Laserfiche WebLink
If the discharge's turbidity is 26 to 249 NTU or the transparency is less than 33 cm but equal to <br /> or greater than 6 cm, the following steps will be conducted: <br /> 1. Review the SWPPP for compliance with Special Condition S9. Make appropriate <br /> revisions within seven days of the date the discharge exceeded the benchmark. <br /> 2. Immediately begin the process to fully implement and maintain appropriate source <br /> control and/or treatment BMPs as soon as possible. Address the problems within 10 <br /> days of the date the discharge exceeded the benchmark. If installation of necessary <br /> treatment BMPs is not feasible within 10 days, Ecology may approve additional time <br /> when the Permittee requests an extension within the initial 10-day response period. <br /> 3. Document BMP implementation and maintenance in the site log book. <br /> If the turbidity exceeds 250 NTU or the transparency is 6 cm or less at any time, the following <br /> steps will be conducted: <br /> 1. Telephone or submit an electronic report to the applicable Ecology Region's <br /> Environmental Report Tracking System (ERTS)within 24 hours. <br /> https://www.ecology.wa.gov/About-us/Get-involved/Report-an-environmental-issue <br /> • Northwest Region (King, Kitsap, Island, San Juan, Skagit, Snohomish, Whatcom): <br /> (425) 649-7000 <br /> 2. Immediately begin the process to fully implement and maintain appropriate source <br /> control and/or treatment BMPs as soon as possible. Address the problems within 10 <br /> days of the date the discharge exceeded the benchmark. If installation of necessary <br /> treatment BMPs is not feasible within 10 days, Ecology may approve additional time <br /> when the Permittee requests an extension within the initial 10-day response period. <br /> 3. Document BMP implementation and maintenance in the site log book. <br /> 4. Continue to sample discharges daily until one of the following is true: <br /> • Turbidity is 25 NTU (or lower). <br /> • Transparency is 33 cm (or greater). <br /> • Compliance with the water quality limit for turbidity is achieved. <br /> O 1-5 NTU over background turbidity, if background is less than 50 NTU. <br /> O 1%-10% over background turbidity, if background is 50 NTU or greater. <br /> • The discharge stops or is eliminated. <br /> Page 124 <br />