A GRAVITY LOAD ANALYSIS PER IEBC SECTION <br />707.2. <br />SCUPPERS ARE REQUIRED ON BOTH THE HIGH -BAY AND LOW -BAY ROOFS IN ORDER <br />TO PREVENT OVERLOADING OF THE ROOF STRUCTURE BY PONDING. SCUPPERS SHALL <br />BE INSTALLED AND FUNCTIONAL AS PART OF THE 45-001 STRUCTURAL VERTICAL <br />UPGRADES, AND PRIOR TO RE -OCCUPANCY OF THE 45-001 BUILDING. <br />DESIGN LOADS <br />1. (L) LIVE LOADS <br />FAN ROOM 40 PSF <br />WALK-ON CEILING 200 LBS CONC. (SEE WALK-ON <br />m <br />2. (D) DEAD LOAUw <br />FLOOR DEAD LOAD, ROOF SYSTEM, <br />HVAC, FRAMING, CEILING, PIPING, ETC. <br />3. (W) <br />WIND LOADS <br />N/A <br />4. (E) <br />SEISMIC LOADS <br />N/A <br />5, (S) <br />SNOW LOADS <br />GROUND SNOW LOAD Pg <br />FLAT ROOF (BALANCED) SNOW LOAD Ps <br />MAX. SNOW DRIFT Pdr (AT LOW ROOF) <br />(Pdr TAPERS TO 0 PSF @ 15 FT) <br />6. (R) <br />RAIN LOADS <br />PONDING <br />RAIN -ON -SNOW SURCHARGE <br />CEILING DRAWINGS FOR ADDITIONAL <br />LOADING CRITERIA) <br />SEE ITEM 7 BELOW. <br />20 PSF (UNREDUCED) <br />Ihm <br />wil offilr3mul all <br />17,55 PSF <br />11.06 PSF <br />60.34- PSF <br />SEE CALCULATIONS <br />5 PSF <br />DESIGN LOADS (CONT.) <br />7. CRANE LOADS <br />HIGH -BAY STACKER <br />CRANES (2) LOW -BAY <br />STACKER CRANES (6) <br />ENGINE INSERT CRANES (2) <br />(D) = 72.4K <br />EACH <br />(D) = 37,2K EACH <br />(D) = 1 O.OK EACH <br />Q = 2.OK EACH <br />(L) = 2,0K EACH <br />(L) = 10. 0 K EACH <br />DESIGN LOAD COMBINATIONS <br />1. <br />LRFD <br />LOAD COMBINAT0NS <br />FOR MAIN STRUCTURAL <br />SYSTEM: <br />(A) <br />1.4D <br />(8) <br />1.2D <br />+ 1.6L + 0.5S <br />(C) <br />11.2D <br />+ 1.6S + 0.5L <br />2, <br />ASD <br />LOAD COMBINATIONS <br />FOR SOIL LOADING - <br />(A) <br />D <br />(B) <br />D + <br />L <br />(C) <br />D + <br />S <br />(D) <br />D + <br />0.51_ + 0.5S <br />GENERAL NOTES <br />1. THE STRUCTURAL DRAWINGS REPRESENT THE DESIGN OF MODIFICATIONS TO THE PRIMARY <br />STRUCTURE BASED ON PRESCRIBED LOADS (SEE "DESIGN LOADS" SECTION), IMPOSED ON THE <br />STRUCTURE PER THE BUILDING CODE AS SPECIFIED IN THE "BUILDING CODE" SECTION. THE <br />PRIMARY STRUCTURE OF THE BUILDING IS DEFINED AS THE COLUMN FOOTINGS, COLUMNS, BEAMS, <br />SUSPENDED FLOOR SLAB, TRUSSES, FLOOR FRAMING, CEILING FRAMING, AND LATERAL FORCE <br />RESISTING ELEMENTS REQUIRED TO MAINTAIN THE STABILITY OF THE COMPLETED STRUCTURE AS A <br />WHOLE. <br />2. ALL CONSTRUCTION MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE <br />DRAWINGS, SPECIFICATIONS, AND THE CODES, RULES AND REGULATIONS OF THE BUILDING CODE AS <br />DEFINED IN THE "BUILDING CODE" AND "STANDARDS" SECTIONS. <br />3. THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE <br />METHOD OF CONSTRUCTION. METHOD OF CONSTRUCTION AND ALL RELATED COST AND SCHEDULE <br />CONCERNS ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL PROVIDE ALL <br />MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES <br />SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION <br />EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT <br />INCLUDE INSPECTION OF THE ABOVE ITEMS. <br />4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY BRACING AS REQUIRED FOR THE <br />STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL MEMBERS ARE IN PLACE AND FINAL <br />CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE MEANS, <br />METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. <br />6. CONSTRUCTION TOLERANCES SHALL CONFORM TO THE BUILDING STANDARDS SPECIFIED IN THE <br />"BUILDING CODE" SECTION UNLESS STRICTER TOLERANCES ARE NECESSARY FOR THE FORM, <br />FIT AND FUNCTION OF THE COMPONENT AND/OR BUILDING. <br />7. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO <br />CONSTRUCTION. THE FOR SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES IN A <br />PROMPT MANNER. <br />8. IF ANY ERRORS OR OMISSIONS APPEAR TO EXIST IN THESE DRAWINGS, SPECIFICATIONS, OR OTHER <br />CONTRACT DOCUMENTS; THE CONTRACTOR SHALL NOTIFY THE FOR IN WRITING AND SHALL RESOLVE <br />ANY SUCH OMISSION OR ERROR BEFORE PROCEEDING WITH THE WORK. <br />9. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL <br />DETAILS. WHERE SPECIFIC NOTES AND DETAILS ON DRAWINGS AND THE GENERAL NOTES AND <br />TYPICAL DETAILS ARE IN CONFLICT WITH THE PROJECT SPECIFICATIONS, THE MOST STRINGENT SHALL <br />APPLY. CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED AS SHOWN FOR SIMILAR <br />WORK, SUBJECT TO REVIEW BY THE EOR. <br />10. MANUFACTURED MATERIALS SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO THEIR USE. <br />ALL REQUIREMENTS OF THOSE APPROVALS SHALL BE FOLLOWED, <br />11. THE CONTRACTOR SHALL COORDINATE THE STRUCTURAL DRAWINGS WITH DRAWINGS FROM ALL <br />OTHER DISCIPLINES, INCLUDING BUT LIMITED TO ARCHITECTURAL, CIVIL, MECHANICAL, CRANES AND <br />ELECTRICAL. <br />12. SEE MECHANICAL, PLUMBING, ELECTRICAL AND OTHER SPECIALTY DRAWINGS AND <br />PROJECT SPECIFICATIONS FOR THE FOLLOWING: <br />A. PIPE RUNS, SLEEVES, HANGERS, TRENCHES, WALL, ROOF AND FLOOR OPENINGS, ETC., NOT <br />SHOWN OR NOTED. <br />B. ELECTRICAL CONDUIT RUNS, BOXES, OUTLETS IN WALLS AND SLABS. <br />C. ANCHORAGE AND BRACING FOR ELECTRICAL, MECHANICAL OR PLUMBING EQUIPMENT To THE <br />STRUCTURE. <br />D. ANCHOR BOLTS FOR MOTOR MOUNTS. <br />E. SIZE, WEIGHT AND LOCATION OF MACHINES AND EQUIPMENT BASES. <br />13. OPENINGS, POCKETS, ETC, SHALL NOT BE PLACED IN STRUCTURAL MEMBERS UNLESS SPECIFICALLY <br />DETAILED ON THE STRUCTURAL DRAWINGS. <br />14. MATERIAL SPECIFICATIONS ARE ASTM LATEST EDITION. <br />A DENDUM Gl - 07.102020 <br />DEFERRED SUMTTAL <br />ACCEPTABILITY <br />THIS DESIGN AND/OR �CHECKED <br />SPECIFICATION IS APPROVED <br />DRAWN <br />DATE <br />SUBTITLE <br />STRUCTURAL ABBREVAMNS AND NOTES <br />CURRENT REVISION <br />17869151 <br />I SYMBOL DATE <br />A 07.10.20 <br />SHEET <br />S2-1 <br />rNGINEER <br />I - <br />TITLE 45-001 STRUCTURAL VERTICAL UPGRADES <br />BUILDNIG 45-001 <br />MASTER EVERETT, WA45-001 <br />APPROVED BY <br />DEPT. I DATE <br />CHECKED <br />. 1786915 COMP NO, <br />APPROVED <br />APPROVED <br />:71STRUCTURAL <br />DWG IUD, <br />-S2-1 <br />