Laserfiche WebLink
MAX RAKE, 1/4" PER FT <br />FROM GROUND LEVEL <br />TRAFFIC SAFETY <br />FEATURE BREAK -OFF <br />FLANGE, BREAK OFF <br />NUTS AND BOLTS <br />1/2 CU YD WASHED ROCK <br />1-1/2" DRAIN ROCK <br />RETAINER <br />GLANDS - <br />12" x 12" x 4" <br />CONC BLOCK <br />UNDISTURBED EARTH <br />SCALE: NITS <br />GATE VALVE <br />(MJ x FL) <br />Y,r <br />DUCTILE IRON TEE <br />(MJxMJxFL) OR <br />TAPPING TEE (FL) <br />PARTS <br />A, HYDRANTS AND ALL MATERIALS SHALL CONFORM TO <br />AWWA STANDARDS AND SHALL BE OF STANDARD <br />MANUFACTURE (MUELLER SUPER CENTURION 250, <br />WATEROUS PACER #WB67, OR CITY APPROVED <br />EQUAL). <br />B. 5-1/4" VALVE MINIMUM. <br />C. 1-1/4" OPERATING NUT AND CAP NUT FOR 2-1/2" <br />PORTS. <br />D. NATIONAL STANDARD THREAD ON 2-1/2" PORTS. <br />E. 5" STORZ FITTING WITH NATIONAL STANDARD THREAD <br />ON THE 4-1/2" PORT. <br />F. IF HYDRANT RISES THROUGH CONCRETE, USE <br />EXPANSION STRIP AROUND HYDRANT BARREL, PER STD <br />PLAN 509. IN ADDITION, INSTALLATION OF THE <br />HYDRANT ON PRIVATE PROPERTY SHALL EQUAL OR <br />EXCEED THE STANDARDS FOR INSTALLATION OF <br />PUBLIC FIRE HYDRANTS IN THE CITY OF EVERETT. <br />G. PROVIDE FOR VEHICULAR TRAFFIC PROTECTION WHEN <br />NECESSARY PER STANDARD DRAWING 508. <br />H. STEAMER PORT TO BE FACING STREET OR ROADWAY <br />FOR FIRE ENGINE ACCESS. <br />1, BREAK -OFF FLANGE TO BE 2"-4" ABOVE GROUND <br />LEVEL. <br />J, INSTALL CONCRETE PAD AROUND HYDRANT IN <br />UNPAVED, SOD AND ASPHALT AREAS PER STANDARD <br />DRAWING 508. <br />K. HYDRANT CONNECTION PIPE TO BE DUCTILE IRON <br />CLASS 52, ANY INTERMEDIATE JOINTS TO BE MJ WITH <br />RETAINER GLANDS, OR FIELD LOCK GASKETS. <br />0 <br />L. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS <br />p <br />OF HIGH GLOSS CATERPILLAR YELLOW, LUXLITE <br />46100-516 OR "RUST-OLEUM" #7448 OR APPROVED <br />EQUAL. THE PORT CAPS WILL BE PAINTED BLACK. <br />M. PROVIDE FOR A MINIMUM OF T CLEAR ZONE AROUND <br />HYDRANT. <br />2 <br />CITY OF EVERETT <br />8 <br />.; <br />PUBLIC ART r <br />: <br />Erg';+er SectWn P,"anager FD P'a^axr 02.n ¢q Cv tt,S See <br />qM <br />RYAN SASS R H£FT! PAUL UVILHEL 1 WRt3 �.�'18 <br />Le <br />FIRE HYDRANT <br />Wa <br />INSTALLATION507 <br />n <br />NOTES <br />A. ROMAC, FORD, OR MUELLER SERVICE SADDLE WITH C.C. THREAD TO BE USED ON ALL MAINS 4" DIA. AND <br />LARGER. ALL NEW TAPS ON EXISTING WATER MAINS SHALL BE DONE BY THE CITY OF EVERETT UTILITIES <br />DEPARTMENT AT THE DEVELOPERS OR CONTRACTORS EXPENSE <br />B. CORPORATION STOP: <br />3/4J" OR 1" - FORD FB600, OR CITY APPROVED EQUAL <br />C. FORD SERIES LAO-2-33S NL FOR 3/4" OR LA02-445-NL FOR 1" BEND FITTING (1/8 OR 1/4) FOR FLARE x FLARE <br />COPPER. PHYSICAL BENDS IN POLYETHYLENE PIPE ARE NOT ALLOWED. USE APPROPRIATE 1/4 OR 1/8 BENDS PER <br />NOTE B ABOVE. <br />D. USE MUELLER H-15073 N INSTA-TITS FITTING OR CITY APPROVED EQUAL FOR IPS-PE PLASTIC PIPE X FEMALE <br />COPPER FLARE THREAD. <br />E. RESIDENTIAL SERVICE: <br />1. PROVIDE 3/4" OR 1" POLYETHYLENE TUBING MEETING THE FOLLOWING REQUIREMENTS: <br />a. AWWA C901. <br />b. ASTM D2239, SIDR 7, FOR ID IRON PIPE SIZE (IPS). <br />c. ASTM 3350 - PE3608 OR PE4710. <br />2. PROVIDE A #10 AWG, SINGLE STRAND COPPER WIRE WITH BLUE TYPE OF OR USE COATING SUITABLE FOR <br />DIRECT BURY. <br />a. WRAP WIRE AROUND TUBING, ONE WRAP PER FT, ITS ENTIRE LENGTH. <br />b. SECURE ONE END AROUND THE SADDLE BOLT BETWEEN TWO NUTS AND EXPOSE A MINIMUM OF 18" OF THE <br />OTHER END IN THE METER BOX. <br />F. NON-RESIDENTIAL SERVICE: <br />1. PROVIDE 3/4" OR 1" TYPE K COPPER TUBING MEETING ASTM B88, ANSI/NSF 61 & APPLICABLE IAPMO <br />STANDARDS. <br />G. USE 1/4 OR 1/8 BEND BRASS ST BEND WITH MUELLER H-15426 N INSTA-TITS FITTING OR CITY APPROVED EQUAL <br />FOR IPS-PE PLASTIC PIPE X MALE IRON PIPE THREAD. <br />H. 3/4" METER SETTER SHALL BE "A.Y. MCDONALD" 62-212WWDD33-15 OR APPROVED EQUAL, <br />1" METER SETTER SHALL BE "A.Y. MCDONALD" 62-415WWDD44-15 OR CITY APPROVED EQUAL. <br />1. METERS SHALL BE SUPPLIED AND INSTALLED BY CITY UTILITIES DEPARTMENT AT THE DEVELOPERS OR <br />CONTRACTOR EXPENSE. <br />J. PROVIDE METER BOX BODY MANUFACTURED BY "RAVEN PRODUCTS, FOR A 3/4" USE MODEL RMB-11-18-12, <br />FOR A 1" USE MODEL RMB-15-27-12", MOUSEHOLES CUT, WITH AASTHO H-20 RATED DI FLUSH SOLID COVER <br />LID OR EQUAL, <br />K. PLACE SAWDUST IN METER BOX AROUND PIPE TO TOP OF METER TO PREVENT FREEZING. <br />ry1" C`Ptt i fi t'tA" "ttl fGH <br />41/2" DIA x 1/4" MIN <br />THICKNESS STEEL <br />(1/8" MIN WALL THICKNESS) <br />VALVEI IN NUT EXTENSION <br />NOTES <br />1. VALVE OPERATING NUT EXTENSIONS ARE REQUIRED <br />WHEN THE VALVE NUT IS MORE THAN THREE (3) <br />FEET BELOW FINISHED GRADE. EXTENSIONS ARE TO <br />BE A MINIMUM OF ONE (1) FOOT LONG. ONLY ONE <br />EXTENSION WILL BE ALLOWED PER VALVE, <br />2. ALL VALVE OPERATING NUT EXTENSIONS ARE TO BE <br />MADE OF STEEL, SIZED AS NOTED, AND PAINTED <br />WITH TWO (2) COATS OF METAL PAIN`I-, <br />3, VALVE BOXES IN PAVED AREAS SHALL BE CAST IRON, <br />TWO PIECE UNITS, EAST JORDAN 85551. " TOP, 24t' <br />BOTTOM AND EAST JORDAN 6800 HEAVY DUTY LID <br />W/ "WATER" ON LID. IN GRASS, NON -PAVED OR <br />NON -TRAFFIC AREAS USE OF PLASTIC VALVE BOXES, <br />WITH CAST IRON LID AS MANUFACTURED BY <br />HANDLEY INDUSTRIES ARE ACCEPTABLE; <br />4. USE OF PLASTIC VALVE BOX EXTENSIONS, AS <br />MANUFACTURED BY HANDLEY INDUSTRIES ARE <br />ACCEPTABLE. <br />CITY OF EVERETT <br />PUBLIC WORKS DEPARTMENT <br />RYAN SASS F AE'H "t �PAUL WILHELI`J4 VuTi� '� /'. {j/ j`q1 y <br />nne <br />Cj <br />C <br />q) <br />C:) 0 <br />10/15/21 <br />0 <br />Co <br />6 <br />Z <br />Project . 20996 Store #00852 <br />Designed By. ADS! <br />Drawn By. ADW <br />_ <br />Checked By. CJR <br />N <br />Dates 10-15-2021CD <br />- <br />Gcole: 9 `" 10' <br />LO <br />Disk File: 20996-U.dwg <br />Model: <br />Address: <br />d"' IlgillgmL <br />aae ,• s i' <br />UTILITY DETAILS <br />