Laserfiche WebLink
NOTES:GENERAL WE <br />1. THE CONTRACTOR SHALL OBTAIN AND HAVE AVAILABLE COPIES OF THE APPLICABLE <br />GOVERNING AGENCY STANDARDS AT THE JOB SITE DURING THE RELATED CONSTRUCTION <br />OPERATIONS, <br />2. CONTRACTOR SHALL ENSURE THAT ALL NECESSARY PERMITS HAVE BEEN OBTAINED <br />PRIOR TO COMMENCING WORK, <br />3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION <br />AND DEPTH OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION WHETHER SHOWN ON <br />THESE PLANS OR NOT. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST ON THIS SITE. <br />ONLY THOSE UTILITIES WITH EVIDENCE OF THEIR INSTALLATION VISIBLE AT GROUND <br />SURFACE OR SHOWN ON RECORD DRAWING PROVIDED BY OTHERS ARE SHOWN HEREON. <br />EXISTING UNDERGROUND UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY AND ARE <br />SUBJECT TO A DEGREE OF UNKNOWN VARIATION. SOME UNDERGROUND LOCATIONS <br />SHOWN HEREON MAY HAVE BEEN TAKEN FROM PUBLIC RECORDS. BARGHAUSEN <br />CONSULTING ENGINEERS, INC. ASSUMES NO LIABILITY FOR THE ACCURACY OF PUBLIC <br />RECORDS OR RECORDS OF OTHERS. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR <br />SMALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL <br />PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. <br />4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND <br />SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE PRIOR TO THE INITIATION <br />OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS <br />RELATIVE TO THE SPECIFICATIONS OR THE RELATIVE CODES, IT IS THE CONTRACTOR'S <br />RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD IN WRITING PRIOR TO <br />THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT <br />ENGINEER SHALL CONSTITUTE ACCEPTANCE OF FULL RESPONSIBILITY BY THE <br />CONTRACTOR TO COMPLETE THE SCOPE OF WORK AS DEFINED BY THE DRAWINGS AND <br />IN FULL COMPLIANCE WITH LOCAL REGULATIONS AND CODES. <br />5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE APPROPRIATE UTILITIES <br />INVOLVED PRIOR TO CONSTRUCTION. <br />6. INSPECTION OF SITE WORK WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE <br />GOVERNING JURISDICTION. INSPECTION OF PRIVATE FACILITIES WILL BE ACCOMPLISHED <br />BY A REPRESENTATIVE OF THE OWNER. IT SHALL BE THE CONTRACTOR'S <br />RESPONSIBILITY TO NOTIFY THE INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING <br />ALL CONSTRUCTION. <br />7. PRIOR TO ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY THE CONTRACTOR SHALL <br />CONTACT THE AGENCY AND/OR UTILITY INSPECTION PERSONNEL AND ARRANGE ANY <br />REQUIRED PRE -CONSTRUCTION MEETING(S). CONTRACTOR SHALL PROVIDE ONE WEED <br />MINIMUM ADVANCE NOTIFICATION TO OWNER, FIELD ENGINEER AND ENGINEER OF <br />PRE -CONSTRUCTION MEETINGS, <br />D. THE CONTRACTOR IS RESPONSIBLE FOR WORKER AND SITE SAFETY AND SHALL COMPLY <br />WITH THE LATEST OSHA STANDARDS AND REGULATIONS, OR ANY OTHER AGENCY HAVING <br />JURISDICTION FOR EXCAVATION AND TRENCHING PROCEDURES. THE CONTRACTOR IS <br />RESPONSIBLE FOR DETERMINING THE "MEANS AND METHODS" REQUIRED TO MEET THE <br />INTENT AND PERFORMANCE CRITERIA OF OSHA, AS WELL AS ANY OTHER ENTITY THAT <br />HAS JURISDICTION FOR EXCAVATION AND/OR TRENCHING PROCEDURES. <br />9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, <br />SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS <br />TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT <br />PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE <br />CONTRACTOR. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT <br />NORMAL TRAFFIC FLOW SMALL REQUIRE AT LEAST ONE FLAGGER FOR EACH LANE OF <br />TRAFFIC AFFECTED, <br />10. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ALL <br />ADJACENT PUBLIC AND PRIVATE PROPERTIES AT ALL TIMES DURING CONSTRUCTION. THE <br />CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF ALL EXISTING UTILITY <br />SERVICES THAT ARE TO REMAIN OPERATIONAL WITHIN THE CONSTRUCTION AREA <br />WHETHER SHOWN OR NOT SHOWN ON THE PLANS, <br />11. TWO (2) COPIES OF THESE APPROVED FLANS MUST BE ON THE JOB SITE WHENEVER <br />CONSTRUCTION IS IN PROGRESS, ONE (1) SET WITH RECORDS OF AS -BUILT <br />INFORMATION SHALL BE SUBMITTED TO BARGHAUSEN CONSULTING ENGINEERS, INC. AT <br />COMPLETION OF PROJECT. <br />12. CONTRACTOR SHALL OBTAIN SERVICES OF A LICENSED LAND SURVEYOR TO STAKE <br />HORIZONTAL CONTROL FOR ALL NEW IMPROVEMENTS. STAKING CONTROL SHALL BE <br />TAKEN FROM ELECTRONIC PLAN FILES PROVIDED BY BARGHAUSEN CONSULTING <br />ENGINEERS, INC. <br />13. CONTRACTOR SHALL REQUEST FROM BARGHAUSEN CONSULTING ENGINEERS, INC., PRIOR <br />TO ANY CONSTRUCTION STAKING CAR CONSTRUCTION WORK, A FORMAL CONSTRUCTION <br />RELEASE PLAN SET OR SPECIFIC RELEASE IN WRITING. THE APPROVED AGENCY PERMIT <br />DRAWINGS WILL NOT BE CONSIDERED CONSTRUCTION RELEASE PLANS BY BARGHAUSEN <br />CONSULTING ENGINEERS, INC. UNLESS BARGHAUSEN CONSULTING ENGINEERS, INC. HAS <br />GIVEN A FORMAL WRITTEN RELEASE OR ISSUED A CONSTRUCTION RELEASE PLAN SET. <br />I <br />THE LOCATION OF THE EASEMENTS SHOWN ON THIS SHEET SET WERE ADDED BASED ON THE <br />INFORMATION INCLUDED IN THE TITLE REPORT UNDER FIRST AMERICAN TITLE INSURANCE <br />COMPANY NO. NCS61067959-OR1, DATED MAY 12, 2021. THESE EASEMENTS WERE NOT <br />SURVEYED, THEREFORE BARGHAUSEN CONSULTING ENGINEERS DOES NOT GUARANTEE THE <br />ACCURACY OF EASEMENT LOCATIONS SHOWN ON THESE PLANS. <br />m THE FOLLOWING OLLOWING SOILS REPORT FOR THE SITE SHALL BE <br />CONSIDERED PART CL THESE CONSTRUCTION DOCUMENTS: <br />GEOTECHNICAL ENGINEERING REPORT <br />OFC 852 FUEL STATION <br />4919 EVERGREEN WAY <br />EVERETT, WASHINGTON 98203 <br />DATED JANUARY 7, 2020 <br />SOIL INVESTIGATION AS PERFORMED BY: <br />THE RILEY GROUP, INC. <br />17522 BOTHELL WAY NORTHEAST <br />BOTHELL, WASHINGTON 98011 <br />PHONE: (425) 415-0551 <br />FAX: (425) 415-0311 <br />2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE <br />THAT ALL PROVISIONS OF THE SOILS REPORT FOR THE SITE BE <br />OBSERVED AND COMPLIED WITH DURING ALL PHASES OF THE SITE <br />PREPARATION, GRADING OPERATIONS, FOUNDATION, SLAB, AND PAVING <br />CONSTRUCTION. <br />1 ANY PROVISIONS OF THE SOILS REPORT WHICH CONFLICTS WITH <br />INFORMATION SHOWN ELSEWHERE ON THESE DRAWINGS, OR WHICH <br />REQUIRE FURTHER CLARIFICATION, SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT/ENGINEER FOR DETERMINATION. <br />4. A REPRESENTATIVE OF THE SOILS ENGINEER SHALL BE AVAILABLE TO <br />OBSERVE AND APPROVE THE EARTHWORK OPERATIONS AND TO <br />VERIFY FIELD CONDITIONS AS WORK PROCEEDS. THE SOILS ENGINEER <br />SHALL SUBMIT FIELD REPORTS CERTIFYING THAT THE METHODS AND <br />MATERIALS OF THE EARTHWORK OPERATIONS WERE IN ACCORDANCE <br />WITH THE RECOMMENDATIONS OF THE SOILS INVESTIGATION AND <br />THAT THE WORD WAS PERFORMED TO HIS/HER SATISFACTION. <br />5. THE SOILS ENGINEER SHOULD BE NOTIFIED AT LEAST FIVE (5) <br />WORKING DAYS PRIOR TO ANY SITE CLEARING OR GRADING, <br />6. THE CONTRACTOR SHALL QUALIFY ANY LIMITATIONS TO SOILS <br />INSPECTIONS WITHIN BID PROPOSAL. <br />LEGAL DESCRIPTION: <br />LOT 1 OF CITY OF EVERETT BINDING SITE PLAN NO. 10-003 FOR <br />CLAREMONT VILLAGE, AS RECORDED UNDER RECORDING NO. <br />201009105004, BEING A PORTION OF SOUTH HIGHWAY ADDITION TO <br />EVERETT, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 12 <br />OF PLATS, PAGE 10, AND ALSO BEING A PORTION OF CLAREMONT <br />HEIGHTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 12 <br />OF PLATS, PAGE 43, RECORDS OF SNOHOMISH COUNTY, WASHINGTON; <br />SITUATE IN THE CITY OF EVERETT, COUNTY OF SNOHOMISH, STATE OF <br />WASHINGTON, <br />HORIZONTAL DATUM: NAVD 83/11 <br />HORIZONTAL DATUM FOR THIS SURVEY IS NAD 3/11 PER WSDOT, <br />WSDOT CONTROL POINT NO, 711 (GP31005-19) WAS HELD FOR <br />POSITION, AND A LINE BETWEEN SAID POINT NO. 7118 (GP31005-1 9 <br />AND CONTROL POINT NO. 7126 (IN'CA 121 ) WAS HELD FOR ROTATION, <br />BEING NORTH 00@19`46" WEST, <br />VERTICALDATUM: NAVD 88 <br />VERTICAL DATUM FOR THIS SURVEY IS NAVD $8 PER WSDOT, WSDOT <br />VERTICAL CONTROL POINT NO, 7118 (GP31005-1 9) WAS HELD FOR <br />ELEVATION, BEING 223.576Q(NAVD 88) <br />REFERENCE SURVEYSn <br />1. CITY OF EVERETT BSP NO. 10-003 AFN. 201009105004 (R 1) <br />ADDRESS: <br />4919 EVERGREEN WAY, EVERETT WA 98203 <br />TAX PARCEL UMBER: <br />0051900000101 <br />LOT AREA: <br />229,231 +/- S.F. (5.262AC <br />APPROXIMATE LOCATION OF EXISTING UTILITIES ARE SHOWN ON THESE PLANS. CONTRACTOR TO <br />COORDINATE WITH PURVEYORS AND USE EXTREME CAUTION WHEN EXCAVATING ON -SITE, UNTIL <br />EXISTING A S NG GAS AND POWER SERVICE LOCATIONS ARE CONFIRMED. CONTRACTOR TO ORDER <br />INDEPENDENT UTILITY LOCATES (INCLUDING GAS AND POWER) FOR THE FULL SCOPE OF WORK <br />PRIOR TO CONSTRUCTION OR ANY GROUND DISTURBING ACTIVITIES. <br />NOTE:HORIZONTAL CONTROL <br />CONTRACTOR SHALL HAVE ALL PROPERTY LINES, CURB, SIDEWALK, STRUCTURES, CONCRETE PADS <br />AND ANY OTHER ABOVE GROUND PERMANENT STRUCTURE DEPICTED ON THESE PLANS STAKED FOR <br />CONSTRUCTION BY A LICENSED SURVEYOR. OR. LICENSED SURVEYOR SHALL STAKE ALL ITEMS USING <br />COORDINATE GEOMETRY (RECTIFIED TO SITE CONTROL) CONTAINED IN CAD DRAWING FILES <br />PROVIDED BY BARGHAUSEN CONSULTING ENGINEERS, INC. IT IS THE CONTRACTOR'S <br />RESPONSIBILITY TO RETRIEVE LATEST CAD FILES FROM BARGHAUSEN CONSULTING ENGINEERS INC., <br />REFLECTING ANY ISSUED PLAN REVISIONS. BARGHAUSEN CONSULTING ENGINEERS SMALL <br />IMMEDIATELY BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH <br />OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE <br />UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS <br />SHALL INCLUDE CALLING UTILITY LOCATE 0 811 AND THEN POTHOLING ALL OF THE EXISTING <br />UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT <br />CONFLICTS EXIST, LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON <br />THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION, IF CONFLICTS SHOULD <br />OCCUR, THE CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE <br />ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. <br />Ip9N I <br />COVER SHEET <br />FLOOD PLAIN INFORMATION <br />SITE LIES WITHIN "FLOOD ZONE X" PER FEMA FIRM MAP ZONE <br />OF MINIMAL FLOODING IN CITY •_ EVERETT <br />EFFECTIVE5306IC103OG WITH DATE OF JUNE 19, i <br />20. <br />PROPOSED CITY OF <br />EVERETT WATER EASEMENT <br />UTILITY EASEMENT <br />NO. 20081 1250386 <br />LEOEND <br />EXISTING <br />PROPOSED <br />EXISTING <br />PROPOSED <br />NOTE.PROPERTY PROTECTION <br />CURB AND GUTTED <br />STORM LINE <br />SD <br />THE CONTRACTOR SHALL PROTECT AND PRESERVE FROM DAMAGES INTERFERENCE <br />BARRIER CURB <br />CATCH BASIN <br />TYPE 1 <br />AND DESTRUCTION ALL PRIVATE AND PUBLIC PROPERTY ON OR IN THE VICINITY <br />OF THE <br />CONCRETE <br />� � ` <br />� -� � <br />CATCH BASIN <br />_ <br />WORK, IF SUCH PROPERTY IS DAMAGED OR DESTROYED OR ITS USE <br />p <br />TYPE 2 <br />INTERFERED WITH BY THE CONTRACTOR OR HIS OR HER AGENTS, IT SHALL BE <br />.. . <br />SANITARY <br />T <br />RESTORED IMMEDIATELY TO ITS FARMER CONDITION B/ THE CONTRACTOR AT HIS <br />ASPHALT <br />, <br />,,. ...,,. <br />SEWER LINE <br />_.._._..._......_.........._.. <br />_....._._....__._... <br />OR HER EXPENSE AND SUCH INTERFERENCE TERMINATED. <br />SANITARY <br />PAINT STRIPING <br />SEWER <br />SURVEY MONUMENT NOTE, <br />MANHOLE <br />DIRECTIONAL ARROW <br />=- :. �...._.. <br />CLEANOUT (AS <br />NOTED) <br />CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR OBTAINING PERMITS FROM <br />THE WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES FOR REMOVING <br />SAWCUT <br />- - - - - - - - - - - _ <br />POWER <br />,I _ _.._, <br />PToH7 -_ <br />AND REPLACING ALL SURVEY MONUMENTATION THAT MAY BE AFFECTED BY <br />OVERHEAD <br />CONSTRUCTION ACTIVITY, PURSUANT TO WAG 332-120. APPLICATIONS MUST BE <br />BOLLARD <br />C; <br />POWER <br />--- .I.> J ____ <br />n(uG) <br />COMPLETED BY A REGISTERED LAND SURVEYOR. APPLICATIONS FOR PERMITS <br />UNDERGROUND <br />TO REMOVE MONUMENTS MAY BE OBTAINED FROM THE WASHINGTON STATE <br />SIGN <br />POWER METER <br />DEPARTMENT OF NATURAL RESOURCES, OR BY CONTACTING THEIR OFFICE BY <br />TELEPHONE AT (206) 902-1 190e <br />BUILDING LINE <br />;�' r:_ .. w� <br />UTILITY POLE <br />WASHINGTON STATE DEPARTMENT DE NATURAL RESOURCES <br />CONTOUR <br />mm 4 v2 <br />e432- - �" e <br />JUNCTION BOX <br />1,2,3) <br />PUBLIC LAND SURVEY OFFICE <br />(TYKE <br />1111 WASHINGTON STREET S.E. <br />WATER TINE <br />LUMINAIRE <br />P.O. BOX 47060 <br />OLYMPIA WASHINGTON 98504-7060 <br />FIRE HYDRANT <br />Ci <br />YARD LIGHT <br />UPON COMPLETION OF CONSTRUCTION, RUCTION, ALL MONUMENTS DISPLACED, REMOVED, <br />WATER METER <br />ffl <br />0 <br />TELEPHONE <br />T <br />OR DESTROYED SHALL BE REPLACED BY A REGISTERED LAND SURVEYOR, AT <br />THE COST AND AT THE DIRECTION OF THE CONTRACTOR, PURSUANT TO THESE <br />WATER VALVE <br />� <br />GAS <br />REGULATIONS. THE APPROPRIATE FORMS FOR REPLACEMENT OF SAID <br />FIRE DEPARTMENT CONN. <br />OAS METED <br />EN93 <br />MONUMENTATION SHALL ALSO BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />POST INDICATOR VALVE <br />#,p <br />�,�., <br />CAS VALVE <br />g. <br />All . -,I O� III, <br />t• _ATSEN CONSULTING ENGINEERS, INC, <br />18215 72ND AVE, SOUTH <br />KENT, WA ;0 <br />TEL: (425) 251-6222 <br />CONTACT: <br />� i' ,NI lit' ENGINEER <br />44TH SE SE <br />a � <br />r <br />R <br />CIVIL <br />C 1.0 m COVER SHEET <br />C 1.1 e LIMITED TOPOGRAPHIC SURVEY <br />C2.0 - DEMOLITION PLAN <br />C2.1 e TESL PLAN <br />C2.2 m TESL DETAILS <br />C3.0 m SITE PLAN <br />C3.1 e HORIZONTAL CONTROL PLAN <br />C4.0 - GRADING PLAN <br />C4.1 - GRADING DETAIL AND NOTES <br />C5.0 e DRAINAGE PLAN <br />C5.1 - DRAINAGE DETAILS <br />C6.0 e UTILITY PLAN <br />C6.1 - UTILITY DETAILS <br />C6.2 e UTILITY DETAILS <br />C7.0 a CONSTRUCTION DETAILS <br />C7.1 - CONSTRUCTION DETAILS <br />LANDSCAPE <br />L1 e PLANTING AND IRRIGATION SET <br />L2 - PLANTING AND IRRIGATION <br />G ON <br />SET <br />L3 - PLANTING AND IRRIGATION SET <br />Know whaftbelow. <br />Call before you di <br />Dial <br />Permit 4: <br />PW2111-007 5", / <br />Site Address: <br />4919 EVERGREEN WAY <br />Owner: <br />Tenant: <br />CLAREMONT VILLAGE STATION LLC <br />QFC - FUELING STATION <br />App, Date: <br />11/3/2021 <br />Proposed Use: <br />NEW COMMERCIAL <br />Description: <br />SITEWORK FOR NEW QFC FUELING Z <br />STATION <br />Reviewed By: <br />Date: -- <br />-Off ice Set <br />Job Site Set Fire/Planning Set <br />cc <br />W <br />W <br />Cq <br />LO <br />cc <br />I <br />W <br />z <br />0 <br />LU <br />LL <br />LL <br />x <br />z <br />0 <br />V) <br />LJJ <br />4 <br />4Vq VO <br />a€�f 1 <br />N� <br />0 <br />Oro <br />LO <br />00 0 <br />10/15/21 <br />e <br />Project pie 20996 Store #00852 <br />[2 <br />Designed By, ADW <br />Drawn By. ADW <br />¢ <br />Checked By. CJR <br />Dote: 10-15-2021 <br />Scale. 1 °' 30' <br />a <br />Disk File: 20996-0.dwg <br />7,� <br />A��deT: <br />Address: <br />c� <br />4919 EVERGREEN WAY co <br />EVERETT, WA 9820.E00 <br />