Laserfiche WebLink
-4401 <br />PER PLAN <br />4? oePER <br />PLAN <br />10 Or <br />1-1/2" MIN. GATE FRAME <br />1-1/2" MIN. GATE FRAME <br />HEAVY DUTY HINGE <br />I <br />j <br />I <br />j <br />I CHAIN LINK MESH WITH <br />HEAVY DUTY HINGE <br />I; <br />i <br />- -- <br />I <br />I' <br />PRIVACY SLATS <br />r <br />z <br />_ <br />1-1 2» MIN. BRACE RAIL <br />I <br />� <br />II <br />BAR TYP. <br />x— <br />1-1/27 MIN. BRACE RAIL <br />f� <br />I ,�I <br />` <br />IE <br />1I <br />II <br />, <br />d <br />I <br />I <br />II <br />CHAIN <br />LINK MESH <br />WITH <br />c— <br />Wn <br />x <br />..II <br />PRIVACY <br />SLATS <br />GALV. TERMINAL POST AT — <br />f 7 <br />l <br />I' <br />f <br />II <br />II <br />II�LTERMINAL <br />`` <br />I <br />, <br />� <br />GALV. POST A T ENDS , <br />vJv <br />� <br />I <br />1 <br />f <br />I f <br />�- <br />ENDS, AND PULLS. 2 7 8 <br />I <br />� <br />Q <br />� <br />AND PULLS. 2 7 8 O.D. SCH. <br />i � <br />, <br />a <br />O.D., SCH. 40 <br />GATE LATCH W MUSHROOM <br />/ <br />�— <br />40 <br />I, <br />11II <br />I <br />1 <br />L� <br />i <br />�I <br />GATE <br />LATCH W/ <br />MUSHROOM <br />o <br />�- <br />1 2 MIN. DIAGONAL ROD <br />TYPE CATCH AND PADLOCKING <br />1 2 MIN. DIAGONAL ROD <br />;- : <br />I; <br />TYPE <br />CATCH AND <br />PADLOCKING <br />- <br />WITH STEEL TURNBUCKLE <br />EYE <br />WITH STEEL TURNBUCKLE <br />,; ., <br />EYE <br />_CD <br />All <br />AI <br />J <br />I <br />TL <br />FINISH GRADE <br />Fu <br />FINISH GRADE <br />2500 PSI CONCRETE <br />2500 PSI CONCRETE <br />FOOTING <br />z <br />FOOTING ` <br />z <br />0ry <br />HALF—MOON GATE KEEPER <br />FOR PLUNGER ROD <br />u <br />NOTES: <br />11 —O't <br />I I <br />NOTES: <br />— ALL STEEL AND/OR MALLEABLE IRON PARTS, ACCESSORIES, AND <br />FASTENERS SHALL BE HOT DIPPED GALVANIZED FOR RUST PROOFING. <br />— ALL STEEL AND/OR MALLEABLE IRON PARTS, ACCESSORIES, AND FASTENERS <br />SHALL <br />BE HOT DIPPED <br />GALVANIZED FOR <br />RUST PROOFING. <br />— GATE LOCKS MUST BE ACCESSIBLE FROM INSIDE OF FENCE PER <br />FIRE AND SAFETY REQUIREMENTS <br />— GATE LOCKS MUST BE ACCESSIBLE FROM INSIDE OF FENCE PER FIRE AND <br />SAFETY <br />REQUIREMENTS <br />CHAIN LINK ACCESS GATE1/2":Nfr.SO" <br />SCE: <br />7 <br />DOUBLE SWING CHAIN LINK ACCESS GATE <br />SCALE: <br />1 <br />,,�,��-o» <br />H <br />Raycap <br />INSTALLATION NOTES FOR POST —INSTALLED ANCHORS: <br />Q <br />MANUFACTURER: CHARLES <br />MANUFACTURER: RAYCAP <br />w <br />1. CENTER OF ANCHORS TO HAVE MINIMUM OF 120 DISTANCE TO <br />J <br />MODEL: CUBE RL 1000 <br />MODEL: 100-3R-1 U <br />CONCRETE EDGES/SEAMS AND MOM EXISTING OR <br />•' <br />':� <br />�'•.: •. <br />ABANDONED ANCHORS. <br />A <br />• •:.� <br />2. CONTRACTOR SHALL, RED VERIFY CONCRETE THICKNESS PER <br />1' <br />'.: ' <br />� � <br />FOR 19 & <br />� � <br />23 <br />TABLE BELOW.� <br />w <br />„• <br />•' � ••,• <br />= • <br />DIMENSIONS: 26.3"X 22.1 "X 20.0" <br />DIMENSIONS: <br />RACK <br />3. CONTRACTOR SHALL SCAN FOR AND LOCATE EXISTING REBAR <br />z <br />. <br />'• �' : •• <br />• •• <br />o <br />_ <br />0 <br />_ <br />BEFORE DRILLING. DO NOT CUT OF DAMAGE FOUNDATION <br />:• .. <br />REBAR, IF REBAR IS ENCOUNTERED DURING DRILLING <br />�' <br />!• <br />OPERATIONS, NOTIFY FOR IMMEDIATELY. MINOR ADJUSTMENT TO <br />ANCHOR LOCATION MAY BE REQUIRED. <br />�v <br />r� <br />4. CONCENTRATOR SMALL USE EQUIPMENT MANUFACTURER'S <br />��� � � , <br />No .......�q.... .:: -... ```a'° <br />Wdy ��,��qa,k I ,�,�� �� � ,A <br />��� �,, gig:, �.. �, ,�;� � a.,-s�.n �.. �.�.r� �. � . � �x� .�,�,� �.�3� <br />310" <br />�,��I �nr <br />E .- <br />� I = <br />BOLTING LAYOUT AND SPECIFICATIONS. SPECIAL INSPECTIO NS <br />REQUIRED DURING INSTALLATION OF ANCHORS. <br />INSTALLATION <br />DETAILS FOR POST INSTALLED ANCHORS <br />ANCHORTYPES <br />HILTI K B TZ2 STA I N LESS STEE L <br />LENGTH OF ANCHOR, LAN CH (in) <br />4.25 <br />DIAMETER OF ANCHOR, DA (in) <br />0.625 <br />MINIMUM THICKNESS OF FASTENED STEEL MATERIAL, TMIN (in) <br />0.118 <br />MINIMUM EFFECTIVE EMBEDMENT, HEF (in) <br />2.75 <br />MINIMUM NOMINAL EMBEDMENT, HNOM (in) <br />3.25 <br />MINIMUM DRILL HOLE DEPTH, HO (in) <br />3.75 <br />MINIMUM CONCRETE SLAB THICKNESS, TCONC (in) <br />5 <br />REQUIRED INSTALLATION TORQUE <br />60 FT -LB <br />r <br />*NOTIFY OER IF MATERIAL THICKNESS DOES NOT MEET MINIMUM VALUES SPECIRED <br />.om� 4- uuf <br />**HAMMER DRILL HOLE IN CONCRETE BASE MATERIAL. AND CLEAN HOLD PER <br />MANUFACTURE'S SPECIFICATIONS. <br />CUBE R L 1000 SCALE: 11 RAYCA P 10 0-3 R-1 U SCALE: 18 ANCHORAGE SCALE: 2 <br />N.T.S. N.T.S. N.T.S. <br />Part # <br />.,, ,6,HDepth <br />MANUFACTURER: PURCELL MANUFACTURER: PURCELL <br />G``.` MODEL: 2000005434 MODEL: 2000005433 <br />'` ° <br />DIMENSIONS: 30.0" x 32.0" x 60" DIMENSIONS: 30.0" x 48.0" x 72.0" <br />WEIGHT: 350 LBS (EMPTY) WEIGHT: 430 LBS (EMPTY) <br />�-% 2„ 11 .0 3,000 LBS (MAX LOADED) ±650 LBS (FULLY LOADED) <br />, ATTACHMENT: ATTACHMENT: <br />j -1_' <br />PER MANUFACTURERS SPECS. PER MANUFACTURERS SPECS. <br />(4) -48V 190AHR BATTERY STRINGS <br />(4) BATTERIES PER STRING 600A DC POWER SYSTEM <br />8 RU ALPHA CXPS E 8 <br />U L 508A STANDARDS 625 A, 10 48 V 3 KW 62 5 A <br />• DESIGNED TO STANDARD GR-487RECTIFIER POSITIONS <br />, <br />ISSUE 5, HYDROGEN OUT GASSING, CXRF HP 3 KW 62 5 A RECTIFIERS <br />>96.5% EFFICIENCY <br />PROPOSED ICE BRIDGE EXTERNAL PAINT, ZONE 4 SEISMIC 3 RECTIFIERS INCLUDED <br />SUPPORT BRACKET & CHANNEL LOADING, SAFETY, THERMAL, <br />INTRUSION AND <br />IMPACT 48 LOAD DISTRIBUTION CB POSITIONS <br />o PLUG IN, BULLET STYLE CB 100A <br />I EXISTING POST PER PLAN CAPACITY PER POSITION <br />0 <br />UL/CSA/IEC 60950 1 <br />U L 508A STANDARDS <br />• DESIGNED TO STANDARD GR-487, <br />ISSUE 5, HYDROGEN OUT GASSING, <br />EXTERNAL PAINT, ZONE 4 SEISMIC <br />LOADING, SAFETY, THERMAL, <br />INTRUSION AND o <br />BOT. OF POST IMPACT <br />ED SCALE: 12 ICE BRIDGE W/ EXIST. POST SCALE: 9 PURCELL 600A BATTERY CABINS SCALE: 6 PURCELL HPL3 600A DC CABINET SCALE: 3 <br />NOT U S N.T.S. N.T.S. N.T.S. <br />Stick Together g <br />1855 GATEWAY BLVD. SUITE 900 <br />CONCORD, CA 94520 <br />FjNWLC, I IINI-UKMHI IUIN: <br />CROWN BU- 825709 <br />SITE NUMBER: <br />SE01685B <br />SITE NAME: <br />MASONIC CENTER <br />220 OLYMPIC BLDV. EVERETT, WA 98203 <br />CURRENT ISSUE DATE: <br />04/05/22 <br />:ISSUED FOR: <br />CONSTRUCTION <br />-REV.: DATE: D�c�plDTlnr.l• Rv•- <br />A <br />10/06/2021 <br />90�7, <br />0 <br />03/21/2022 <br />100' <br />04/05/22 <br />100, <br />PE <br />-PLANS PREPARED BY: <br />2500 Red Hill Ave., #220, Santa Ana, CA 92705 <br />Office: (949) 202-4913 Fax: (818) 840-0708 <br />-CONSULTANT: <br />2500 Red Hill Ave., #220, Santa Ana, CA 92705 <br />Office: (949) 202-4913 Fax: (818) 840-0708 <br />DRAWN BY: CHK.: APV.: <br />PLR AM AM <br />FLICENSURE: <br />SHEET TITLE: <br />DETAILS AND <br />SPECIFICATIONS <br />1—CUE= 1\11 IAAQED• <br />D-2 <br />SE01685B <br />