|
r2B-
<br />(TYP)
<br />(SILVER)
<br />TPJTR29
<br />J @17'-0" 1
<br />2 A.F.F
<br />(TYP) d 4
<br />S'TIARBUCKS
<br />126
<br />0
<br />FE
<br />a EMPJ
<br />�I
<br />(SILVER)
<br />I � I
<br />SPECIALTY LIGHTING PLAN -PRODUCE AND DELI
<br />SCALE: 1 /8"=V-0"
<br />NORTH
<br />4 3.5 3514.53
<br />C4 -
<br />0 o J
<br />I X I I X I I !X I
<br />FF,
<br />Q Q Q
<br />(TYP OF 40) (TYP OF 40) (TYP OF 40)
<br />0
<br />6 7 6 7 6 7
<br />j
<br />j i
<br />(TYP) I
<br />1 ', (N)2D1-17
<br />E1.2.2
<br />C
<br />• (SILVER) .5A
<br />1 TR(fR29
<br />@11'-9.,
<br />Z 4 A.F.F
<br />(TYP)
<br />SPECIALTY LIGHTING PLAN - HSW AND DOMESTICS
<br />1� P SCALE: 1 /8"=V-0"
<br />NORTH
<br />a KEYNOTES:
<br />ALL KEYNOTES MAY NOT APPLY TO THIS SHEET.
<br />1. CONTRACTOR SHALL RUN ALL CONDUIT VERTICAL AND HORIZONTAL ALONG TRUSS & CEILING TO
<br />MINIMIZE CONDUIT EXPOSURE IN THIS AREA.
<br />2. MOUNT TRACK AND LIGHTS TO UNISTRUT. HANG UNISTRUT AT HEIGHT SPECIFIED, BY THREAD ROD AT
<br />8'-0" O.C.
<br />3. PROVIDE AND INSTALL CURRENT LIMITING DEVICE AS NOTED. EXAMPLE: HALO LC901-CB1200-X.
<br />X=COLOR. LC901 IS A END FEED, LC903 IS A CENTER FEED.
<br />4. ELECTRICAL CONTRACTOR TO COORDINATE EXACT LIGHT LOCATION WITH FRED MEYER RELAY
<br />MANAGER, KROGER PROJECT MANAGER & AIM LIGHT AT DISPLAY.
<br />5. ROUTE CIRCUITS THROUGH ENERGY MANAGEMENT SYSTEM (EMS) CONTACTOR. COORDINATE WORK
<br />WITH EMS CONTRACTOR. COORDINATE PANEL SCHEDULES AND CONTROL DOCUMENTS.
<br />6. SPORTS SECURITY CASE LIGHTS. INSTALL ONE (1) FLUORESCENT "Q" TYPE LIGHT FIXTURE IN EACH
<br />SECTION OF FLOOR FIXTURE AT THE TOP OF CASE WITH LENS FACING BACK. COORDINATE WITH FRED
<br />MEYER RELAY MANAGER,
<br />7. DISPLAY FIXTURE LIGHTING. LIGHTS SHOWN FOR REFERENCE ONLY. ELECTRICIAN TO CONNECT TO
<br />POWER SOURCE. COORDINATE WITH FRED MEYER RELAY MANAGER.
<br />8. CONNECT TO EXISTING CIRCUIT INDICATED AT NEAREST POINT OF INTERSECTION.
<br />9. INTERCEPT AND EXTEND EXISTING RACEWAY AND CONDUCTORS AND CONNECT AS SHOWN.
<br />11. FIXTURE/TRACK MOUNTED TO CEILING GRID.
<br />EXTEND THREADED ROD UP BETWEEN JOIST EXTEND THREADED ROD UP BETWEEN JOIST
<br />FLANGES AND SECURELY ATTACH TO JOIST, FLANGES AND SECURELY ATTACH TO JOIST,
<br />CONNECTION SEE DETAILS' CONNECTION,SEE DETAIL'B'
<br />SEE DETAIL'S' ' THREADED ROD'
<br />FOR TYPICAL LEADED SEE DETAIL'S' COUPLING, IF
<br />THREADED ROD ROD COUPLING, FOR TYPICAL NEEDED.
<br />CONNECTION IF NEEDED. THREADED ROD THREADED ROD.
<br />THREADED CONNECTION ROD. SEE SEE NOTES No.1
<br />NOTES No.1 & No. 4.
<br />& No. 4. ELECTRICAL
<br />SEE DETAIL'A' POWER SUPPLY
<br />FOR TYPICAL JUNCTION BOX,
<br />EYE BOLT CONNECTION SEE
<br />CONNECTION ELECTRICAL DETAIL'B'
<br />POWER SUPPLY MONOPOINT
<br />CANOPY ADAPTER
<br />TRACK INSTALLATION MONOPOINT INSTALLATION
<br />1 1l2" x 1 1/2" SEE NOTE No. 3 NYLON INSERT
<br />KINDORF B-995 LOCK NUT AND
<br />CHANNEL KINDORF B-911-3/8 WASHER
<br />OR EQUIVALENT. CHANNEL NUT OR I i
<br />EQUIVALENT.
<br />JAMB NUT
<br />AND WASHER
<br />DETAIL'A' DETAIL'B'
<br />NOTES:
<br />1. THIS DETAIL IS ASSOCIATED WITH THE INSTALLATION OF TR15, TR16, TR17, TR18 AND TR19 LED RACK LIGHT FIXTURES, HANG
<br />ELECTRIFIED TRACK FOR MULTIPLE FIXTURES OR MONOPOINT WITH THREADED ROD. THREADED ROD SHOULD BE USED TO
<br />SUPPORT ELECTRIFIED TRACK AT ALL LOCATIONS TO ELIMINATE THE CAUSE OF TRACK TO SWAY.
<br />2. FIXTURE SUPPORT AND POWER CONNECTION FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR AS REQUIRED BY
<br />GOVERNING CODES.
<br />3. INSTALL ELECTRIFIED TRACK WITH MIN 318" DIAMETER STANDARD STEEL THREADROD CONNECTED TO 1" MIN. X 1 1/2"MIN,
<br />UNISTRUT STEEL CHANNEL PAINTED TO MATCH THE WALLS, WITH 1l4" BOLT THRU FACTORY DRILLED HOLES WITH NYLON
<br />INSERT ON BOTTOM AND NYLON INSERT AND LOCK NUT ON TOP OF THE TRACK. 4' TRACK TO BE INSTALLED BY 2 POINTS OF
<br />ATTACHMENT, 8' BY 3 POINTS AND 12' BY 4 POINTS.
<br />4. MONOPOINT FIXTURE TO BE HUNG BY 3/8" THREADED ROD ATTACHED TO STEEL AND JUNCTION BOX, FOR LONGER DROPS
<br />INSTALL THREADED COUPLING AS HIGH AS POSSIBLE. ATTACH TO BOTTOM CHORD OF JOIST BY EXTENDING THREADED ROD
<br />BETWEEN JOIST FLANGES AND HOLE IN JUNCTION BOX BY ATTACHING WITH LOCK NUT WITH NYLON INSERT ON TOP AND
<br />STANDARD JAMB NUT & WASHER ON BOTTOM.
<br />5. WHERE MOUNTING THREADED ROD MISSES EXISTING STRUCTURAL STEEL, PROVIDE & SECURELY ATTACH METAL SUPPORT
<br />BETWEEN STEEL USING STEEL CHANNEL 7/8" MIN, 1" x 1" ANGLE IRON.
<br />6. LIGHT TRACK LENGTH AND HEIGHT ABOVE FLOOR VARIES PER LOCATION. REFER TO LIGHTING PLAN FOR MOUNTING HEIGHT
<br />AND LOCATIONS.
<br />('1 LED TRACK FIXTURE & MONOPOINT MOUNTING
<br />F 1 ? 7 J SCALE: N.T.S.
<br />LIGHT FIXTURE SCHEDULE
<br />EPRO
<br />ITEM #
<br />KROGER
<br />TYPE
<br />MANUFACTURER
<br />MODEL
<br />VOLT
<br />**
<br />NO. LAMPS
<br />BALLAST
<br />FIXTURE DESCRIPTION/REMARKS
<br />Where
<br />Used
<br />LAMP CATALOG NO.
<br />TOTAL
<br />WATTAGE
<br />Q
<br />COOPER
<br />OFCL-213T5-EB-120V-SW-6CP-U
<br />120
<br />2
<br />ELECTRONIC
<br />42" LOW PROFILE UNDER COUNTER, 5" DEEP X 1-1/8" HIGH, T5 LAMP
<br />6' CORD AND PLUG, PLUG INTO MULTI -OUTLET ASSEMBLY
<br />HOUSE-
<br />WARES
<br />K-0008335
<br />METALUX
<br />F13T5/CW
<br />27
<br />TR
<br />COOPER
<br />L650 SERIES TRACK
<br />120
<br />CATALOG
<br />N.A.
<br />POWER TRACK SINGLE CIRCUIT TRACK, UNIVERSAL MOUNT.
<br />SPECIRY HARDWARE, SPECIFY COLOR WH = WHITE, BK = BLACK.
<br />(L650 - 2' SECTION, L651 - 4' SECTION, L652 - 8' SECTION, L653 - 12' SECTION)
<br />TRACK
<br />HALO
<br />L650, L651, L652, L653. L908; L901, L902
<br />pg 146,147
<br />TRACK
<br />L903, L904, L1973
<br />15OW PER 2'
<br />D6cor
<br />TR29
<br />COOPER
<br />L80825NF9030P (WHITE)
<br />120
<br />1
<br />ELECTRONIC
<br />24" WIDE TRACK MOUNTED LED NARROW FLOOD
<br />8 LED, CR1 = 90, 3000K COLOR TEMPERATURE LEDS, 2500 LUMENS
<br />FINISH TO BE DETERMINED (SILVER =AH, WHITE=P OR BLACK=MB)
<br />PRDUCE
<br />TBD
<br />HALO
<br />L80825NF903OMP (BLACK)
<br />LED
<br />L80825NF9030AH (SILVER)
<br />INCLUDED
<br />35
<br />* NOTE: ELECTRICAL CONTRACTOR IS TO ORDER & INSTALL TUBE GUARDS AS DESIGNATED WITH A 'G' AT THE END OF THE FIXTURE TYPE.
<br />** APPLIED VOLTAGE FOR FIXTURE.
<br />*** 2/3 & 1/3 WIRING CONFIGURATION FOR MASTER/SLAVE
<br />FIXTURES.
<br />**** CONTRACTOR TO PROVIDE BATTERY BACK UP (IOTA 1320 OR EQUIVALENT)
<br />FIXTURE PREFIX CATEGORY LEGEND
<br />A = INDUSTRIAL
<br />H = FLUORESCENT ACCENT
<br />Q = UNDER SHELF
<br />B = FBAY
<br />J = SURFACE WRAP
<br />R = UNDER CANOPY
<br />C = RECESSED TROFFER
<br />K = SUSPENDED
<br />S = DOCK LIGHT
<br />D = STRIPS
<br />L = RECESSED CAN
<br />TR = TRACK LIGHT
<br />E = EMERGENCY UNIT
<br />LD = EXTERIOR SITE POLE MOUNT
<br />U = INTERIOR HID
<br />F = STRIPS WITH ASYMMETRIC REFLECTOR
<br />LW = EXTERIOR BUILDING WALL PACK
<br />V = SURFACE TROFFER
<br />G = RECESSED STRIP
<br />M = VAPOR TIGHT
<br />W = STAGGERED STRIP
<br />N = EXTERIOR WALL MOUNT
<br />X = EXIT SIGN/ LIGHT
<br />P = DECORATIVE
<br />PERMIT SET: 02
<br />0
<br />Architecture . Interiors
<br />Planning - Engineering
<br />Client
<br />FRED MEYER
<br />STORES INC
<br />3800 SE 22ND AVE
<br />PORTLAND, OR 97202
<br />FredUeyer.
<br />Project
<br />FRED MEYER #458
<br />MILL CREEK
<br />12906 BOTHELL-
<br />EVERETT HWY
<br />EVERETT, WA 98208
<br />Mechanical/Electrical
<br />'x,
<br />Engineering T
<br />Engineering Consultants Incorporated
<br />303 Federal Way Boise, TIC 83705
<br />Phone: 208.376,9820 Fax: 208.376.9822
<br />wwweciboise.com
<br />tXER Sri.
<br />© MACKENZIE
<br />2020 ALL RIGHTS RESERVED
<br />THESE DRAWINGS ARE THE PROPERTY OF
<br />MACKENZIE AND ARE NOT TO BE USED
<br />OR REPRODUCED IN ANY MANNER,
<br />WITHOUT PRIOR WRITTEN PERMISSION
<br />Revision Schedule
<br />Revision Delta I Issue Date
<br />SHEET TITLE:
<br />SPECIALTY
<br />LIGHTING PLAN -
<br />PRODUCE, HSW
<br />AND DETAILS
<br />DRAWN BY: ZES
<br />CHECKED BY: KSL
<br />SHEET
<br />El m2m2
<br />JOB NO.2190236.00/20VO4
<br />�17/Zoza
<br />
|