My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 MERRILL CREEK PKY A T AND T WIRELESS ANTENNA 2023-02-06
>
Address Records
>
MERRILL CREEK PKY
>
2215
>
A T AND T WIRELESS ANTENNA
>
2215 MERRILL CREEK PKY A T AND T WIRELESS ANTENNA 2023-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2023 2:17:49 PM
Creation date
2/6/2023 2:15:36 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2215
Tenant Name
A T AND T WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
#'11-1-" <br /> EXISTING LTE �^� �� REMOVE POWER EQUIPMENTFROM EXISTING AT&T <br /> FIBER SLACK BOXOX CONVERTER SHELF, REMOVEVE CONVERTER SHELF; <br /> EXISTING AT&T ICE TRANSFER LOADS TO NEW POWER PLANT <br /> BRIDGE (+/-34'-0") EXISTING TE40 <br /> CABINET W/ <br /> �� EXISTING RAYCAP DER CRO�N <br /> .•�.�.A.AIM&.•.• �+ �� ♦.�. -__ UMTS CONVERTER EXISTING <br /> BEI REMOVED <br /> .�Ie, .♦`.�.�.�". CABINET SYSTEM & RELOCATE EXISTING FSM4 AMIA FROM EXISTING <br /> �1i�0 •�♦� ♦� ► MINI—PURCELL FLX16 TO(NEW)FLX21 CASTLE <br /> EXISTING AT&T FEEDLINES '-,j♦�♦j EXISTING i \•i / <br /> — (12) 1-5/8" COAX CABLES °4V+ v 1505 WESTLAKE AVENUE NORTH,SUITE 800 <br /> — (4) #8 AWG DC TRUNKS 1 r-, (6) DIPLEXERS % / <br /> — (2) FIBER TRUNK FNo\ 4 SEATTLE,WA 98109 <br /> - (1) RENT '��� <br /> ''4k-ltV • • � 0 <br /> EXISTING AT&T RRH TO BE RELOCATED TO TOWER 47t� S I EXISTING EXISTING <br /> NOKIA 4T4R B5 AHCA Ss�� TELCO BOX ARGUS TE40 EXISTING P.MARSHALL&ASSOCIATES <br /> (TOTAL OF 3, 1 PER SECTOR) ��♦�� DC4PLANT4& BATTERY TELCO BOX <br /> INET TO <br /> `� BATTERIES BE REMOVED <br /> EXISTING ♦�`♦ 1 EXISTING <br /> BATTERY NOTE: <br /> AC PANEL <br /> TO REMOVE (2) EXPIRED BATTERY STRINGS POWER METER �- <br /> CONTRACTOR �• <br /> (#4 & #1) - / hi EXISTING S GENERAT RUR TIERFACE GE & S \R v 9 <br /> EXISTING +24v DC POWER PLANT TO BE REMOVED <br /> EXISTING PLATFORM EXISTING AT&T 14'-6" x BU #: 826263 <br /> ACCESS LADDER 19'-6" EQUIPMENT PLATFORM MUKILTEO HEIGHTS <br /> 2215 MERRILL CREEK PKWY <br /> T___/ \____/ \____ EVERETT, WA 98203 <br /> 11.2E; EXISTING EQUIPMENT PLAN w <br /> EQUIPMENT LAYOUT SHOWN IS BASED ON THE PREVIOUS 1"=2'-0" (FULL SIZE) I <br /> CONSTRUCTION DRAWINGS DONE BY CROWN CASTLE 2 1 0 2' 1"=4'-0" (11x17) REV DATE DESCRIPTION <br /> DATED 10/23/19 AS WELL AS MOST RECENT AUDIT Z -.......(nilli r n <br /> PHOTOS AN7 MEASUREMENTS.IF EQUIPMENT LAYOUT A 8/4/21 PRELIMS <br /> DIFFERS FROM WHAT IS SHOWN,CONTRACTOR TO --- - - - - - - <br /> CONTACT THE CONSTRUCTION MANAGER. ' 0 9/10/21 FOR CONSTRUCTION <br /> EXISTING LTE /-------\ 7.-----.\ <br /> FIBER SLACK BOX <br /> PROPOSED FLX-21 CABINET MOUNTED <br /> EXISTING AT&T ICE ON EXISTING PUNTH <br /> BRIDGE (+/-34'-0") EXISTING <br /> - / TE40 EXISTING FSM4/AMIA WILL BE MIGRATED TO A NEW FLX21. ONE 100A <br /> � ♦�,r♦ -lair.�.�� _ EXISTING CABINET W/ DC BREAKER WILL BE REQUIRED FOR THE NEW FLX21 CABINET. <br /> .=.....♦..1+�..♦., ; �. �....♦♦..- •-_ UMTS RAYCAP DC12 EXISTING FSM4 (AMIA) - UTIUZE EXISTING (1) ASIA AND (3) ABTA <br /> ��I►��4^�� CABINET & SIAD - - <br /> • � •��.=♦=:.�- � CARDS ON THE Cl SIDE FOR LTE. RELOCATE EXISTING (1) ASIK AND <br /> •C�i'4 <br /> EXISTING AT&T FEEDLINES '��•♦♦♦ I I (1) ABIL CARDS ON THE C2 SIDE TO A NEW AMIA. <br /> /�♦♦♦ EXISTING / I PROPOSED FSM4 (AMIA) - EXISTING (1) ASIK AND (1) ABIL CARDS <br /> - (12) 1-5/8" COAX CABLES 0fi♦i�♦ / / �� I RELOCATED TO THE Cl SIDE FROM THE EXISTING AMIA; UTILIZE FOR 5G <br /> - (4) #8 AWG DC TRUNKS p♦♦♦ (6) DIPLEXERSI <br /> (2) FIBER TRUNK �i�♦i / _ ---J 850. ADD (2) ABIL ON THE Cl SIDE FOR 5G 1900/AWS. ADD (1) <br /> - ♦♦♦ / .\ N\/ ASIK AND (3) ABIL ON THE C2 SIDE FOR 5G C n77. <br /> - (1) RENTQ. <br /> PROPOSED AT&T (1) �.!NR�4 __ <br /> #6 AWG DC TRUNK(S) '' 1iB♦ ♦ ♦4.♦♦ ♦♦♦ ♦ ♦♦♦♦♦♦♦♦♦N♦♦♦♦•♦ ♦♦♦♦ <br /> PROPOSED DC12-48-60-0-25E-SSii♦ • <br /> ;i♦i♦i♦i0♦1V"♦i♦i♦i♦iri♦�i♦i♦i♦ii♦i♦ii♦i♦i♦i♦i♦i"Aiiiii"VC <br /> (RE-TERMINATE EXISTING SPARE #8 AWG DC TRUNK !•♦♦♦ X S I <br /> FROM ID RAYCAP TO NEW OD RAYCAP DC12 FOR AHCA) �`♦�Q TELCO BOX EXISTING <br /> TELCO BOX <9�O DESIGNED:JLB <br /> R♦♦♦ <br /> ��♦♦ c� DRAWN: JLB <br /> ytr. <br /> �0 4114s.00 <br /> CHECKED: PWM <br /> EXISTING [ i / • i' EXISTING4022019 <br /> POWER METER AC PANEL °$ � JOB # <br /> PROPOSED -48V EMERSON NETSURF 512 DC PLANT EXISTING SURGE & 21 CCAO6M-0055 <br /> - GENERATOR INTERFACE Mel NUMBER 504-106 184 <br /> W/ (10) RECTIFIERS & (2) CONVERTER MODULES <br /> PROPOSED EMERSON BATTERY CABINET <br /> EXISTINGACNGSS LTFORM - RE-CONFIGURE (10) EXISTING +24V BATTERY STRINGS TO (2.5)STRI -48V FOR BATTERY EXISTING AT&TIP14'-P" x EXISTING & FINAL <br /> 19'-6" EQUIPMENT PLATFORM <br /> EQUIPMENT PLANS <br /> INSTALLER NOTE; <br /> CROWN CASTLE HAS BEEN INFORMED BY THE CARRIER THAT THE RE2AOVAL OF THE <br /> EXISTING EQUIPMENT AND REPLACEMENT WITH NEW EQUIPMENT WILL NOT INVOLVE ANY <br /> MODIFICATION OR UPGRADES TO THE EXISTING AC ELECTRICAL SYSTEM MID THAT THE <br /> FINAL EQUIPMENT PLAN <br /> PROPOSED EQUIPMENT WILL UTILIZE THE SAME BREAKER,WIRE,AND CONDUIT THAT <br /> 1"=2'-0" (FULL SIZE) WAS USED FOR THE EQUIPMENT BEING REPLACED.THE CONTRACTOR IS TO NOTIFY C- .2 <br /> ;. THE ENGINEER OF RECORD IF ANY ELECTRICAL MODIFICATIONS TO THE EXISTING AC <br /> 2 <br /> , 1 <br /> ��0 .,:2' 1"=4'-0" (11x17) ELECTRICAL SYSTEM ARE NECESSARY FOR THE REQUESTED WORK TO BE PERFORMED. <br />
The URL can be used to link to this page
Your browser does not support the video tag.