Laserfiche WebLink
PRODUCT /2 (PREMIUM) <br />1-1/2"N.P.T. INLET (3) <br />_Q R <br />z <br />43.21 INSIDE <br />6.50 10.50 t, 10.50 6.50 <br />19.44 1_ '1_3",. 1 17.77 <br />m"iN <br />SCALE: 1" V-0" <br />SUMP SENSOR J-BOX 184 <br />ELBY CAPPED ELBOW (TYP.) <br />DISPENSER SKIN <br />SEAL OFF (TYP.) <br />SUMP SENSOR (TYP.) 201 <br />rq <br />DRIVE SLAB (TYP.) <br />•_ � t l i t i I <br />II 11 li <br />• - d� 1 1 I I I I <br />• II II fi <br />• II II II <br />II II li <br />II II <br />(1) 3/4" SENSOR CONDUIT 184 <br />I II II <br />WITH SEAL -OFF ROUTED <br />THROUGH SUMP FRAME. ii i 1 <br />II <br />i <br />11 Ii II <br />3/4" CONDUIT <br />-SUMP SENSOR <br />4" FLEXIBLE ENTRY BOOT (TYP,) 124 .4 y. _ . • . <br />3/4" CONDUIT -CAT 5 ETHERNET <br />1" CONDUIT-DISP POWER/COMM <br />3/4" CONDUIT-DISP INTERCOM <br />2 FRONT VIEW SECTION DETAIL <br />SCALE: 1" 1*-Ow <br />WAYNE OVATION DISPENSER (TYP.) 51 --- <br />DISPENSER SUMP (TYP.) <br />ANCHOR BOLT MOUNTING FLANGES (TYP.) <br />DRIVE SLAB (TYP.) <br />4" FLEXIBLE ENTRY <br />BOOT (TYP-) <br />1-1 /2" OR 2" D.W. <br />FLEXIBLE PRODUCT 140 ' <br />LINE INSIDE 4" ACCESS <br />14" CONDUITS <br />GRAVEL <br />SINGLE WALL FRP <br />150 <br />OVERY..LINE (TYP.) <br />�59 VECOVERY <br />MTION FITTING SHOWN <br />WW..W.VTED LOW ON SUMP <br />WALL FOR CLARITY <br />PURPOSES ONLY <br />2" FLEXIBLE ENTRY BOOT (TYP. 12 <br />SIDE VIEW SECTION <br />SCALE: 1" = 1'-0" <br />WAYNE OVATION DISPENSER (TYP.) 5i <br />DISPENSER SUMP (TYP.) <br />ANCHOR BOLT MOUNTING FLANGES (TYP.) <br />DRIVE SLAB (TYP.) <br />4" FLEXIBLE ENTRY <br />BOOT (TYP.) <br />1-1 /2" OR 2" D.W. <br />FLEXIBLE PRODUCT 140 1 <br />LINE INSIDE 4" ACCESS <br />PIPE (TYP.) <br />] 4.1 " • (2) 3/4" CONDUITS <br />-S • t. <br />PEA GRAVEL <br />,.: 2" SINGLE WALL FRP <br />• 4 RECOVERY .LINE (TYP.) <br />2" FLEXIBLE ENTRY BOOT (TYP.) <br />SIDE VIEW SECTION <br />SCALE: 1" = 1'-0" <br />3/4" CONDUIT LOCATION INTO <br />DISPENSER HEAD (INTERCOM) <br />PRODUCT /3 (DIESEL) <br />1" N.P.T. VAPOR RECOVERY <br />OUTLET, (WHEN USED) <br />W <br />n r <br />C4 s� <br />z <br />0 <br />cr> N <br />1'* CONDUIT LOCATION INTO <br />DISPENSER HEAD (POWER/COMM. <br />5/8" x 2" SLOTS FOR ANCHOR <br />BOLTS, 4 LOCATIONS <br />CONDUIT LOCATIONS <br />(POWER/COMMUNICATION, <br />INTERCOM. ETHERNET) <br />80 PRODUCT SHEAR VALVE (TYP.) <br />1 1 /2" UNIONS do NIPPLES BY CONTRACTOR. CANOPY <br />AS REO'D. (1" FOR VAPOR RECOVERY) COLUMN (TYP-) <br />$1 VAPOR SHEAR VALVE (TYP.) ••. <br />SET TOP OF SUMP AT 1 /2" <br />ABOVE TOP OF ISLAND <br />as CONCRETE ISLAND WITH SMOOTH <br />STEEL TROWEL FINISH <br />EXPANSION JOINT (TYP.) <br />° SEE STAGE If <br />b DESIGN NOTE <br />a ON DETAIL 15 42" WIDE 89 <br />DOUBLE <br />1-1 /2" x 12" FLEX RADIUS PIPE <br />$2 CONNECTOR (TYP.) ... GUARD <br />CONCRETE <br />FILLED (TYP.) <br />1212" FLEXIBLE ENTRY BOOT (TYP,) <br />UNDER DISPENSER <br />PEA GRAVEL CONTAINMENT SUMP <br />84 1-1/2" BLACK STEEL RISER <br />(TYP.) <br />DISPENSER SUMP <br />-PIPING UNIONS & NIPPLES BY CONTRACTOR. <br />AS REO'D. <br />$i VAPOR SHEAR VALVE (TYP.) *•• <br />PRODUCT SHEAR VALVE (TYP.) <br />1-1 /2" x 12" FLEX <br />CONNECTOR (TYP.) '►•• <br />1-1/2" BLACK STEEL RISER (TYP.) <br />EXPANSION JOINT (TYP.) <br />PRODUCT LINE TRACER TAPE (6" MIN. <br />12" MAX.) WRAP AROUND SUMP <br />c FOR TAPE CONTINUITY <br />_$2 166 <br />11- /2" FNPTWBUSHING (TYP.)X <br />SUMP SENSOR (TYP.) <br />9*0 <br />UNDER DISPENSER SEE STAGE If <br />'NI", --*CONTAINMENT SUMP DESIGN NOTE <br />145 SWIVEL ELBOW (TYP.) ON DETAIL /5 <br />14 SWIVEL COUPLING (TYP.) <br />142 TEST TUBE TERMINATION (TYP.) <br />► DISPENSER SUMP (END SUMP) <br />PIPING UNIONS 4c NIPPLES BY CONTRACTOR, <br />AS REO`D. <br />$i VAPOR SHEAR VALVE (TYP.) ••• <br />$0 PRODUCT SHEAR VALVE (TYP.) <br />82 1-1 /2" x 12" FLEX <br />CONNECTOR (TYP.) ••� <br />° $4 1-1/2" BLACK STEEL RISER (TYP.) <br />4. EXPANSION JOINT (TYP.) <br />010011-1 <br />° PRODUCT LINE TRACER TAPE (6" MIN. <br />12" MAX.) WRAP AROUND SUMP <br />1000 ° ° FOR TAPE CONTINUITY <br />o . <br />152 166 2" FRP ELBOW WITH 2" FRP X <br />1-1/2" FNPT BUSHING (TYP.) <br />201 SUMP SENSOR (TYP.) <br />UNDER DISPENSER <br />' CONTAINMENT SUMP <br />144 SWIVEL TEE (TYP.) <br />SEE STAGE 11 <br />DESIGN NOTE <br />14 CROSSOVER TUBING (TYP.) ON DETAIL /5 <br />TO REMAIN CONNECTED <br />AFTER TESTING <br />143 SWIVEL COUPLING (TYP.) <br />DISPENSER SUMP (PASS THRU) <br />"NOTE: WHERE DIESEL <br />LINE PASSES THRU <br />THE DISPENSER SUMP. <br />CONTRACTOR TO <br />SUPPLY AND INSTALL <br />PLUG IN THE TEE <br />FITTING <br />DIESEL FUEL WHIP (73 <br />HOSE �— <br />DIESEL FUEL HOS 74 <br />BREAKAWAY <br />DIESEL FUEL 72 <br />HOSE <br />CAT DOOR TUBAR RETROFIT <br />LOCK JOWC-0-1 AND <br />INTERIOR DOOR LOCK <br />SECURITY BOX KIT <br />►DWC-O-SB; SUPPLIED BY <br />OWNER. INSTALLED BY <br />CONTRACTOR <br />DIESEL NOZZLE 70 <br />W/ SWIVEL (TYP-) 71 <br />3/4" MONITORING <br />CONDUIT WITH SEALOFF <br />ROUTED THROUGH <br />OFFSET IN SUMP FRAME <br />(TYP-) <br />CAULK ALL AROUND <br />DISPENSER BASE (TYP.) <br />;ION JOINT (TYP.) <br />a <br />.4 I 1 4 d . <br />I• <br />4 41 1 q <br />1� I 1 3 4 NSOR 10 <br />CONDUIT W SEALOFF $4 <br />II 1 I ROUTED THROUGH SUMP FRAME. <br />1 1 <br />I I 1 1 <br />I 1 I <br />I I 1 I <br />I 3/4" CONDUIT - SUMP SENSOR <br />I I GUARRPREMIUM <br />I I 1 1(1) 1" CONDUIT-DISP. POWER/COMM. (1) <br />1 I 3/4" CONDUIT -INTERCOM AND (1) 3/4" <br />I I I (CONDUIT -CAT 5 ETHERNET: ALL WITH <br />L_ J 1SEALOFFS AND ROUTED THROUGH SUMP <br />I IFRAME. ROUTE CONDUITS INTO DISPENSE <br />I (BEZEL AREA (TYP.) CONNECT TO POTTED <br />L — — — — — — WITTING CANOPY FOUNDATION <br />`;z DISPENSER ON GRADE INSTALLATION DETAILS <br />SCALE: 1" V-0" <br />2'-6" <br />ANGLE IRON CROSS <br />BRACES SUPPLIED <br />4' -4" <br />T$. <br />'63 GASOLINE FUEL <br />WHIP HOSE <br />64UEL HOSE <br />BREAKAWAY <br />51 WAYNE "OVATION" <br />3+ 1 BLENDER <br />62 GASOLINE FUEL <br />HOSE <br />60 GASOLINE NOZZLE <br />61 (TYP-) <br />0 <br />oil <br />�'•iiii <br />4- <br />1 <br />l.-----------�♦ <br />° L <br />d 4. <br />4 <br />1 p- <br />1 4 1� 4 <br />1 I 1 I I 1 CD <br />1 I �, � 1` .1 • a i <br />41 1 <br />I I' � I •I I <br />DIESEL <br />I 1 Ir : 14 1 <br />VAPOR 1 ( J' 4• I 1 <br />RECOVERY••• 1 1 a4 4 I <br />•rs 1 ( , : 1 1 cp <br />SEE STAGE 11 <br />DESIGN NOTE 4 <br />ON DETAIL /5 1 ' - 6" SIM. A3.0 <br />5'-0" <br />•*e STABILIZER KIT — VAPOR C86 <br />_ • , _ � rrrr ■rrrr �rrr. rrr� arrrr rrr� <br />s - I ■sir ■i.i■ ■i■I■ <br />� • rill �' <br />WA rl.0 ri=I■ <br />• 1 i � • i � i` i <br />SCALE: i" V-0" <br />ADA COMPLIANCE NOTE: <br />WHEN DISPENSERS ARE INSTALLED AS SHOWN <br />ON THIS DRAWING, THE REQUIREMENTS <br />REGARDING HANDICAPPED VERTICAL AND <br />HORIZONTAL ACCESSIBILITY ARE FULLY MET. <br />SAFETY NOTE: <br />WHEN DISPENSERS ARE INSTALLED AS SHOWN <br />ON THIS DRAWING, THE REQUIREMENTS OF <br />NFPA 30A 6.3.9 AND 6.3,9.1 REGARDING <br />SHEAR SECTIONS ARE FULLY MET. <br />STAGE 11 DESIGN NOTE: <br />IN AREAS WHERE STAGE II VAPOR RECOVERY <br />IS NOT REQUIRED, DO NOT INSTALL VAPOR <br />PIPING OR PENETRA-I-IONS, VAPOR SHEAR <br />VALVE, VAPOR STABILIZER KIT, AND FLEX <br />CONNECTOR. THESE ITEMS ARE NOT USED. <br />INTRINSICALLY SAFE BONDING. <br />INTRINSICALLY SAFE SYSTEMS APPARATUS <br />SHALL BE BONDED PER NEC 504,60. THIS <br />INCLUDES APPARATUS INSTALLED WITHIN THE <br />HAZARDOUS (CLASSIFIED) LOCATIONS AND <br />APPARATUS INSTALLED IN UNCLASSIFIED <br />LOCATIONS. <br />SENSOR CABLE: <br />SENSOR CABLE FROM DISPENSER JUNCTION <br />BOX SHOULD ONLY BE INSTALLED LONG <br />ENOUGH FOR THE SENSOR TO REST ON THE <br />BOTTOM OF THE SUMP IN THE TRUE <br />VERTICAL POSITION. <br />DISPENSER SUMP INSTALLATION: <br />FUEL INSTALLERS SHAD MOUNT THE <br />DISPENSER SUMP INSIDE OF THE STAINLESS <br />STEEL ISLAND FORM AS SHOWN IN DETAIL 6. <br />THE ISLAND FORMS SHALL BE MOUNTED AT <br />GRADE FOR PIPING INSPECTIONS USING STEEL <br />ANGLE IRON SUPPORT FRAMES. <br />Barghausen <br />Consulting Engineers, Inc. <br />18215 72nd Avenue South <br />Kent, WA 98032 <br />425.251.6222 <br />barghausen.com <br />BCE #20996 <br />■ <br />> <br />N <br />to <br />� a <br />i <br />F 0 <br />W <br />U <br />W <br />LL <br />U_ <br />0 <br />V) <br />z <br />0 <br />tI� <br />W <br />�..-----------'� � O <br />0 <br />V <br />b l <br />I <br />i <br />a <br />co 0 in 000 g <br />a, <br />��r�9 °° 3 "5 <br />C0 W <br />•° <br />"Q•E <br />z e;;; <br />()�>a <br />J* a <br />ova <br />U_ a'" <br />0 p® <br />ci ; V <br />U CNa00io <br />a C) I <br />iin <br />t-" 1 <br />0 r4moh <br />14i�.-.InM <br />a�C o <br />9/28/21 <br />V) <br />a z <br />� z <br />z <br />w <br />Ix <br />1'-2" 15 3" SINGLE WALL 140 141 1-1 /2" OR 2" DOUBLE <br />FIBERGLASS VAPOR WALL FLEXIBLE PIPING -► <br />RECOVERY PIPIN G*G& IN 4" ACCESS PIP F ' ; z <br />U <br />LLJ <br />4 m v <br />4 CONCRETE OR ASPHALT ° v o En"' 4 a: <br />!! z H W <br />v cL ;� <br />La <br />CIAIAJ ;z <br />Q Fo — <br />Z _ - Project #: 20996 Store #00852 <br />vEC= i //� Designed By. NTP <br />Drawn By. NTP <br />o �ft� /�`+�` •�`01�� /f\ Checked By: 0V <br />5 31» 4"' 41" 41" pate: 6-10-2021 <br />T8a1 6" 2 4" 2 4" 2 4' 2 6' NOTE- DOUBLE WALL <br />VAPOR USED ONLY Scale: 1" <br />3'—5" WHEN REOUIRED BY <br />LOCAL JURISDICTION Disk File: <br />TRENCH WIDTH BASED ON NUMBER PRODUCT USED Model: <br />SECTION VIEW - PIPE TRENCH AND COVER <br />42" WIDE DOUBLE <br />RADIUS PIPE GUARD <br />(1) 1" & (2) 3/4" CONDUIT W/ <br />CONDUIT W/ SEALOFFS ROUTED <br />THROUGH SUMP FRAME (TYP.) <br />SEE STAGE II <br />DESIGN NOTE <br />ON DETAIL #5 <br />SCALE: 1" V-0" <br />NOTE: DOUBLE WALL <br />VAPOR USED ONLY <br />WHEN REOUIRED BY <br />LOCAL JURISDICTION <br />SEE STAGE 11 <br />DESIGN NOTE <br />ON DETAIL #5 <br />Address: <br />4919 EVERGREEN WAY <br />EVERETT, WA 98203 <br />DISPENSER AND PIPING <br />DETAILS WAYNE OVATION 3+1 <br />OFC <br />FUE M FACL171f <br />Drawing No.: <br />T8. 1 <br />z <br />Q <br />z <br />n <br />07 <br />CD <br />N <br />N <br />N <br />CT <br />01 <br />.o <br />a� <br />- <br />fn <br />C <br />Q) <br />0. <br />0 <br />0 <br />0; <br />0) <br />0 <br />N <br />V) <br />a <br />0 <br />U <br />E <br />c0 <br />0) <br />CD <br />0 <br />c*t <br />0 <br />0 <br />C1) <br />__ <br />Is's <br />