DESIGN CRITERIA <br />CODE: INTERNATIONAL BUILDING CODE - <br />2015 EDITION <br />ROOF: <br />25 PSF <br />FLOORS: <br />OFFICE <br />50 PSF <br />CORRIDORS/EXI T S <br />100 PSF <br />PUBLIC AREAS <br />100 PSF <br />DECK <br />75 ESE <br />!HIND: <br />BASIC WIND SPEED <br />110 MPH <br />EXPOSURE <br />C <br />TOPOGRAPHICAL FACTOR, Kzi <br />1.0 <br />SEISMIC: <br />SPECTRAL RESPONSE ACCELERATION, <br />Ss <br />1.281 <br />SPECTRAL RESPONSE ACCELERATION, <br />S1 <br />0.487 <br />SPECTRAL RESPONSE ACCELERATION, <br />Sds <br />0.854 <br />SPECTRAL RESPONSE ACCELERATION, <br />Sdi <br />0.491 <br />SOIL SITE CLASS. Fa <br />1.000 <br />SOIL SITE CLASS, Fv <br />1.513 <br />SEISMIC DESIGN CATEGORY <br />D <br />SEISMIC DESIGN (WOOD LEVELS): <br />RESPONSE MODIFICATION FACTOR, R 6.5 (BRG WALL/SHEATHED WALLS) <br />REDUNDANCY FACTOR 1.0 <br />GENERAL CONDITIONS <br />1. THE CONTRACTOR SHALL VERIFY AND REVIEW ALL ITEMS WITHIN THE DRAWINGS PRIOR <br />TO PROCEEDING WITH THE WORK. NOTIFY THE ENGINEER/ARCHITECT IMMEDIATELY WITH <br />ANY DISCREPANCIES. <br />2. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK, THE <br />CONSTRUCTION SHALL BE THE SAME AS FOR SIMILAR WORK. <br />J. DIMENSIONS ARE NOT TO BE SCALED FROM THE PLANS, SECTIONS, OR DETAILS WITHIN <br />THE DRAWINGS. <br />4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, <br />METHODS, TECHNIQUES, SEQUENCE, AND PROCEDURES, <br />5. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE REFERENCED <br />BUILDING AND ALL OTHER REGULATING AGENCIES EXERCISING AUTHORITY OVER ANY <br />PORTION OF THE WORK. <br />6. SPECIFIC NOTES AND DETAILS IN THE DRAWINGS SHAI L TAKE PRECEDENCE OVER <br />GENERAL NOTES AND SPECIFICATIONS. <br />7. NOTIFY THE ENGINEER OF ALL CHANGES MADE IN THE FIELD PRIOR TO INSTALLATION. <br />E OUNDA T ION <br />1. FOUNDATION DESIGN PARAMETERS ASSUMED BY OWNER: <br />A. IBC SOIL SITE CLASSIFICATION. ............. D <br />B. FOOTING BEARING PRESSURE ................ 1,500 PSF <br />C. LATERAL EARTH PRESSURE: <br />o ACTIVE ...... ............... __... ......... ........ 35 PCF <br />PASSIVE ..... -.....................................150 PCF <br />COEFFICIENT OF FRICTION..... ... ..... - 0. j5 <br />2. SUBGRADE PREPARATION, DRAINAGE PROVISIONS AND OTHER RELEVANT SOIL <br />CONSIDERATIONS ARE TO BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. <br />3, ALL FOUNDATIONS ARE TO BEAR ON COMPETENT NATIVE SOILS OR COMPACTED <br />STRUCTURAL FILL. STRUCTURAL FILL IS TO BE COMPACTED TO 957 DENSITY PER <br />ASTM D-1557. <br />CONCRETE <br />1, REFERENCE STANDARDS: ACI-301 AND ACI-318, <br />2. MINIMUM CONCRETE STRENGTH AT 28 DAYS: 2,500 PSI (5% SACK MIX) <br />3. THE INA TER\EMEN T RATIO SHALL NOT EXCEED: 0.5 (BY WEIGHT) <br />4. AGGREGATE GRADING SHALL COMPLY WITH AASHTO #57 GRADATION OR BETTER. <br />PORTLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE II. <br />5. COMPLY WITH ACI-301 FOR MIXING. DO NOT EXCEED THE AMOUNT OF WATER <br />.SPECIFIED IN THE APPROVED MlIX. PROPORTIONS OF AGGREGATE TO CEMENT SHALL BE <br />SUCH AS TO PRODUCE A DENSE WORKABLE MIX WHICH CAN BE PLACED WITHOUT <br />SEGREGATION OR EXCESSIVE FREE SURFACE WATER. <br />6. COMPLY WITH ACI-301 FOR PLACEMENT. PROVIDE A 3/ INCH CHAMFER AT ALL <br />EXPOSED CONCRETE EDGES, UNLESS INDICATED OTHERWISE IN THE DRAWINGS. <br />7. MAXIMUM SLUMP TO BE 4" _+ 1", TYPICAL. DO NOT ADD WATER TO THE MIX TO <br />INCREASE SLUMP, MAXIMUM SLUMP MAY BE INCREASED BY 1" IF THE SLUMP IS <br />TESTED DIRECTLY FROM THE TRUCK PRIOR TO BEING PUMPED INTO PI ACE. <br />8, ACCELERATED SET OR HIGH EARLY STRENGTH MAY BE ACHIEVED BY USING APPROVED <br />ADMIXTURES. <br />9. COMPLY WITH ACI-505R FOR PLACEMENT IN HOT WEATHER AND ACI-306R FOR <br />PLACEMENT IN COLD WEATHER. <br />10, REFER TO ARCHITECTURAL DRAWINGS FOR CONCRETE FINISH, ALL EXPOSED CONCRETE <br />IS TO HAVE A CLASS A FINISH. <br />11, PROVIDE AIR ENTRAINMENT OF 5% ± 1,5% FOR ALL CONCRETE EXPOSED TO WEATHER. <br />REINFORCING STEEL <br />1. REFERENCE STANDARDS: ACI "DETAIL MANUAL" AND CRSI MANUAL OF STANDARD <br />PRAC TICS <br />2, MATERIALS: <br />A. REINFORCING STEEL: ASTM A615, GRADE 40 FOR #4 AND SMALLER <br />ASTM A615, GRADE 60 FOR #5 AND LARGER <br />B. WELDED WIRE REINFORCING: ASTM A82 AND A185, Fy = 75 KS[ <br />3, LAP CONTINUOUS REINFORCING BARS PER REQUIREMENTS LISTED BELOW, UNLESS <br />NOTED OTHERWISE. PROVIDE CORNER BARS OR HOOKS BARS (90 OR 180 DEGREE) AT <br />THE END OF ALL HORIZONTAL REINFORCEMENT IN WALLS. REFER TO NOTE 6 FOR <br />BEND REQUIREMENTS, <br />BAR SIZE <br />MIN, <br />LAP <br />LENGTH <br />#4 <br />2'- <br />6 <br />#5 <br />3'-0" <br />#6 <br />4'-6" <br />4. REINFORCEMENT COVER: <br />FOOTINGS 3 INCHES TO EARTH <br />2 INCHES TO FORMED SURFACE <br />SLABS 2 INCHES TO EARTH <br />FORMED SURFACE: <br />EXTERIOR <br />FACE 1% <br />INCHES, <br />#5 BAR AND SMALLER <br />2 <br />INCHES, <br />#6 BAR AND LARGER <br />INTERIOR <br />FACE 314 <br />INCHES <br />FOR SLABS AND WALLS <br />IY2 <br />INCHES <br />FOR BEAMS AND COLUMNS <br />5, REINFORCING STEEL A615 <br />MAY NOT BE <br />WELDED <br />TO OTHER STEEL ELEMENTS. (ACI <br />318-14 26.6.4.1) <br />6, REINFORCING STEEL BENDS <br />AND HOOKS <br />TO MEET <br />ACI REQUIREMENTS (PER 25.3.2). <br />O5 = BAR DIAMETER <br />1 MAX <br />6 <br />n rrnr-r <br />BAR <br />D <br />#3 <br />1y <br />4. <br />2 " <br />5 <br />2%" <br />#6 <br />x/ „ <br />- 5Y4 "_ <br />#8 <br />6„ <br />J. BEND DIAMETER FOR TIES AND STIRRUPS: <br />= 4*0 FOR #5 AND SMALLER <br />= 6*0 FOR #6 - #8 <br />8*0FOR #9-#11 <br />= 10*rA FOR #14 AND LARGER <br />L6OL <br />12D FOR #6 THRU #8 <br />FOR STIRRUPS & TIES <br />1 1 <br />4D or <br />212 MIN FOR REINF. BAPS <br />STRUCTURAL STEEL <br />o <br />T� <br />BAR <br />D <br />� 3 <br />--\4„ <br />#6 <br />4%„ <br />/ <br />1 <br />5/„ <br />MIN. BEND DIAMETER: <br />D = 6*0 FOR #8 AND SMALLER <br />D = 8*0 FOR #9 - #11 <br />D = 10*0 FOR #14 AND LARGER <br />1, REFERENCE STANDARDS: LATEST EDITION OF THE AISC "CODE OF STANDARD <br />PRACTICE FOR STEEL BUILDINGS AND BRIDGES". <br />2. MATERIALS: <br />BOL TS: <br />STEEL TO WOOD - ASTIM A307 <br />STEEL TO STEEL - ASTM A325 <br />STEEL TO CONCRETE - HEAVY HEX HEAD ASTM F1554 GR, 36 <br />WOOD TO CONCRETE - ASTM F1554 OR. 36 <br />W SHAPES: AS IM A992 (Fy = 50,000 PSI) <br />TUBE STEEL: SQ/RECT - ASTM A500-10, GRADE B (Fy = 46,000 PSI MIN) <br />ROUND ASTM A50010, GRADE B (Fy = 42,000 PSI MIN) <br />ALL OTHER STEEL: ASTM A36 (Fy - 36,000 PSI) <br />CONCRETE OR MASONRY ANCHORS <br />1, MECHANICAL ANCHORS ARE TO BE EITHER SIMPSON STRONG -BOLT 2 OR SIMPSON <br />TITER HD ANCHORS. ANCHOR SIZE AND EMBEDMENT IS AS SPECIFIED ON THE <br />DRAWINGS OR IN THE FIELD. <br />2 EPDXY FOR THREADED RODS OR REBAR INTO CONCRETE IS TO BE SIMPSON SET-3c, <br />EPDXY FOR THREADED RODS OR REBAR INTO SOLID MASONRY IS TO BE SIMPSON SET <br />ROD OR REBAR SIZE AND EMBEDMENT IS AS SPECIFIED ON THE DRAWINGS OR IN THE <br />FIELD. <br />DIMENSIONAL LUMBER <br />1. MEET THE REQUIREMENTS OF PS 20-70 AND NATIONAL GRADING RULES FOR <br />SOFTWOOD DIMENSIONAL LUMBER. ALL MEMBERS ARE TO BEAR T HE STAMP OF THE <br />WWPA. MOISTURE CONTENT AT THE TIME OF FRAMING IS TO BE 19% OR LESS. <br />2. MINIMUM DIMENSIONAL LUMBER GRADES ARE TO BE: <br />WALL STUDS 2x DF STUD GRADE <br />WALL PLATES 2x DE STANDARD GRADE <br />2x PT DE STANDARD GRADE <br />PER PLAN AT CONCRETE <br />JOISTS 2x DF #2 <br />HEADERS/BEAMS 4x, 6x DF #2 <br />P 0 S T S 4x, 6x DF #2 <br />3. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED <br />LUMBER, NAILS AND PLATE WASHERS IN CONTACT WITH TREATED LUMBER SHALL BE <br />HOT -DIPPED GALVANIZED. ANCHOR BOLTS AND LAG SCREWS IN TREATED LUMBER SHALL <br />BE HDG OR ZINC COATED. PLAIN CARBON STEEL FASTENERS MAY BE USED WITH <br />ZINC —BORATE TREATED LUMBER. <br />4. FOUNDATION SILL PLATES ARE TO BE BOLTED TO THE CONCRETE FOUNDATION WITH <br />%" 0 ANCHOR BOLTS EMBED A MINIMUM 7" OR %5'0 MECHANICAL ANCHORS EMBED AS <br />SPECIFIED ON DRAWINGS, PROVIDE A MINIMUM OF TWO BOLTS PER PLATE SECTION A <br />MAXIMUM OF 9" FROM THE PLATE END. MAXIMUM SPACING OF ANCHORS IS TO BE <br />4'-0". PROVIDE 0.229"x3" SQ. WASHERS AT ALL ANCHOR BOLTS. WASHER EDGES <br />MUST BE WITHIN %" OF WALL SHEATHING, <br />5. SHOT PIN ATTACHMENTS FOR SILL PLATES ARE TO BE SIMPSON FASTENERS OR <br />APPROVED ALTERNATE. SHOT PIN SIZES ARE AS FOLLOWS: <br />PLATE <br />EMBED <br />SHOT PIN <br />THICKNESS <br />MATERIAL <br />2x <br />CONC <br />PDPWL-250M_t_ C <br />2x <br />STEEL <br />PDPAW--200 <br />6, BOLTS IN WOOD BEAMS SHALL NOT BE LESS THANK 7 DIAMETERS FROM THE END AND <br />4 DIAMETERS FROM THE MEMBER EDGE. PROVIDE STANDARD WASHERS FOR ALL NUTS <br />BEARING AGAINST WOOD. <br />7. FASTEN ALL MEMBERS IN ACCORDANCE WITH IBC TABLE 2304,10.1, UNLESS NOTED <br />OTHERWISE. PROVIDE MINIMUM 1Y2" EMBED FOR ALL NAILS. NAIL SIZES ARE AS <br />FOLLOWS: <br />NAIL <br />MIEN. SHANK DIA, <br />d d <br />10d <br />0.148" <br />16d <br />0.162" <br />8. HOLES AND NOTCHES IN WOOD MEMBERS ARE TO BE LIMITED AS FOLLOWS: <br />L/3 <br />JOIST <br />BEAM <br />MAX. HOLE DIA. V <br />40% STUD DEPTH <br />13/B" FOR 2x4 5 „ NO MORE THAN <br />2%" FOR 2x6\ T� E I TWO SUCCESSIVE <br />% DOUBLED STUDS <br />ARE ALLOWED <br />MAX. NOTCH v <br />25% STUD DEPTH <br />FOR 2x4 <br />FOR 2x6 " \ <br />r � / <br />HOLES ARE NOT <br />PERMITTED IN <br />SAME SECTION x--DBL STUD FOR HOLE <br />AS NOTCH DIA, OF -UP TO 60% <br />STUD DEPTH <br />2/" FOR 2x4 <br />STUDS A' FOR 2x6 <br />GL-U-LAMINA TED MEMBERS <br />I. SINGLE -SPAN GLU-LAMINATED WOOD MEMBERS ARE TO BE DOUGLAS FIR, KILN DRIED <br />AND AITC SPECIFICATION 24F-V4, UNLESS NOTED OTHERWISE. MULTI -SPAN OR <br />CANTILEVERED GLU-LAMINATED WOOD MEMBERS TO BE AITC SPECIFICATION 24F-V8, <br />UNLESS OTHERWISE NOTED, BEAMS ARE HAVE A 2,000 FT RADIUS CAMBER, UNLESS <br />NOTED OTHERWISE. <br />2. MATERIALS MUST BE OBTAINED FROM AN AITC APPROVED FABRICATOR AND BEAR <br />THE AITC STAMP. <br />3. THE GLUE IS TO BE A "WET -USE" ADHESIVE. <br />VI/00D TRUSSES <br />1. SUBMIT SHOP DRAWINGS AND CALCULATIONS STAMPED; SIGNED, AND DATED BY A <br />LICENSED ENGINEER, IN THE STATE OF THE PROJECT TO THE ENGINEER OF RECORD <br />FOR REVIEW. <br />2. TRUSS PLATES ARE TO BE ICBO APPROVED. TOP CHORDS ARE TO BE DOUGLAS FIR <br />#2 OR BETTER, <br />3. INSTALL BRIDGING, WEB, AND CHORD BRACING AS REQUIRED BY THE TRUSS <br />FABRICATOR. <br />4. TEMPORARY SHORING AND BRACING OF THE TRUSSES DURING ERECTION IS THE <br />RESPONSIBILITY OF THE CONTRACTOR. <br />MANUFACTURED LUMBER <br />1, PARALLEL STRAND LUMBER (PSL) IS TO BE 2.0E PARALLAM MANUFACTURED BY <br />TRUSJOIST BY WEYERHAUESER OR ENGINEER APPROVED EQUAL. <br />2. LAMINATED VENEER LUMBER (LVL) IS TO BE 2.0E MICROLLAM MANUFACTURED BY <br />TRUSJOIST BY WEYERHAUESER OR ENGINEER APPROVED EQUAL. <br />3, LAMINATED STRAND LUMBER (LSL) IS TO BE: <br />0 1A WIDE LSL 1.3E OR BETTER <br />8 3%2" WIDE LSL 1.55E OR BETTER <br />MANUFACTURED BY TRUSJOIST BY WEYERHAUESER OR ENGINEER APPROVED EQUAL. <br />4, MANUFACTURED I -JOISTS ARE TO BE TJI SERIES MEMBERS AND SPECIFIED IN THE <br />DRAWINGS MANUFACTURED BY TRUSJOIST BY WEYERHAUESER OR ENGINEER <br />APPROVED EQUAL, <br />WOOD SHEATHING <br />1. ROOF SHEATHING. MINIMUM THICKNESS PER PLAN. APA RATED, EXP--1 RATING, EDGE <br />SEALED PANELS CONFORMING TO INDENTIFICA TION INDEX 32/16 FOR SLOPES GREATER <br />THAN 3/12 AND 40120 FOR SLOPES 3/12 AND LESS, PROVIDE MINIMUM 1/8" CLEAR <br />BETWEEN PANELS TO ALLOW FOR EXPANSION. NAIL 6 INCHES ON CENTER ALONG <br />EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS, UNLESS NOTED <br />OTHERWISE, USE 8d COMMON NAILS. <br />2. FLOOR SHEATHING. MINIMUM THICKNESS PER PLAN. APA RATED STUDD-1-FLOOR, <br />EXP-1 RATING, TONGUE AND GROOVE EDGES CONFORMING TO IDENTIFICATION INDEX <br />4\24, PROVIDE MINIMUM 1/8" CLEAR BETWEEN PANELS TO ALLOW FOR EXPANSION. <br />NAIL AND GLUE TO SUPPORTS. GLUE ADHESIVE IS TO CONFORM TO APA SPECIFICATION <br />AFG-01. NAIL 6 INCHES ON CENTER ALONG EDGES AND 12 INCHES ON CENTER AT <br />INTERMIEDIATE SUPPORTS, UNLESS NOTED OTHERWISE. USE 10d COMMON NAILS, <br />LAYOUT PANELS <br />PERPENDICULAR <br />STAGGER PANEL_ TO FRAMING, TYP, <br />PANEL EDGE NAILING \JOINTS, TYP. <br />AT DIAPHRAGM \ _ <br />\ PERIMETER <br />EDGE NAILING <br />AT ALL- SUPPOR IED\ <br />PANEL EDGES _: -�\�- � <br />FIELD NAILING— \--= ��% PANEL EDGE <br />AI INTERMEDIATE \ � V NAILING AT <br />SUPPORTS, TYP �� /'_A \ ALL PANEL <br />EDGES <br />V� �\ BLOCKED <br />\� \ DIAPH�4AGM <br />T\ LI \ IE NOTED <br />j <br />i PER PLAN <br />UNBLOCKED- <br />��� FLAT 2x4 BLKG AT <br />DIAPHRAGM ' ALL UNSUPPORTED <br />TYP, U. N. 0. PANEL EDGES <br />ROOF/FLOOR DIAPHRAGM NAILING <br />3. WOOD SHEARWALL SHEATHING. MINIMUM THICKNESS PER PLAN. PLYWOOD OR OSB APA <br />RATED, EXP-1 RATING. NAILING PER DRAWINGS. <br />MECHANICAL HARDWARE CONNECTORS <br />1. ALL MECHANICAL HARDWARE USED FOR CONNECTIONS ARE TO BE MANUFACTURED <br />BY SIMPSON STRONG TIE OR EQUIVALENT HAVING A CAPACITY GREATER THAN OR <br />EQUAL. <br />2. ALL MECHANICAL CONNECTORS USED WITH PRESSURE TREATED WOOD ARE TO HAVE <br />A ZINC FINISH UNLESS NOTED OTHERWISE ON THE PLANS. <br />3, FASTENERS ARE TO MATCH MANUFACTURER'S SPECIFICATION, ALWAYS USE HIGHEST <br />CAPACITY REQUIREMENTS, FASTENERS USED WITH ZINC COAT FINISH CONNECTORS <br />ARE TO BE HOT -DIPPED GALVANIZED CONFORMING TO ASTM A15A FILL ALL <br />HOLES WITH FASTENERS AND DO NOT OVER DRIVE. <br />4. THROUGH BOLT FASTENERS ARE TO BE MACHINE BOLTS CONFORMING TO ASTM <br />STANDARD A307, GRADE A. NUTS USED WITH THROUGH BOLTS, THREADED RODS <br />AND ANCHOR BOLTS SHALL BE AT LEAST FLUSH WITH THE TOP OF NUT, <br />5. JOISTS AND BEAMS SHALL BEAR FULLY ON THE CONNECTOR SEAT AND THE GAP <br />BETWEEN MEMBERS SHALL NOT EXCEED 1/8 <br />ABBREVIATIONS: <br />A. BOLT ANCHOR BOLT <br />ADD'L ADDITIONAL <br />A.F.F ABOVE FINISH FLOOR <br />ALT ALTERNATE <br />APPROX APPROXIMATE <br />ARCH ARCHITECTURAL <br />BLKG BLOCKING <br />BM BEAM <br />B.0.0. BOTTOM OF OPENING <br />BTM BOTTOM <br />B R G BEARING <br />BTW BETWEEN <br />CLR CLEAR <br />CMU CONCRETE MASONRY UNIT <br />COL COLUMN <br />CONC CONCRETE <br />COND CONDITION <br />CONN CONNECTION <br />CONS T CONSTRUCTION <br />CONT CONTINUOUS <br />DBL DOUBLE <br />DIA DIAMETER <br />DIM DIMENSION <br />DL DEAD LOAD <br />FA EACH <br />FF EACH FACE <br />ELEV ELEVATION <br />EN EDGE NAILING <br />EQ EQUAL <br />EQUIP EQUIPMENT <br />ES EACH SIDE <br />EXIST EXISTING <br />EXT EXTERIOR <br />FD FLOOR DRAIN <br />FDN FOUNDA TION <br />EF FINISH FLOOR <br />FG FINISH GRADE <br />FLFR FLUSH FRAMED <br />FLR FLOOR <br />FT FEET <br />FTC FOOTING <br />ERI FIRE RETARDANT TREATED <br />FS FAR SIDE <br />GA GAUGE <br />GALV GALVANIZED <br />GLB GLUE LAMINATED BEAM <br />HER HEADER <br />HGR HANGER <br />HORIZ H IORIZONTAL <br />HT HEIGHT <br />LE. INSIDE FACE <br />IN INCH <br />LL LIVE LOAD <br />I'd AX MAXIMUM <br />MECH MECHANICAL <br />MFR MANUFACTURER <br />MIN MINIMUM <br />MISC MISCELLANEOUS <br />NS NEAR SIDE <br />NTS NOT TO SCALE <br />0, C. ON CENTER <br />PARA PARALLEL <br />PERP PERPENDICULAR <br />PSF POUNDS PER SQUARE FOOT <br />PSI POUNDS PER SQUARE INCH <br />PT PRESSURE TREATED <br />RAP RAMMED AGGREGATE PIER <br />REINF REINFORCING <br />REQ'D REQUIRED <br />SCHD SCHEDULE <br />SEC SECTION <br />SE SQUARE FEET <br />SIM SIMILAR <br />SPEC SPECIFICATIONS <br />STD STANDARD <br />STL STEEL <br />STRUC T STRUCTURAL <br />SW SHEARWALL <br />THRU THROUGH <br />TOO TOP OF CONCRETE <br />T OF TOP OF FOOTING <br />T.0.0. TOP OF OPENING <br />TOS TOP OF STEEL <br />TOVV TOP OF WAIL <br />IS TUBE STEEL <br />T YP TYPICAL <br />U.N.O. UNLESS NOTED OTHERWISE <br />VERT VERTICAL <br />W/ WI T H <br />WF WIDE FLANGE <br />WHS WELDED HEADED STUD <br />WTS WELDED THREADED STUD <br />WT WEIGHT <br />VdWR WELDED WIRE REINFORCING <br />SHEET INDEX: <br />Si <br />- ########I`#### <br />S1.1 <br />- ############# (CONY.) <br />S2 <br />- FOUNDATION & FRAMING PLANS <br />S3 <br />- SHEARWALL PLANS <br />S4 <br />- DE T AILS <br />S4.1 <br />- DETAILS (CONY) <br />