Laserfiche WebLink
Job Page <br /> x m Tower Norpro,WA BU#826263 14 of 33 <br /> Vertical Structures,Inc. Project Date <br /> 309 Spangler Dr.Suite E Vertical Structures Job No. 2021-003-036 15:22:38 07/30/21 <br /> Richmond,KY 40475 Client Designed by <br /> Phone:(859)624-8360 Crown Castle <br /> FAX. (859)624-8369 Jonathan Makinen <br /> Description Elevation Offset Azimuth E„ Er. Ejz Ej, <br /> From Angle <br /> Centroid <br /> fi ft lb lb lb lb <br /> to 136ft) <br /> CCISeismic(2) 127.08 0.00 0.0000 0.40 0.00 0.00 0.38 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(122.083333ft <br /> to132.083333ft) <br /> CCISeismic(2) 117.08 0.00 0.0000 0.40 0.00 0.00 0.32 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(112.083333ft <br /> to122.083333ft) <br /> CCISeismic(2) 107.08 0.00 0.0000 0.40 0.00 0.00 0.27 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(102.083333ft <br /> to112.083333ft) <br /> CCISeismic(2) 97.08 0.00 0.0000 0.40 0.00 0.00 0.22 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(92.083333ft <br /> to102.083333ft) <br /> CCISeismic(2) 87.08 0.00 0.0000 0.40 0.00 0.00 0.18 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(82.083333ft <br /> to92.083333ft) <br /> CCISeismic(2) 77.08 0.00 0.0000 0.40 0.00 0.00 0.14 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(72.083333ft <br /> to82.083333ft) <br /> CCISeismic(2) 67.08 0.00 0.0000 0.40 0.00 0.00 0.11 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(62.083333ft <br /> to72.083333ft) <br /> CCISeismic(2) 57.08 0.00 0.0000 0.40 0.00 0.00 0.08 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(52.083333ft <br /> to62.083333ft) <br /> CCISeismic(2) 47.08 0.00 0.0000 0.40 0.00 0.00 0.05 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(42.083333ft <br /> to52.083333ft) <br /> CCISeismic(2) 37.08 0.00 0.0000 0.40 0.00 0.00 0.03 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(32.083333ft <br /> to42.083333ft) <br /> CCISeismic(2) 27.08 0.00 0.0000 0.40 0.00 0.00 0.02 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(22.083333ft <br /> to32.083333ft) <br /> CCISeismic(2) 17.08 0.00 0.0000 0.40 0.00 0.00 0.01 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(12.083333ft <br /> to22.083333ft) <br /> CCISeismic(2) 10.04 0.00 0.0000 0.16 0.00 0.00 0.00 <br /> RFFT-36SM-001-xxM(3/8") <br /> From 8 to 136(8ft <br /> to12.083333ft) <br /> CCISeismic miscl 2"Flex 134.04 0.00 0.0000 0.58 0.00 0.00 0.62 <br /> Conduit From 8 to 136 <br /> (132.083333ft to136ft) <br /> CCISeismic miscl 2"Flex 127.08 0.00 0.0000 1.49 0.00 0.00 1.41 <br /> Conduit From 8 to 136 <br /> (122.083333ft to132.083333ft) <br /> CCISeismic miscl 2"Flex 117.08 0.00 0.0000 1.49 0.00 0.00 1.20 <br />