GEOTECHNICAL RECOMMENDATIONS <br />THE FOLLOWING NOTES HAVE BEEN REFERENCED FROM THE REPORT TITLED <br />GEOTECHNICAL ENGINEERING REPORT QFC 852 FUEL STATION DATED JANUARY 7, <br />2020, CONDUCTED BY THE RILEY GROUP, INC. REFER TO THE COMPLETE REPORT <br />FOR ALL EARTHWORK REQUIREMENTS. <br />glum, <br />THE SITE IS <br />UNDERLAIN <br />BY UP TO FIVE FEET <br />OF VERY LOOSE FILL COMPRISED OF <br />SILTY SAND <br />WITH TRACE <br />GRAVEL OVER NATIVE <br />DEPOSITS OF MEDIUM DENSE TO VERY <br />DENSE SILTY <br />SAND WITH <br />TRACE GRAVEL, AND <br />SAND WITH VARYING AMOUNT OF SILT <br />AND GRAVEL <br />UP TO 20 <br />FEET. <br />SELTE -EREPARAT- __- LO N. <br />STRIPPING EFFORTS SHOULD INCLUDED REMOVAL OF PAVEMENTS, VEGETATION, <br />ORGANIC MATERIALS AND DELETERIOUS DEBRIS FROM AREAS SLATED FOR BUILDING, <br />PAVEMENT AND UTILITY CONSTRUCTION. <br />THE RILEY GROUP, INC. ANTICIPATED THAT SOME AREAS OF LOOSE SOIL MAY BE <br />PRESENT ON THE SITE AFTER STRIPPING. THEREFORE, ITS IS RECOMMEND THAT THE <br />BUILDING, PAVEMENT, AND OTHER AREAS TO RECEIVE STRUCTURAL AREAS ARE <br />PROOFROLLED AND COMPACTED. SOILS SHOULD BE COMPACTED TO ACHIEVE A <br />MINIMUM COMPACTION LEVEL OF 95 PERCENT OF THE MODIFIED PROCTOR MAXIMUM <br />DRY DENSITY AS DETERMINED BY ASTM D1557 TEST METHOD. PROOFROLLING AND <br />ADEQUATE SUBGRADE COMPACTION CAN ONLY BE ACHIEVED WHEN THE SOILS ARE <br />WITHIN APPROXIMATELY :F 2 PERCENT MOISTURE CONTENT OF THE OPTIMUM <br />MOISTURE CONTENT. <br />SUBGRADE SOILS THAT BECOME DISTURBED DUE TO ELEVATED MOISTURE CONDITIONS <br />SHOULD BE OVEREXCAVATED TO REVEAL FIRM, NON -YIELDING, NON -ORGANIC SOILS <br />AND BACKFILLED WITH COMPACTED STRUCTURAL FILL. THE RILEY GROUP, INC. <br />RECOMMENDS THAT THE EARTHWORK PORTION OF THIS PROJECT BE COMPLETED <br />DURING EXTENDED PERIODS OF WARM AND DRY WEATHER IF POSSIBLE, <br />EXCAVATIONS AND FILL <br />FOR EXCAVATION MORE THAN 4 FEET BUT LESS THAN 20 FEET IN DEPTH, THE <br />TEMPORARY SIDE SLOPES SHOULD BE LAID BACK WITH A MINIMUM SLOPE <br />INCLINATION OF 1.5:1 (HORIZONTALVERTICAL), IF THERE IS INSUFFICIENT ROOM TO <br />COMPLETE THE EXCAVATIONS IN THIS MANNER, OR EXCAVATIONS GREATER THAN 20 <br />FEET IN DEPTH ARE PLANNED, TEMPORARY SHORING SHOULD BE USED. FOR OPEN <br />CUTS AT THE SITE THE RILEY GROUP, INC. RECOMMENDS THE FOLLOWING: <br />NO TRAFFIC, CONSTRUCTION EOUIPMENT, STOCKPILES OR BUILDING SUPPLIES <br />ARE ALLOWED AT THE TOP OF CUT SLOPES WITHIN A DISTANCE OF AT LEAST 5 <br />FEET FROM THE TOP OF THE CUT. <br />- EXPOSED SOIL ALONG THE SLOPE IS PROTECTED FROM SURFACE EROSION <br />USING WATERPROOF TARPS AND/OR PLASTIC SHEETING. <br />- CONSTRUCTION ACTIVITIES ARE SCHEDULED SO THAT THE LENGTH OF TIME THE <br />TEMPORARY CUT IS LEFT OPEN IS MINIMIZED <br />- SURFACE WATER IS DIVERTED AWAY FROM THE EXCAVATION <br />- THE GENERAL CONDITION OF SLOPES SHOULD BE OBSERVED PERIODICALLY BY <br />A GEOTECHNICAL ENGINEER TO CONFIRM ADEQUATE STABILITY AND EROSION <br />CONTROL MEASURES. <br />THE RILEY GROUP, INC. RECOMMENDS FILL BELOW THE FOUNDATION AND FLOOR <br />SLAB, AND BELOW PAVEMENT AND HARDSCAPE SURFACES BE PLACED IN <br />ACCORDANCE WITH THE FOLLOWING RECOMMENDATION FOR STRUCTURAL FILL. THE <br />SANDY NATIVE SOILS MAY BE SUITABLE FOR STRUCTURAL FILL IF THE MOISTURE CAN <br />BE PROPERLY CONTROLLED AT THE TIME OF COMPACTION IF THE CONSTRUCTION <br />CLEAN, <br />OCCURS IN DRY WEATHER. IF NOT, IT MAY BE NECESSARY TO IMPORT <br />GRANULAR SOILS THAT MEETS THE GRADING REQUIREMENT IN THE GEOTECHNICAL <br />REPORT, STRUCTURAL FILL MATERIALS SHOULD BE PLACED 1114 UNIFORM LOOSE <br />LAYERS NOT EXCEEDING 12 INCHES AND COMPACTED AS SPECIFIED IN THE <br />GEOTECHNICAL REPORT. <br />GROUNDWATER: <br />GROUNDWATER WAS NOT ENCOUNTERED DURING THE SUBSURFACE EXPORTATION,, IT <br />SHOULD BE RECOGNIZED THAT FLUCTUATION OF THE GROUNDWATER TABLE WILL <br />OCCUR DUE TO SEASONAL VARIATION. IN ADDITION, PERCHED WATER CAN DEVELOP <br />WITHIN SEAMS AND LAYERS CONTAINED IN FILL SOIL OR HIGHER PERMEABILITY SOILS <br />OVERLYING LESS PERMEABLE SOILS FOLLOWING PERIODS OF HEAVY OR PROLONGED <br />PRECIPITATION. <br />ACCESS113LE PATH OF TRAVEL NOTE - <br />WALKWAYS ALONG ACCESSIBLE ROUTES OF TRAVEL SHALL BE <br />CONTINUOUSLY ACCESSIBLE, BE A MINIMUM OF 44" IN WIDTH, HAVE <br />A MAXIMUM 2.0% CROSS SLOPE, AND SHALL HAVE RAMPS <br />COMPLYING WITH ACCESSIBILITY STANDARDS (SECTION 405) WHERE <br />NECESSARY TO CHANGE ELEVATION AT A LONGITUDINAL SLOPE <br />EXCEEDING 5% (1:20). <br />PROPERTY PROTECTION NOTE: <br />THE CONTRACTOR SHALL PROTECT AND PRESERVE FROM DAMAGE, INTERFERENCE AND <br />DESTRUCTION ALL. PRIVATE AND PUBLIC PROPERTY ON OR IN THE VICINITY OF THE WORK. IF <br />SUCH PROPERTY IS DAMAGED OR DESTROYED OR ITS USE INTERFERED WITH BY THE CONTRACTOR <br />OR HIS OR HER AGENTS, IT SHALL BE RESTORED IMMEDIATELY TO ITS FORMER CONDITION BY THE <br />CONTRACTOR AT HIS OR HER EXPENSE AND SUCH INTERFERENCE TERMINATED. <br />EASEMENT NOTE, <br />THE LOCATION OF THE EASEMENTS SHOWN ON THIS SHEET SET WERE ADDED BASED ON THE <br />INFORMATION INCLUDED IN THE TITLE REPORT UNDER FIRST AMERICAN TITLE INSURANCE <br />COMPANY NO. NCS-1067959-OR1, DATED MAY 12, 2021. THESE EASEMENTS WERE NOT <br />SURVEYED, THEREFORE BARGHAUSEN CONSULTING ENGINEERS DOES NOT GUARANTEE THE <br />ACCURACY OF EASEMENT LOCATIONS SHOWN ON THESE FLANS. <br />APPROXIMATE LOCATION OF EXISTING UTILITIES ARE SHOWN ON THESE PLANS. CONTRACTOR TO <br />COORDINATE WITH PURVEYORS AND USE EXTREME CAUTION WHEN EXCAVATING ON -SITE, UNTIL <br />EXISTING GAS AND POWER SERVICE LOCATIONS ARE CONFIRMED. CONTRACTOR TO ORDER <br />INDEPENDENT UTILITY LOCATES (INCLUDING GAS AND POWER) FOR THE FULL SCOPE OF WORK <br />PRIOR TO CONSTRUCTION OR ANY GROUND DISTURBING ACTIVITIES. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH <br />OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE <br />UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS <br />SHALL INCLUDE CALLING UTILITY LOCATE 0 811 AND THEN POTHOLING ALL OF THE EXISTING <br />UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT <br />CONFLICTS EXIST, LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON <br />THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD <br />OCCUR, THE CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE <br />ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. <br />1, ALL SPOT ELEVATIONS SHOWN ARE TO FINISH SURFACE (TOP OF ASPHALT OR TOP OF CONCRETE <br />PAVEMENT, NOT TOP OF CURB/SIDEWALK) UNLESS OTHERWISE NOTED. (-1,4, = TOP OF ASPHALT, TC <br />TOP OF CONCRETE SIDEWALK/CURB, ME = MATCH EXISTING ELEVATIONS, FC = FLUSH CURB, FL <br />FLOW LINE, GB m GRADE BREAK) <br />2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL PROPOSED GRADES IN RELATIONSHIP TO <br />SURVEYED BASIS OF ELEVATION. <br />1 FILL MATERIAL AND COMPACTION SHALL CONFORM TO THE GEOTECHNICAL REPORT AND CITY OF EVERETT <br />REQUIREMENTS, <br />4, CONTRACTOR TO PROTECT AND MAINTAIN EROSION CONTROL FACILITIES DURING GRADING OPERATIONS. <br />5. CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT AND CITY <br />OF EVERETT REQUIREMENTS. <br />6, CONTRACTOR TO RAISE AND ADJUST PROPOSED SANITARY SEWER CLEANOUTS LIDS TO FINAL GRADE AS <br />NECESSARY. CLEANOUTS WITHIN ADA ACCESSIBLE PATHS SHALL BE ADJUSTED TO FINAL ELEVATIONS IN <br />COMPLIANCE WITH CURRENT ADA REQUIREMENTS. <br />7. CONTRACTOR TO RAISE AND ADJUST ALL EXISTING AND PROPOSED CATCH BASIN RIMS TO FINAL GRADE <br />AS NECESSARY. CATCH BASINS WITHIN ADA ACCESSIBLE PATHS SHALL BE ADJUSTED TO FINAL <br />ELEVATIONS IN COMPLIANCE WITH CURRENT ADA STANDARDS. <br />8. CONTRACTOR TO ORDER LOCATES AND FIELD VERIFY ALL UTILITIES PRIOR TO CONSTRUCTION TO ENSURE <br />THAT UTILITY CONFLICTS DO NOT EXIST. CONTRACTOR TO REVIEW UTILITY ASBUILTS IN ORDER TO VERIFY <br />EXISTING UTILITY LOCATIONS, CONTRACTOR SHALL POTHOLE ALL POTENTIAL UTILITY CONFLICTS PRIOR TO <br />CONSTRUCTION. NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. OF ANY CONFLICTS, <br />GRADING LEGEND., <br />PROPOSED CONTOUR <br />EXISTING CONTOUR <br />PROPOSED RIDGE LINE <br />SWALE FLOWLINE <br />PROPOSED GRADING SLOPE <br />SPOT ELEVATION <br />FLUSH ELEVATION <br />MATCH EXISTING ELEVATION <br />TOP OF PAVEMENT/TOP OF CURB <br />FLOW/GUTTER LINE/TOP OF CURB <br />- - - - - - 30 - - - - - - <br />1.00% <br />30.01 F _fC <br />_30.Q1 TA <br />30.51 TC <br />Q.QLI FL <br />Sec. 31, Twp. 29N, Rge. 5E, W.M. <br />L02J <br />302,97 Z <br />30,3.05/ I 0 <br />302'.95 <br />b <br />303.04 1.6 302 <br />0. 302. <br />6\" v <br />�'? <br />,3�02.95 <br />02.99 0 5% <br />a-m I <br />I .2 302.94 <br />aft Ift aft <br />, 0 p q <br />111 :i Mill � 1� <br />p!! <br />hmx�iiiiiiii;i <br />�73 06 2. 95 <br />302.0'\ <br />0 . <br />30 .92 <br />Know what's below. <br />Call before you dig. <br />Dial 811 <br />Barg.hausen <br />Consulting Engineers, Inc. <br />18215 72nd Aven Lie So u-th <br />Kent, VVA 98032 <br />4' 25.251.6222 <br />baq ,ghausenxam <br />BCE #2_09,96 <br />'I <br />U-) <br />z <br />0 <br />Ld <br />E <br />cn <br />Z. <br />M <br />z <br />� CU ) (D 0 <br />LL =2z <br />cy< <br />0 CM,6 00 <br />'zo to <br />(-,I CN <br />(D -r, f-, V) <br />CFJ r_ al CIA r­. <br />S <br />A S11 <br />2 8 52 7 <br />1,T Q, <br />;eZ01VA L �tY <br />am <br />10/15/21 <br />Project 20996 Store #00852 <br />Designee By, MU vv <br />< <br />Drown By, ADW <br />Checked By, CJR <br />Dote: 10-15-2021 <br />CD <br />C\1 <br />Scole: 1 <br />Disk File: 20996—GD.dwg <br />Model: <br />Address- <br />4919 EVERGREEN WAY <br />00 <br />EVERETT, 14% 98203 0-) <br />Drawing No.: 0 <br />cv <br />CD <br />CD <br />CD <br />C 4.1 of 16 <br />