September 24, 2018 <br /> HWA Project No. 2015-061-21 <br /> the anticipated settlement of compressible materials at the crane location induced by the <br /> significant depths of proposed new fill. <br /> Downdrag loading for 16-inch and 18-inch diameter piles was evaluated using LRFD methods in <br /> general conformance with the procedures referenced in the FHWA Design and Construction of <br /> Driven Pile Foundations (Hannigan, et al., 1997). For the crane foundation piles, downdrag <br /> loading will occur to approximately Elev. -7 feet. The downdrag loading associated with a <br /> 16-inch diameter pile is about 60 kips. For an 18-inch diameter pile, the downdrag loads are <br /> estimated to be 90 kips. A load factor of 1.1 is recommended to be applied to downdrag loading <br /> (WSDOT, 2016). <br /> Downdrag forces will also be exerted on the piles due to settlement of liquefied materials during <br /> the Extreme Event Limit State. Potentially liquefiable materials extend to El. -37 feet, equal to a <br /> pile penetration depth of about 60 feet below the proposed ground surface of the crane structure. <br /> All materials above this elevation will exert downdrag loading associated with the residual <br /> strength for liquefied materials, and the full strength for non-liquefied materials. However, <br /> downdrag is expected to be higher for smaller events as layers that are predicted to liquefy for <br /> the design event may not liquefy for smaller events. Thus, we provide the resulting estimated <br /> downdrag force using the full-strength properties of the soils above the lowest liquefiable layer <br /> likely to liquefy in smaller events (Elev. -20 ft) and the residual in the lowest liquefiable layer <br /> from Elev. -20 to -37 ft. The resulting load exerted on a 16-inch diameter pile for the liquefied <br /> state is 210 kips. The downdrag force exerted on an 18-inch diameter pile during the liquefied <br /> state is 280 kips. A load factor of 1.0 is recommended to be applied to downdrag loading for the <br /> Extreme Event Limit State (WSDOT, 2016). Piles will need to be driven a sufficient depth into <br /> the non-liquefiable materials to support the loads of the Extreme Event State, which should be <br /> verified during driving. A minimum tip elevation should be required to be about 5 feet into <br /> the non-liquefiable material which is Elev. -42 feet. <br /> Concrete Slab at Crane Structure <br /> In design discussions with KPFF, we understand that the portion of the concrete slab within the <br /> sheet pile wall will be structurally supported by the sheet and/or crane foundation piles. West of <br /> the sheet piles, however, the slab is planned to be constructed on grade. Based on our analyses <br /> with regard to settlements due to grading fill placement, we anticipate of the order of 2 to <br /> 3 inches of settlement between the structurally supported slab and the slab-on-grade. However, <br /> there could be more, depending upon the variability in subsurface conditions. Given the <br /> predicted settlements, we recommend some manner of narrow transfer slab section be included <br /> between the two slabs that could articulate off the structurally supported portion to the slab-on- <br /> grade portion. This will allow the grade-supported slab portion to settle independent of the <br /> structural portion and will minimize the damage to the slab, as well as provide for a smoother <br /> surface transition between the slab sections. <br /> Final Geotechnical Report-3-Acre Park.docx 20 HWA GeoSciences Inc. <br />