Laserfiche WebLink
DESIGN SPECIFICATION <br />RISK CATEGORY: <br />II <br />CONSTRUCTION: <br />SFD <br />ZONING: <br />RESIDENTIAL <br />SNOW LOAD (ASCE7-16): <br />25 PSF <br />EXPOSURE CATEGORY: <br />C <br />WIND SPEED (ASCE7-16): <br />110 <br />ULTIMATE <br />MPH <br />LEGEND <br />JB I (N) JUNCTION BOX <br />UM (E) UTILITY METER <br />MSP (E) MAIN SERVICE PANEL <br />IQ (N) ENPHASE IQ COMBINER <br />AC (N) FUSED AC DISCONNECT <br />O 0 VENT, ATTIC FAN (ROOF <br />OBSTRUCTION) <br />ROOF ATTACHMENT <br />CONDUIT <br />❑ ENPHASE IQ8PLUS-72-2-US (240V) <br />MICROINVERTER <br />Q CELLS Q.PEAK DUO BLK <br />ML-G10+ (400W) MODULES <br />UNIRAC SOLARMOUNT LIGHT <br />RAIL 168" MILL <br />- TRENCH <br />PANEL HEIGHT OFF ROOF 1 6" <br />MODULE TYPE, DIMENSIONS & WEIGHT <br />NUMBER OF MODULES: <br />32 MODULES <br />MODULE TYPE: <br />Q CELLS Q.PEAK DUO BLK <br />ML-G10+ (400W) <br />MODULE WEIGHT: <br />48.5 LBS <br />MODULE DIMENSIONS: <br />74" X 41.1" = 21.12 SF <br />UNIT WEIGHT OF AREA: <br />12.3 PSF <br />DEAD LOAD CALCULATION <br />EQUIPMENT'S <br />DESCRIPTIONS <br />QTY <br />LBS/UNIT <br />TOTAL WEIGHT <br />MODULES <br />32 <br />48.5 <br />1552 <br />MID CLAMP <br />54 <br />0.3 <br />16.2 <br />END CLAMP <br />20 <br />0.31 <br />6.2 <br />UNIRAC SOLARMOUNT <br />LIGHT RAIL 168" MILL <br />17 <br />6.89 <br />117.13 <br />SPLICE BAR <br />10 <br />0.65 <br />6.5 <br />RT-200-MINI BK2 <br />67 <br />0.5 <br />33.50 <br />TOTAL WEIGHT OF THE SYSTEM (LBS) <br />1731.54 <br />TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) <br />675.87 <br />WEIGHT PER SQ. FT. (LBS) <br />2.57 <br />WEIGHT PER PENETRATION (LBS) <br />25.85 <br />SCALE: 3/32"= l'-0" <br />ROOF DESCRIPTION <br />ROOF <br />ROOF <br />TILT <br />AZIMUTH <br />RAFTER <br />SIZE <br />RAFTER <br />SPACING <br />ROOF MATERIAL <br />#1 <br />21 ° <br />103' <br />2" x 6" <br />24" o.c. <br />COMP SHINGLE <br />#2 <br />21 ° <br />193' <br />2" x 6" <br />24" o.c. <br />COMP SHINGLE <br />#3 <br />21 ° <br />283' <br />2" x 6" <br />24" o.c. <br />COMP SHINGLE <br />—J <br />2'.q" <br />� I <br />OF #3 <br />TICT_21` <br />AZIA4. - 283- <br />i 1 <br />11 _g,. 2 _3" <br />ARRAY AREA & ROOF <br />AREA CALC'S <br />ROOF <br /># OF MODULES <br />ARRAY AREA (Sq. Ft.) <br />#1 <br />10 <br />211.21 <br />#2 <br />6 <br />126.73 <br />#3 <br />16 <br />337.94 <br />(TOTAL ARRAY AREA/TOTAL ROOF AREA) X 100% <br />= (675.87/2559.9) X 100% = 26.41 % <br />0 <br />ROOF <br />TILT _ #1 <br />21° <br />M AZIM 103' <br />O <br />� U <br />w <br />coo � <br />LLJ <br />i <br />• LL— <br />AN <br />co <br />• <br />coo <br />2p-_8„ <br />ROOF #2 <br />AZIA4 _ 9 0 <br />�3 <br />Lumio <br />SMART ENERGY TODAY <br />(SET) <br />1550 DIGITAL DR, LEHI, UT <br />84043, USA <br />SYSTEM INFO <br />(32) Q CELLS <br />Q.PEAK DUO BLK ML-G10+ <br />(400 W ) <br />(32) ENPHASE <br />IQ8PLUS-72-2-US (240V) <br />DC SYSTEM SIZE: 12.800 kWDC <br />AC SYSTEM SIZE: 9.600 kWAC <br />REVISIONS <br />DESCRIPTION I DATE I REV <br />PROJECT NAME & ADDRESS <br />Q <br />U) <br />O <br />N <br />00 <br />rn <br />N <br />0 <br />N <br />U <br />LJJ <br />U <br />� <br />w <br />CDZ <br />Y <br />LL] <br />W <br />rn <br />0So <br />w <br />w <br />j <br />CD <br />1]� <br />Q� <br />Q <br />W <br />J <br />Q <br />(D <br />Q <br />O <br />0 <br />U <br />DATE: 11 /1 /2022 <br />SHEET NAME <br />ROOF PLAN <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-3 <br />