Laserfiche WebLink
SPECIAL INSPECTION <br />ABBREVIATIONS <br />DESIGN CRITERIA <br />1. GOVERNING BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE <br />AMMENDMENTS <br />2. RISK CATEGORY........................................................................... [I <br />3. SEISMIC <br />0.2 SEC. SPECTRAL RESPONSE ACCELERATION (Ss) .................................... 1.368 <br />1.0 SEC. SPECTRAL RESPONSE ACCELERATION (S1).................................... 0,435 <br />DESIGN SPECTRAL ACCELERATION (SDS) ....................... 1.094 <br />DESIGN SPECTRAL ACCELERATION (SD1)............................................... 0.532 <br />SITE CLASSIFICATION ................................... ............................. D <br />SEISMIC DESIGN CATEGORY ............................................................... D <br />IMPORTANCE FACTOR ............ ................. ............. ....... <br />:... 1 <br />GENERAL <br />1. THE PROJECT SPECIFICATIONS, DRAWINGS, STANDARD DETAILS, DETAILS IN THE DRAWINGS, AND THE <br />STRUCTURAL NOTES ARE TO BE COMPLEMENTARY. IN THE CASE OF AN INCONSISTENCE NOT CLARIFIED <br />BY THE DESIGNER OF RECORD THE MOST STRINGENT, HIGHEST QUALITY AND BEST QUALITY PROVISIONS <br />SHALL BE PROVIDED. <br />2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE CONSTRUCTION. THE ARCHITECT SHALL BE <br />NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES.DO NOT SCALE DRAWINGS; COORDINATE <br />DIMENSIONS WITH ARCHITECTURAL DRAWINGS. <br />3. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE LATEST EDITION OF THE <br />INTERNATIONAL BUILDING CODE WITH AMENDMENTS. <br />4. SEE ARCHITECTURAL DRAWINGS INCLUDING BUT NOT LIMITED TO THE FOLLOWING: <br />A. SIZE AND LOCATION OF ALL OPENINGS, EXCEPT AS NOTED. <br />B. SIZE AND LOCATION OF ALL INTERIOR AND EXTERIOR NONBEARING WALLS <br />C. SIZE AND LOCATION OF ALL CONCRETE CURBS, FLOOR DRAINS, SLOPES, DEPRESSED AREAS, <br />CHANGES IN LEVEL, CHAMFERS, GROOVES, INSERTS, ETC. <br />D. SIZE AND LOCATION OF ALL FLOOR AND ROOF OPENINGS, EXCEPT AS SHOWN. <br />E. FLOOR AND ROOF FINISHES. <br />F. STAIR FRAMING AND DETAILS, EXCEPT AS SHOWN. <br />G. DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS. <br />5. SEE CONSTRUCTION DOCUMENTS FOR THE FOLLOWING, INCLUDING BUT NOT LIMITED TO: <br />A. PIPE RUNS, SLEEVES, HANGERS, TRENCHES, WALL AND SLAB OPENINGS, ETC., EXCEPT AS SHOWN OR <br />NOTED. <br />B. ELECTRICAL CONDUIT RUNS, BOXES, OUTLETS IN WALLS AND SLABS. <br />C. CONCRETE INSERTS FOR FIXTURES. <br />D. SIZE AND LOCATION OF MACHINE OR EQUIPMENT BASES, ANCHOR BOLTS FOR MOTOR MOUNTS. <br />E. SEISMIC BRACING REQUIREMENTS. <br />6. METHODS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE <br />CONTRACTOR, THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE <br />THE INTEGRITY OF THE STRUCTURE AT ALL STAGES OF CONSTRUCTION. <br />7. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. <br />THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL <br />MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKERS AND VISITORS DURING CONSTRUCTION. <br />SUCH MEASURE SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR CONSTRUCTION <br />LOADS, ETC. VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE REVIEW OF THE <br />ABOVE ITEMS. <br />S. OPENINGS, POCKETS, ETC. SHALL NOT BE PLACED IN STRUCTURAL ELEMENTS UNLESS SPECIFICALLY <br />DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. <br />9. CONSTRUCTION LOAD (MATERIAL AND EQUIPMENT) SHALL NOT EXCEED THE DESIGN LIVE LOAD PER <br />SQUARE FOOT. PROVIDE ADEQUATE SHORING AND/ OR BRACING WHERE STRUCTURES HAVE NOT <br />ATTAINED DESIGN STRENGTH. <br />10. WHEN A DETAIL IS IDENTIFIED, THE CONTRACTOR SHALL APPLY THIS DETAIL. IN ESTIMATING AND <br />CONSTRUCTION TO EVERY LIKE CONDITION WHETHER OR NOT THE REFERENCE IS MADE IN EVERY <br />INSTANCE. <br />11. ANY REFERENCES TO THE RECOMMENDATIONS, GUIDELINES, OR REQUIREMENTS IN NATIONAL <br />PUBLICATIONS, SUCH AS BUT NOT LIMITED TO ASCE, ASTM, IBC, ACI, AISC, NDS, OR AWS, IN THE <br />CONSTRUCTION DOCUMENTS SHALL BE FOLLOWED AS IF THEY ARE SPECIFICALLY MANDATED. <br />POST -INSTALLED ANCHORS <br />INSPECTIONIN ACCORDANCE WITH IBC CHAPTER 17, THE FOLLOWING TYPES OF WORK REQUIRE SPECIAL <br />INSPECTION. SEE THE SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL REQUIREMENTS FOR <br />AND TESTING. SPECIAL INSPECTION SHALL BE PAID FOR AND PROVIDED <br />OWNER. <br />FREQUENCY <br />I <br />U) <br />- <br />O <br />' z <br />p <br />O <br />[ <br />z <br />wO <br />MATERIAL <br />— TASK <br />�T <br />RESPONSIBLE FIRM <br />BOLTS INSTALLED IN CONCRETE <br />INSP <br />SPECIAL INSPECTOR <br />l <br />REINFORCED CONCRETE <br />_ <br />INSP <br />- <br />INSPECTOR <br />PLACEMENT <br />fSPECIAL <br />C <br />E <br />ADHESIVE ANCHORS <br />INSP <br />- <br />SPECIAL INSPECTOR <br />CONCRETE <br />EXPANSION ANCHORS <br />- <br />INSP <br />SPECIAL INSPECTOR <br />SPECIFIED CURING TECHNIQUES <br />- <br />INSP <br />SPECIAL INSPECTOR <br />CONCRETE MATERIALS <br />- <br />TEST <br />TESTING LAB_ <br />NOTES: <br />FIELDI SPECIAL INSPECTION OF SHOP FABRICATION AND SHOP WELDING SHALL MATCA TRE <br />REQUIREMENTS FOR FABRICATION AND FIELD WELDING UNLESS SHOP <br />SECTIONCERTIFICATION DOCUMENTS ARE REVIEWED AND ACCEPTED BY THE OWNER. IF <br />APPROVED BY THE OWNER, SPECIAL INSPECTION OF SHOP FABRICATION AND SHOP <br />WELDING SHALL NOT BE REQUIRED FOR CERTIFIED FABRICATORS AS REQUIRED BY THE <br />STRUCTURAL STEEL OF GENERAL STRUCTURAL NOTES.. <br />INDEPENDENTCOMPLETE-PENETRATION WELDS ARE REQUIRED TO BE ULTRASONICALLY TESTED BYAN <br />2. CONTINUOUS INSPECTIONR D FOR WELDING OF _ <br />FLEXURAL & AXIAL FORCES IN INTERMEDIATE & SPECIAL MOMENT <br />BOUNDARY <br />ELEMENTS OF SPECIALRA •CONCRETE, & .. REINFORCEMENT, <br />PERIODIC INSPECTION IS ACCEPTABLE FOR WELDING OF OTHER REINFORCING STEEL. <br />@ <br />AT <br />JST <br />JOIST <br />AB <br />ANCHOR BOLT <br />K <br />KIPS <br />ACI <br />AMERICAN CONCRETE INSTITUTE <br />KSF <br />KIPS PER SQUARE FOOT <br />ADD'L <br />ADDITIONAL <br />KSI <br />KIPS PER SQUARE INCH <br />AESS <br />ARCHITECTURALLY EXPOSED <br />L <br />ANGLE <br />STRUCTURALSTEEL <br />AFF <br />ABOVE FINISH FLOOR <br />LL <br />LIVE LOAD <br />AISC <br />AMERICAN INSTITUTE OF STEEL <br />LLH <br />LONG LEG HORIZONTAL <br />CONSTRUCTION <br />ALT <br />ALTERNATE <br />LLV <br />LONG LEG VERTICAL <br />APPROX <br />APPROXIMATE <br />LONG <br />LONGITUDINAL <br />ARCH <br />ARCHITECTURAL) <br />LSL <br />LAMINATED STRAND LUMBER <br />AIR <br />ALL -THREAD ROD <br />LVL <br />LAMINATED VENEER LUMBER <br />B/ <br />BOTTOM OF <br />MAS <br />MASONRY <br />BE <br />BOUNDARY ELEMENT <br />MATL <br />MATERIAL <br />BLDG <br />BUILDING <br />MAX <br />MAXIMUM <br />BLKG <br />BLOCKING <br />MB <br />MACHINE BOLT <br />BM <br />BEAM <br />MECH <br />MECHANICAL <br />BN <br />BOUNDARY NAILING) <br />MFR <br />MANUFACTURER <br />BOTT <br />BOTTOM <br />MIN <br />MINIMUM <br />BRG <br />BEARING <br />MISC <br />MISCELLANEOUS <br />BTWN <br />BETWEEN <br />MTL <br />METAL <br />CFS <br />COLD FORMED STEEL <br />(N) <br />NEW <br />CIP <br />CAST -IN -PLACE <br />NIC <br />NOT IN CONTRACT <br />CJ <br />CONTROL JOINT <br />NO. / ## <br />NUMBER <br />CL / <br />CENTER LINE <br />NOM <br />NOMINAL <br />CLR <br />CLEAR <br />INS <br />NEAR SIDE <br />CMU <br />CONCRETE MASONRY UNIT <br />N T E <br />NOT TO EXCEED <br />COL <br />COLUMN <br />NTS <br />NOT TO SCALE <br />CONC <br />CONCRETE <br />OC <br />ON CENTER <br />CONN <br />CONNECTION <br />OD <br />OUTSIDE DIAMETER <br />CONS T JOINT <br />CONSTRUCTION JOINT <br />OF / OSF <br />OUTSIDE FACE <br />CONT <br />CONTINUOUS <br />OH <br />OPPOSITE HAND <br />COORD <br />COORDINATE <br />OPNG <br />OPENING <br />CTR/CNTR <br />CENTER <br />OPP <br />OPPOSITE <br />d <br />PENNY (NAILS) <br />OWWJ <br />OPEN WEB WOOD JOIST <br />DBA <br />DEFORMED BAR ANCHOR <br />PDA <br />POWDER DRIVEN ANCHOR <br />DBL <br />DOUBLE <br />Pi <br />PANEL JOINT <br />DC <br />DEMAND CRITICAL WELD <br />PL <br />PLATE <br />DET / DTL <br />DETAIL <br />PLB <br />PARALLAM BEAM <br />DFL <br />DOUGLAS FIR/I ARCH <br />PLYWD / PLY <br />PLYWOOD <br />DIA / O <br />DIAMETER <br />PNL <br />PANEL <br />DIAPH <br />DIAPHRAGM <br />PS <br />POUR STRIP <br />DIM <br />DIMENSION <br />PSF <br />POUNDS PER SQUARE FOOT <br />DL <br />DEAD LOAD <br />PSI <br />POUNDS PER SQUARE INCH <br />DWG <br />DRAWING <br />PSL <br />PARALLEL STRAND LUMBER <br />E/ <br />EDGE OF <br />PT <br />PRESSURE TREATED <br />EA <br />EACH <br />REF <br />REFERENCE <br />EF <br />EACH FACE <br />Ill <br />REINFORCING <br />EIFS <br />EXTERIOR INSULATED FINISH... <br />REQ / REQ'D <br />REQUIRED <br />ELECT <br />ELECTRICAL <br />REV <br />REVISION <br />ELEV <br />ELEVATION <br />SCHED <br />SCHEDULE <br />EN <br />EDGE NAILING) <br />SFRS <br />SEISMIC FORCE RESISTING SYSTEM <br />ENGR <br />ENGINEER <br />SHTG / SHT'G <br />SHEATHING <br />EQ <br />EQUAL <br />SIM <br />SIMILAR <br />ES <br />EACH SIDE <br />SLRS <br />SEISMIC LOAD RESISTIVE SYSTEM <br />EW <br />EACH WAY <br />SLV <br />SHORT LEG VERTICAL <br />EXIST / (E) <br />EXISTING <br />SMS <br />SHEET METAL SCREW <br />EXP JT / EJ <br />EXPANSION JOINT <br />SOG <br />SLAB ON GRADE <br />EXT <br />EXTERIOR <br />SP <br />SPACE (D)(S) <br />F/ <br />FACE OF <br />SPEC(S) <br />SPECIFICATION <br />FB <br />FLAT BAR <br />STAGG <br />STAGGERED <br />FIN <br />FINISH(ED) <br />STD <br />STANDARD <br />FLR <br />FLOOR <br />STIFF <br />STIFFENER <br />FND <br />FOUNDATION <br />T&B <br />TOP & BOTTOM <br />FOW <br />FACE OF WALL <br />T/ <br />TOP OF <br />FS <br />FAR SIDE <br />I HK <br />THICK/THICKNESS <br />FT <br />FEET/FOOT <br />TL <br />TOTALLOAD <br />FTG <br />FOOTING <br />TN <br />TOE NAIL <br />GA <br />GAUGE <br />TRANS/TRANSV <br />TRANSVERSE <br />GALV <br />GALVANIZED <br />TS <br />TUBE STEEL <br />GLB <br />GLULAM BEAM <br />T YP <br />TYPICAL <br />HCM <br />HOLLOW CLAY MASONRY <br />UON i UNO <br />UNLESS OTHERWISE NOTED <br />HDR <br />HEADER <br />VERT <br />VERTICAL <br />HORIZ <br />HORIZONTAL <br />W/ <br />WITH <br />HVAC <br />HEATING, VENTILATION, & AIR <br />W/O <br />WITHOUT <br />CONDITIONING <br />HWS <br />HEADED WELD STUD <br />WD <br />WOOD <br />IBC <br />INTERNATIONAL BUILDING CODE <br />WF <br />WIDE FLANGE BEAM <br />ID <br />INSIDE DIAMETER <br />WP <br />WORK POINT <br />IF <br />INSIDE FACE <br />WWF <br />WELDED WIRE FABRIC <br />INSP <br />INSPECTION / INSPECTOR <br />INT <br />INTERIOR <br />g <br />a 20 <br />Architecture <br />? is Interiors <br />d <br />Planning Engineering <br />r VIA 1�4 . <br />MACKENZIE <br />2019 ALL RIGHTS RESERVED <br />THESE DRAWINGS ARE THE PROPERTY OF <br />MACKENZIE AND ARE NOT TO BE USED <br />OR REPRODUCED IN ANY MANNER, <br />WITHOUT PRIOR WRITTEN PERMISSION <br />Revision Schedule <br />Revision Delta Issue Date <br />DRAWN BY: KAR <br />CHECKED BY: CKN <br />SHEET <br />