My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3535 RIVERFRONT BLVD Geotech Report 2023-02-22
>
Address Records
>
RIVERFRONT BLVD
>
3535
>
Geotech Report
>
3535 RIVERFRONT BLVD Geotech Report 2023-02-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2023 10:23:30 AM
Creation date
2/22/2023 10:18:41 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3535
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 September 24, 2018 <br /> HWA Project No. 2015-061-21 <br /> I <br /> I Table 5—Equivalent Fluid Earth Pressures for the Passive Case(Ultimate Values) <br /> Equivalent Fluid Earth Pressures—Passive Case <br /> Soil Unit <br /> Static Seismic Post-Liquefaction <br /> Sandy Silt <br /> (El. -7.0 ft to 230 pcf(Kp=3.69) 210 pcf(KPE=3.34) 72 pcf(Kp=1.15) <br /> El. -12.0 ft) <br /> I <br /> Above El. -37 ft=80 pcf <br /> Sand Alluvium (Kp=1.28) <br /> 230 pcf(Kp=3.69) 210 pcf(KPE=3.34) <br /> (Below El. -12 ft) Below El. -37ft=230 pcf <br /> I (Kp=3.69) <br /> Shore Armor: Above GWT=210 pcf Above GWT= 180 pcf Above GWT=210 pcf <br /> I (2H:1V)slope <br /> gradient in front Below GWT= 105 pcf Below GWT=90 pcf Below GWT= 105 pcf <br /> of wall (Kp= 1.68) (KPE= 1.44) (Kp= 1.68) <br /> I <br /> I For other walls that may extend below grade on site and support unbalanced earth forces, the <br /> above parameters may be employed for the appropriate soil unit in contact with the walls; likely <br /> to be Old Fill or more recently placed fill materials. Any new fill to be placed behind and in <br /> I close proximity of the sheet pile wall should be considered as surcharge loading and the lateral <br /> earth pressure exerted on the wall should be taken as the in-place unit weight of the fill times the <br /> earth pressure coefficient of the soil unit in contact with the wall. Temporary equipment loads <br /> I and permanent foundation loads that may exert a pressure on the wall should also be taken into <br /> account in wall design, and their pressure contribution should be determined on a case specific <br /> basis. <br /> IThe equivalent fluid pressures for wall design under seismic conditions include combined static <br /> soil loading and seismic loading increment. These are ultimate or non-factored values and the <br /> I seismic load increment is represented by the net difference between the static and seismic cases <br /> provided. The seismic increment may be multiplied by a load factor of 1.0, bearing in mind that <br /> the incremental seismic value is also linearly variable with depth (i.e. triangular distribution). <br /> IWith regard to the passive resistance provided by shore armor, the gradient or inclination of <br /> slope in front of the wall has a very substantial effect (reduction for negative gradient) on the <br /> I value that may be relied upon for design purposes. This is most pronounced for seismic <br /> conditions. For the proposed river bank slope gradient of 2H:1 V in front of the wall, the <br /> recommended equivalent fluid pressures are provided in Table 5. These values are based on an <br /> assumed bulk unit weight of 125 pcf for the rip rap and a friction angle of 40 degrees, which is <br /> Final Geotechnical Report-3-Acre Park.docx 23 HWA GeoSciences Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.