Laserfiche WebLink
) a <br /> 2.1.7 - Element 7: Protect Drain Inlets <br /> List and describe BMPs: Storm Drain Inlet Protection (BMP C220) <br /> All storm drain inlets and catch basins made operable during construction shall be protected to <br /> prevent unfiltered or untreated water from entering the drainage conveyance system. However, <br /> the first priority is to keep all access roads clean of sediment and keep street wash water <br /> separate from entering storm drains until treatment can be provided. Storm Drain Inlet <br /> Protection will be implemented for all drainage inlets and culverts that could potentially be <br /> impacted by sediment-laden runoff on and near the project site. <br /> Inlet protection devices shall be cleaned (or removed and replaced)when sediment has filled <br /> the device by one-third (1/3)or as specified by the manufacturer. Inlets shall be inspected <br /> weekly at a minimum and daily during storm events. <br /> Installation Schedules: Storm drain inlet protection shall be installed at the beginning of <br /> construction and will be maintained and adjusted as needed. <br /> Inspection and Maintenance plan: Storm drain inlet protection shall be inspected daily to <br /> ensure it is in good condition and cleaned or replaced as needed. <br /> Responsible Staff: TBD—Construction Erosion Control Lead <br /> Page 113 <br />