Laserfiche WebLink
iti <br />®N <br />EXISTING SHEATHING OR NEW PER SCOPE AND AS REQUIRED <br />EXISTING W.R.B TO REMAIN <br />EXISTING WOOD PICKET RAILING TO REMAIN <br />NEW SHIM FOR SLOPE <br />— EXISTING LAP SIDING, REMOVE AND RE -INSTALL 2 OR 3 COURSES <br />OF LAP SIDING TO PERFORM FLASHING WORK <br />NEW 24 GA. METAL COPING CAP WITH 1/2" --� <br />HEMMED DRIP EDGE <br />EXISTING CEDAR PLATE OR NEW TO MATCH EXISTING - <br />— SELF-ADHESIVE FLASHING OR LIQUID -FLASHING MEMBRANE <br />— STARTER STRIP <br />NEW CEDAR TRIM TO MATCH EXISTING <br />— NEW 24 GAUGE METAL DECK TO WALL FLASHING <br />NEW CONTINUOUS 24 GA. METAL DECK TO WALL <br />FLASHING, PLANE TOPPING SLAB EDGE TO <br />— NEW WATERPROOF DECK MEMBRANE - INSTALL PER <br />ACCEPT FLASHING C11 <br />MANUFACTURER'S SPECIFICATIONS <br />NEW WATERPROOF DECK MEMBRANE <br />— NEW CONCRETE TOPPING SLAB <br />- INSTALL PER MANUFACTURER'S <br />SLOPE <br />SPECIFICATIONS <br />SLOPE { <br />NEW SHEATHING PER STRUCTURAL — <br />FRAMING PER STRUCTURAL <br />ti r <br />Scale: 3" =1' - 0" <br />1im <br />NOTE: <br />24 GAUGE FULLY SOLDERED METAL <br />FLASHING <br />CUT FLASHING PROPERLY WHERE TREAD END <br />INTERSECTION WITH ADJACENT CURB,TYP. <br />AT BOTTOM OF STAIR <br />Flashing at Stair to Curb <br />Scale: N.T.S <br />NEW CONCRETE TOPPING SLAB " <br />NEW SHEATHING PER STRUCTURAL i <br />FRAMING PER STRUCTURAL <br />Flashing at Wal <br />Scale 3" =1' 0" <br />Scale: 3" =1' - 0" <br />4" 4" <br />z <br />SEALANT e N <br />V.LF <br />------------------- <br />2-PIECE METAL FLASHING <br />24 GA. BONDERIZED FLASHING W/ <br />z SEALANT <br />NEW BACKER ROD AND SEALANT <br />N NEW SELF ADHESIVE NEW WATERPROOF DECK COATING, <br />FLASHING MEMBRANE INSTALL PER MANUFACTURER'S 24 GA. 2-PIECE METAL FLASHING, SET IN <br />If <br />SPECIFICATIONS BED OF SEALANT, SEE DETAIL ABOVE <br />SEALANT NEW CONCRETE EXISTING DECK COATING TO REMAIN <br />SLAB EXISTING CONCRETE SLAB <br />REMAIN <br />EXISTING OR NEW WALKWAY FRAMING, REPAIR <br />PER STRUCTURAL <br />NEW 1 X 2 TRIM TO MATCH EXISTING <br />2 CONTINUOUS VENT STRIP <br />NEW %" TYPE'X' GYPSUM SOFFIT <br />NEW VINYL VENTED SOFFIT TO MATCH EXISTING <br />EXISTING OR NEW VINYL'J' CHANNEL TO <br />MATCH EXISTING <br />EXISTING LAP SIDING TO REMAIN, TYP. <br />EXISTING WEATHER -RESISTIVE TO REMAIN, TYP <br />EXISTING OR NEW SHEATHING, PER SCOPE <br />AND AS REQUIRED <br />EXISTING SHEATHING <br />TO REMAIN, TYP. — <br />EXISTING W.R.B TO <br />REMAIN, TYP. <br />EXISTING LAP SIDING, <br />REMOVE AND <br />RE -INSTALL 2 OR 3 <br />COURSES OF LAP <br />SIDING TO PERFORM <br />FLASHING WORK — <br />NEW SELF-ADHESIVE <br />FLASHING MEMBRANE <br />OR LIQUID -FLASHING <br />NEW 24 GA. METAL <br />FLASHING W/ 1/2" <br />HEMMED DRIP EDGE <br />Scale: 3" =1' 0" <br />V <br />Z EXISTING OR NEW WALKWAY FRAMING, <br />REPAIR PER STRUCTURAL 7 <br />2" CONTINUOUS VENT STRIP <br />NEW %" TYPE'X' GYPSUM <br />SOFFIT <br />Soffit Termination at Overhan <br />Scale: 3" = 1' - 0" <br />NEW VINYL VENTED SOFFIT TO MATCH EXISTING <br />NEW 1 X 2 TRIM TO MATCH EXISTING <br />EXISTING OR NEW VINYL'T CHANNEL TO MATCH <br />EXISTING <br />EXISTING FRAMING TO REMAIN <br />EXISTING PLYWOOD OR NEW TO MATCH <br />EXISTING, PAINT <br />SEALANT <br />EXISTING CEDAR TRIM OR NEW TO MATCH EXISTING <br />Scale: N.T.S <br />Scale: 3" = 1' - 0" <br />NOTES: <br />1. Verify all conditions in the field. <br />NOTE: <br />24 GAUGE FULLY SOLDERED METAL <br />FLASHING <br />z <br />AT BOTTOM OF STAIR <br />BOTTOM FLANGE OF VENT <br />R" COLLAR SHALL COVER TOP <br />OF SIDING, V.I.F. <br />EXTEND NOTE: WHERE MULTIPLE VENTS <br />SLEEVE 4" MIN. OCCUR, GANG UNDER ONE <br />O OVER HOOD. VERIFY WITH ARCHITECT. <br />EXISTING <br />DUCT 3„ <br />SLOPE <br />DVABLE VENT <br />ER. ATTACH WITH <br /><ETED FASTENERS <br />IBRANE <br />3E METAL <br />FRIG <br />=TAL VENT COVER <br />kCH TO <br />SEALANT <br />:RED VENT <br />RED <br />: BARRIER <br />AS NECESSARY <br />RY <br />KILBURN <br />ARCHITECTS LLC <br />135 Lake Street South <br />Suite 250 <br />Kirkland, WA 98033 <br />Tel: 206.682.521 1 <br />Fax: 206.682,1403 <br />www.kilburnarchitects.com <br />7302 <br />\ REGISTERED <br />ARCHITECT <br />tCH <br />D KILBURN <br />1�ASHINGTOIV <br />Bluffs at Evergreen <br />Walkway Repair <br />(Bldg. C) <br />2 West Casino Road <br />Everett, WA 98024 <br />Release Date <br />permit 9.21.2022 <br />Am2ml <br />© 2022 KILBURN ARCHITECTS, LLC <br />