Laserfiche WebLink
TRANE° <br />Product Specifications <br />OUTDOOR UNIT (a) (b) <br />4TWL606OAlXXXA <br />POWER CONNS. — V/PH/HZ (c) <br />208-230/1/60 <br />MIN. BRCH. CIR. AMPACITY <br />29 <br />BR. CIR. PROT. RTG. — MAX. (AMPS) <br />50 <br />COMPRESSOR <br />CLIMATUFF®- SCROLL <br />NO. USED — NO. STAGES <br />1 — 1 <br />VOLTS/PH/HZ <br />208-230/1/60 <br />R.L. AMPS (d)— L.R. AMPS <br />22.2 — 127.9 <br />FACTORY INSTALLED <br />START COMPONENTS (e) <br />NO (USE BAYSKT263) <br />INSULATION/SOUND BLANKET <br />NO <br />SUMP HEAT <br />NO <br />OUTDOOR FAN <br />PROPELLER <br />DIA. (IN.) — NO. USED <br />27.5 — 1 <br />TYPE DRIVE — NO. SPEEDS <br />DIRECT— 1 <br />CFM @ 0.0IN. W.G. M <br />4466 <br />NO. MOTORS — HP <br />1-1/4 <br />MOTOR SPEED R.P.M. <br />825 <br />VOLTS/PH/HZ <br />208-230/1/60 <br />F.L. AMPS <br />1.3 <br />OUTDOOR COIL — TYPE <br />PLATE FIN <br />ROWS—F.P.I. <br />2-16 <br />FACE AREA (SQ. FT.) <br />15.02 <br />TUBE SIZE (IN.) <br />5/16 <br />REFRIGERANT CONTROL <br />EXPANSION VALVE <br />REFRIGERANT <br />LBS. — R-410A (O.D. UNIT) (9) <br />8 LBS, 5 OZ. <br />FACTORY SUPPLIED <br />YES <br />LINE SIZE — IN. O.D. GAS (h) (i) <br />7/8 <br />LINE SIZE — IN. O.D. LIQ. <br />3/8 <br />CHARGING SPECIFICATIONS <br />SUBCOOLING <br />10°F <br />DIMENSIONS <br />H X W X D <br />CRATED (IN.) <br />46.88 X 54.5 X 23.0 <br />WEIGHT <br />SHIPPING (LBS.) <br />267 <br />NET (LBS.) <br />240 <br />(a) Certified in accordance with the Air -Source Unitary Air -conditioner <br />Equipment certification program, which is based on AHRI standard <br />210/240. <br />(b) Rated in accordance with AHRI standard 270. <br />M Calculated in accordance with Natl. Elec. Codes. Use only HACR <br />circuit breakers or fuses. <br />(d) This value shown for compressor RLA on the unit nameplate and on <br />this specification sheet is used to compute minimum branch circuit <br />ampacity and max. fuse size. The value shown is the branch circuit <br />selection current. <br />(e) No means no start components. Yes means quick start kit <br />components. PTC means positive temperature coefficient starter. <br />Optional kit shown. <br />M Standard Air — Dry Coil — Outdoor <br />(9) This value approximate. For more precise value see unit nameplate. <br />(h) Reference the outdoor unit ship -with literature for refrigerant piping <br />length and lift guidelines. Reference the refrigerant piping software <br />pub # 32-3312-xx or refrigerant piping application guide SS- <br />APG006-xx for long line sets or specialty applications (xx denotes <br />latest revision). <br />0) Trane outdoor condensing units are factory charged with the system <br />charge required for the outdoor condensing unit and 15 feet of tested <br />connecting lines. If connecting line length exceeds 15 feet, then final <br />refrigerant charge adjustment is necessary. Each additional foot over <br />15 feet requires 0.6 ozs of refrigerant. See the Installer's Guide for <br />full charging instructions. <br />4TW L6060A-SUB-1 A-E N <br />