My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4937 EVERGREEN WAY 2021 QFC FUELING STATION Plans 2023-02-27 (4)
>
Address Records
>
EVERGREEN WAY
>
4937
>
QFC FUELING STATION
>
Plans
>
4937 EVERGREEN WAY 2021 QFC FUELING STATION Plans 2023-02-27 (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2023 8:04:12 AM
Creation date
2/23/2023 1:15:48 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
4937
Tenant Name
QFC FUELING STATION
Permit
PW2111-007
Year
2021
Notes
SITEWORK FOR NEW QFC FUELING STATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAX RAKE, 1/4" PER FT <br />FROM GROUND LEVEL <br />TRAFFIC SAFETY <br />FEATURE BREAK -OFF <br />FLANGE, BREAK OFF <br />NUTS AND BOLTS <br />1/2 CU YD WASHED ROCK <br />1-1/2" DRAIN ROCK <br />RETAINER <br />GLANDS - <br />12" x 12" x 4" <br />CONC BLOCK <br />UNDISTURBED EARTH <br />SCALE: NITS <br />GATE VALVE <br />(MJ x FL) <br />Y,r <br />DUCTILE IRON TEE <br />(MJxMJxFL) OR <br />TAPPING TEE (FL) <br />PARTS <br />A, HYDRANTS AND ALL MATERIALS SHALL CONFORM TO <br />AWWA STANDARDS AND SHALL BE OF STANDARD <br />MANUFACTURE (MUELLER SUPER CENTURION 250, <br />WATEROUS PACER #WB67, OR CITY APPROVED <br />EQUAL). <br />B. 5-1/4" VALVE MINIMUM. <br />C. 1-1/4" OPERATING NUT AND CAP NUT FOR 2-1/2" <br />PORTS. <br />D. NATIONAL STANDARD THREAD ON 2-1/2" PORTS. <br />E. 5" STORZ FITTING WITH NATIONAL STANDARD THREAD <br />ON THE 4-1/2" PORT. <br />F. IF HYDRANT RISES THROUGH CONCRETE, USE <br />EXPANSION STRIP AROUND HYDRANT BARREL, PER STD <br />PLAN 509. IN ADDITION, INSTALLATION OF THE <br />HYDRANT ON PRIVATE PROPERTY SHALL EQUAL OR <br />EXCEED THE STANDARDS FOR INSTALLATION OF <br />PUBLIC FIRE HYDRANTS IN THE CITY OF EVERETT. <br />G. PROVIDE FOR VEHICULAR TRAFFIC PROTECTION WHEN <br />NECESSARY PER STANDARD DRAWING 508. <br />H. STEAMER PORT TO BE FACING STREET OR ROADWAY <br />FOR FIRE ENGINE ACCESS. <br />1, BREAK -OFF FLANGE TO BE 2"-4" ABOVE GROUND <br />LEVEL. <br />J, INSTALL CONCRETE PAD AROUND HYDRANT IN <br />UNPAVED, SOD AND ASPHALT AREAS PER STANDARD <br />DRAWING 508. <br />K. HYDRANT CONNECTION PIPE TO BE DUCTILE IRON <br />CLASS 52, ANY INTERMEDIATE JOINTS TO BE MJ WITH <br />RETAINER GLANDS, OR FIELD LOCK GASKETS. <br />0 <br />L. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS <br />p <br />OF HIGH GLOSS CATERPILLAR YELLOW, LUXLITE <br />46100-516 OR "RUST-OLEUM" #7448 OR APPROVED <br />EQUAL. THE PORT CAPS WILL BE PAINTED BLACK. <br />M. PROVIDE FOR A MINIMUM OF T CLEAR ZONE AROUND <br />HYDRANT. <br />2 <br />CITY OF EVERETT <br />8 <br />.; <br />PUBLIC ART r <br />: <br />Erg';+er SectWn P,"anager FD P'a^axr 02.n ¢q Cv tt,S See <br />qM <br />RYAN SASS R H£FT! PAUL UVILHEL 1 WRt3 �.�'18 <br />Le <br />FIRE HYDRANT <br />Wa <br />INSTALLATION507 <br />n <br />NOTES <br />A. ROMAC, FORD, OR MUELLER SERVICE SADDLE WITH C.C. THREAD TO BE USED ON ALL MAINS 4" DIA. AND <br />LARGER. ALL NEW TAPS ON EXISTING WATER MAINS SHALL BE DONE BY THE CITY OF EVERETT UTILITIES <br />DEPARTMENT AT THE DEVELOPERS OR CONTRACTORS EXPENSE <br />B. CORPORATION STOP: <br />3/4J" OR 1" - FORD FB600, OR CITY APPROVED EQUAL <br />C. FORD SERIES LAO-2-33S NL FOR 3/4" OR LA02-445-NL FOR 1" BEND FITTING (1/8 OR 1/4) FOR FLARE x FLARE <br />COPPER. PHYSICAL BENDS IN POLYETHYLENE PIPE ARE NOT ALLOWED. USE APPROPRIATE 1/4 OR 1/8 BENDS PER <br />NOTE B ABOVE. <br />D. USE MUELLER H-15073 N INSTA-TITS FITTING OR CITY APPROVED EQUAL FOR IPS-PE PLASTIC PIPE X FEMALE <br />COPPER FLARE THREAD. <br />E. RESIDENTIAL SERVICE: <br />1. PROVIDE 3/4" OR 1" POLYETHYLENE TUBING MEETING THE FOLLOWING REQUIREMENTS: <br />a. AWWA C901. <br />b. ASTM D2239, SIDR 7, FOR ID IRON PIPE SIZE (IPS). <br />c. ASTM 3350 - PE3608 OR PE4710. <br />2. PROVIDE A #10 AWG, SINGLE STRAND COPPER WIRE WITH BLUE TYPE OF OR USE COATING SUITABLE FOR <br />DIRECT BURY. <br />a. WRAP WIRE AROUND TUBING, ONE WRAP PER FT, ITS ENTIRE LENGTH. <br />b. SECURE ONE END AROUND THE SADDLE BOLT BETWEEN TWO NUTS AND EXPOSE A MINIMUM OF 18" OF THE <br />OTHER END IN THE METER BOX. <br />F. NON-RESIDENTIAL SERVICE: <br />1. PROVIDE 3/4" OR 1" TYPE K COPPER TUBING MEETING ASTM B88, ANSI/NSF 61 & APPLICABLE IAPMO <br />STANDARDS. <br />G. USE 1/4 OR 1/8 BEND BRASS ST BEND WITH MUELLER H-15426 N INSTA-TITS FITTING OR CITY APPROVED EQUAL <br />FOR IPS-PE PLASTIC PIPE X MALE IRON PIPE THREAD. <br />H. 3/4" METER SETTER SHALL BE "A.Y. MCDONALD" 62-212WWDD33-15 OR APPROVED EQUAL, <br />1" METER SETTER SHALL BE "A.Y. MCDONALD" 62-415WWDD44-15 OR CITY APPROVED EQUAL. <br />1. METERS SHALL BE SUPPLIED AND INSTALLED BY CITY UTILITIES DEPARTMENT AT THE DEVELOPERS OR <br />CONTRACTOR EXPENSE. <br />J. PROVIDE METER BOX BODY MANUFACTURED BY "RAVEN PRODUCTS, FOR A 3/4" USE MODEL RMB-11-18-12, <br />FOR A 1" USE MODEL RMB-15-27-12", MOUSEHOLES CUT, WITH AASTHO H-20 RATED DI FLUSH SOLID COVER <br />LID OR EQUAL, <br />K. PLACE SAWDUST IN METER BOX AROUND PIPE TO TOP OF METER TO PREVENT FREEZING. <br />ry1" C`Ptt i fi t'tA" "ttl fGH <br />41/2" DIA x 1/4" MIN <br />THICKNESS STEEL <br />(1/8" MIN WALL THICKNESS) <br />VALVEI IN NUT EXTENSION <br />NOTES <br />1. VALVE OPERATING NUT EXTENSIONS ARE REQUIRED <br />WHEN THE VALVE NUT IS MORE THAN THREE (3) <br />FEET BELOW FINISHED GRADE. EXTENSIONS ARE TO <br />BE A MINIMUM OF ONE (1) FOOT LONG. ONLY ONE <br />EXTENSION WILL BE ALLOWED PER VALVE, <br />2. ALL VALVE OPERATING NUT EXTENSIONS ARE TO BE <br />MADE OF STEEL, SIZED AS NOTED, AND PAINTED <br />WITH TWO (2) COATS OF METAL PAIN`I-, <br />3, VALVE BOXES IN PAVED AREAS SHALL BE CAST IRON, <br />TWO PIECE UNITS, EAST JORDAN 85551. " TOP, 24t' <br />BOTTOM AND EAST JORDAN 6800 HEAVY DUTY LID <br />W/ "WATER" ON LID. IN GRASS, NON -PAVED OR <br />NON -TRAFFIC AREAS USE OF PLASTIC VALVE BOXES, <br />WITH CAST IRON LID AS MANUFACTURED BY <br />HANDLEY INDUSTRIES ARE ACCEPTABLE; <br />4. USE OF PLASTIC VALVE BOX EXTENSIONS, AS <br />MANUFACTURED BY HANDLEY INDUSTRIES ARE <br />ACCEPTABLE. <br />CITY OF EVERETT <br />PUBLIC WORKS DEPARTMENT <br />RYAN SASS F AE'H "t �PAUL WILHELI`J4 VuTi� '� /'. {j/ j`q1 y <br />nne <br />Cj <br />C <br />q) <br />C:) 0 <br />10/15/21 <br />0 <br />Co <br />6 <br />Z <br />Project . 20996 Store #00852 <br />Designed By. ADS! <br />Drawn By. ADW <br />_ <br />Checked By. CJR <br />N <br />Dates 10-15-2021CD <br />- <br />Gcole: 9 `" 10' <br />LO <br />Disk File: 20996-U.dwg <br />Model: <br />Address: <br />d"' IlgillgmL <br />aae ,• s i' <br />UTILITY DETAILS <br />
The URL can be used to link to this page
Your browser does not support the video tag.