My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2320 RAILWAY AVE 2018 INTERWEST CONSTRUCTION INC Plans 2023-02-28 (2)
>
Address Records
>
RAILWAY AVE
>
2320
>
INTERWEST CONSTRUCTION INC
>
Plans
>
2320 RAILWAY AVE 2018 INTERWEST CONSTRUCTION INC Plans 2023-02-28 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2023 3:45:58 PM
Creation date
2/23/2023 2:48:18 PM
Metadata
Fields
Template:
Address Document
Street Name
RAILWAY AVE
Street Number
2320
Tenant Name
INTERWEST CONSTRUCTION INC
Permit
PW1809-013
Year
2018
Notes
CONSTRUCTION OF RAILWAY AVE ROAD AND UTILITY IMPROVEMENTS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
25 <br />20 <br />15 <br />Mn <br />Mn <br />e <br />to 10 <br />a <br />0 <br />N <br />C\' <br />0 <br />5 <br />0 <br />rn <br />a <br />v <br />Ni <br />u <br />I <br />.L.0 0 <br />Permit #: PW1809-013 <br />Site Address: 2320 RAILWAY AVE <br />Owner: ERT LLC <br />APP. Date: 9/10/2018 <br />L=142.94 Description: CONSTRUCTION OF RAILWAY AVE ROAD <br />R-1 <br />4= 115.35 <br />AND UTILITY IMPROVEMENTS <br />Reviewed By: Date: <br />- Office Set Job Site Set Fire/Planning Set a <br />--- ' m <br />RPBA REQUIRED IN ABOVE -GROUND <br />HOT BOX ON DOMESTIC SERVICE. DCVA f <br />/ w <br />REQUIRED IN VAULT DOWNSTREAM OF j 'TIi��� ,�'�\E \� } lL, i _r' ' iJf -.._ / w o <br />IRRIGATION METER. BOTH ARE TO BE __ -__— - -~ , \ U, <br />INSTALLED UNDER SEPARATE PERMIT. ``' <br />LEGENDC�l o <br />PROPOSED FEATURES- CN <br />o 0 <br />20 <br />8 8 g � a) <br />i \ yy WATER PIPING ! 04 `�' <br />6 5 18 N28'44'40"W 397.98' - i o 0 <br />N � �� FIRE WATER PIPING <br />C3 <br />o a <br />; DEDICATION <br />I ; TO CITY OFEVERETT \ o <br />-' <br />IRRIGATION SERVICE <br />IF <br />o � <br />9` <br />_18 9 -- W i WATER METER o <br />W 21 LF 9 g 21 LF 236 LF 1 20 LF 12 _ 547 LF 1 { `-' cn 04 �o <br />_ CN <br />RAI WAY VE �: o W H GATE VALVE m <br />U) - _ W � W � W _ W W W --r-- NL_ _ �iY _ w w '^ <br />W w w w w w --�= w~ w w w = > Y <br />TH S <br />W _. _ __.... .. ___ _ ► RU T BLOCK <br />N: 362540.57 +._-._ <br />[ _ N:362747.90 I ¢ W N: 362536.74 N: 362765.56 <br />W 1 2 1 2 1 _- 11 1 3 _ _ c, __ __. > o 0 <br />181 LF E.1311827.94 5 LF E.1311825.84 - E,1311712.12 — n CA <br />Uj <br />�_ <br />- R f - 20 LF E:1311702.43 ` ' _ - - I w to P 3 v <br />W — _� - <br />,,� �i "'__"_. �.� �B' -� -` � LIMITS OF DISTURBANCE a o o v a v"i <br />Z----- ---- -----------------------------�9-------- <br />l w <br />. W <br />J 18 18 1� <br />— —_ i Z <br />____ FM MAIN <br />- =- 17 <br />20 <br />17 SANITARY EWER F <br />t� <br />^,� .._ � _ , _ OBTAIN 'TEMPORARY � � <br />PIPE FITTING <br />l <br />- CONSTRUCTION EASEMENT,ce <br />F <br />SEE NOTE 11 THIS SHEET' '� I— <br />\. \ FIRE HYDRANT <br />E <br />19 <br />GENERAL NOTES <br />a <br />O H <br />\ i o <br />4 - _... ._. _. <br />A ,i �? \ �� _ 1. 1 F PROJECT N ELATED TO TER <br />a , AIR �_ �J - — > - — <br />� �� ���i�,� � �)�G �,� SEE SHEET CO OR PR NOTES R WA <br />DISTRIBUTION. <br />_ C�J T �i UV ' ��i� t 4L U <br />l• <br />- . ALL WATER PIPINGLARGER SHALL BE THRUST <br />t ,. <br />D G SHA <br />BLOCKED PER DETAIL DIIC4.7. <br />S� <br />_ sP <br />00 <br />r u <br />,, _F � _ — LARGER <br />-__UTrirRESTRAINED JOINTS <br />3 ALL FITTINGS 6" AND LA SHALL HAVE MEGALUG <br />s <br />_= <br />{: <br />LO <br />� <br />4. THE BURIED UTILITIES ON THIS PLAN ARE SHOWN IN THEIR Z co q <br />APPROXIMATE LOCATION WHERE KNOWN. OTHER EXISTING <t <br />> <br />BURIED UTILITIES MAY NOT BE SHOWN ON THESE PLANS. THE J Z > M 8 <br />�r C ALL UTILITY COMPANIES AND o <br />J C <br />CONTRACTOR SHALL CONTACT A TILI NIES N <br />- SD _ <br />HAVE THEIR LOCATION MARKED ON THE GROUND PRIOR TO ., cn o " <br />4) <br /><_ -�:- _ CONTRACTOR WILL PROTECT, OR <br />_. _w <br />� �� � TAIR, ANY DAMAGED UTILITY "DISCOVERED" � � - �� IMMEDIATELY REP <br />.:%LL <br />�,., _._ ,� b-0. µ .. .. ____ _ _ _ _..w _-.,- .- _� � ON THIS PROJECT WITHOUT ADDITIONAL COSTS. 9' <br />NORTH 5. ALL WATER MAINS SHALL MAINTAIN "A MINIMUM COVER OF F <br />UTILITY PLAN HORIZONTAL SCALE: 1"=20' 48 AND A MAXIMUM COVER OF 60 . W = W <br />. ALL GATE VALVES SHALL BE INSTALLED WITH VALVE BOX � <br />6 <br />20 O 20 40 4 <br />SCALE:1"=20' wamw AND EXTENSION PER 61/C4.8. CL <br />_� <br />7. ALL DUCTILE IRON PIPING AND FITTINGS SHALL BE ENCASED V1 z z <br />WITHIN A POLYETHYLENE WRAP FOR ANTICORROSION m 0 z <br />PURPOSES. <br />w <br />W <br />V <br />m <br />o <br />8. <br />RESTRAINED JOINTS SHALL BE USED ON ALL VALVES, PIPING, <br />Q <br />W <br />V <br />°_- <br />AND FITTINGS ON STUBOUTS. <br />a <br />9. <br />AVERAGE SPACING BETWEEN FIRE HYDRANTS ON ROAD <br />FRONTAGE SHALL BE NO LESS THAN 400'. FIRE FLOW SHALL <br />BE NO LESS THAN 1,750 GPM. <br />10. <br />ANY PROCESS WATER SHALL FEED OFF OF THE DOMESTIC <br />SERVICE. PROCESS WATER IS NOT PERMITTED FROM FIRE <br />SERVICES. <br />0 <br />11. <br />TEMPORARY CONSTRUCTION EASEMENT REQUIRED PRIOR TO <br />U <br />04a <br />CONSTRUCTION ON CITY OF EVERETT PROPERTY. COORDINATE <br />Z <br />W <br />'d" <br />WITH CITY OF EVERETT REAL PROPERTY DIVISION. <br />cf)~ <br />O <br />to <br />LO <br />W <br />U <br />>- <br />KEYNOTES <br />m <br />z <br />XLn <br />12" 0 CL52 DUCTILE IRON (D.IPIPE, SEE PLAN FOR LENGTH. <br />W <br />� <br />J <br />O <br />~ <br />o <br />(1) 12" x 2" TEE WITH CONCRETE THRUST BLOCK <br />Z <br />z <br />p <br />M <br />Z <br />(1) 2-GATE VALVE <br />o <br />to <br />m <br />O <br />(1) 12" x 12" TEE WITH CONCRETE THRUST BLOCK <br />o <br />O <br />U <br />U <br />(1) 12" GATE VALVE <br />W <br />25 <br />NOT USED <br />a <br />2" IRRIGATION METER PER DETAIL 63/C4.7 <br />6�- 2" DOMESTIC WATER METER PER DETAIL B3/C4.7 <br />20 <br />12" FIRE WATER METER PER DETAIL D3/C4.7 <br />co <br />8� CAP LINE AT 2' FROM METER <br />z <br />W <br />9� 2"0 COPPER PIPE, SEE PLAN FOR LENGTH. <br />MW <br />W <br />j <br />15 <br />10 12"0 CL52 DUCTILE IRON (D.I.) PIPE, <br />O <br />0 <br />SEE PLAN FOR LENGTH. <br />W <br />11 FIRE HYDRANT ASSEMBLY <br />M <br />a <br />PER DETAILS D1 AND D3/C4.8 <br />Q <br />z <br />10 <br />12 6"0 CL52 DUCTILE IRON (D.I.) PIPE, SEE PLAN <br />= W <br />Q <br />FOR LENGTH. <br />z _ <br />W <br />z <br />W <br />J <br />5 <br />�- <br />W <br />Lr <br />a.?MM'. <br />1- <br />w <br />J <br />''— <br />cc a: <br />' <br />SHEET <br />NO. <br />1/+uu 1i+Zu <br />]/+4u 1i+bu 1i+6u 16+Uu 16+Zu 16+4u 16+eu 16+60 19+00 <br />19+20 19+40 19+60 19+80 20+00 20+20 20+40 20+60 20+80 21+00 21+20 21+40 21+60 21+80 22+00 22+10 <br />3 <br />WATER PROFILE <br />C4,3 <br />HORIZONTAL SCALE: 1"=20' <br />200 20 40 <br />PROJECT N0. <br />WATER PROFILE <br />Call 811 <br />SCALE:1"=20' <br />S VERTICAL SCALE: 15=5' 10 <br />two business days <br />16-before <br />17754 <br />you dig <br />
The URL can be used to link to this page
Your browser does not support the video tag.