C:) <br />N <br />0 <br />N <br />>+ <br />Co <br />(1) <br />tL <br />N <br />7F <br />CO <br />O <br />J <br />d <br />0 <br />v- <br />n <br />t <br />MDF ROOM: <br />CONTRACTOR TO INSTALL FIRE <br />EXTINGUISHER WITH WALL CLAMP STYE BRACKET <br />` <br />AND SIGN MULTIPURPOSE DRY CHEMICAL TYPE <br />WITH'UL'-RATING='2A-10B-C' HALOTRON'S <br />155 LB. WITH 546 BRACKET (OR AS <br />w <br />REQUIRED BY LOCAL CODE). <br />0 <br />z <br />Q <br />_ <br />WAREHOUSE: <br />w <br />CONTRACTOR TO INSTALL FIRE <br />= <br />r� <br />EXTINGUISHER WITH WALL BRACKET AND <br />SIGN MULTI -PURPOSE DRY -CHEMICAL TYPE <br />WITH 'UL'-RATING = AA-80B-C' LARSEN'S MP10 <br />WITH 546 BRACKET (OR AS REQUIRED BY <br />X <br />W <br />LOCAL CODE). <br />W <br />0 <br />PROVIDE AT LOCATIONS AS SPECIFIED BY <br />LOCAL FIRE MARSHAL AND/OR BUILDING <br />DEPARTMENT OFFICIAL. <br />NOTE: INSTALL PER ANSI A117A 308 AND 309. <br />r- LINE OF 2 1/2" SEMI -RECESSED _N A <br />ALUMINUM FIRE EXTINGUISHER <br />CABINET LARSEN'S <br />ARCHITECTURAL SERIES, <br />VERTICAL DUO. MODEL 2409-6R <br />1 WITH CLEAR ACRYLIC GLAZING <br />WITH WHITE BAKED ENAMEL. <br />WAREHOUSE <br />S-2 <br />+/- 803273 SF <br />200 <br />402 OCC. <br />PARKING GARAGE <br />SPACE REQUIRES <br />MIN (2) EXITS <br />TOTAL 13 <br />(13) 33" DOORS (0) 68" <br />DOORS PROVIDED <br />® CONTRACTOR TO INSTALL FIRE <br />Q EXTINGUISHER WITH SEMI -PURPOSE <br />= DRY -CHEMICAL TYPE WITH 'UL'- <br />w RATING='4A-80B-C' LARSEN'S MP10 <br />_ (OR AS REQUIRED BY LOCAL CODE). <br />m <br />D <br />C� <br />Z <br />X 4" MAC <br />w <br />w PROVIDE LOCATIONS AS SPECIFIED <br />U BY LOCAL FIRE MARSHAL AND/OR <br />O BUILDING DEPARTMENT OFFICIAL. <br />FIRE EXTINGUISHER MOUNTING DETAIL <br />SCALE: 3/4"=V-0" <br />•� •'I'll• <br />CONSTRUCTION TYPE: 11113, FULLY SPRINKLERED (SECTION 602.2) <br />BUILDING AREA: <br />UNLIMITED (SECTION 507) <br />BUILDING HEIGHT: <br />40' - 55' ALLOWED (SECTION 504.3) <br />OCCUPANCY: <br />S-1, UNSEPARATED INCIDENTAL USE (SECTION 509) SEE TITLE SHEET FOR <br />PROJECT DESCRIPTION <br />FULLY SPRINKLERED (SECTION 903) <br />LENGTH OF TRAVEL: <br />S-1 400' MAX. SECTION 1017.2.2 <br />B 300' MAX. (ACCESSORY USE) <br />A-3 250' MAX. (ACCESSORY USE) <br />MAX COMMON PATH OF TRAVEL (SECTION 1006.2.1) <br />S-1 100' MAX <br />B 100' MAX <br />A-3 75' MAX <br />TOTAL BUILDING AREA <br />85,045 S.F. <br />USE GROUPS: <br />PRIMARY <br />S-2 80,273 S.F. <br />ACCESSORY: <br />B 2,804 S.F. <br />A-3 1,968 S.F. <br />TOTAL ACCESSORY USE: <br />4,772 S.F. <br />TOTAL BUILDING AREA <br />85,045 S.F. / 4,772 S.F. = 18% (10% MAX PER 509) <br />TOTAL OCCUPANT LOAD <br />556 OCCUPANTS <br />TOTAL CAPACITY OF EXITS <br />553 OCCUPANTS <br />EGRESS COMPONENTS REQUIRED: (SECTION 1005.3.2) <br />0. 15" PER OCC. X 553 OCCUPANTS = 83" OF EGRESS REQUIRED <br />EGRESS COMPONENTS PROVIDED: <br />14 EGRESS DOORS AT 32" = 448" OF EGRESS PROVIDED (2,986 OCC. CAPACITY) <br />TOTAL NUMBER OF EXITS REQUIRED: 3 <br />TOTAL NUMBER OF EXITS PROVIDED: 14 <br />FIRE PROTECTION SYSTEM (SECTION 903.2) <br />FIRE SUPPRESSION SYSTEM <br />YES - APPROVED FIRE SUPPRESSION SYSTEM PER SECTION 903.2 <br />ALARMS <br />YES - APPROVED FIRE ALARM SYSTEM PER SECTION 907.2/NFPA 72 <br />AUTOMATIC FIRE DETECTION SYSTEM <br />YES - APPROVED FIRE DECTECTION SYSTEM PER SECTION 907.2/NFPA 72 <br />SMOKE CONTROL SYSTEM <br />N/A <br />SUPERVISION <br />YES, BY APPROVED SUPERVISING AGENCY (SECTION 901.6) <br />FIRE ALARM & FIRE PROTECTION NOTES: <br />1. FIRE SUPPRESSION SYSTEM - REFER TO FIRE PROTECTION DRAWINGS <br />2. FIRE ALARM SYSTEM - REFER TO FIRE ALARM DRAWINGS <br />3. COORDINATE BUILDING KEYING AND KNOX BOX LOCATION(S) WITH TENANT <br />AND AHJ/FIRE OFFICIAL. <br />4. MANUAL PULL STATION PROVIDED AT MAIN ENTRY/EXIT <br />5. FIRE EXTINGUISHERS -PORTABLE FIRE EXTINGUISHERS ARE PROVIDED AS <br />REQUIRED BY 906.1. REFER TO PLAN BELOW FOR GENERAL LAYOUT FOR <br />REFERENCE. REFER TO FIRE PROTECTION DRAWINGS FOR FE SIZE, TYPE <br />AND LOCATION. <br />PARKING- <br />c:nMMC)N PATH n, r1 nn" Al I nwFni <br />xaggdnumzma�= <br />SCALE: 1 "=30'-0" <br />+/- 1,968 SF <br />15 <br />132 OCC. <br />BUSINESS <br />g <br />+/- 27804 SF <br />150 <br />190 <br />SINESS - EXISTING TO REMAIN(NO <br />NGER IN USE) <br />COMMON PATH 0' [300' ALLOWED] <br />MAX EXIT TRAVEL +/- 97' [150' ALLOWED] <br />LEGEND <br />® INTERIOR PARTITION, <br />A-3 OCCUPANCY <br />B OCCUPANCY <br />S-2 OCCUPANCY <br />ROOM NAME/AREA NAME <br />OCCUPANCY TYPE <br />OFF <br />NUMBER OF ROOM OCCUPANTS <br />B # <br />1000 100- <br />MAXIMUM FLOOR AREA <br />ALLOWANCE (OSSC TABLE 1004.1.2) <br />ROOM SQUARE FOOTAGE GROSS UNO <br />EXIT - <br />EXIT IDENTIFIER <br />NUMBER OF EGRESSING OCCUPANTS <br /># <br />EGRESS WIDTH PROVIDED <br />X.XX" <br />EGRESS WIDTH PROVIDED <br />X.xx'r <br />SECTION 1014 COMMON PATH OF EGRESS TRAVEL TABLE 1014.3 <br />OCCUPANCY GROUP B W/ SPRINKLER SYSTEM = 100 FEET MAXIMUM <br />OCCUPANCY GROUP A W/ SPRINKLER SYSTEM = 75 FEET MAXIMUM <br />OCCUPANCY GROUP S-2 W/ SPRINKLER SYSTEM = 100 FEET MAXIMUM <br />SECTION 1016 EXIT ACCESS TRAVEL DISTANCE TABLE 1016.2 <br />OCCUPANCY GROUP B W/ SPRINKLER SYSTEM = 300 FEET MAXIMUM <br />OCCUPANCY GROUP A W/ SPRINKLER SYSTEM = 250 FEET MAXIMUM <br />OCCUPANCY GROUP S-1 W/ SPRINKLER SYSTEM = 400 FEET MAXIMUM <br />EXIT <br />PRIMARY EXIT - ALL EXITS DISCHARGE AT GRADE OR HAVE DIRECT ACCESS <br />TO GRADE <br />EXIT SIGN - SEE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION AND <br />ADDITIONAL SIGNS <br />OCCUPANCY LOAD SIGN. CONFIRM <br />LOCATION, OCCUPANCY AND <br />NUMBER WITH AHJ <br />FIRE EXTINGUISHER LOCATION <br />® PORTABLE FIRE EXTINGUISHER REQUIREMENTS SHALL BE DETERMINED BY <br />FIRE DEPARTMENT FIELD INSPECTOR IN ACCORDANCE W/ FIRE CODE <br />❑ MANUAL PULL STATION, SEE FIRE ALARM DRAWINGS <br />CODE - ENERGY CODE BASIS ON DESIGN <br />ACCESSIBILITY <br />ENERGY CODE BASIS OF DESIGN <br />EGRESS LIFE AND SAFETY GENERAL NOTES <br />ICC A117.1-2009 - ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES <br />LOCATION: EVERETT, WASHINGTON <br />EXIT DOORS <br />PLUMBING FIXTURE REQUIREMENTS <br />ROOF EXISTING, TO REMAIN <br />ARCHITECT OF RECORD TO CONFIRM REQUIREMENTS WITH LOCAL JURISDICTION <br />NOTE: TEMPLATE IS BASED ON ANSI A117.1 (2009 EDITION). ANSI A117.1 (2017 EDITION) HAS <br />PERIMETER SLAB EDGE INSULATION NONE* <br />OPAQUE WALL EXISTING, TO REMAIN <br />1: EXIT DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT SPECIAL KNOWLEDGE, <br />BEEN PUBLISHED. NATION-WIDE SCHEDULE FOR ADOPTION HAS NOT BEEN DEFINED YET AND <br />EXISTING, TO REMAIN <br />EFFORT OR THE USE OF A SPECIAL KEY OR LATCH.GLAZING <br />OCCUPANCY <br />WATER CLOSETS / URINALS <br />LAVATORIES <br />DRINKING FOUNTAIN <br />OTHER <br />THEREFORE IS NOT INCORPORATED INTO THESE TEMPLATES. <br />SOLID DOOR EXISTING, TO REMAIN <br />2. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING AN OCCUPANT LOAD <br />GLAZED DOOR EXISTING, TO REMAIN <br />OF 50 OR MORE. <br />USE <br />LOAD <br />RATIO <br />MALE <br />(50°l0) <br />FEMALE <br />(50%) <br />SINGLE <br />OCCUPANCY <br />RATIO <br />MALE <br />(50%} <br />FEMALE <br />(50%} <br />SINGLE <br />OCCUPANCY <br />RATIO <br />REFER TO SHEET AO.01 <br />NO UPDATE REQUIRED PER NEW PROPOSED USE NEW USE IS AN UNCONDITIONED SPACE) <br />( <br />3. UNLATCHING FORCE OF PANIC HARDWARE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN <br />THE DIRECTION OF TRAVEL. <br />1 PER 25 <br />1 PER 40 <br />BUSINESS <br />19 <br />FIRST 50; <br />(10) <br />(10) <br />FIRST 80; <br />(10) <br />(10) <br />4. CORRIDORS SHALL BE MAINTAINED WITH A MINIMUM CLEAR WIDTH OF 44" AND T-6" MINIMUM <br />(B) <br />THEN 1 PER 50 <br />0.4 REQ <br />0.4 REQ <br />OCCUPANT <br />THEN 1 PER 80 <br />.25 REQ <br />.25 REQ <br />OCCUPANT <br />1 FOR ANY <br />1 SERVICE <br />HEIGHT, OR AS REQUIRED BY AHJ. <br />EXCEEDING 50 <br />EXCEEDING 80 <br />OCCUPANCY <br />SINK <br />INTERIOR WALL AL L AND CEILING FINISHES <br />LOADS OF <br />15 OR LESS <br />LOADS OF <br />15 OR LESS <br />EXCEEDING 30 FOR <br />5. EXIT DOORS SHALL BE A MINIMUM OF 32" CLEAR WIDTH & MAXIMUM 48" WIDE LEAF. MINIMUM 6'-8" <br />PARKING <br />402 <br />1 PER 100 <br />(201) <br />(201) <br />CAN BE <br />(201) <br />(201) <br />CAN BE <br />THE FIRST 150 <br />DOOR HEIGHT. <br />(S) <br />2.01 REQ <br />2.01 REQ <br />SERVED <br />1 PER 100 <br />2.01 REQ <br />2.01 REQ <br />SERVED <br />OCCUPANTS; 1 <br />SECTION 803.1.1 IBC 2018 <br />WITH ONE <br />WITH ONE <br />ADDITIONAL FOR <br />Interior Wall and Ceiling Finish Materials <br />6. DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED CORRIDOR EXIT WIDTH BY MORE <br />THAN HALF. <br />1 PER 125 <br />RESTROOM <br />RESTROOM <br />EACH 500 <br />ASSEMBLY <br />(MALE) <br />(66) <br />(66) <br />(66) <br />(66) <br />OCCUPANTS <br />Class A: Flame spread index 0-25; smoke -developed index 0-450. <br />(A-3) <br />132 <br />1 PER 65 <br />0.528 REQ <br />1.02 REQ <br />1 PER 200 <br />0.33 REQ <br />0.33 REQ <br />Class B: Flame spread index 26-75; smoke -developed index 0-450. <br />7. EXTERIOR LANDINGS AT ALL EXIT DOORS SHALL BE LEVEL WITH A SLOPE OF 2% MAX. <br />(FEMALE) <br />Class C: Flame spread index 76-200; smoke -developed index 0-450. <br />TABLE 803.11 IBC 2018 SECTION 804.4.1 <br />EXIT SIGNAGE <br />1: MAIN EXIT DOORS WITHOUT PANIC HARDWARE SHALL HAVE A SIGN WITH LETTERS ON A <br />SUBTOTALS 553 <br />2.94 <br />3.43 <br />2.59 <br />2.59 <br />CONTRASTING BACKGROUND STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS <br />TOTAL REQUIRED <br />3 <br />4 <br />3 <br />3 <br />2 <br />1 <br />INTERIOR FLOOR FINISH <br />INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY <br />OCCUPIED" VERIFY WITH JURISDICTION PRECISE WORDING. <br />TOTAL PROVIDED <br />7 <br />7 <br />-- <br />4 <br />4 <br />-- <br />2 <br />1 <br />.REQUIREMENTS <br />2. TACTILE EXIT SIGNAGE SHALL BE REQUIRED. REFER TO SIGNAGE DRAWINGS FOR DETAILS AND <br />SPECIFICATIONS: <br />1. DRINKING FOUNTAIN SHALL NOT BE REQUIRED TO BE LOCATED IN INDIVIDUAL TENANT SPACES PROVIDED THAT PUBLIC DRINKING FOUNTAINS <br />Interior exit Corridors and enclosure <br />ARE LOCATED WITHIN 500 FEET FROM MOST REMOTE LOCATION WITHIN IN TENANT SPACE AND NOT MORE THAN ONE STORY ABOVE OR BELOW THE <br />stairways andramps for exit access stairways CLASS TEST Rooms and enclosed <br />. <br />A. EACH GRADE -LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A TACTILE SIGN WITH <br />TENANT SPACE. <br />and exit passageways and ramps spaces <br />THE WORD "EXIT". <br />B. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE -LEVEL EXTERIOR EXIT BY MEANS <br />2. WHERE DRINKING FOUNTAIN ARE REQUIRED, NOT FEWER THAN TWO DRINKING FOUNTAIN SHALL BE PROVIDED. <br />A-3 B B C 11 DOC FF-1 <br />OF A STAIRWAY OR RAMP SHALL BE IDENTIFIED BY A TACTILE SIGN WITH THE FOLLOWING <br />WORDS, "EXIT STAIR DOWN", "EXIT RAMP DOWN", EXIT STAIR UP", OR "EXIT RAMP UP". <br />3. WATER DISPENSERS SHALL BE PERMITTED TO SUBSTITUTE MAXIMUM 50% OF THE DRINKING FOUNTAINS. <br />B B C C II DOC FF-2 <br />C. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE -LEVEL EXTERIOR EXIT BY MEANS <br />S C C C II DOC FF-3 <br />OF AN EXIT ENCLOSURE OR AN EXIT PASSAGEWAY SHALL BE IDENTIFIED BY A TACTILE <br />EXIT SIGN WITH THE WORDS, "EXIT ROUTE". <br />D. EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM, OR AREA TO A CORRIDOR OR <br />NOTE: <br />ROOMS OR SPACES THROUGH WHICH IT IS NECESSARY FOR OCCUPANTS OF AN ADJACENT <br />HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN, SHALL BE IDENTIFIED BY A <br />ROOM TO PASS IN ORDER TO REACH THE ONLY EXIT SHALL FOR THE PURPOSE OF THIS TABLE <br />TACTILE EXIT SIGN WITH THE WORDS, "EXIT ROUTE". <br />BE CONSIDERED AS CORRIDORS. WHERE USED IN CORRIDORS, CLASS B FINISHES MATERIAL <br />3. SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF SINGLE DOOR AND RIGHT SIDE OF DOUBLE <br />NOTE: FORTHCOMING REVISION 1.OX TO ANALYZE THE OCCUPANCY, AREA AND OCCUPANT LOAD OF EACH INDIVIDUAL ROOM <br />SHALL NOT EXTEND MORE THAN 50 FEET BETWEEN SEPARATIONS OF CLASS A FINISH <br />MATERIALS THAT AREA AT LEAST TWO FEET WIDE. <br />DOORS FROM DIRECTION OF EGRESS. <br />OCCUPANT LOAD M <br />4. SIGNAGE AND TACTILE FLOOR DESIGNATIONS SHALL BE LOCATED AT EACH STAIR IDENTIFYING <br />REFER TO Section 803 Wall and Ceiling Finishes FOR COMPLETE REQUIREMENTS FOR FINISHES <br />EACH STAIR BY NAME OR NUMBER. <br />5. FOR A-3 OCCUPANCIES PROVIDE SIGNAGE POSTING THE ROOM CAPACITY. <br />Room Name <br />Occupancy <br />Area <br />Load Factor <br />Occupant Load <br />TRAINING ROOM (M) <br />A-3 <br />1,968 SFJ <br />151 <br />131.2 <br />A-3 1,968 SF 132 <br />6. SIGNAGE AND TACTILE SIGNAGE SHALL BE PROVIDED AT EACH EXIT DOOR WITH DELAYED <br />EGRESS LOCK, AND SHALL BE LOCATED ABOVE AND WITHIN 12" OF DOOR EXIT HARDWARE. <br />SPECIAL INSPECTIONS AND TESTS <br />A. FOR DOORS THAT SWING IN THE DIRECTION OF EGRESS, THE SIGN SHALL READ "KEEP <br />PUSHING. THIS DOOR WILL OPEN IN 15 SECONDS. ALARM WILL SOUND." <br />OFFICES +RESTROOM FOR OFFICES IB 1 2,804 SFJ 1501 1&691 <br />B 2,804 SF 19 <br />B. FOR DOORS IN THE OPPOSITE DIRECTION OF EGRESS, THE SIGN SHALL READ "KEEP <br />PULLING. THIS DOOR WILL OPEN IN 15 SECONDS. ALARM WILL SOUND." <br />PARKING <br />S-2 <br />1 80,273 SFJ <br />200 <br />401.63 <br />1. SPECIAL INSPECTIONS ARE REQUIRED ON NEW CONSTRUCTION AS REQUIRED BY CHAPTER 17 OF THE <br />2018 IBC <br />7. SIGNAGE AND TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT AND ELEVATOR SERVING A <br />S-2 80,273 SF 402 <br />Grand total 85,045 SF 553 <br />2. REQUIRED SPECIAL INSPECTIONS SHALL BE PERFORMED BY A TESTING AGENCY APPROVED BY AHJ <br />REQUIRED ACCESSIBLE SPACE. SIGNAGE SHALL BE INSTALLED INDICATING THE LOCATION OF <br />ACCESSIBLE MEANS OF EGRESS. <br />8. EXITS IN EXCESS OF THOSE REQUIRED BY THE CODE WITHOUT A RAMP AND MORE THAN 24" <br />ABOVE GRADE SHALL HAVE SIGNS "EXIT STAIR DOWN" <br />9. EXIT SIGNAGE SHALL BE INTERNALLY ILLUMINATED AT ALL TIMES WITH EMERGENCY ELECTRICAL <br />BACK-UP POWER. <br />10. EXIT SIGN ILLUMINATION SHALL NOT BE LESS THAN 5 FOOT CANDLES EXIT SIGNS SHALL HAVE <br />TWO POWER SOURCES, ONE FROM THE PREMISES WIRING SYSTEM, THE OTHER FROM <br />BATTERIES. <br />11. FINAL PLACEMENT OF EXIT SIGNS IS SUBJECT TO APPROVAL AND MODIFICATION OF THE FIRE <br />DEPARTMENT FIELD INSPECTOR <br />EXIT ILLUMINATION <br />1. MEANS OF EGRESS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED WITH LIGHT <br />HAVING AN INTENSITY OF NOT LESS THAN ONE FOOT CANDLE AT WALKING SURFACE LEVEL EXIT <br />ILLUMINATION FIXTURES SHALL BE ON A SEPARATE NIGHT LIGHT CIRCUIT WITH BATTERY BACK- <br />UP EXIT ILLUMINATION SHALL BE PROVIDED FOR NOT LESS THAN 90 MINUTES VIA STORAGE <br />BATTERIES, OR ON -SITE GENERATOR. <br />CITY OF 1 4�ERETT <br />REVIEWED FOR E '1 T <br />© MG2. All rights reserved. No part of this document maybe <br />reproduced in any form or by any means without permission in <br />writing from MG2. <br />DSE4_E1 <br />6611 Associated Blvd <br />Everett, WA 98203 <br />DESCRIPTION A DATE <br />ISSUE FOR PERMIT 05,05.2021 <br />MATTHEW L. GOELZER, ARCHITECT <br />1006 REGISTERED <br />N_­ <br />A ARCHITECT _ . <br />STATE OF <br />© MG2, Inc. All rights reserved. No part of this document may <br />be reproduced in any form or by any means without permission <br />in writing from MG2, Inc. <br />PROJECT STATUS <br />Permit Set <br />JOB NUMBER <br />21-5635-01 <br />DRAWN BY CHECKED BY <br />SAC AB <br />SHEET TITLE <br />CODE ANALYSIS <br />SHEET NUMBER <br />G1.10 <br />