Laserfiche WebLink
r2B- <br />(TYP) <br />(SILVER) <br />TPJTR29 <br />J @17'-0" 1 <br />2 A.F.F <br />(TYP) d 4 <br />S'TIARBUCKS <br />126 <br />0 <br />FE <br />a EMPJ <br />�I <br />(SILVER) <br />I � I <br />SPECIALTY LIGHTING PLAN -PRODUCE AND DELI <br />SCALE: 1 /8"=V-0" <br />NORTH <br />4 3.5 3514.53 <br />C4 - <br />0 o J <br />I X I I X I I !X I <br />FF, <br />Q Q Q <br />(TYP OF 40) (TYP OF 40) (TYP OF 40) <br />0 <br />6 7 6 7 6 7 <br />j <br />j i <br />(TYP) I <br />1 ', (N)2D1-17 <br />E1.2.2 <br />C <br />• (SILVER) .5A <br />1 TR(fR29 <br />@11'-9., <br />Z 4 A.F.F <br />(TYP) <br />SPECIALTY LIGHTING PLAN - HSW AND DOMESTICS <br />1� P SCALE: 1 /8"=V-0" <br />NORTH <br />a KEYNOTES: <br />ALL KEYNOTES MAY NOT APPLY TO THIS SHEET. <br />1. CONTRACTOR SHALL RUN ALL CONDUIT VERTICAL AND HORIZONTAL ALONG TRUSS & CEILING TO <br />MINIMIZE CONDUIT EXPOSURE IN THIS AREA. <br />2. MOUNT TRACK AND LIGHTS TO UNISTRUT. HANG UNISTRUT AT HEIGHT SPECIFIED, BY THREAD ROD AT <br />8'-0" O.C. <br />3. PROVIDE AND INSTALL CURRENT LIMITING DEVICE AS NOTED. EXAMPLE: HALO LC901-CB1200-X. <br />X=COLOR. LC901 IS A END FEED, LC903 IS A CENTER FEED. <br />4. ELECTRICAL CONTRACTOR TO COORDINATE EXACT LIGHT LOCATION WITH FRED MEYER RELAY <br />MANAGER, KROGER PROJECT MANAGER & AIM LIGHT AT DISPLAY. <br />5. ROUTE CIRCUITS THROUGH ENERGY MANAGEMENT SYSTEM (EMS) CONTACTOR. COORDINATE WORK <br />WITH EMS CONTRACTOR. COORDINATE PANEL SCHEDULES AND CONTROL DOCUMENTS. <br />6. SPORTS SECURITY CASE LIGHTS. INSTALL ONE (1) FLUORESCENT "Q" TYPE LIGHT FIXTURE IN EACH <br />SECTION OF FLOOR FIXTURE AT THE TOP OF CASE WITH LENS FACING BACK. COORDINATE WITH FRED <br />MEYER RELAY MANAGER, <br />7. DISPLAY FIXTURE LIGHTING. LIGHTS SHOWN FOR REFERENCE ONLY. ELECTRICIAN TO CONNECT TO <br />POWER SOURCE. COORDINATE WITH FRED MEYER RELAY MANAGER. <br />8. CONNECT TO EXISTING CIRCUIT INDICATED AT NEAREST POINT OF INTERSECTION. <br />9. INTERCEPT AND EXTEND EXISTING RACEWAY AND CONDUCTORS AND CONNECT AS SHOWN. <br />11. FIXTURE/TRACK MOUNTED TO CEILING GRID. <br />EXTEND THREADED ROD UP BETWEEN JOIST EXTEND THREADED ROD UP BETWEEN JOIST <br />FLANGES AND SECURELY ATTACH TO JOIST, FLANGES AND SECURELY ATTACH TO JOIST, <br />CONNECTION SEE DETAILS' CONNECTION,SEE DETAIL'B' <br />SEE DETAIL'S' ' THREADED ROD' <br />FOR TYPICAL LEADED SEE DETAIL'S' COUPLING, IF <br />THREADED ROD ROD COUPLING, FOR TYPICAL NEEDED. <br />CONNECTION IF NEEDED. THREADED ROD THREADED ROD. <br />THREADED CONNECTION ROD. SEE SEE NOTES No.1 <br />NOTES No.1 & No. 4. <br />& No. 4. ELECTRICAL <br />SEE DETAIL'A' POWER SUPPLY <br />FOR TYPICAL JUNCTION BOX, <br />EYE BOLT CONNECTION SEE <br />CONNECTION ELECTRICAL DETAIL'B' <br />POWER SUPPLY MONOPOINT <br />CANOPY ADAPTER <br />TRACK INSTALLATION MONOPOINT INSTALLATION <br />1 1l2" x 1 1/2" SEE NOTE No. 3 NYLON INSERT <br />KINDORF B-995 LOCK NUT AND <br />CHANNEL KINDORF B-911-3/8 WASHER <br />OR EQUIVALENT. CHANNEL NUT OR I i <br />EQUIVALENT. <br />JAMB NUT <br />AND WASHER <br />DETAIL'A' DETAIL'B' <br />NOTES: <br />1. THIS DETAIL IS ASSOCIATED WITH THE INSTALLATION OF TR15, TR16, TR17, TR18 AND TR19 LED RACK LIGHT FIXTURES, HANG <br />ELECTRIFIED TRACK FOR MULTIPLE FIXTURES OR MONOPOINT WITH THREADED ROD. THREADED ROD SHOULD BE USED TO <br />SUPPORT ELECTRIFIED TRACK AT ALL LOCATIONS TO ELIMINATE THE CAUSE OF TRACK TO SWAY. <br />2. FIXTURE SUPPORT AND POWER CONNECTION FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR AS REQUIRED BY <br />GOVERNING CODES. <br />3. INSTALL ELECTRIFIED TRACK WITH MIN 318" DIAMETER STANDARD STEEL THREADROD CONNECTED TO 1" MIN. X 1 1/2"MIN, <br />UNISTRUT STEEL CHANNEL PAINTED TO MATCH THE WALLS, WITH 1l4" BOLT THRU FACTORY DRILLED HOLES WITH NYLON <br />INSERT ON BOTTOM AND NYLON INSERT AND LOCK NUT ON TOP OF THE TRACK. 4' TRACK TO BE INSTALLED BY 2 POINTS OF <br />ATTACHMENT, 8' BY 3 POINTS AND 12' BY 4 POINTS. <br />4. MONOPOINT FIXTURE TO BE HUNG BY 3/8" THREADED ROD ATTACHED TO STEEL AND JUNCTION BOX, FOR LONGER DROPS <br />INSTALL THREADED COUPLING AS HIGH AS POSSIBLE. ATTACH TO BOTTOM CHORD OF JOIST BY EXTENDING THREADED ROD <br />BETWEEN JOIST FLANGES AND HOLE IN JUNCTION BOX BY ATTACHING WITH LOCK NUT WITH NYLON INSERT ON TOP AND <br />STANDARD JAMB NUT & WASHER ON BOTTOM. <br />5. WHERE MOUNTING THREADED ROD MISSES EXISTING STRUCTURAL STEEL, PROVIDE & SECURELY ATTACH METAL SUPPORT <br />BETWEEN STEEL USING STEEL CHANNEL 7/8" MIN, 1" x 1" ANGLE IRON. <br />6. LIGHT TRACK LENGTH AND HEIGHT ABOVE FLOOR VARIES PER LOCATION. REFER TO LIGHTING PLAN FOR MOUNTING HEIGHT <br />AND LOCATIONS. <br />('1 LED TRACK FIXTURE & MONOPOINT MOUNTING <br />F 1 ? 7 J SCALE: N.T.S. <br />LIGHT FIXTURE SCHEDULE <br />EPRO <br />ITEM # <br />KROGER <br />TYPE <br />MANUFACTURER <br />MODEL <br />VOLT <br />** <br />NO. LAMPS <br />BALLAST <br />FIXTURE DESCRIPTION/REMARKS <br />Where <br />Used <br />LAMP CATALOG NO. <br />TOTAL <br />WATTAGE <br />Q <br />COOPER <br />OFCL-213T5-EB-120V-SW-6CP-U <br />120 <br />2 <br />ELECTRONIC <br />42" LOW PROFILE UNDER COUNTER, 5" DEEP X 1-1/8" HIGH, T5 LAMP <br />6' CORD AND PLUG, PLUG INTO MULTI -OUTLET ASSEMBLY <br />HOUSE- <br />WARES <br />K-0008335 <br />METALUX <br />F13T5/CW <br />27 <br />TR <br />COOPER <br />L650 SERIES TRACK <br />120 <br />CATALOG <br />N.A. <br />POWER TRACK SINGLE CIRCUIT TRACK, UNIVERSAL MOUNT. <br />SPECIRY HARDWARE, SPECIFY COLOR WH = WHITE, BK = BLACK. <br />(L650 - 2' SECTION, L651 - 4' SECTION, L652 - 8' SECTION, L653 - 12' SECTION) <br />TRACK <br />HALO <br />L650, L651, L652, L653. L908; L901, L902 <br />pg 146,147 <br />TRACK <br />L903, L904, L1973 <br />15OW PER 2' <br />D6cor <br />TR29 <br />COOPER <br />L80825NF9030P (WHITE) <br />120 <br />1 <br />ELECTRONIC <br />24" WIDE TRACK MOUNTED LED NARROW FLOOD <br />8 LED, CR1 = 90, 3000K COLOR TEMPERATURE LEDS, 2500 LUMENS <br />FINISH TO BE DETERMINED (SILVER =AH, WHITE=P OR BLACK=MB) <br />PRDUCE <br />TBD <br />HALO <br />L80825NF903OMP (BLACK) <br />LED <br />L80825NF9030AH (SILVER) <br />INCLUDED <br />35 <br />* NOTE: ELECTRICAL CONTRACTOR IS TO ORDER & INSTALL TUBE GUARDS AS DESIGNATED WITH A 'G' AT THE END OF THE FIXTURE TYPE. <br />** APPLIED VOLTAGE FOR FIXTURE. <br />*** 2/3 & 1/3 WIRING CONFIGURATION FOR MASTER/SLAVE <br />FIXTURES. <br />**** CONTRACTOR TO PROVIDE BATTERY BACK UP (IOTA 1320 OR EQUIVALENT) <br />FIXTURE PREFIX CATEGORY LEGEND <br />A = INDUSTRIAL <br />H = FLUORESCENT ACCENT <br />Q = UNDER SHELF <br />B = FBAY <br />J = SURFACE WRAP <br />R = UNDER CANOPY <br />C = RECESSED TROFFER <br />K = SUSPENDED <br />S = DOCK LIGHT <br />D = STRIPS <br />L = RECESSED CAN <br />TR = TRACK LIGHT <br />E = EMERGENCY UNIT <br />LD = EXTERIOR SITE POLE MOUNT <br />U = INTERIOR HID <br />F = STRIPS WITH ASYMMETRIC REFLECTOR <br />LW = EXTERIOR BUILDING WALL PACK <br />V = SURFACE TROFFER <br />G = RECESSED STRIP <br />M = VAPOR TIGHT <br />W = STAGGERED STRIP <br />N = EXTERIOR WALL MOUNT <br />X = EXIT SIGN/ LIGHT <br />P = DECORATIVE <br />PERMIT SET: 02 <br />0 <br />Architecture . Interiors <br />Planning - Engineering <br />Client <br />FRED MEYER <br />STORES INC <br />3800 SE 22ND AVE <br />PORTLAND, OR 97202 <br />FredUeyer. <br />Project <br />FRED MEYER #458 <br />MILL CREEK <br />12906 BOTHELL- <br />EVERETT HWY <br />EVERETT, WA 98208 <br />Mechanical/Electrical <br />'x, <br />Engineering T <br />Engineering Consultants Incorporated <br />303 Federal Way Boise, TIC 83705 <br />Phone: 208.376,9820 Fax: 208.376.9822 <br />wwweciboise.com <br />tXER Sri. <br />© MACKENZIE <br />2020 ALL RIGHTS RESERVED <br />THESE DRAWINGS ARE THE PROPERTY OF <br />MACKENZIE AND ARE NOT TO BE USED <br />OR REPRODUCED IN ANY MANNER, <br />WITHOUT PRIOR WRITTEN PERMISSION <br />Revision Schedule <br />Revision Delta I Issue Date <br />SHEET TITLE: <br />SPECIALTY <br />LIGHTING PLAN - <br />PRODUCE, HSW <br />AND DETAILS <br />DRAWN BY: ZES <br />CHECKED BY: KSL <br />SHEET <br />El m2m2 <br />JOB NO.2190236.00/20VO4 <br />�17/Zoza <br />