PLU ING LEGEND GENERALDEMO <br />A. SHORTEN OR EXTEND ALL EXISTING FLOOR CLEANOUTS AND FLOOR DRAINS TO <br />REFINISHED CONCRETE FLOOR LEVEL INCLUDING GRINDING, DEMOLITION, <br />SYMBOLS ABBREV. DESCRIPTION REPLACEMENT AND WASTE PIPING MODIFICATIONS AS REQUIRED FOR EXISTING <br />CONDITIONS. SAW -CUT, PATCH AND FINISH CONCRETE FLOOR BACK TO MATCH AS <br />SAN SAN SANITARY WASTE BELOW FLOOR OR GRADE <br />REQUIRED. REFER TO ARCHITECTURAL PLAN FOR AREAS WHERE EXISTING CONCRETE <br />FLOORS WILL BE REMOVED. FIELD -VERIFY AND COORDINATE ALL WORK WITH GENERAL <br />- GW GW GREASE WASTE BELOW FLOOR OR GRADE CONTRACTOR PRIOR TO BID. Architecture - Interiors <br />CWV CWV COMBINATION WASTE AND VENT BELOW FLOOR OR GRADE B. THE AS -BUILT DRAWINGS USED TO CREATE THESE DRAWINGS MAY NOT REFLECT EXACT Planning - Engineering <br />ROUTING OR SIZES OF EXISTING PIPING. PLUMBER SHALL VERIFY ALL CONNECTION <br />® ® ® ® ® - ® ® ® ® ® V VENT REQUIREMENTS OF NEW PIPING TO EXISTING PIPING IN FIELD PRIOR TO START OF WORK <br />AND MAKE ADJUSTMENTS TO DESIGN AS REQUIRED. ALL WORK SHALL BE DONE PER <br />® CW COLD WATER STATE & LOCAL JURISDICTIONAL REQUIREMENTS. <br />® HW HOT WATER C. PLUMBING CONTRACTOR SHALL PROVIDE PLUMBING FOR TEMPORARY <br />DEPARTMENTS/PREP AREAS, AS REQUIRED. COORDINATE WITH GENERAL CONTRACTOR Portland, OR <br />— — — HWR HOT WATER RETURN REGARDING TEMPORARY DEPARTMENT/PREP AREAS REQUIRED. 503.224.9560 <br />8 FD FLOOR DRAIN <br />D. FOR ALL DEMOED PLUMBING FIXTURES, CAP WASTE LINES BELOW FLOOR AND VENT Vancouve4 WA <br />LINES ABOVE CEILING, UNLESS OTHERWISE NOTED. 360.695.7579 <br />OR ® FS FLOOR SINK (SQUARE) OR (ROUND) Seattle, WA <br />E. FOR ALL DEMOED PLUMBING FIXTURES, WATER LINES TO BE CAPPED AS CLOSE TO MAIN 206.749.9993 <br />® HD HUB DRAIN AS POSSIBLE, UNLESS OTHERWISE NOTED. <br />wWw,cf9Ze,c® <br />® VTR VENT THROUGH ROOF <br />C HB HOSE BIBB GENERAL <br />NOTES- MACKENZIE. <br />DESIGN DRIVEN I CLIENT FOCUSED <br />S.O.V. SHUT OFF VALVE A. PLUMBER SHALL COORDINATE THE LOCATION OF NEW VENTS THRU THE ROOF. VENTS Client <br />MUST BE A MINIMUM 10'-0" FROM MECHANICAL AIR INTAKE PER CODE. <br />Q FCO/COTG FLOOR CLEANOUT OR CLEANOUT TO GRADE <br />B. THE PLUMBER SHALL POWER WASH ALL EXISTING SANITARY & GREASE WASTE LINES & <br />VIC` WCO WALL CLEANOUT VERIFY THAT ALL ARE DRAINING PROPERLY. FRED MEYER <br />CI=__ PIPE UP C. SHORTEN OR EXTEND ALL EXISTING FLOOR CL€ANOUTS AND FLOOR DRAINS TO STORESINC <br />REFINISHED CONCRETE FLOOR LEVEL INCLUDING GRINDING, DEMOLITION, <br />C PIPE DOWN REPLACEMENT AND WASTE PIPING MODIFICATIONS AS REQUIRED FOR EXISTING 3800 SE 22ND <br />CONDITIONS. SAW -CUT, PATCH AND FINISH CONCRETE FLOOR BACK TO MATCH AS PORTLAND, OR 97202 <br />— PIPE TEE DOWN REQUIRED. REFER TO ARCHITECTURAL PLAN FOR AREAS WHERE EXISTING CONCRETE <br />FLOORS WILL BE REMOVED. FIELD -VERIFY AND COORDINATE ALL WORK WITH GENERAL <br />P.O.C. POINT OF CONNECTION CONTRACTOR PRIOR TO BID. <br />(D) DEMO D. PLUMBER SHALL DISINFECT POTABLE WATER SYSTEM AFTER EACH REMODEL SECTION <br />z f A V61 o <br />(E) EXISTING TO REMAIN PER SPECIFICATIONS AND STATE & LOCAL JURISDICTION. AN <br />(N) NEW <br />(R) RELOCATE E. THE AS -BUILT DRAWINGS USED TO CREATE THESE DRAWINGS MAY NOT REFLECT EXACT <br />A.F.F. ABOVE FINIISHED FLOOR ROUTING OR SIZES OF EXISTING PIPING. PLUMBER SHALL VERIFY ALL CONNECTION <br />REQUIREMENTS OF NEW PIPING TO EXISTING PIPING IN FIELD PRIOR TO START OF WORK <br />B.F.F. BELOW FINISHED FLOOR AND MAKE ADJUSTMENTS TO DESIGN AS REQUIRED. ALL WORK SHALL BE DONE PER <br />I.E. INVERT ELEVATION STATE & LOCAL JURISDICTIONAL REQUIREMENTS. <br />T& P TEMPERATURE AND PRESSURE <br />F. PROVIDE TRAP PRIMERS ON ALL HUB DRAINS, FLOOR DRAINS, TRENCH DRAINS, AND ON <br />FLOOR SINKS WHERE NOT SERVED BY SINKS ABOVE. IF ALLOWED BY JURISDICTION, <br />BASIS OF . DESIGN TRAP GUARDS ARE APPROVED. <br />Project <br />G. DO NOT ATTACH SCREWS, NAILS, HANGERS OR FASTENERS OF ANY TYPE TO ROOF <br />CODES: DECK. <br />2015 INTERNATIONAL MECHANICAL CODE (I.M.C.) H. ALL PIPE DROPS IN SALES AREA FROM ROOF TO LOW WALLS OR EQUIPMENT SHALL BE <br />2015 WASHINGTON STATE ENERGY CODE COORDINATED AND GROUPED TOGETHER WITH OTHER MECHANICAL PIPES. MILL CREEK <br />2015 UNIFORM PLUMBING CODE I. NO SURFACE -MOUNTED WATER OR VENT LINES SHALL BE EXPOSED IN PREP ROOMS. 12906 BOTHELL- <br />2015 INTERNATIONAL FUEL GAS CODE J. ALL CASE DRAINS MUST BE ACCESSIBLE AND SCREENED TO PREVENT RODENT ENTRY. EVERETT HWY <br />EVERT , WA 20 <br />K. ALL PLUMBING FIXTURES OR EQUIPMENT DRAINING INTO THE SANITARY SEWER SYSTEM <br />VIA AN INDIRECT WASTE CONNECTION SHALL HAVE A 1 ° AIR GAP AS REQUIRED BY THE <br />UNIFORM PLUMBING CODE. <br />L. PLUMBER SHALL INSTALL CHECK VALVES IN HOT & COLD WATER SUPPLY LINES TO Mechanical/Electrical <br />OWNER FURNISHED FOOD PREP AND UTENSIL STAINLESS STEEL SINKS IN PREP AREAS. <br />M. ALL WATER HEATERS SHALL BE SET AT 115°, F. t of <br />re <br />N. SAW CUTTING AND TRENCHING ARE SHOWN ON DRAWINGS AS A SHADED AREA AROUND Engineering Consultants Incorporated <br />ALL PIPING. NOT ALL UNDER FLOOR PIPING SHOWN ON DRAWINGS HAVE A SHADED AREA 303 Federal Way Boise, ID 83705 <br />AROUND THE PIPING. Phone: 208.376,9820 Fax: 208376.9822 <br />WtVG ,' ciboise.com <br />0. PLUMBING CONTRACTOR SHALL PROVIDE PLUMBING FOR TEMPORARY <br />DEPARTMENTS/PREP AREAS, AS REQUIRED. COORDINATE WITH GENERAL CONTRACTOR <br />REGARDING TEMPORARY DEPARTMENT/PREP AREAS REQUIRED. <br />P. ALL FLOOR SINKS SHALL BE HALF EXPOSED. <br />PERMIT SET <br />