ACCESSIBLE ROUTES - ICC/ANSI Al 17.1-2009 CHAPTER 4 <br />WATER CLOSETS - ICC/ANSI Al 17.1-2009 SECTION 604 <br />BATHTUBS ICC/ANSI Al 17.1 -2009 SECTION 607 <br />ALARMS ICC/ANSI Al 17.1-2009 SECTION 702 <br />THE MINIMUM CLEAR WIDTH OF AN ACCESSIBLE ROUTE OF TRAVEL SHALL BE 36 <br />INCHES EXCEPT AT DOORS. WHERE AN ACCESSIBLE ROUTE INCLUDES A 180 <br />DEGREE TURN AROUND AN OBSTRUCTION WHICH IS LESS THAN 48 INCHES IN <br />WIDTH, THE CLEAR WIDTH OF THE ACCESSIBLE ROUTE OF TRAVEL AROUND THE <br />OBSTRUCTIONS SHALL BE 42_ INCHES MIN. <br />WHERE AN ACCESSIBLE ROUTE OF TRAVEL IS LESS THAN 60 INCHES IN WIDTH, <br />PASSING SPACES AT LEAST 60 INCHES BY 60 INCHES SHALL BE LOCATED AT <br />INTERVALS NOT TO EXCEED 200 FEET. A T-SHAPED INTERSECTION OF TWO <br />CORRIDORS OR WALKS MAY BE USED AS A PASSING SPACE. <br />ACCESSIBLE ROUTES SHALL HAVE CLEAR HEIGHT OF NOT LESS THAN 7'6" <br />PER IBC SEC. 1003.2 EXCEPT AT DOOR WAYS, WHICH ARE PERMITTED TO <br />HAVE A CLEARANCE OF 78 INCHES MINIMUM CLEAR HEIGHT. <br />PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND <br />80 INCHES ABOVE THE FLOOR SHALL NOT EXCEED 4 INCHES. <br />AN ACCESSIBLE ROUTE OF TRAVEL SHALL HAVE A RUNNING SLOPE NOT <br />GREATER THAN 1 VERTICAL IN 20 HORIZONTAL. CROSS SLOPES OF AN <br />ACCESSIBLE ROUTE OF TRAVEL SHALL NOT EXCEED 1 VERTICAL IN 48 <br />HORIZONTAL. ICC/ANSI Al 17.1-2009, SECTION 403.3. <br />PASSENGER TRANSIT PLATFORM EDGES BORDERING A DROP-OFF AND NOT <br />PROTECTED BY PLATFORM SCREENS OR GUARDS SHALL HAVE A DETECTABLE <br />WARNING. CURB RAMPS SHALL HAVE DETECTABLE WARNINGS. IBC/WA STATE <br />AMENDMENTS SECTION 110.9.9. <br />ILLUMINATION SHALL BE PROVIDED ALONG AN EXTERIOR ACCESSIBLE ROUTE <br />OF TRAVEL AT ANY TIME THE BUILDING IS OCCUPIED, WITH AN INTENSITY OF <br />NOT LESS THAN ONE FOOT-CANDLE ON THE SURFACE OF THE ROUTE.' <br />IBC SECTION 1006. <br />TRANSITIONS FROM RAMPS TO WALKS, GUTTERS, OR VEHICULAR WAYS SHALL <br />BE FLUSH AND FREE OF ABRUPT CHANGES IN HEIGHT, MAXIMUM SLOPES OF <br />ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO THE <br />CURB RAMP OR ACCESSIBLE ROUTE OF TRAVEL SHALL NOT EXCEED 1 VERTICAL <br />IN 20 HORIZONTAL. <br />CURB RAMPS SHALL BE NOT LESS THAN 36 INCHES IN WIDTH, EXCLUSIVE OF <br />FLARED SIDES. <br />PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF A ROUTE OF <br />TRAVEL OR MANEUVERING SPACE. ANY WALL OR POST MOUNTED OBJECT WITH <br />ITS LEADING EDGE BETWEEN 27 AND 80 INCHES ABOVE THE FLOOR MAY <br />PROJECT NOT MORE THAN 4 INCHES INTO A ROUTE OF TRAVEL, CORRIDOR, <br />PASSAGEWAY OR AISLE. ANY WALL OR POST MOUNTED PROJECTION GREATER <br />THAN 4 INCHES SHALL EXTEND TO THE FLOOR. <br />THE MAXIMUM SLOPE OF A RAMP SHALL BE 1 VERTICAL IN 12 HORIZONTAL. THE <br />MAXIMUM RISE FOR ANY RUN SHALL BE 30 INCHES. <br />THE MINIMUM WIDTH OF A RAMP SHALL BE NOT LESS THAN 36 INCHES. <br />RAMPS WITHIN THE ACCESSIBLE ROUTE OF TRAVEL SHALL HAVE LANDINGS AT <br />THE TOP AND BOTTOM, AND AT LEAST ONE INTERMEDIATE LANDING SHALL BE <br />PROVIDED FOR EACH 30 INCHES OF RISE. LANDING SHALL BE LEVEL AND HAVE <br />A MIN. DIMENSION MEASURED IN THE DIRECTION OF RAMP RUN OF NOT LESS <br />THAN 60 INCHES. WHERE THE RAMP CHANGES DIRECTION AI A LANDING, THE <br />LANDING SHALL BE NOT LESS THAN 60 INCHES BY 60 INCHES. THE WIDTH OF <br />ANY LANDING SHALL BE NOT LESS THAN THE WIDTH OF THE RAMPS. <br />RAMP RUNS WITH A RISE GREATER THAN 6 INCHES SHALL HAVE HANDRAILS <br />AS REQUIRED FOR STAIRWAY. HANDRAILS SHALL BE CONTINUOUS PROVIDED <br />THAT THEY SHALL NOT BE REQUIRED AT ANY POINT OF ACCESS ALONG <br />THE RAMP, NOR AT ANY CURB RAMP. HANDRAILS SHALL EXTEND AT LEAST <br />12 INCHES BEYOND THE TOP AND BOTTOM OF ANY RAMP RUN. <br />DOORS SHALL BE CAPABLE OF BEING OPENED SO THE CLEAR WIDTH OF <br />OPENING IS NOT LESS THAN 32 INCHES. <br />PRIMARY ENTRANCE DOOR TO THE UNIT, AN ALL OTHER DOORWAYS INTENDED <br />FOR USER PASSAGE, SHALL HAVE A CLEAR WIDTH OF OPENING NOT LESS THEN 32 INCHES. <br />ALL DOORS IN COMMON USE AREAS, TYPE A UNITS & ENTRANCE DOORS TO <br />TYPE B UNITS HALL HAVE A MINIMUM MANEUVERING CLEARANCES AS <br />FOLLOWS: <br />NOTE DOORS WITHIN A TYPE "B" UNIT DO NOT NEED TO HAVE THE REQUIRED <br />CLEARANCES. <br />FOR A FORWARD APPROACH, WHERE A DOOR MUST BE PULLED TO BE OPENED, <br />AN UNOBSTRUCTED FLOOR SPACE SHALL EXTEND AT LEAST 18 INCHES BEYOND <br />THE STRIKE JAMB AND EXTEND AT LEAST 60 INCHES PERPENDICULAR TO THE <br />DOORWAY. <br />FOR A FORWARD APPROACH, WHERE A DOOR MUST BE PUSHED TO BE OPENED <br />AND IS EQUIPPED WITH A CLOSER AND A LATCH, AN UNOBSTRUCTED FLOOR <br />SPACES SHALL EXTEND 12 INCHES BEYOND THE STRIKE JAMB AND EXTEND AT <br />LEAST 48 INCHES PERPENDICULAR TO THE DOORWAY. <br />FOR A FORWARD APPROACH, WHERE A DOOR MUST BE PUSHED TO BE OPENED <br />AND IS NOT EQUIPPED WITH A CLOSER AND A LATCH, AN UNOBSTRUCTED <br />FLOOR SPACE SHALL BE AT LEAST THE WIDTH OF THE DOORWAY AND EXTEND <br />AT LEAST 48 INCHES PERPENDICULAR TO THE DOORWAY. <br />WHERE TWO DOORS ARE IN SERIES, THE MINIMUM DISTANCE BETWEEN TWO <br />HINGED OR PIVOTED DOORS SHALL BE 48 INCHES, IN ADDITION TO ANY AREA <br />NEEDED FOR DOOR SWING. DOORS IN SERIES SHALL SWING EITHER IN THE <br />SAME DIRECTION, OR AWAY FROM THE SPACE BETWEEN THE DOORS. THE <br />SPACE BETWEEN THE DOORS SHALL PROVIDE A TURNING SPACE COMPLYING <br />WITH ICC/ANSI Al 17.1 -2009 SECTION 304. <br />ALL DOORS IN ALCOVES SHALL COMPLY WITH THE REQUIREMENT FOR A <br />FORWARD APPROACH. <br />DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION <br />OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION <br />OF 12 DEGREES SHALL BE 5 SECONDS MINIUMUM. <br />PUSH SIDE OF DOOR BOTTOMS TO BE 10" MIN AFF OF SWING DOORS IN A SMOOTH <br />SURFACE AT ALL TYPE A UNITS, COMMON AREA DOORS AS WELL AS GATES, TYPE B <br />ENTRY (NOT APPLICABLE WHERE USED AT TYPE B INTERIOR DOORS). <br />WHERE A DOOR CONTAINS ONE OR MORE VISION PANELS, THE BOTTOM OF THE <br />GLASS OF AT LEAST ONE PANEL, SHALL BE NOT MORE THAN 43 INCHES ABOVE <br />ALL PUBLIC RESTROOMS SHALL HAVE UNOBSTRUCTED FLOOR SPACE OF <br />SUFFICIENT SIZE TO INSCRIBE A CIRCLE WITH A DIAMETER OF NOT LESS THAN <br />60 INCHES. DOORS IN ANY POSITION MAY ENCROACH INTO THIS SPACE <br />THE CLEAR FLOOR SPACES AT FIXTURES, THE ACCESSIBLE ROUTE OF TRAVEL, <br />AND THE UNOBSTRUCTED FLOOR SPACE MAY OVERLAP. <br />ALTERNATE: T-SHAPED SPACE AS SHOWN ON SHEET A0.4 <br />5UBMIT FOR BUILDING PERMIT - 24 MAY 18 <br />05 OCT 18 - REVISED PER CITY REVIEW LETTER <br />THE CENTERLINE OF THE WATER CLOSET SHALL BE 18 INCHES FROM THE SIDE <br />WALL OR PARTITION. A CLEARANCE AROUND A WATER CLOSET 60 INCHES <br />MINIMUM, MEASURED PERPENDICULAR FROM THE SIDEWALL, AND 56 INCHES <br />MINIMUM FOR A WALL MOUNTED FIXTURE AND 59 INCHES MINIMUM FOR A <br />FLOOR MOUNTED FIXTURE MEASURED PERPENDICULAR FROM THE REAR WALL <br />MEASURED PERPENDICULAR FROM THE REAR WALL SHALL BE PROVIDED. <br />A LAVATORY MAY BE LOCATED WITHIN THE CLEAR FLOOR SPACE REQUIRED <br />FOR A WATER CLOSET PROVIDED THAT KNEE AND TOE CLEARANCES FOR THE <br />LAVATORY ARE PROVIDED, IN DWELLING UNITS ONLY. <br />THE HEIGHT OF WATER CLOSETS SHALL BE A MINIMUM OF 17 INCHES AND A <br />MAXIMUM OF 19 INCHES MAXIMUM ABOVE THE FLOOR, MEASURED TO THE TOP <br />OF THE SEAT. SEATS SHALL NOT BE SPRING TO RETURN TO A LIFTED POSITION. <br />GRAB BARS SHALL BE INSTALLED PROVIDED ON THE REAR WALL AND ON THE <br />SIDE WALL CLOSEST TO THE WATER CLOSET. FIXED SIDEWALL GRAB BARS SHALL <br />BE 42 INCHES MINIMUM IN LENGTH, LOCATED 12 INCHES MAXIMUM FROM THE <br />REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL. IN <br />ADDITION, A VERTICAL GRAB BAR 18 INCHES MINIMUM IN LENGTH SHALL BE <br />MOUNTED WITH THE BOTTOM OF THE BAR LOCATED BETWEEN 39 INCHES AND <br />41 INCHES ABOVE THE FLOOR, AND WITH THE CENTER LINE OF THE BAR LOCATED <br />BETWEEN 39 INCHES AND 41 INCHES FROM THE REAR WALL. <br />EXCEPTIONS: IN TYPE A UNITS, THE VERTICAL GRAB BAR COMPONENT IS NOT <br />REQUIRED. ICC/ANSI Al 17.1 -2009 SECTION 604.5.1 <br />VERTICAL GRAB BAR NOT REQUIRED IN PRIVATE RESIDENCES. <br />TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 309.4 AND SHALL BE <br />7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET <br />MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE DISPENSER <br />SHALL BE 15 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FLOOR, <br />AND SHALL NOT BE LOCATED BEHIND THE GRAB BARS. DISPENSERS SHALL NOT BE <br />OF A TYPE THAT CONTROL DELIVERY, OR DO NOT ALLOW CONTINUOUS PAPER FLOW. <br />LAVATORIES AND SINKS - ICC/ANSI Al 17.1 -2009 SECTION 606 <br />A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305.3, POSITIONED FOR FORWARD <br />APPROACH, SHALL BE PROVIDED. KNEE AND TOE CLEARANCE COMPLYING WITH <br />SECTION 306 SHALL BE PROVIDED. THE DIP OF THE OVERFLOW SHALL NOT BE <br />CONSIDERED IN DETERMING KNEE AND TOE CLEARANCES. <br />LAVATORY OR SINK. <br />LAVATORIES AND SINKS IN TYPE "A" UNITS SHALL BE MOUNTED WITH THE RIM OR <br />COUNTER SURFACE NO HIGHER THAN 34 INCHES ABOVE THE FINISHED FLOOR <br />THE TOTAL DEPTH OF THE CLEAR SPACE BENEATH A LAVATORY SHALL BE NOT <br />LESS THAN 17 INCHES, OF WHICH TOE CLEARANCE SHALL BE NOT MORE THAN 6 <br />INCHES OF THE TOTAL DEPTH. KNEE CLEARANCE SHALL BE NOT LESS THAN 27 <br />INCHES IN HEIGHT AND 30 INCHES IN WIDTH. ICC/ANSI Al 17.1-2009 SECTION 306. <br />KNEE CLEARANCE NOT LESS THAN 27 INCHES IN HEIGHT, 30 INCHES IN WIDTH <br />AND 17 INCHES IN DEPTH SHALL BE PROVIDED UNDERNEATH SINKS. (APPLY TO <br />COMMON USE AREAS AND TYPE A UNITS ONLY, NOT TYPE B UNITS, EXCEPT WHERE <br />A PARALLEL APPROACH CANNOT BE ACCOMPLISHED.) ICC/ANSI Al 17.1 -2009 <br />SECTION 306. <br />WATER SUPPLY & DRAIN PIPES EXPOSED UNDER LAVATORIES AND SINKS SHALL BE <br />INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR <br />ABRASIVE SURFACES UNDER LAVATORIES OR SINKS. <br />FAUCET CONTROL HANDLES SHALL BE LOCATED NOT MORE THAN 25 INCHES <br />FROM THE FRONT EDGE OF THE LAVATORY, SINK OR COUNTER, AND OPERABLE <br />PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT <br />GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO <br />ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS (22.2 N) MAXIMUM. <br />MIRRORS OR SHELVES SHALL BE INSTALLED SO THAT THE BOTTOM OF THE <br />MIRROR OR THE TOP OF THE SHELF IS WITHIN 40 INCHES OF THE FLOOR. <br />KITCHENS - ICC/ANSI Al 17.1 -2009 SECTION 1003.12 <br />AN UNOBSTRUCTED FLOOR SPACE SHALL BE PROVIDED WITHIN KITCHENS OF <br />SUFFICIENT SIZE TO INSCRIBE A CIRCLE WITH A DIAMETER OF NOT LESS THAN <br />60 INCHES. DOORS IN ANY POSITION MAY ENCROACH INTO THIS SPACE BY NOT <br />MORE THAN 12 INCHES. THE CLEAR FLOOR SPACE AT FIXTURES, THE <br />ACCESSIBLE ROUTE OF TRAVEL, AND THE UNOBSTRUCTED FLOOR SPACE MAY <br />OVER LAP. AN ALTERNATE T-SHAPED SPACE IS ACCEPTABLE. SEE SHEET A0.4 <br />WITHIN TYPE "A" DWELLING UNITS, A COUNTER SURFACE, A MINIMUM OF 30 <br />INCHES WIDE BY 24 INCHES DEEP, SHALL BE PROVIDED AT A MAXIMUM HEIGHT <br />OF 34 INCHES, WITH A KNEE SPACE BENEATH AT LEAST 27 INCHES IN HEIGHT. <br />KITCHENS MUST HAVE A CLEAR. SPACE AT LEAST 30 INCHES BY 48 INCHES THAT <br />ALLOWS PARALLEL APPROACH BY A PERSON IN A WHEELCHAIR AT THE RANGE <br />OR COOK TOP AND ALL OTHER APPLIANCES. REFERIGERATOR IN TYPE "A" UNITS <br />MUST HAVE A PARALLEL APPROACH. SINKS MUST ALLOW FOR A FORWARD APPROACH. <br />CLEARANCE BETWEEN ALL OPPOSING COUNTERS, BASE CABINETS, <br />COUNTERTOPS, APPLIANCES AND WALLS SHALL BE NOT LESS THAN 40 INCHES. <br />IN "U" SHAPED KITCHENS AN UNOBSTRUCTED FLOOR SPACE OF SUFFICIENT SIZE <br />TO INSCRIBE A CIRCLE WITH A DIAMETER OF NOT LESS THAN 60 INCHES SHALL <br />BE PROVIDED. <br />ALTERNATE: T-SHAPED SPACE AS SHOWN ON SHEET A0.4 <br />(NOT APPLICABLE FOR GALLEY TYPE KITCHENS) <br />BATHROOMS MUST HAVE CLEAR FLOOR SPACE FOR ALL FIXTURES. DOORS SHALL <br />NOT SWING INTO THE CLEAR FLOOR SPACE FOR ANY FIXTURE. <br />ALL UNITS MUST COMPLY WITH THE ABOVE EXCEPT TYPE "B" DWELLING UNITS <br />WHICH MUST MEET THE FOLLOWING REQUIREMENTS <br />TYPE "B" UNITS <br />ONLY THE PRIMARY ENTRY DOOR MUST MEET THE REQUIREMENTS FOR THE <br />MANEUVERING CLEARANCES, ICC/ANSI Al 17.1-2009 SECTION 1004.5. <br />THE REQUIRED 24" DEEP X 30" WIDE WORK AREA IS NOT REQUIRED IN THE KITCHEN. <br />CABINETRY IN KITCHENS AND BATHS INSTALLED BENEATH THE SINKS AND LAVATORIES <br />MAY BE INSTALLED PROVIDED THAT SUCH CABINETRY IS NOT PERMANENT AND IS <br />EASILY REMOVABLE. PROVIDE FINISHED FLOOR UNDER SINK CABINETS. THE WALLS <br />BEHIND AND SURROUNDING THE CABINETRY ARE FINISHED. <br />SEATS FOR BATHTUBS OR SHOWERS ARE NOT REQUIRED. <br />THE CLEAR FLOOR SPACE FOR BATHTUBS OR SHOWERS MAY BE REDUCED TO <br />NOT LESS THAN 30 INCHES IN WIDTH BY 48 INCHES IN LENGTH. <br />TRANSFER SHOWERS REQUIRE 36" X 48" <br />GRAB BARS MAY BE OMITTED PROVIDED THAT ALL STRUCTURAL <br />REINFORCEMENTS FOR GRAB BAR INSTALLATION ARE PROVIDED IN THE <br />APPROPRIATE LOCATIONS IN THE ADJOINING WALLS. <br />j <br />• I <br />Ilia <br />SOUTH DAKOTA <br />CLEARANCE IN FRONT OF BATHTUBS SHALL EXTEND THE LENGTH OF THE BATHTUB <br />AND SHALL BE 30 IN (760 MM) DEPTH MINIMUM. A LAVATORY COMPLYING WITH <br />SECTION 606 SHALL BE PERMITTED AT THE FOOT END OF THE CLEARANCE. WHERE <br />A PERMANENT SEAT IS PROVIDED AT THE HEAD END OF THE BATHTUB, THE CLEARANCE <br />SHALL EXTEND A MINIMUM OF 12 IN (305 MM) BEYOND THE WALL AT THE HEAD END <br />OF THE BATHTUB. <br />A LAVATORY MAY BE LOCATED IN THE CLEAR FLOOR SPACE FOR THE TUB. <br />WHERE A SEAT IS PROVIDED AND A LAVATORY IS LOCATED IN THE CLEAR <br />FLOOR SPACE FOR THE TUB, THE LAVATORY SHALL BE LOCATED AT THE FOOT END <br />OF THE TUB. ICC/ANSI Al 17.1 , SECTION 607.2. <br />A PERMANENT SEAT AT THE HEAD END OF THE BATHTUB OR A REMOVABLE <br />IN -TUB SEAT SHALL BE PROVIDED. SEA -IS SHALL COMPLY WITH SECTION 610. <br />EXCEPTION: IN DWELLING UNITS THE REMOVABLE IN -TUB SEAT IS NOT REQUIRED. <br />ICC/ANSI Al 17.1 -2009 SECTION 1003.1 1 .2.5.1 <br />ALL REQUIRED GRAB BARS SHALL BE INSTALLED PARALLEL TO THE FLOOR, UNLESS <br />SPECIFIED OTHERWISE. LOWER GRAB BARS SHALL BE INSTALLED CENTERED 9 INCHES <br />ABOVE THE TUB TRIM. UPPER OR SINGLE GRAB BARS SHALL BE INSTALLED <br />CENTERED NOT LESS THAN 33 INCHES AND NOT MORE THAN 36 INCHES ABOVE <br />THE FLOOR OF THE CLEAR SPACE. <br />BATHTUBS WITHOUT PERMANENT SEATS: TWO HORIZONTAL GRAB BARS SHALL BE <br />PROVIDED ON THE BACK WALL, ONE COMPLYING WITH SECTION 609.4 AND THE <br />OTHER 9 INCHES ABOVE THE RIM OF THE BATHTUB. EACH GRAB BAR SHALL <br />BE 24 INCHES MINIMUM IN LENGTH, LOCATED 24 INCHES MAXIMUM FROM THE <br />HEAD END WALL AND EXTEND TO 12 INCHES MAXIMUM FROM THE CONTROL <br />END WALL. A HORIZONTAL GRAB BAR 24 INCHES MINIMUM IN LENGTH SHALL BE <br />PROVIDED ON THE CONTROL END WALL BEGINNING NEAR THE FRONT EDGE OF THE <br />BATHTUB AND EXTEND TOWARD THE INSIDE CORNER OF THE BATHTUB. A VERTICAL <br />GRAB BAR 18 INCHES MINIMUM IN LENGTH SHALL BE PROVIDED ON THE CONTROL <br />END WALL 3 INCHES MINIMUM TO 6 INCHES MAXIMUM ABOVE THE HORIZONTAL <br />GRAB BAR, AND 4 INCHES MAXIMUM INWARD FROM THE FRONT EDGE OF THE <br />BATHTUB. <br />EXCEPTION: AN L-SHAPED CONTINUOUS GRAB BAR OF EQUIVALENT DIMENSIONS <br />AND POSITIONING SHALL BE PERMITTED TO SERVE THE FUNCTION OF SEPARATE <br />VERTICAL AND HORIZONTAL GRAB BARS. ICC/ANSI Al 17.1-2009 SECTION 607.4.2.2 <br />A HORIZONTAL GRAB BAR 12 INCHES MINIMUM IN LENGTH SHALL BE PROVIDED <br />ON THE HEAD END WALL AT THE FRONT EDGE OF THE BATHTUB. <br />1N TYPE "A" UNITS CONTROLS, OTHER THAN DRAIN STOPPERS, SHALL BE PROVIDED <br />ON AN END WALL LOCATED BETWEEN THE BATHTUB RIM AND GRAB BAR, AND BETWEEN <br />BETWEEN THE OPEN SIDE OF THE BATHTUB AND THE MIDPOINT OF THE WIDTH OF THE <br />BATHTUB. CONTROLS SHALL HAVE A LEVER OR OTHER SHAPE WHICH WILL PERMIT <br />OPERATION BY WRIST OR ARM PRESSURE AND WHICH DOES NOT REQUIRE TIGHT <br />GRASPING, PINCHING OR TWISTING TO OPERATE. <br />A HAND SHOWER WITH A HOSE 59 INCHES MINIMUM IN LENGTH, THAT CAN BE <br />USED AS BOTH A FIXED SHOWER HEAD AND AS A HAND SHOWER, SHALL BE <br />PROVIDED. THE HAND SHOWER SHALL HAVE A CONTROL WITH A NONPOSITIVE <br />SHUT-OFF FEATURE. AN ADJUSTABLE -HEIGHT HAND SHOWER MOUNTED ON A <br />VERTICAL BAR SHALL BE INSTALLED SO AS TO NOT OBSTRUCT THE USE OF <br />GRAB BARS. HAND SHOWER NOT REQUIRED IN TYPE "B" UNITS <br />GRAB BARS - ICC/ANSI Al 17.1 -2009, SECTION 609 <br />GRAB BARS SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN 1-1/4 INCH <br />NOR MORE THAN 2 INCHES AND SHALL PROVIDE A CLEARANCE OF 1-1/2 <br />INCHES BETWEEN THE GRAB BAR AND THE WALL. <br />THE STRUCTURAL STRENGTH OF GRAB BARS , TUB AND SHOWER SEAIS, <br />FASTENERS AND MOUNTING DEVICES SHALL MEET THE FOLLOWING <br />SPECIFICATION: ICC/ANSI Al 17.1-2009, SECTION 609.8 AND 610.4. <br />ALLOWABLE STRESSES IN BENDING, SHEAR, AND TENSION SHALL NOT BE <br />EXCEEDED <br />FOR MATERIALS USED WHERE A VERTICAL OR HORIZONTAL FORCE OF 250 <br />LBS IS <br />APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER MOUNTING DEVICE, <br />OR <br />SUPPORTING STRUCTURE. <br />ALLOWABLE STRESSES IN BENDING, SHEAR, AND TENSION SHALL NOT BE <br />EXCEEDED <br />FOR MATERIALS USED WHERE A VERTICAL OR HORIZONTAL FORCE OF 250 <br />LBS IS <br />APPLIED AT ANY POINT ON THE SEAT, FASTENER MOUNTING DEVICE, OR <br />SUPPORTING STRUCTURE. <br />SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE <br />APPLICATION OF 250 POUNDS SHALL BE LESS THAN THE ALLOWABLE LATERAL <br />LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR THE SUPPORTING <br />STRUCTURE, WHICHEVER IS THE SMALLER ALLOWABLE LOAD. <br />TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF 250 <br />POUNDS PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF 250 POUNDS <br />SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE <br />FASTENER AND THE SUPPORTING STRUCTURE, <br />A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE <br />FREE OF ANY SHARP OR ABRASIVE ELEMENTS. EDGES SHALL BE ROUNDED. <br />GRAB BARS ARE NOT REQUIRED TO BE INSTALLED, BUT BACKING FOR GRAB <br />BARS IN ALL UNITS IS REQUIRED TO BE INSTALLED. <br />IN ALL PUBLIC AREAS SUCH AS THE COURT YARD, SOCIAL ROOM, GAME ROOM, <br />CRAFTS ROOM AND PRIVATE DINING ROOMS PROVIDE A MINIMUM OF 5% OF <br />SEATING IS ACCESSIBLE WITH 27" HIGH X 30" WIDE X 19" DEEP KNEE SPACE. <br />BENCHES MUST MEET THE REQUIREMENTS FOR SIZE, BACK SUPPORT, HEIGHT AND <br />STRUCTURAL STRENGTH. <br />ENSURE ALL EXTERIOR DOORS HAVE GRADES THAT ARE MAXIMUM 1:48 IN ALL <br />DIRECTION FOR A DEPTH OF 60" PERPENDICULAR TO THE DOOR. <br />PROVIDE A 36" ACCESSIBLE ROUTE OF TRAVEL TO ALL EXERCISE EQUIPMENT <br />ACCESS POINTS AND BETWEEN EQUIPMENT AND COLUMNS. <br />HVAC CONTROL ARE NOT LOWER THAN 15" AND AT TYPE "A" UNITS, THAT THE <br />CONTROLS DO NOT REQUIRE TWISTING OR GRIPPING. <br />OUTLETS, COUNTERTOP OUTLETS, SWITCHES AND THERMOSTATS, MEET FHA REQ. 5 <br />OUTLETS MUST BE MINIMUM 15" TO THE LOWEST OUTLET, COUNTERTOP OUTLETS 44" <br />TO THE HIGHEST OUTLETS AND SWITCHES AND THERMOSTATS MAXIMUM 48" TO THE <br />HIGHEST CONTROLS, KITCHEN CORNER OUTLET MUST BE MINIMUM 36" FROM THE <br />INSIDE CORNER OF THE WALL SURFACE IN "L" SHAPE AND "U" SHAPE KITCHENS. <br />51 UNIT THE LANDING AT FORT GARDNER AFA TMENT <br />50 RUCKER AVE, EVE ETT, WA <br />DEVELOPER <br />ACCESSIBLE AUDIBLE AND VISUAL ALARMS AND NOTIFICATION APPLIANCES <br />SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 LISTED IN SECTION <br />105.2.2, BE POWERED BY A COMMERCIAL LIGHT AND POWER SOURCE, BE <br />PERMANENTLY CONNECTED TO THE WIRING OF THE PREMISES ELECTRIC <br />SYSTEM, AND BE PERMANENTLY INSTALLED. <br />VISIBLE ALARM SIGNAL APPLIANCES SHALL BE INTEGRATED INTO THE BUILDING <br />OR FACILITY ALARM SYSTEM. WHERE SINGLE -STATION AUDIBLE ALARMS ARE <br />PROVIDED, SINGLE -STATION VISIBLE ALARMS SIGNALS SHALL BE PROVIDED. <br />VISIBLE ALARMS SHALL BE LOCATED NOT LESS THAN 80 INCHES ABOVE FLOOR <br />LEVEL, OR 6 INCHES BELOW THE CEILING, WHICHEVER IS LOWER, AND AT AN <br />INTERVAL OF NOT MORE THAN 50 FEET HORIZONTAL, IN ROOMS, CORRIDORS <br />AND HALLWAYS. <br />IN ROOMS OR SPACES EXCEEDING 100 FEET IN HORIZONTAL DIMENSION, WITH <br />NO OBSTRUCTIONS EXCEEDING 6 FEET IN HEIGHT ABOVE THE FINISH FLOOR, <br />VISIBLE ALARMS MAY BE PLACED AROUND THE PERIMETER. AT INTERVALS NOT <br />TO EXCEED 100 FEET HORIZONTALLY. <br />VISIBLE ALARMS SIGNALS SHALL COMPLY WITH THE FOLLOW CRITERIA. <br />THE LAMPS SHALL BE XENON STROBE TYPE OR EQUIVALENT. <br />THE COLOR SHALL BE CLEAR OR NOMINAL WHITE. <br />THE MAXIMUM PULSE DURATION SHALL BE TWO -TENTHS OF ONE SECOND WITH <br />A MAXIMUM DUTY CYCLE OF 40 PERCENT. THE PULSE DURATION IS DEFINED AS <br />THE TIME INTERVAL BETWEEN INITIAL AND FINAL POINT OF 10 PERCENT OF <br />MAXIMUM SIGNAL. <br />THE <br />INTENSITY SHALL BE <br />A <br />MINIMUM OF 75 <br />CANDELA. <br />THE <br />FLASH RATE SHALL <br />BE <br />A MINIMUM OF 1 <br />Hz AND A MAXIMUM OF 2 Hz. <br />VISIBLE ALARMS SHOULD BE PROVIDED IN COMMON -USE AREA AS PER W.S.B.C. <br />1 105.4.9 (SOCIAL ROOM, LIBRARY, BEAUTY SHOP, ACTIVITIES ROOM, EXERCISE <br />ROOM, OFFICES, TOILET ROOMS. <br />SIGNS - ICC/ANSI Al 17.1 -2009 SECTION 703 & WAC 51-50 1 101 .2.9 <br />SIGNS THROUGHOUT THE SITE AS REQUIRED PER IBC SECTION 1111. <br />SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF <br />THE DOOR. BASE LINE OF LOWEST AND HIGHEST TACTILE TEXT SHALL BE <br />BETWEEN 48 AND 60 INCHES ABOVE THE FINISHED FLOOR. A CLEAR FLOOR <br />AREA 18 INCHES MINIMUM BY 18 INCHES MINIMUM, CENTERED ON THE TACTILE <br />CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN <br />THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. <br />CHARACTERS AND SYMBOLS SHALL HAVE A HIGH CONTRAST WITH THEIR <br />BACKGROUND. THE CHARACTER AND BACKGROUND OF INTERIOR SIGNS SHALL <br />HAVE A NONGLARE FINISH. <br />THE UPPERCASE LETTER "I" SHALL BE USED TO DETERMINE THE ALLOWABLE <br />HEIGHT OF ALL CHARACTERS OF A FONT. THE UPPERCASE LETTER "I" OF THE <br />FONT SHALL HAVE A MINIMUM HEIGHT COMPLYING WITH TABLE 703.2.4. <br />THE UPPERCASE LETTER "0" SHALL BE USED TO DETERMINE THE ALLOWABLE <br />WIDTH OF ALL CHARACTERS OF A FONT. THE WIDTH OF THE UPPERCASE <br />LETTER "0" OF THE FONT SHALL BE 55 PERCENT MINIMUM AND 110 PERCENT <br />MAXIMUM OF THE HEIGHT OF THE UPPERCASE "I" OF THE FONT. <br />CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO THE <br />VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THE MINIMUM <br />CHARACTER HEIGHT FOR SIGNS THAT ARE SUSPENDED OR PROJECTED <br />OVERHEAD IS 3 INCHES FOR UPPER CASE LETTERS. LOWER CASE LETTERS ARE <br />PERMITTED. ANSI SEC 703 <br />CHARACTERS AND SYMBOLS ON TACTILE SIGNS SHALL BE RAISED AT LEAST 1 /32 <br />INCH. RAISED CHARACTERS AND SYMBOLS SHALL BE SIMPLE TYPE FACE <br />UPPERCASE CHARACTERS. RAISED CHARACTERS AND SYMBOLS SHALL BE <br />BETWEEN 5/8 INCH AND 2 INCHES IN HEIGHT. RAISED CHARACTERS SHALL BE <br />ACCOMPANIED BY BRAILLE. <br />BRAILLE SHALL BE BELOW THE CORRESPONDING TEXT, SEPARATED BY AT LEAST <br />3/8 INCH FROM ANY OTHER TACTILE CHARACTERS OR RAISED BORDERS AND <br />DECORATIVE ELEMENTS. BRAILLE SHALL BE 48 INCHES MINIMUM AND 60 INCHES <br />MAXIMUM ABOVE THE FLOOR, MEASURED TO THE BASELINE OF THE BRAILLE CELLS. <br />WHERE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS REQUIRED, IT SHALL BE <br />PORPORTIONED COMPLYING WITH ICC/ANSI 1 17.1 -2009 FIGURE 703.6.3.1 <br />ALL INTERIOR AND EXTERIOR SIGNS DEPICTING THE INTERNATIONAL SYMBOL OF <br />ACCESSIBILITY SHALL BE WHITE ON A BLUE BACKGROUND. <br />FOR TYPE "A" AND TYPE "B" UNITS <br />PARKING ICC/ANSI Al17.A-2009 SECTION 502 <br />SEE PARKING PAVING PLAN FOR REQUIRED ACCESSIBLE PARKING SPACES. <br />ACCESSIBLE PARKING SPACES SHALL BE LOCATED ON THE SHORTEST <br />POSSIBLE ACCESSIBLE ROUTE OF TRAVEL TO AN ACCESSIBLE BUILDING <br />ENTRANCE. RANCE. IN FACILITIES WITH MULTIPLE ACCESSIBLE BUILDING ENTRANCES <br />WITH ADJACENT PARKING, ACCESSIBLE PARKING SPACES SHALL BE DISPERSED <br />AND LOCATED NEAR THE ACCESSIBLE ENTRANCES. WHEREVER PRACTICAL, <br />THE ACCESSIBLE ROUTE OF TRAVEL SHALL NOT CROSS LANES OF VEHICULAR <br />TRAFFIC. WHERE CROSSING TRAFFIC LANES IS NECESSARY, THE ROUTE OF <br />TRAVEL SHALL BE DESIGNATED AND MARKED AS A CROSSWALK. <br />PARKING SPACES SHALL BE NOT LESS THAN 96 INCHES IN WIDTH AND SHALL <br />HAVE AN ADJACENT ACCESS AISLE NOT LESS THAN 60 INCHES IN WIDTH. VAN <br />ACCESSIBLE PARKING SPACES SHALL BE 132 INCHES MINIMUM IN WIDTH. <br />EXCEPTION: VAN PARKING SPACES SHALL BE PERMITTED TO BE 96 INCHES <br />MINIMUM IN WIDTH WHERE THE ADJACENT ACCESS AISLE IS 96 INCHES <br />MINIMUM IN WIDTH. <br />WHERE TWO ADJACENT SPACES ARE PROVIDED, THE ACCESS AISLE MAY BE <br />SHARED BETWEEN TWO SPACES. BOUNDARIES OF ACCESS AISLES SHALL BE <br />MARKED SO THAT THE AISLES WILL NOT BE USED AS PARKING SPACE. <br />WHERE ACCESSIBLE PARKING SPACES ARE REQUIRED FOR VANS, THE <br />VERTICAL CLEARANCE SHALL BE NOT LESS THAN 98 INCHES AT THE PARKING <br />SPACE AND ALONG AT LEAST ONE VEHICLE ACCESS ROUTE TO SUCH SPACES <br />FROM SITE ENTRANCES AND EXITS. <br />ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL BE LOCATED ON A <br />SURFACE WITH A SLOPE NOT TO EXCEED 1 VERTICAL IN 48 HORIZONTAL. <br />PARKING SPACES AND ACCESS AISLES SHALL BE FIRM, STABLE, SMOOTH AND <br />SLIP RESISTANT. <br />EVERY ACCESSIBLE PARKING SPACE SHALL BE IDENTIFIED BY A SIGN, CENTERED <br />WITH BOTTOM NOT LESS THAN 60 INCHES ABOVE THE PARKING SURFACE, AT THE <br />HEAD OF THE PARKING SPACE. THE SIGN SHALL INCLUDE THE INTERNATIONAL <br />SYMBOL OF ACCESS AND THE PHRASE "STATE DISABLED PARKING PERMIT <br />REQUIRED". <br />VAN ACCESSIBLE PARKING SPACES SHALL HAVE AN ADDITIONAL SIGN MOUNTED <br />BELOW THE INTERNATIONAL SYMBOL OF ACCESS IDENTIFYING THE SPACE AS <br />"VAN ACCESSIBLE" <br />INTERNATIONAL SYMBOL <br />OUTLETS TO BE NOT LOWER THAN 15" HIGH MEASURED FROM THE CENTERLINE OF THE <br />LOWEST OUTLET TO THE FINISH FLOOR. <br />KITCHEN & BATH OUTLETS NEED TO BE A MAXIMUM 44" HIGH MEASURED FROM FINISHED FLOOR <br />TO THE HIGHEST OUTLET <br />KITCHEN OUTLETS IN CORNERS SHALL BE LOCATED AT LEAST 36" FROM <br />CABINET/COUNTER CORNERS. <br />ALL THERMOSTATS SHALL BE A MAXIMUM OF 48" HIGH MEASURED TO THE HIGHEST CONTROL. <br />1" <br />12" <br />A0,3 <br />* BARRIER -FREE, HANDICAP ACCESSIBILITY PER IBC CHAPTERS 10 & 1 1 ; IBC APPENDIX E, <br />SECTIONS E101 THRU E107; ICC/ANSI Al 17.1-2009; WASHINGTON STATE AMENDMENTS <br />PER WAC 51 -50. <br />C�'i%:!,�;`� �C(?RG�I� & .a;;`;fit_11fC?`_;, L1:(; <br />PHONE 425-353-2888 <br />EMAIL infacmaarchecom <br />