My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12906 19TH AVE SE 2020 Plans 2023-02-24
>
Address Records
>
19TH AVE SE
>
12906
>
Plans
>
12906 19TH AVE SE 2020 Plans 2023-02-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2023 8:32:55 AM
Creation date
2/23/2023 4:09:06 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12906
Permit
B2004-018
Year
2020
Notes
WITHIN THE WALLS REMODEL OF EXTG STORE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLU ING LEGEND GENERALDEMO <br />A. SHORTEN OR EXTEND ALL EXISTING FLOOR CLEANOUTS AND FLOOR DRAINS TO <br />REFINISHED CONCRETE FLOOR LEVEL INCLUDING GRINDING, DEMOLITION, <br />SYMBOLS ABBREV. DESCRIPTION REPLACEMENT AND WASTE PIPING MODIFICATIONS AS REQUIRED FOR EXISTING <br />CONDITIONS. SAW -CUT, PATCH AND FINISH CONCRETE FLOOR BACK TO MATCH AS <br />SAN SAN SANITARY WASTE BELOW FLOOR OR GRADE <br />REQUIRED. REFER TO ARCHITECTURAL PLAN FOR AREAS WHERE EXISTING CONCRETE <br />FLOORS WILL BE REMOVED. FIELD -VERIFY AND COORDINATE ALL WORK WITH GENERAL <br />- GW GW GREASE WASTE BELOW FLOOR OR GRADE CONTRACTOR PRIOR TO BID. Architecture - Interiors <br />CWV CWV COMBINATION WASTE AND VENT BELOW FLOOR OR GRADE B. THE AS -BUILT DRAWINGS USED TO CREATE THESE DRAWINGS MAY NOT REFLECT EXACT Planning - Engineering <br />ROUTING OR SIZES OF EXISTING PIPING. PLUMBER SHALL VERIFY ALL CONNECTION <br />® ® ® ® ® - ® ® ® ® ® V VENT REQUIREMENTS OF NEW PIPING TO EXISTING PIPING IN FIELD PRIOR TO START OF WORK <br />AND MAKE ADJUSTMENTS TO DESIGN AS REQUIRED. ALL WORK SHALL BE DONE PER <br />® CW COLD WATER STATE & LOCAL JURISDICTIONAL REQUIREMENTS. <br />® HW HOT WATER C. PLUMBING CONTRACTOR SHALL PROVIDE PLUMBING FOR TEMPORARY <br />DEPARTMENTS/PREP AREAS, AS REQUIRED. COORDINATE WITH GENERAL CONTRACTOR Portland, OR <br />— — — HWR HOT WATER RETURN REGARDING TEMPORARY DEPARTMENT/PREP AREAS REQUIRED. 503.224.9560 <br />8 FD FLOOR DRAIN <br />D. FOR ALL DEMOED PLUMBING FIXTURES, CAP WASTE LINES BELOW FLOOR AND VENT Vancouve4 WA <br />LINES ABOVE CEILING, UNLESS OTHERWISE NOTED. 360.695.7579 <br />OR ® FS FLOOR SINK (SQUARE) OR (ROUND) Seattle, WA <br />E. FOR ALL DEMOED PLUMBING FIXTURES, WATER LINES TO BE CAPPED AS CLOSE TO MAIN 206.749.9993 <br />® HD HUB DRAIN AS POSSIBLE, UNLESS OTHERWISE NOTED. <br />wWw,cf9Ze,c® <br />® VTR VENT THROUGH ROOF <br />C HB HOSE BIBB GENERAL <br />NOTES- MACKENZIE. <br />DESIGN DRIVEN I CLIENT FOCUSED <br />S.O.V. SHUT OFF VALVE A. PLUMBER SHALL COORDINATE THE LOCATION OF NEW VENTS THRU THE ROOF. VENTS Client <br />MUST BE A MINIMUM 10'-0" FROM MECHANICAL AIR INTAKE PER CODE. <br />Q FCO/COTG FLOOR CLEANOUT OR CLEANOUT TO GRADE <br />B. THE PLUMBER SHALL POWER WASH ALL EXISTING SANITARY & GREASE WASTE LINES & <br />VIC` WCO WALL CLEANOUT VERIFY THAT ALL ARE DRAINING PROPERLY. FRED MEYER <br />CI=__ PIPE UP C. SHORTEN OR EXTEND ALL EXISTING FLOOR CL€ANOUTS AND FLOOR DRAINS TO STORESINC <br />REFINISHED CONCRETE FLOOR LEVEL INCLUDING GRINDING, DEMOLITION, <br />C PIPE DOWN REPLACEMENT AND WASTE PIPING MODIFICATIONS AS REQUIRED FOR EXISTING 3800 SE 22ND <br />CONDITIONS. SAW -CUT, PATCH AND FINISH CONCRETE FLOOR BACK TO MATCH AS PORTLAND, OR 97202 <br />— PIPE TEE DOWN REQUIRED. REFER TO ARCHITECTURAL PLAN FOR AREAS WHERE EXISTING CONCRETE <br />FLOORS WILL BE REMOVED. FIELD -VERIFY AND COORDINATE ALL WORK WITH GENERAL <br />P.O.C. POINT OF CONNECTION CONTRACTOR PRIOR TO BID. <br />(D) DEMO D. PLUMBER SHALL DISINFECT POTABLE WATER SYSTEM AFTER EACH REMODEL SECTION <br />z f A V61 o <br />(E) EXISTING TO REMAIN PER SPECIFICATIONS AND STATE & LOCAL JURISDICTION. AN <br />(N) NEW <br />(R) RELOCATE E. THE AS -BUILT DRAWINGS USED TO CREATE THESE DRAWINGS MAY NOT REFLECT EXACT <br />A.F.F. ABOVE FINIISHED FLOOR ROUTING OR SIZES OF EXISTING PIPING. PLUMBER SHALL VERIFY ALL CONNECTION <br />REQUIREMENTS OF NEW PIPING TO EXISTING PIPING IN FIELD PRIOR TO START OF WORK <br />B.F.F. BELOW FINISHED FLOOR AND MAKE ADJUSTMENTS TO DESIGN AS REQUIRED. ALL WORK SHALL BE DONE PER <br />I.E. INVERT ELEVATION STATE & LOCAL JURISDICTIONAL REQUIREMENTS. <br />T& P TEMPERATURE AND PRESSURE <br />F. PROVIDE TRAP PRIMERS ON ALL HUB DRAINS, FLOOR DRAINS, TRENCH DRAINS, AND ON <br />FLOOR SINKS WHERE NOT SERVED BY SINKS ABOVE. IF ALLOWED BY JURISDICTION, <br />BASIS OF . DESIGN TRAP GUARDS ARE APPROVED. <br />Project <br />G. DO NOT ATTACH SCREWS, NAILS, HANGERS OR FASTENERS OF ANY TYPE TO ROOF <br />CODES: DECK. <br />2015 INTERNATIONAL MECHANICAL CODE (I.M.C.) H. ALL PIPE DROPS IN SALES AREA FROM ROOF TO LOW WALLS OR EQUIPMENT SHALL BE <br />2015 WASHINGTON STATE ENERGY CODE COORDINATED AND GROUPED TOGETHER WITH OTHER MECHANICAL PIPES. MILL CREEK <br />2015 UNIFORM PLUMBING CODE I. NO SURFACE -MOUNTED WATER OR VENT LINES SHALL BE EXPOSED IN PREP ROOMS. 12906 BOTHELL- <br />2015 INTERNATIONAL FUEL GAS CODE J. ALL CASE DRAINS MUST BE ACCESSIBLE AND SCREENED TO PREVENT RODENT ENTRY. EVERETT HWY <br />EVERT , WA 20 <br />K. ALL PLUMBING FIXTURES OR EQUIPMENT DRAINING INTO THE SANITARY SEWER SYSTEM <br />VIA AN INDIRECT WASTE CONNECTION SHALL HAVE A 1 ° AIR GAP AS REQUIRED BY THE <br />UNIFORM PLUMBING CODE. <br />L. PLUMBER SHALL INSTALL CHECK VALVES IN HOT & COLD WATER SUPPLY LINES TO Mechanical/Electrical <br />OWNER FURNISHED FOOD PREP AND UTENSIL STAINLESS STEEL SINKS IN PREP AREAS. <br />M. ALL WATER HEATERS SHALL BE SET AT 115°, F. t of <br />re <br />N. SAW CUTTING AND TRENCHING ARE SHOWN ON DRAWINGS AS A SHADED AREA AROUND Engineering Consultants Incorporated <br />ALL PIPING. NOT ALL UNDER FLOOR PIPING SHOWN ON DRAWINGS HAVE A SHADED AREA 303 Federal Way Boise, ID 83705 <br />AROUND THE PIPING. Phone: 208.376,9820 Fax: 208376.9822 <br />WtVG ,' ciboise.com <br />0. PLUMBING CONTRACTOR SHALL PROVIDE PLUMBING FOR TEMPORARY <br />DEPARTMENTS/PREP AREAS, AS REQUIRED. COORDINATE WITH GENERAL CONTRACTOR <br />REGARDING TEMPORARY DEPARTMENT/PREP AREAS REQUIRED. <br />P. ALL FLOOR SINKS SHALL BE HALF EXPOSED. <br />PERMIT SET <br />
The URL can be used to link to this page
Your browser does not support the video tag.