REVISIONS By <br />ermit Correctim-, <br />1 5.18.22 bqc <br />DISPENSING UNIT <br />FOE FAFEF TOWELS c <br />CABINET 1)00� WALL <br />CUT HOLE IN BOTTOM <br />OF UFFEE CABINET AT <br />BACK FOE DISFENSING <br />UNDEFCABINET UNIT. SECUEE UNIT TO <br />LIGHT FIXTUEE CABINET. VEKF'r SIZE <br />EULF3 OF UNIT W/ SPECS. <br />FI;OM STUD FACETO <br />SOUGH -IN NOTE: THIS LIGHTING DETAIL <br />AFFLIE5 EVEN WHEN THEME I5 <br />NO 1)I5FEN5EE FEE5ENT <br />DISFEN51NG UNIT/EIGHT VALANCE DETAIL <br />ELED FINS <br />;EFT 1/4'' <br />�5 <br />� F(� <br />14" W/ P-LAM <br />ACE - FL-3 <br />�T HOOKS'L' <br />D TOP HOOK, <br />BOTTOM ADA <br />)MhLIAI`iT HOOK <br />NOTE: COAT PACKS TO BE HUNG WITH <br />INVISIBLE HAFDWAFE. (I.E. FFEHCH CLEAT <br />OP SIM.) <br />LL <br />FE HOLES AT <br />).C. TO ACCEFT <br />5 <br />ADJ. WIDTH CUDDY DETAIL <br />U N.r.5. <br />LEAD ANON ^ ^ /' <br />t, <br />N <br />L3/4" W/F-LAM <br />SUEFACE. <br />N <br />1 1 <br />1 <br />i 1 <br />i 1 <br />1 <br />NOTE: LEAD AMON EACK5 TO BE HUNG WITH <br />INVISIBLE HAEDWFE. (I.E. FFENCH CLEAT <br />OF 51M.) <br />cc LEAD ANON HANGEE DETAIL <br />N.T. S <br />SHELF TOF, SIDE OF CABINET <br />(FFONT PIECE <br />NOT SHOWN) FULL EXTENSION <br />HAEDWAEE N <br />SUFFOET FIECE <br />FOE HAFDWAEE <br />CUT-AWT r FFOHT VIEW DETAIL <br />COAT HOOK <br />N.T.S. <br />P-1 AM <br />J_ (1) FOW OFADJ. WIDTH <br />SCU5FIES: NOTE: ALL VISIBLE <br />S 1/4'' CLEAF FLEXI PIVIDE25-- SUKFACE5TO BE HFL <br />S SET HOLES O.C. <br />S F-LAM QUAF TZ STONE TOIL WITH C-)S WOEK5UFFACE 1-0EP SED EDGE <br />S <br />FL-1 <br />C� <br />C) <br />C) FEY FEGLET PE -VEAL, <br />#MWIN5 75-50 <br />N FINISH: BUFFED SATIN <br />BFA55 (NOTE: MITFE AT <br />BLACK LPL OVEE N OUTSIDE COFNEF) <br />M DF WITH <br />FEMOVEABLE FL-1 <br />ACCESS PANELS <br />- FL -1 TOEKICK S <br />� � 5 <br />WALL BASE <br />S <br />CHECK, IN/OUT DESK DETAIL N <br />� � G ADJ.WIDTH CU�PIES � <br />S S <br />S S <br />S S <br />'TO ATTACH F LAM <br />L S woF r,SUKFACE <br />V <br />> SHELF W/ CONCEALED FOP <br />6 1" =1'-0" <br />FOE COEDS, ETC: <br />HOLD SHELF 2" <br />FOI?WA\P FEOM <br />BACK OF CABINET. <br />,1 <br />�1 <br />CABINET <br />BOX 1 1 <br />CABINET <br />HANDLE 1 POLL OUT SHELF <br />HAEDWAFE, FULL <br />EXTENSION <br />CABINET SEECABINET NOT <br />1 '15OX" FOE SFECIFICATIOH. <br />1 <br />NOTE: POLL-OUT5 FOE EQUIPMENT TO BE MADE _ - - FINISHED F.LAM SHELF AND FFONT, <br />OF FLA5TIC LAMINATE, UNLE55 OTHEFWISE NOTED. HIDING FULL EXTENSION <br />HAFDWAFE ON TOP AND SIDES. <br />OFTIOHAL NOTE: <br />SEE DETAIL _/6 FOE 501-11) SUEFACE <br />EOLL-OUT DETAIL IN STEEILIZATION. <br />POLL -OUT SHELF WITH CONCEALED HAFIMAPE - F1_ASTI(-/ I-AMINATF AFF1 rAmN <br />S <br />QUARTZ STONE TOP WITH <br />S <br />S <br />EASED EDGE <br />5 <br />S <br />S <br />_ <br />5 <br />0 <br />S <br />5 <br />S <br />S <br />S <br />F1zY REGLET PvEVEAL, <br />S <br />S <br />�c <br />- #MWIH575 �J <br />S <br />N <br />FINISH: BUFFED SATIN <br />BEA55 <br />BLACK LPL OVEF <br />S <br />5 <br />M DF WITH <br />EEMOVEABLE FL-1 <br />S <br />ACCESS FANEL5 <br />FL -1 TOEKICK. <br />WALL BASE <br />S <br />CHECK IN/OUT DESK DETAIL N <br />S <br />H <br />ADA ACCSSSLE SECTION <br />6 <br />1 =1 - 0''S <br />SS <br />SS <br />Our review of cabinet shop drawings does not constitute an approval of details <br />that are inconsistent with our initial elevations® We cannot be held responsible <br />for errors to the Cabinetmaker. please feel free to call us for clarifications during <br />the drafting of shop drawings. <br />1. Casework construction to be white low-pressure laminate over 3/4" industrial <br />board. <br />2. Shelving to all be adjustable. Exposed shelving and exposed cabinet box interiors to <br />be high-pressure laminate (i.e.: vertical chart storage, computer cabinets without <br />doors, other open shelving in Business Office and corridors). The front edge of all <br />concealed adjustable shelves to be high-pressure laminate. For shelving in General <br />Storage, white low-pressure laminate is acceptable. <br />,i. Countertops to be plastic laminate bonded over 2/4" industrial board. <br />4. Contractor shall provide 1" square tubular steel bracing for all unsupported <br />countertops. Bracing should extend two-thirds the depth of the countertop and as <br />far down wall as deemed necessary. See Detail I/2. Cabinetmaker to verify location <br />and requirements with Contractor. <br />,. Backsplashes to be 1 x 4 wrapped with plastic laminate unless otherwise noted. If <br />full backsplashes to the underside of the upper cabinets are called out on the plans, <br />they are to be 3/4" thick (unless solid surface is specified) and side splashes are <br />lowered to 4" unless illustrated differently. Check Elevations. <br />6. Where backsplashes are eliminated, scribe for tight fit to wall. <br />7. Self -edges to be 1-1/2" and plastic laminate, unless otherwise noted. If other edges, <br />such as wood or stone, are specified then a detail of the profile will be provided. <br />S. Toekicks are 3/4" x 4" unfinished particle board for application of specified base <br />materials in general casework areas only. Toekicks to be 6"H finished p-lam on <br />ALL CABINETRY in Operatories. <br />9. Doors and drawer heads to be plastic laminate with white low-pressure cabinet <br />liner. PVC edgebanding is acceptable ONLY if an exact match can be made and <br />only in areas where the laminate and edgebanding are not seen on the <br />same plane. Otherwise, laminate banding must be used. A submittal to Designer <br />is required if PVC edgebanding is proposed. <br />io. Drawers to be white low-pressure laminate bonded over 3/4" industrial board with <br />doweled construction. ALL FILE DRAWERS TO BE LETTER -SIZED HANGING <br />FRONT -TO -BACK UNLESS OTHERWISE NOTED. THEY SHOULD BE <br />CONSTRUCTED TO RECEIVE THE PENDAFLEX HANGERS WITHOUT A <br />SEPARATE RACK (including the top -mounted file tabs). <br />1i. Drawer slides are 3/4" extension Accuride 50# capacity, or equal. Full -extension <br />Accuride too# slides on all file drawers, or equal. Blum 125' self -closing hinges, or <br />equal. <br />12. Cabinetmaker to provide keyboard tray/mouse tray combo per specification noted <br />on Miscellaneous Hardware Schedule, Sheet 5. <br />1i. Pulls are standard to meet barrier -free codes. Hardware specification called out on <br />Door Hardware Schedule. <br />14. Locks to be included only where specified on elevations; finish to match wire pulls or <br />verify with Designer. <br />1s. Electrical grommets to be included on all desk -height surfaces in kneeholes. <br />Cabinetmaker to coordinate exact grommet locations with Doctor. Power, phone <br />and computer jacks will be installed 18" off floor in kneeholes and cords brought <br />through grommets. Use putty colored grommets unless otherwise noted on Plastic <br />Laminate Schedule. <br />16. No center stiles unless approved by Designer before fabrication. <br />17. Plastic laminates will be selected from Nevamar, WilsonArt, Formica, Pionite, <br />Arborite and/or LaminArt. See Cabinet Finish Schedule for colors and materials. <br />If any surface is not clearly specified, call Designer. <br />18. PROVIDE MARINE -GRADE PLYWOOD OR M.R. BOARD FOR CABINETS <br />AROUND STERILIZER(S) & HYDRIM IN STERILIZATION. TO AVOID <br />DELAMINATION FROM MOISTURE, DO NOT PLACE SEAMS IN LAMINATE <br />UNDER EQUIPMENT. <br />19. Interior finished dimensions of upper cabinets should be 12" clear, minimum, unless <br />otherwise noted. If Cabinetmaker is providing Operatory cabinets, upper cabinets <br />are to be 9" deep EXTERIOR clear. Where upper cabinets do not have undereabinet <br />light valance, the bottom of the cabinet should be finished in high-pressure <br />laminate. <br />20. Refer to Miscellaneous Hardware Schedule for dispenser specifications. See Detail <br />A/6 for mounting detail. Cabinetmaker to verify width of dispenser and mounting <br />bracket and ensure the clear width of cabinet is sufficient to adequately remove the <br />lid of dispenser. <br />21. Cabinetmaker to verify chart size with Doctor, and then determine chart rack <br />dimensions accordingly. To prevent sagging of shelves, horizontal sections should <br />not exceed 30. Install vertical wire dividers, front -to -back, equa 54D valsAO T <br />not more than 12" for chart support. REVIEWED FOR PERM11' <br />22. Undereabinet lighting to be mounted behind valance at FRONT of upper cabinet. <br />Sides of upper cabinet boxes must not extend below cabinet bottom to allow the <br />installation of this lighting in a continuous line. See mounting Detail A/6. <br />2;J. Self -edges to extend beyond cabinet door and drawer faces below ruin. of 1/2" to <br />max. of 1". (i.e. not flush). <br />24. Waste rings are to be placed in the counter as shown on Interior Finishes Plan, <br />Sheet 5, so as not to intrude on possible clear workspace. <br />WM <br />- CA13hE1­ PEALS <br />- GENEF/�L CA51NETY <br />HOTES <br />- GFEET/CHECCUT <br />DESK PETALS <br />0 <br />o <br />1 J <br />DATE: 11.3.2021 <br />ALE: A5 NOTED <br />DRAWN: bac <br />JOB: YOUN <br />25. Where wood -grain laminates are used, all grain on all surfaces to be run vertically <br />unless otherwise specified. <br />9 +2COVER <br />OF: EFiEETS <br />