My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 MERRILL CREEK PKY A T AND T WIRELESS ANTENNA 2023-02-06
>
Address Records
>
MERRILL CREEK PKY
>
2215
>
A T AND T WIRELESS ANTENNA
>
2215 MERRILL CREEK PKY A T AND T WIRELESS ANTENNA 2023-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2023 2:17:49 PM
Creation date
2/6/2023 2:15:36 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2215
Tenant Name
A T AND T WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job Page <br /> tnxTower Norpro,WA BU#826263 1 of 33 <br /> Vertical Structures,Inc. Project Date <br /> 309 Spangler Dr.Suite E Vertical Structures Job No. 2021-003-036 15:22:38 07/30/21 <br /> Richmond,KY 40475 Client Designed by <br /> Phone:(859)624-8360 Crown Castle <br /> FAX:(859)624-8369 Jonathan Makinen <br /> Tower Input Data <br /> The tower is a monopole. <br /> This tower is designed using the TIA-222-H standard. <br /> The following design criteria apply: <br /> • Tower is located in Snohomish County,Washington. <br /> • Tower base elevation above sea level:490.00 ft. <br /> • Basic wind speed of 98 mph. <br /> • Risk Category II. <br /> • Exposure Category C. <br /> • Simplified Topographic Factor Procedure for wind speed-up calculations is used. <br /> • Topographic Category: 1. <br /> • Crest Height: 0.00 ft. <br /> • Nominal ice thickness of 1.0000 in. <br /> • Ice thickness is considered to increase with height. <br /> • Ice density of 56 pc£ <br /> • A wind speed of 30 mph is used in combination with ice. <br /> • Temperature drop of 50°F. <br /> • Deflections calculated using a wind speed of 60 mph. <br /> • The existing structure load modification factors,Kes,from TIA-222-H Annex S were considered in this analysis. <br /> • A demand-capacity ratio of 1.05 was used in this analysis as allowed by TIA-222-H. <br /> • CCISeismic Note: Seismic loads generated by CCISeismic 3.3.7. <br /> • CCISeismic Note: Seismic calculations are in accordance with TIA-222-H. <br /> • A non-linear(P-delta)analysis was used. <br /> • Pressures are calculated at each section. <br /> • Stress ratio used in pole design is 1. <br /> • Tower analysis based on target reliabilities in accordance with Annex S. <br /> • Load Modification Factors used:Kes(FW)=0.95,Kes(ti)=0.85,Kes(Ev,and Eh)= 1.0. <br /> • Maximum demand-capacity ratio is: 1.05. <br /> • Local bending stresses due to climbing loads,feed line supports,and appurtenance mounts are not considered. <br /> Options <br /> Consider Moments-Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules <br /> Consider Moments-Horizontals Assume Legs Pinned I Calculate Redundant Bracing Forces <br /> Consider Moments-Diagonals 4 Assume Rigid Index Plate Ignore Redundant Members in FEA <br /> Use Moment Magnification 4 Use Clear Spans For Wind Area 4 SR Leg Bolts Resist Compression <br /> -4 Use Code Stress Ratios 4 Use Clear Spans For KL/r All Leg Panels Have Same Allowable <br /> d Use Code Safety Factors-Guys Retension Guys To Initial Tension Offset Girt At Foundation <br /> Escalate Ice 4 Bypass Mast Stability Checks 4 Consider Feed Line Torque <br /> Always Use Max Kz 4 Use Azimuth Dish Coefficients -4 Include Angle Block Shear Check <br /> Use Special Wind Profile 4 Project Wind Area of Appurt. Use TIA-222-H Bracing Resist.Exemption <br /> Include Bolts In Member Capacity I Autocalc Torque Arm Areas Use TIA-222-H Tension Splice Exemption <br /> NI Leg Bolts Are At Top Of Section Add IBC.6D+W Combination Poles <br /> i Secondary Horizontal Braces Leg Sort Capacity Reports By Component 4 Include Shear-Torsion Interaction <br /> Use Diamond Inner Bracing(4 Sided) -4 Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow <br /> 4 SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets <br /> SR Members Are Concentric Ignore KL/ry For 60 Deg.Angle Legs Pole Without Linear Attachments <br /> Pole With Shroud Or No Appurtenances <br /> Outside and Inside Corner Radii Are <br />
The URL can be used to link to this page
Your browser does not support the video tag.