REVISIONS BY
<br />Permit Corrections
<br />1 3.18.22 bGIC
<br />I-FOVDE BLOCKING, FOWEK,
<br />AND CABLE FOF CEILING
<br />MOUNTED MICR05COFE, TO BE J0I3-
<br />SITE LOCATED BY MICKOSCOFE
<br />SUFFLIEP, TYF.
<br />AND CABLE FOIE CEILINGq-1i
<br />MOUNTED MICF�OSCOFE, TO 6E JOv- Tyr.
<br />SITE LOCATED 13Y MICFOSCOFE SEE DETAIL B/4
<br />SUFFLIER, TYF.
<br />FEFLECTEP CLIGHTING PLAN, FLOOF
<br />SCALE:
<br />J-S� f� P _f I I 0,_p s``!`'f" J - I f I I I I I I`,-P&1 0 ,0 ,0 ,�_/`v,�_f,
<br />(_1) ,,,s.f`•f J
<br />FEFLECTEP (FILING & LIGHTING FLAN, 13ASEMENT
<br />a 41 2! 0
<br />5/5" GW[3 O.C. 31/2"
<br />MTL STUDS f\5 FEUD
<br />SOFFIT DETPAIL 9 GFEET & CHECK-OUT
<br />N.T.S.
<br />L 411 1k 5' l
<br />11
<br />GWB CEILING
<br />5/8" GW O.C. 31/2"
<br />MTL STUDS A5I2EQ'D
<br />LED LIGHT COVE IN OF5 #1- #3
<br />LIGHT FIXTURE SCHEDULE
<br />NOTE: Use only UL approved fixtures. Any substitutions of non -rated
<br />fixtures are not approved by designer.
<br />TYPE
<br />QTY
<br />SPECIFICATION
<br />1 X 4 LED Fixture: Corelight Divide
<br />A
<br />3
<br />#DSIWS4L401BUNVSU-JB4
<br />Suface mount, Light Level 4 with Emergency battery
<br />Lamp: LED 74.4W 4000°K color temperature)
<br />1 X 4 LED Fixture: Corelight Divide
<br />B
<br />4
<br />#DSIWS4L401 UNVSU-JB4
<br />Suface mount, Light Level 4
<br />Lamp: LED 74.4W 4000°K color tea erature
<br />1 X 4 LED Fixture: Corelight Divide
<br />C
<br />5 20
<br />#DSIWS2L401 UNVACSU-JB4
<br />S
<br />Suface mount, Light Level 2
<br />Lamp: LED 45.4W 4000°K color tea erature
<br />Suspended 1 X 4 LED Fixture: Corelight Divide
<br />D
<br />2
<br />#DSIWS2L401 UNVAC1 20JB4
<br />Suspended, Light Level 2
<br />Lam : LED 45.4W 4000°K color temperature)
<br />LED Strip Light (mounted above header):
<br />E
<br />1
<br />Lithonia ZL1 N L48 3000LM L/LENS MVOLT 35K, or equal
<br />LED 33W 48" length
<br />6" LED Wafer Thin Recessed Downlight
<br />[\F
<br />5 30
<br />Lithonia WF6LED40KMW
<br />C�
<br />Lamps: 1200lumen LED4000°K(color temperature) 13.6W
<br />Recessed 4" LED downlight:
<br />G
<br />7
<br />Juno 4" #17HYP2 Series Hyperbolic Reflector Trim Module
<br />Clear Alzak cone w/ white trim ring, ICI RALEDG4 remodel housing
<br />Lamps: LED 10.2W3500°K(color temperature)
<br />Dental Track -Pole -Wall light: Verify spec. with Dental Tech.
<br />H
<br />t.bA
<br />Furnished by Owner, installed by Contractor. Backing
<br />required. (exempt) Hard -wired individually.
<br />Wall -Mount Vanity Fixture: Hinkley Filmore #5162HB 2 light Vanity Fixture
<br />1
<br />2
<br />Finish: Oil Rubbed Bronze with Heritage Brass, Dims: 16"W X 7.5"H
<br />Lamps: 2 100W Vintage Filmament Bulbs
<br />Under cabinet fixture: Kelvix UniCab 22" L.
<br />J n
<br />#UC22-3040-010V-120/277-WH
<br />J
<br />S 3
<br />Lamp: Adj. 3000°K - 4000°K (color temperature). (121/0
<br />C� f
<br />To be installed @ front of cabinet behind light valance.
<br />See Detail A/6 for clarification.
<br />Under cabinet fixture: Kelvix UniCab 32" L.
<br />K
<br />n
<br />3
<br />#UC32-3040-010V-120/277-WH
<br />Lamp: Adj. 3000°K - 4000°K (color temperature). (151M
<br />�^
<br />To be installed @ front of cabinet behind light valance.
<br />See Detail A/6 for clarification.
<br />Under cabinet fixture: Kelvix UniCab 40" L.
<br />J
<br />#UC40-3040-010V-120/277-WH
<br />L
<br />5 10
<br />Lamp: Adj. 3000°K - 4000°K (color temperature). (201M
<br />v
<br />To be installed @ front of cabinet behind light valance.
<br />See Detail A/6 for clarification.
<br />Wall -Mount Vanity Fixture: Kohler Components #K-23464-SCLED-BGL
<br />M
<br />1
<br />24"W LED Sconce in Modern Brushed Gold - BGL
<br />Lam s: intra al LED 12W
<br />Decorative LED pendant fixture: dweLED by WAC Lighting
<br />N
<br />2
<br />Houdini LED Chandelier #PD-55906 BK/AB, Black / Aged Brass
<br />Lamps: 6 li ht, 427 lumenes, 16W
<br />LED Tape Light: Nora Lighting, Hi -Output LED tape light #NUTP8-LED
<br />O
<br />-88 feet
<br />Electrician to verify exact length to be ordered. Switched on dimmers.
<br />Lamp: LED 3500°K color temperature). 4W / foot
<br />Sloped ceiling cans: Elco Lighting 5" LED IC Airtight Sloped Ceiling
<br />P
<br />3
<br />Remodel Housing #EL590RICA with Refloctor Trim: EL5123OW
<br />W'ote. 10501m, 30000K color temperature). 39W
<br />Q-1
<br />4
<br />Ceiling mounted Exit sign (Battery Back -Up):
<br />Precise Edge -lit LED Lithonia LRP1GC120/277ELN
<br />Q 2
<br />1
<br />Back mounted Exit sign (Battery Back -Up):
<br />Precise Edge -lit LED Lithonia LRP1 GC1 20/277ELN
<br />R
<br />5
<br />Ceiling mntd Exit sign, 2-sided, directional indicators noted on RCP
<br />Precise Edge -lit LED Lithonia LRP2GC120/277ELN(battery backup)
<br />Emergency Pathway Lighting:
<br />S
<br />9
<br />Eaton Sure-Lite #CU2-LED, White, with battery back-up,
<br />Color: White.
<br />T
<br />3
<br />Recessed Exhaust Fan on switch:
<br />Nu -Tone QTXEN150 150CFM , orequal
<br />U
<br />4
<br />Recessed Exhaust Fan on switch:
<br />Nu -Tone QTXEN200 200CFM , orequal
<br />V
<br />1
<br />Recessed Exhaust Fan on Thermostat:
<br />Nu -Tone QTXEN080 80CFM , orequal
<br />Recessed Exhaust Fan on Thermostat:
<br />W
<br />1
<br />CFM requirements to be provided by Dental Tech based on equipment
<br />specified.
<br />2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over stories and all R1
<br />Administered by_�©2pa2v
<br />Project & Applicant
<br />Information
<br />Project Title
<br />Dr. Tae Youn, Dr. Lewina Youn -2018 WSEC
<br />For Building Department Use: Date: Mar 31, Z�22
<br />In l f
<br />Project Address
<br />1429 N. Broadway Ave.
<br />Everett, WA 98201
<br />Applicant Name
<br />Bobbi Chapman
<br />Applicant Phone
<br />360-417-2634
<br />Applicant Email
<br />becdesigns@gmail.com
<br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waeneigycodes.eom
<br />General Occupancy
<br />All Commercial
<br />General Building Use Type
<br />Office, Medical
<br />Building Cond. Floor Area
<br />3,376
<br />General Project Types
<br />Alteration
<br />New Building or
<br />Addition
<br />Lighting Scope
<br />Alteration
<br />Lighting Scope
<br />Interior Lighting
<br />Project Cond. Floor Area
<br />3,376
<br />Floors Above Grade
<br />I
<br />Compliance Method
<br />Compliance Method 1 - General
<br />Lighting Project Description
<br />Tenant improvement with new lighting to be installed.
<br />Lighting Compliance Scope
<br />Project Type
<br />Interior / Exterior
<br />Luminaire Replacement Scope
<br />Compliance Method
<br />LPA Calculation
<br />Compliance Verification
<br />and Method
<br />(Interior rndudes both interior & parking)
<br />Adjustment
<br />Alteration
<br />Interior Lighting
<br />50% of more replaced
<br />Space by space
<br />No Calculation Adjustments allowed
<br />COMPLIES
<br />Additional Efficiency
<br />Options Included
<br />Interior Lighting Power Allowance -.Space by Space
<br />General Space Type
<br />Specific Space Type
<br />Ceiling
<br />Gross Interior Area (SF)
<br />LPA (Watts/SF)
<br />Total Watts Allowed
<br />Total Proposed Watts
<br />Compliance Status
<br />Height (Ft)
<br />(SF x LPA x 1)
<br />(LPD + Display LPD)
<br />Corridors
<br />General
<br />707
<br />0.41
<br />290
<br />Electrical/mechanical
<br />23
<br />I.0.43
<br />10
<br />Electrical/mechanical
<br />16
<br />0.43
<br />7
<br />Electrical/mechanical
<br />30
<br />0.43
<br />13
<br />Electrical/mechanical
<br />64
<br />0.43
<br />27
<br />Laboratory
<br />General
<br />112
<br />1.33
<br />149
<br />Laundry/washing area
<br />57
<br />; 0.53
<br />30
<br />Lobby
<br />General
<br />179
<br />0.84
<br />150
<br />Locker room
<br />48
<br />'.0.52
<br />25
<br />Lounge/breakroom
<br />General
<br />451
<br />0.59
<br />266
<br />Office
<br />Enclosed less than 250 sf
<br />125
<br />0.74
<br />93
<br />Office
<br />Open plan
<br />205
<br />0.61
<br />125
<br />Restroom
<br />General
<br />153
<br />0.63
<br />97
<br />Stairwell
<br />General
<br />129
<br />0.49
<br />63
<br />Storage room
<br />50-100 sf
<br />58
<br />0.38
<br />22
<br />Healthcare facility
<br />Exam/treatment room
<br />846
<br />1.40
<br />1,185
<br />Healthcare facility
<br />Imaging room
<br />74
<br />0.94
<br />69
<br />Healthcare facility
<br />Nurse station
<br />75 1
<br />1.17
<br />88
<br />Proposed Total LPD
<br />- - 2568.5
<br />Totals
<br />2,708
<br />2,568
<br />COMPLIES
<br />Proposed Lighting Power Density
<br />Watts or
<br />Total Watts
<br />Fixture Type
<br />Fixture ID
<br />Quantity of
<br />Wattage Limit
<br />Total Linear
<br />Watts per Linear
<br />Proposed
<br />Fixtures (#F)
<br />per Fixture
<br />Feet (LF)
<br />Foot (WpLF)
<br />(#F x WpF) or
<br />(WpF)
<br />�(LFx WpLF)
<br />Individual Fixtures
<br />Decorative
<br />'N'
<br />2
<br />96
<br />'192
<br />Troffer
<br />'A'
<br />3
<br />30
<br />90
<br />Troffer
<br />C'
<br />20
<br />22
<br />448
<br />Troffer
<br />B'
<br />4
<br />30
<br />120
<br />Recessed downlight
<br />'P'
<br />3
<br />39
<br />117.-'
<br />Recessed downlight
<br />'F
<br />2
<br />14
<br />27
<br />Recessed downlight
<br />'F-2'
<br />2
<br />14
<br />27
<br />Recessed downlight
<br />T'
<br />6
<br />14
<br />82
<br />Recessed downlight
<br />'G'
<br />7
<br />1071
<br />Recessed downlight
<br />'F
<br />6
<br />14
<br />' $2'•`-
<br />Recessed downlight
<br />'F'
<br />14
<br />14
<br />190
<br />Suspended
<br />'D'
<br />2
<br />22
<br />45
<br />Task lighting
<br />'h
<br />3
<br />15
<br />45
<br />Under -cabinet
<br />'L'
<br />10
<br />20
<br />200
<br />Under -cabinet
<br />T
<br />3
<br />12
<br />36
<br />Wall -mounted
<br />11,
<br />2
<br />200
<br />400
<br />Wall -mounted
<br />'E'
<br />1
<br />33
<br />33
<br />Wall -mounted
<br />'M'
<br />'1
<br />12
<br />12,
<br />Linear Fixtures
<br />LED ship
<br />'O'
<br />88
<br />4
<br />352
<br />Proposed Total LPD
<br />2568,5
<br />Dr. The Youn, Dr. Lewina Youn - 2018 WSEC
<br />GENERAL CEILING & LIGHTING NOTES
<br />1. GWB Ceiling at same height as currently.
<br />2. Undercabinet lighting: Electrician to provide conduit to each undercabinet
<br />light bank and install fixtures after cabinetry has been installed. Sizes
<br />have been specified per plans, but may change due to site cabinet
<br />conditions. Electrician is responsible for site -verifications before
<br />ordering and installing. Mount behind valance at FRONT of upper
<br />cabinet. See Detail A/6 for location and wiring. Run continuously with
<br />fixtures butted end -to -end.
<br />3. Sound System Supplier to provide volume controls and speakers as noted
<br />on plan. Speaker: "Lowell' #81oT70 or better. Run cable back to
<br />component location in Tech Closet. Verify any changes with Designer
<br />prior to installation.
<br />4. Design of new or relocation of existing by HVAC by Sub -Contractor.
<br />Insulate mechanical supply ducts with batting or duct board. Maximum
<br />12" flex duct runs. Minimum (4) zones. Use linear or square recessed
<br />ceiling diffusers - round diffusers will not be accepted. A sound boot is
<br />required in all plenum -rated return -air grilles. Provide alternate pricing
<br />of abandoning central furnace and installing individual mini -split ductless
<br />units.
<br />S. Painter to paint speaker covers and HVAC grilles to match ceiling color if
<br />in GWB ceiling.
<br />6. Occupancy sensors are to be installed in rooms (fully enclosed by walls) R
<br />less than 300 square feet that are designed for meeting, conferencing and
<br />storage purposes. These rooms include but are not limited to Private
<br />Offices and Staff Lounge.
<br />7. Switching layout is to comply with the 2018 Washington State Energy
<br />Code.
<br />OF EVERETT
<br />IIE10VE D 0 R P E R M E"
<br />°'coo0
<br />a) N U U
<br />-0 ti N C
<br />+ E .2)
<br />�M�-0
<br />U 0
<br />0
<br />U
<br />m
<br />A]
<br />- REFLECTED CEILING
<br />& LIGHTING 'FLM
<br />- SOFFIT 19C-1I-IEDULE
<br />- LIGHTING SYMBOLS
<br />- GENEFAL CEILING
<br />& LIGHTING NOTES
<br />- LIGHT FIXTURE
<br />SCHEDULE
<br />- 2018 WSEC LIGHTING
<br />COMFLIANCE FORM
<br />- CEILING PET/ AIL
<br />DATE: 11.3.2021
<br />SCALE: 1/4'' =1'-0"
<br />DRAWN: hoc
<br />JOB: YOUN
<br />SHEET: 4
<br />C� +2COVE�?