Laserfiche WebLink
111 011 ill I I li� 1 <br />Merrill Creek F <br />J <br />m <br />CD <br />�� <br />0 <br />u) <br />1 <br />CD <br />Aa <br />I <br />e,A <br />5` <br />PROJECT LOCATION <br />Madison St <br />❑© <br />I <br />PROJECT DIRECTORY <br />CLIENT <br />BUILDING DEPARTMENT <br />REPRESENTATIVES: <br />CITY OF EVERETT Community Development <br />NAME - RYAN COXEY, AMAZON Pre -Construction Manager <br />3200 CEDAR ST., Suite 250, <br />PHONE - 813.406.3798 <br />EVERETT WA 98201 <br />EMAIL - ryancoxe0amazon.com <br />PROPERTY OWNER - LANDLORD REP <br />ELECTRICAL ENGINEER <br />REPRESENTATIVE: <br />VAA, LLC <br />NAME - RYAN COXEY, AMAZON Pre -Construction Manager <br />2300 BERKSHIRE LN N #200 <br />PHONE - 813.406.3798 <br />PLYMOUTH, MN 55441 <br />EMAIL - ryancoxe®amazon.com <br />REPRESENTATIVE: <br />NAME - DEREK R. SACHS <br />PHONE - 763.577.9157 <br />ARCHITECT <br />GEOTECHNICAL <br />MG2 <br />KLEINFELDER <br />1101 2ND AVE #100 <br />14710 NE 87th STREET, SUITE 100 <br />SEATTLE, WA 98101 <br />REDMOND, WA 98052 <br />REPRESENTATIVE: <br />REPRESENTATIVE: <br />NAME - ANGELA BALMER <br />NAME - MARCUS B. BYERS <br />PHONE - 206.962.6500 <br />PHONE - 425.533.0855 <br />EMAIL - ANGELA.BALMER®MG2.COM <br />CIVIL ENGINEER <br />CEC, INC <br />4350 NORTHERN PIKE #141 <br />MONROEVILLE, PA 15146 <br />REPRESENTATIVE: <br />NAME - JOSHUA A.MAGARGEE <br />PHONE - 724.387.6338 <br />STRUCTURAL ENGINEER <br />VAA, LLC <br />2300 BERKSHIRE LN N #200 <br />PLYMOUTH, MN 55441 <br />REPRESENTATIVE: <br />NAME - MARK D. MIELKE <br />PHONE - 763.577.9120 <br />MECHANICAL ENGINEER <br />VAA, LLC <br />2300 BERKSHIRE LN N #200 <br />PLYMOUTH, MN 55441 <br />REPRESENTATIVE: <br />NAME - BARRETT M. WINRICK <br />PHONE - 763,587.7329 <br />1 <br />DRAWING INDEX <br />SHEET <br />SHEET <br />REVISION <br />REVISION <br />NUMBER <br />SHEET TITLE <br />ISSUE <br />NUMBER <br />ISSUE <br />DATE <br />DATE <br />GENERAL <br />G0.01 <br />TITLE SHEET <br />05/05/21 <br />G0.02 <br />PROJECT GEN NOTES, SYMBOLS & ABBREV. <br />05/05/21 <br />G1.10 <br />CODE ANALYSIS <br />05/05/21 <br />ARCHITECTURAL SITE <br />SD1.21 <br />BUILDING SIGNAGE AND GRAPHIC DETAILS <br />05/05/21 <br />ARCHITECTURAL <br />A1.01 <br />DEMO FLOOR PLAN <br />05/05/21 <br />A1.10 <br />OVERALL FLOOR PLAN <br />05/05/21 <br />A6.10 <br />DOOR SCHEDULES AND TYPE <br />05/05/21 <br />CIVIL <br />C0.00 <br />COVER SHEET <br />05/05/21 <br />C1.00 <br />OVERALL EXISTING CONDITIONS AND <br />REMOVALS PLAN <br />05/05/21 <br />C1.01 <br />OVERALL EXISTING CONDITIONS AND <br />REMOVALS PLAN <br />05/05/21 <br />C2.00 <br />OVERALL SITE PLAN <br />05/05/21 <br />C2.01 <br />ENLARGED SITE PLAN/ SIGNAGE AND STRIPING <br />P <br />05/05/21 <br />C2.02 <br />VEHICLE TURNING MOVEMENTS PLAN <br />05/05/21 <br />C8.00 <br />DETAILS SHEET <br />05/05/21 <br />PROJECT DESCRIPTION <br />REQUIRED VENDORS - NO SUBSTITUTIONS <br />EXISTING CONCRETE TILT -UP SINGLE STORY WAREHOUSE BUILDING (S-1 OCC.) TO BE <br />TRANSFORMED INTO (S-2 STORAGE) FOR INTERIOR VAN FLEET PARKING/STORAGE. <br />SEE CRITERIA SPECIFICATIONS. <br />EXISTING OFFICE AREA(B OCC) AND BREAK ROOM (A-3 OCC) TO REMAIN, BUT NOT IN USE. <br />THE RESTROOMS WILL REMAIN OPEN. <br />PROJECT/CODE INFORMATION <br />DEVIATIONS NARRATIVE <br />SITE AREA: +/- 5.0 AC. (217,800 S.F.) <br />DESIGN STANDARDS INFORMATION <br />BUILDING AREA: 85,045 S.F. <br />REFER TO CRITERIA AND WWDS APPENDIX LISTING ALL RELEVANT DESIGN STANDARDS AND CONTROL DOCUMENTS FOR <br />OCCUPANCY TYPE: A-3, B, S-2 <br />THIS FACILITY <br />CONSTRUCTION TYPE: III-B, FULLY SPRINKLERED (TO BE VERIFIED FOR EXISTING BUILDING) <br />BUILDING CLEAR HEIGHT: APPROX. 24'-30" (V.I.F.) TO ANY OBSTRUCTION INCLUDING SPRINKLERS, DUCTS, LIGHTS, ETC. <br />APPLICABLE CODES: <br />DEFERRED SUBMITTALS <br />2018 INTERNATIONAL BUILDING CODE (IBC) <br />2018 INTERNATIONAL EXISTING BUILDING CODE IEBC <br />2018 INTERNATIONAL FIRE CODE (IFC) <br />2018 INTERNATIONAL MECHANICAL CODE (IMC) <br />• FIRE PROTECTION(DESIGN/BUILD) <br />2018 WASHINGTON STATE ENERGY CODE COMMERCIAL(WSEC) <br />• FIRE ALARM (DESIGN/BUILD) <br />2018 UNIFORM PLUMBING CODE <br />2020 NATIONAL ELECTRICAL CODE (NEC) <br />EVERETT MUNICIPAL CODE, TITLE 19 ZONING <br />ICC/ANSI A117.1-2009 - ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES <br />DESIGN STANDARDS INFORMATION <br />DRAWING SHEET NAMING <br />REFER TO CRITERIA AND WWD'S APPENDIX LISTING ALL RELEVANT DESIGN STANDARDS AND CONTROL DOCUMENTS <br />FOR THIS FACILITY. <br />ALL DRAWINGS ARE IDENTIFIED BY A PREFIX AS FOLLOWS: <br />A. CATEGORY LETTER REFERRING TO THE DISCIPLINE OR MAJOR DIVISION. <br />G. GENERAL SHEETS <br />DESIGN STANDARDS <br />C. CIVIL <br />A. ARCHITECTURE <br />APPLICABLE DESIGN STANDARDS INCORPORATED IN THIS TEMPLATE ARE LISTED BELOW <br />S STRUCTURAL <br />..� �, . . ��_ . <br />.411 014, <br />yb x r <br />k h' •r?""' C 4 'F+h h 'gyp, '.. A4 <br />Amazon AMZL Global Design Guidelines Security <br />NA Yard Design Guidelines <br />t 4 <br />2 <br />P. <br />6/26/2018 <br />12/7/2020 <br />FC IT 2021 A.E.M. Infrastructure Global Standards <br />9.1 <br />12/31/2020 <br />NA EHS Walking Working Surfaces Procedure <br />4.1 <br />3/30/2018 <br />WWD Q3 2020 Amazon Signage Standard <br />1 <br />Q3 2020 <br />WWDS NA Associate Parking <br />WWDS NA Circulation Areas Outside (Pedestrians) <br />2 <br />3/26/2020 <br />2 <br />3/26/2020 <br />WWDS NA Demarcation Room 2 <br />WWDS NA Locker Room 2 <br />3/26/2020 <br />3/26/2020 <br />WWDS NA Mother's Room <br />3 <br />6/3/2020 <br />WWDS NA Multi -Faith Room <br />1 <br />5/29/2020 <br />WWDS NA Remote Breakroom <br />2 <br />3/26/2020 <br />WWDS NA Restrooms <br />2 <br />3/26/2020 <br />WWDS NA Security Zoning - Rooms/Areas <br />1.1 <br />4/14/2020 <br />WWDS NA Site Signage <br />WWDS NA Traffic & Circulation Principles <br />2 <br />2 <br />3/26/2020 <br />3/26/2020 <br />P. <br />PLUMBING <br />M. <br />MECHANICAL <br />E. <br />ELECTRICAL <br />FP. <br />FIRE PROTECTION <br />FA. <br />FIRE ALARM <br />B. SUB -CATEGORY NUMBER REFERRING TO TYPE OF DRAWING OR GROUPING. <br />0. <br />GENERAL <br />1. <br />PLANS <br />2. <br />EXTERIOR ELEVATIONS <br />3. <br />SECTIONS <br />4. <br />ENLARGED PLANS / INTERIOR ELEVATIONS / ENLARGED CEILING PLANS <br />5. <br />DETAILS <br />6. <br />SCHEDULES <br />7. <br />STAIR AND ELEVATOR PLANS, SECTIONS, AND DETAILS <br />8. <br />CANOPY PLANS, SECTIONS, AND DETAILS <br />C. SOME SHEETS <br />INCLUDE A SUFFIX. THIS SUFFIX DENOTES: <br />M = MEDIUM <br />L = LARGE <br />XL = EXTRA LARGE <br />SHEET <br />REVISION <br />SHEET <br />REVISION <br />SHEET TITLE <br />ISSUE <br />ISSUE <br />NUMBER <br />NUMBER <br />DATE <br />DATE <br />MECHANICAL <br />M0.00 <br />MECHANICAL TITLE SHEET <br />05/05/21 <br />M0.10 <br />ONTROL DEVICE LIST & SEQUENCES <br />05/05/21 <br />M1.00 <br />VAC VENTILATION FLOW DIAGRAM <br />05/05/21 <br />M1.10 <br />f IRST FLOOR HVAC PLAN <br />05/05/21 <br />M8.00 <br />ECHANICAL SPECIFICATIONS <br />05/05/21 <br />ELECTRICAL <br />E0.00 <br />SYMBOLS, LEGEND, & ABBREV. - ELECTRICAL <br />05/05/21 <br />E1.11 <br />LOOR PLAN -DEMO <br />05/05/21 <br />Permit #: <br />E8.01 <br />LECTRICAL SPECIFICATIONS <br />05/05/21 <br />Site Address: <br />Owner: <br />E8.02 <br />ELECTRICAL SPECIFICATIONS <br />05/05/21 <br />Tenant: <br />E8.03 <br />ELECTRICAL SPECIFICATIONS <br />05/05/21 <br />App. Date: <br />Proposed USE <br />E8.04 <br />LECTRICAL SPECIFICATIONS <br />05/05/21 <br />Description: <br />THESE DOCUMENTS HAVE NOT BEEN <br />APPROVED FOR THE ISSUANCE OF <br />PUBLIC WORDS, MECHANICAL, FIRE <br />SUPPRESSION, ELECTRICAL OR <br />PLUMBING PERMITS, <br />Additional Permits Are Required <br />For This Project To Include: <br />Plumbing Sprinkler <br />Mechanical Pg Fire Alarm <br />] Electrical <br />EVERETT FIRE DEPT. REVIEW <br />APPROVED <br />APPROVED WITH CHANGES NOTED <br />E3 REVISE AND RESi/gMrr <br />E3 REJECTED; <br />❑ SEE ATTACHED CHECKLIST <br />IHANDOUT <br />The issuance of a permit shall not <br />be construed as authority to violate, <br />cancel or set aside an <br />the Everett Fire C y Provision of <br />or other <br />aPPlicable regulations Or flaws. The <br />issuance of a permit based on <br />construction documents and other <br />data shall not prevent the Fire Code <br />Offical from requiring the correction <br />of errors. <br />kC" I Off' EVERETT <br />REVIEWED FOR PERMIT" <br />Reviewed 4- <br />Office Set <br />© MG2. All rights resented. No part of this document may be <br />reproduced in any form or by any means without permission in. <br />writing from MG2. <br />DSE4_E1 <br />B2107-036 <br />6611 ASSOCIATED BLVD B, STE 100 <br />LIT INDUSTRIAL LIMITED PARTNERSHIP <br />AMAZON <br />7/13/2021 <br />COMMERCIAL ALTERATIONS <br />TI-TAKE OVER EXTG PODS SPACE AS <br />INDOOR PARKING -AMAZON <br />Date: 4 7//Y1 v <br />Job Site Set Fire/Planning Set <br />Z <br />W <br />2 <br />W <br />0 <br />0 <br />Z <br />Z <br />Q <br />W lb <br />r <br />W W <br />I > � <br />V <br />W - <br />W <br />m M <br />C) <br />-0 N <br />�- o0 <br />Z E0) <br />s <br />0 UJ o <br />cn 5 <br />IN cn <br />< W < <br />a� <br />r Q) <br />< W ('0 > <br />co W <br />m ii�l <br />DESCRIPTION L1 �I DATE <br />ISSUE FOR PERMIT 05.05,2021 <br />MATTHEW L. GOELZER, ARCHITECT <br />1006 REGISTERED <br />AR T <br />MATTHEW L. GOELZ R <br />STATE OF WASHINGT N 88 <br />i <br />© MG2, Inc. All rights reserved. No part of this document may <br />be reproduced in any form or by any means without permission <br />in writing from MG2, Inc. <br />PROJECT STATUS <br />Permit Set <br />JOB NUMBER <br />21-5635-01 <br />DRAWN BY CHECKED BY <br />SAC AB <br />SHEET TITLE <br />TITLE SHEET <br />SHEET NUMBER <br />0.01 <br />