Laserfiche WebLink
C <br />a <br />SUBMIT FOR BUILDING PERMIT - 24 MAY 18 <br />05 OCT 18 - REVISED PER CITY REVIEW LETTER <br />q(--IOC <br />_,If 42' <br />(TYPE I'D" UNIT OPTION 1313ATHROOM <br />AN51 1 17.1-2009 5EC. 1004 <br />ARCHITECT TO REVIEW BATHING FIXTURE SUBMITTAL <br />PRIOR TO FRAMING TO CONFIRM COMPLIANCE. <br />k <br />(TYPE "B" UNIT) <br />9195Q/FT <br />3 UNIT5 <br />DEMPATIO - 4G 5Q/FT <br />UNITS # 1 13, 213 ' 13 <br />BATHROOM(TYPE "13' UNIT OPTION B <br />PROVIDE BACKING FOR GRAB BARS IN ALL BATHROOM UNITS AS SHOWN ON SHEET AG. I * AG.2. <br />ALL TOILETS SHALL BE CENTERED EXACTLY 18 INCHES FROM FACE OF FINISHED SIDE WALL. <br />r <br />PROVIDE ACCESSIBLE CONTROLS FOR POWER AND SPEED AT WALL MOUNTED CONTROLS. <br />ENSURE THAT CONTROLS ARE NOT LOWER THAN 15" AND AT TYPE "A" UNITS THAT THE CONTROLS DO NOT <br />REQUIRE TWISTING OR GRIPPING. <br />BALCONIES FOR TYPE "A" UNITS MUST HAVE GO" CLEAR FOR A TURNING SPACE. <br />OPERABLE WINDOWS MUST BE ACCESSIBLE WITH ACCESSIBLE CONTROLS WITHIN REACH RANGE. <br />FOR TYPE "A" UNITS ALL CONTROLS MUST BE ACCESSIBLE (LEVER STYLE OR SIMILAR) WHICH INCLUDES OPERABLE <br />WINDOWS, SINK AND LAVATORY FAUCETS, KITCHEN CABINET DOOR HARDWARE, AND DOOR HARDWARE. <br />FOR TYPE "A" UNITS AND A PORTION OF ALL STORAGE CLOSETS MUST BE ACCESSIBLE. ENSURE THAT A PORTION <br />OF A CLOSET POLE IS MOUNTED NO GREAT ER THAN 4G INCHES AFF. <br />FOR TYPE "A" UNIT PROVIDE A SINK WITH A DRAIN AT THE BACK OF THE BOWL SO THAT DRAIN PIPES AND <br />DISPOSAL UNITS ARE OUT OF THE KNEE CLEARANCE SPACE. <br />PROVIDE COUNTER TOP MICROWAVE FOR TYPE "A" UNITS <br />FOR ALL UNi —15 PROVIDE A PORTION OF TOWEL BARS MOUNT AI 48" AFF. <br />FOR TYPE "A" UNITS THE KITCHEN CORNER OUTLETS MINIMUM 3G" FROM INSIDE CORNER OF WALL SURFACE IN "L" <br />AND "U" SHAPED KITCHENS. WHERE RANGE PROJECTS MORE THAN 24" THE ACCESSIBLE OUTLET IN THE CORNER <br />IS CALCULATED BY APPLIANCE DEPTH DIMENSION PLUS 1 2". WHERE TWO OR MORE RECEPTACLE OUTLETS ARE <br />PROVIDED IN A KITCHEN ABOVE A LENGTH OF COUNTERTOP THAT IS UNINTERRUPTED BY A SINK OR APPLIANCE, <br />ONE RECEPTACLE OUTLET SHALL NOT BE REQUIRED TO COMPLY WITH (CC/ANSI A 1 1 7. 1 -2009 SECTION 309. <br />FOR TYPE "B" UNITS THE KITCHEN CORNER OUTLETS MINIMUM 30 FROM INSIDE CORNER OF WALL SURFACE IN "L" <br />AND "U" SHAPED KITCHENS. WHERE RANGE PROJECTS MORE THAN 25 1/2" THE ACCESSIBLE OUTLET IN THE <br />CORNER 15 CALCULATED BY APPLIANCE DEPTH DIMENSION PLUS 1 2". WHERE TWO OR MORE RECEPTACLE <br />OUTLETS ARE PROVIDED IN A KITCHEN ABOVE A LENGTH OF COUNTERTOP THAT 15 UNINTERRUPTED BY A SINK OR <br />APPLIANCE, ONE RECEPTACLE OUTLET SHALL NOT BE REQUIRED TO COMPLY WITH ICC/ANSI A I 1 7. 1-2003 <br />SECTION 309. <br />FOR TYPE "A" UNIT PROVIDE COMBINATION WA5HER/DRYEK. PROVIDE FOR PARALLEL APPROACH. CLEAR FLOOR <br />SPACE SHALL BE CENTERED ON APPLIANCE. <br />OPERABLE PARTS INCLUDING DOORS, LINT SCREEN, DETERGENT AND BLEACH <br />COMPARTMENTS SHALL BE NO LOWER THAN 15" ABOVE F.F. AND NOT MORE THAN 40" <br />ABOVE F.F. <br />TYPE "A" KITCHEN COUNTERTOP 24" MAX. DEPTH, 34" MAX. HEIGHT (TOP OF SINK OR COUNTER WHICHEVER IS <br />HIGHEST). <br />TYPE "B" KITCHEN COUNTERTOP 25 1/2" MAX. DEPTH, 3G" MAX. HEIGHT (TOP OF SINK OR COUNTER WHICHEVER <br />15 HIGHEST). <br />TYPE "A" * "D" BATHROOM COUNTERTOP 24" MAX. DEPTH, 34" MAX. HEIGHT (TOP OF SINK OR COUNTER <br />WHICHEVER IS HIGHEST). <br />FOR TYPE "B" UNITS A 5 T ACKABLE WA5HER/DKYER COMBINATION CAN BE PROVIDED. <br />C <br />a <br />n <br />SHEET NOTES <br />©SELF -RIMING STAINLESS STEEL SINK; SINGLE BOWL; SINGLE LEVER <br />FAUCET. ENSURE KNEE CLEARANCE AT 27" AFF IN TYPE "A" UNITS <br />® BUILT-IN DISHWASHER, ENERGY STAR <br />® 30" ELECTRIC RANGE WITH MICROWAVE/HOOD FAN ABOVE <br />® 30" ELECTRIC RANGE WITH HOOD FAN ABOVE <br />® REFRIGERATOR SPACE <br />PLASTIC LAMINATE COUNTERTOP WITH 4" WATERFALL BACKSPLASH <br />i AND 13ULLN05E FRONT EDGE; CABINETS BELOW <br />® LINE OF CABINETS ABOVE <br />® PONY WALL <br />METAL CARPET STRIP @ CARPET/VINYL TRANSITION <br />O 30X24 WORK AREA @ MAX 34" HEIGHT - OPEN BELOW <br />1.28 GAL. MAXIMUM FLUSH WATER CLOSET; ROUND BOWL; PROVIDE IN SPACE <br />MINIMUM 3G" WIDE IN ACCESSIBLE UNITS, MINIMUM 33" WIDE IN ADAPTABLE UNITS <br />FI-2-1 GRAB BARS FOR WATER CLOSET <br />3 RECE55ED TOILET PAPER DISPENSER, MOUNT BOT OOM MIN 15" AFF * TOP MAX 33" AFF <br />I �I PORCELAIN OVER STEEL LAVATORY; SINGLE LEVER 1.5 GPM FAUCET AND CABINET <br />5 SURFACE MOUNTED MIRROR WITH J-CLIP5 TO MATCH VANITY <br />30" TOWEL BAR; PROVIDE SOLID BACKING IN WALL; MOUNT CENTER OF BAR <br />MAX. 4'-G" AFF. IN ALL UNITS MOUNT A PORTION OF TOWEL BARS @ 46" AFF <br />17 FIBERGLASS TUB WITH PLASTIC LAMINATE SURROUND: TOP OF SURROUND <br />MINIMUM 72" ABOVE FLOOR; PROVIDE WITH BATH CURTAIN ROD <br />FI 8 SHOWER HEAD 1.75 GPM ; MOUNT 4" ABOVE TOP OF SURROUND <br />9 FURR WALL TO TUB ENCLOSURE; VERIFY DIMENSIONS <br />2O 5' SHOWER <br />2 I SHOWER SEAT <br />22 SHOWER SPRAY UNIT 1.75 GPM, WITH A HOSE AT LEAST GO" LONG, THAT CAN BE USED <br />AS A FIXED5HOWER HEAD OR AS A HAND HELD SHOWER <br />23 GRAB BAPS FOR TUB OR ROLL -IN SHOWER <br />24 STACKED WA5HER/DRYER W/ VENT TO THE EXTERIOR (80 CFM), ENERGY STAR <br />�� COMBINATION WA5HER/DRYER W/ VENT TO EXTERIOR (50 CFM), ENERGY STAR <br />2� I - 1 2" SHELF � POLE (PREFiN15HED) <br />27 5 - 1 2" SHELVES (PREFINI5HED) <br />[2-8-1 4' SHOWER <br />29 ADA 3' TRANSFER TYPE SHOWER WITH SEAT <br />O ADA 5' ROLL -IN SHOWER WITH SEAT <br />(TYPE "A'' UNIT) <br />653 5Q/I`T <br />I UNIT <br />DECPPATIO 51 5Q/iT <br />UNIT # 102 <br />SEE SHEET AG. I INTERIOR ELEVATIONS FOR LOCATION <br />OF GRAB BARS AND BACKING. ALSO NOTE LOCATION <br />OF WAI ER CLOSETS AND TUB CONTROLS <br />NOTE: ALL DOORS TO BE 3'-0"X 0-8" <br />UNIT ENTRY DOORS TO BE 20 MIN RATED <br />AND BE EQUIPPED WITH VIEWER � DEAD BOLT LOCK <br />ALL HARDWARE TO HAVE LEVER LOCK5ET5 <br />PUBLIC 51TE OF THE UNIT PRIMARY ENTRANCE PER ANSI SECTION 1005.5. 1 <br />A MEANS FOR VISUALLY IDENTIFYING A VISITOR WITHOUT OPENING THE UNIT <br />ENTRY DOOR SHALL BE PROVIDED PER ANSI SECTION 1005.5.2 <br />NOTE: ALL BATHS � KITCHENS TO BE MECHANICALLY VENTED TO EXT ERIOR <br />NOTE: PROVIDE REMOVABLE CABINET IN ALL BATHROOM AND SUPPORT AT OPEN END <br />PROVIDE FINISH FLOOR UNDER REMOVABLE CABINET <br />ALL UNITS NOT DE51GNAi ED AS TYPE "A" SHALL BE TYPE "B' UNITS <br />ALL TYPE "A" UNITS SHALL MEET THE REQUIREMENTS OF (CC/ANS( A 1 1 7. 1 -2009 <br />OUTLETS TO BE NO LOWER THAN 15" HIGH MEASURED FROM CENTERLINE OF LOWEST <br />OUTLET TO THE FINISH FLOOR. <br />COUNTER TOP OUTLET5 TO BE MAXIMUM 44" HIGH MEASURED FROM FINISHED FLOOR TO <br />HIGHEST OUTLET. <br />SWITCHES AND THERMOSTATS MAXIMUM 46" TO THE HIGHEST CONTROLS. <br />KITCHEN CORNER OUTLETS MUST BE A MINIMUM 3G FROM INSIDE CORNER OF WALL <br />SURFACE IN L-5HAPE AND U-SHAPE KITCHENS. <br />NOTE: ALL WINDOWS TO BE DOUBLE GLAZED VINYL FRAME W/ACCE55115LE CONTROLS <br />WINDOWS W/.28 "U" FACTOR � .40 SHGC <br />L <br />VEKII Y WALL TYPES AS PER KA1 . 1 SHEET <br />STANDARD WALL ( I HP)(SEE SHT RA 1. 1 #3) <br />CORRIDOR WALL (SEE SHT RA 1. 1 #4) <br />PLUMBING CORRIDOR WALL (SEE SHT RA I , 1 #4) <br />UNIT PARTITION WALL (SEE SHT RA 1. 1 #5) <br />EXTERIOR WALL (SEE SHT RA 1. 1 # I ) <br />zzm 2 HP WALL - GENERIC (SEE SHT RA I. I #G) <br />2 H R WALL - (STC 50) (SEE SHT RA 1 .2 #20) <br />2 HR EXTERIOR WALL (SEE SHT RA 1 .2 # 1 9) <br />AREA SEPARATION FIRE WALL - (SEE SHT RA 1. 1 -#7) <br />EXTERIOR WALL - FIRE BOTH SIDES (SEE SHT RA 1. 1 #2) <br />WINDOW INDICATOP <br />3Pc DOOR INDICATOR <br />SOFFITS FOP DUCTS <br />®5 9 DETAIL INDICATOR (SEE D 1 SHTS) <br />6, INTERIOR ELEVATIONS (SEE SHT AG. 1) <br />sA SMOKE DETECTORS <br />c0 CARBON MONOXIDE DETECTOR <br />TL-", REGISTERED <br />ARCHITECT <br />alm rrorw F <br />CHARLES E. MORGAI <br />STATE OF WASHINGTON <br />DATE 24 MAY 18 1' <br />RESUBMIT <br />RESUBMIT <br />