My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12906 19TH AVE SE 2020 Plans 2023-02-24
>
Address Records
>
19TH AVE SE
>
12906
>
Plans
>
12906 19TH AVE SE 2020 Plans 2023-02-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2023 8:32:55 AM
Creation date
2/23/2023 4:09:06 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12906
Permit
B2004-018
Year
2020
Notes
WITHIN THE WALLS REMODEL OF EXTG STORE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
13 12.4� 12 11.51 11 10.6 0 �� �I 1 9.5 9 8.5 8 7.6 7 6.4 6 5.5 5 4.5 4 3.5 3 2 1.5 1 <br />594' - 0" .. <br />' J Al.1 111 = 201-011 <br />GENERAL NOTES <br />A. <br />REFER TO ASD/GISD REFERENCE PLAN A5.0 FOR ALL APPLICABLE ASD/GISD LOCATIONS. <br />M. <br />PROVIDE BLOCKING IN ALL PARTITIONS FOR ALL MOUNTED ITEMS, INCLUDING BUT NOT LIMITED TO: FIRE <br />B. <br />FIXTURES SHOWN FOR REFERENCE ONLY, SEE FIXTURE PLAN FOR FIXTURE LAYOUT. <br />EXTINGUISHERS, GATES, HOSE RACKS, MOP/BROOM RACKS, POT RACKS, EQUIPMENT RACKS, TOILET PARTITIONS, <br />C. <br />DETAIL REFERENCES APPLY TO ALL INSTANCES WHERE THE SAME CONDITIONS OCCUR. <br />BASCART DOOR OPERATORS, WALL MOUNTED DESKS, WALL MOUNTED COMPUTER WORK STATIONS, WALL MOUNTED <br />D. <br />FOR WALL TYPE INFORMATION SEE SHEET A3.2 & A3.2.1. <br />SHELVING, WALL MOUNTED CABINETRY, FLAT -SCREEN WALL MOUNTED TELEVISIONS, DECOR/SIGNAGE, TYP. METAL <br />E. <br />FOR MATERIALS AND FINISHES SEE FINISH SCHEDULE, INTERIOR ELEVATIONS AND SPECIFICATIONS. VERIFY ALL FINISHES <br />STUD WALLS IN PREP AREA ROOMS WITH SHELVING TO FOLLOW BLOCKING PATTERN AS PROVIDED AT PREFAB <br />WITH SIGNAGE AND DECOR DRAWINGS. <br />INSULATED WALLS, COORD AS REQ'D. <br />F. <br />DIMENSIONS ARE GIVEN TO COLUMN LINES, FACE OF STUD, FACE OF CMU, OR ROUGH OPENING UNLESS NOTED <br />N. <br />ALL NEW GYPSUM BOARD ON INTERIOR PARTITIONS AND EXTERIOR WALLS BEHIND CASES AND SHELVING TO STOP AT <br />OTHERWISE. ALIGN FINISHES WHERE INDICATED. DIMENSIONS ARE MARKED "CLR" ARE FROM FINISH SURFACE TO FINISH <br />6'-0" AFF U.N.O. SEE PLANS AND FIXTURE PLAN FOR FURTHER INFO. <br />SURFACE AND SUPERCEDE OTHER DIMENSIONS. <br />O. <br />PROVIDE EXPANSION JOINTS AND CONTROL JOINTS AS REQUIRED PER DETAILS 11 AND 14 ON SHEET A1.3.1. <br />G. <br />DIMENSIONS ADJACENT TO LATCH SIDE OF DOORS INDICATE ACCESSIBLE CLEARANCES REQUIRED BETWEEN THE CLEAR <br />P. <br />ROUTE DROPS FOR REFRIGERATED CASES AS INDICATED ON GISD AND REFRIGERATION DRAWINGS. <br />DOOR OPENING AND THE ADJACENT FINISH. DOORS NOT DIMENSIONED ARE TO BE LOCATED 4" FROM FACE OF WALL TO <br />Q. <br />PROVIDE INSULATION/PADDING AT ALL EXPOSED PIPING UNDER SINKS PER CODE. <br />OUTSIDE EDGE OF JAMB TYPICAL. <br />R. <br />PROVIDE STAINLESS STEEL CLOSURE AT TILE TERMINATION AROUND FREEZER/COOLER DOORS, SEE ENLARGED PLANS. <br />H. <br />CONTRACTOR TO VERIFY AND CONFIRM ALL DIMENSIONS AND LAYOUT INFORMATION. NOTIFY ARCHITECT OF AN <br />S. <br />PROVIDE REFRIGERATED CASE CORNER GUARDS AND BOLLARDS AS REQ'D PER ASD, COORDINATE LOCATIONS W/ <br />CONFLICTS OR DISCREPANCIES PRIOR TO CONSTRUCTION. DO NOT SCALE DRAWINGS. <br />FIXTURE PLAN. <br />I. <br />MAINTAIN EXITS AS REQ'D BY AUTHORITY HAVING JURISDICTION DURING ALL PHASES OF CONSTRUCTION. <br />T. <br />PROVIDE SS SPLASH GUARDS AT HAND WASH SINKS IN PREP AREAS. <br />J. <br />PROVIDE TEMPORARY CONSTRUCTION BARRIERS AT ALL PHASES OF CONSTRUCTION PER ASD. SEE OWNER PHASING <br />U. <br />REFER TO SHEET A6.3 FOR COLUMN FINISH NOTES. <br />PLAN AND SCHEDULE. <br />V. <br />CLEAN SPRINKLER HEADS, MODIFY SYSTEM AS NEEDED TO MEET KROGER STANDARDS. <br />K. <br />CONTRACTOR TO PATCH AND REPAIR ALL WALLS WHERE REQUIRED DUE TO DEMO, NEW WORK, OR AS REQUIRED TO <br />REPAIR (E) DAMAGED CONDITIONS. <br />L. <br />WALL CONSTRUCTION AND FINISHES ADJACENT TO DOORS AND STOREFRONT CONTINUE OVER TOP OF DOOR AND/OR <br />STOREFRONT UNLESS NOTED OR DETAILED OTHERWISE.REFER TO ASD/GISD REFERENCE PLAN A5.0 FOR ALL <br />APPLICABLE ASD/GISD LOCATIONS. <br />KEYNOTES <br />09-02 PROVIDE WOOD STRIPPING BEHIND FIXTURES AT ALL NEW AND REVISED FIXTURE HEIGHTS, SEE DETAIL <br />7/A6.2. ADD GYP ABOVE FIXTURE AS REQUIRED. <br />09-11 STEAM CLEAN ALL RESTROOMS <br />09-13 REPAIR CEILING & INFILL CEILING GRID AS NEEDED <br />09-14 COORDINATE LOCATION WITH KPM TO MINIMIZE IMPACT TO CEILING LIGHTING, HVAC, SPRINKLERS. <br />10-01 (N) ELECTRIC HAND DRYER <br />Architecture I. Interiors <br />Planning N Engineering <br />Portland, OR <br />503.224.9560 <br />Vancouver, WA <br />360.695.7879 <br />Seattle, WA <br />206.749.9993 <br />www.mcknze.com <br />MACKENZIE <br />DESIGN DRIVEN I CLIENT FOCUSED <br />Client <br />FRED MEYER <br />STORES INC <br />3800 SE 22ND AVE <br />PORTLAND, OR 97202 <br />F------------ <br />i��d <br />Project <br />FRED MEYER #458 <br />MILL CREEK <br />12906 BOTHELL- <br />EVERETT HWY <br />EVERETT, WA 98208 <br />Mechanical/Electrical <br />t <br />301 REGISTERED <br />ARC T CT <br />TE Y ALLEN KRAUSE <br />STATE OF WASHINGTON <br />© MACKENZIE <br />2020 ALL RIGHTS RESERVED <br />THESE DRAWINGS ARE THE PROPERTY OF <br />MACKENZIE AND ARE NOT TO BE USED <br />OR REPRODUCED IN ANY MANNER, <br />WITHOUT PRIOR WRITTEN PERMISSION <br />-------------- <br />Revision Schedule <br />Revision Delta Issue Date <br />SHEET TITLE: <br />GROUND <br />FLOOR PLAN <br />LEGEND <br />EXISTING NEW <br />NO WORK IN THIS AREA, EXISTING EXTERIOR CMU WALL W/ FURRING <br />TENANT TO REMAIN, CONTRACTOR <br />TO ENSURE WORK DOES NOT INTERIOR PARTITION/FURRING <br />DISTURB TENANT. <br />LOW WALL PARTITION <br />-_ EXTERIOR WALUINTERIOR <br />PARTITION/WALK IN BOX WALULOW WALK-IN BOX WALL <br />WALUFURRING <br />STOREFRONT STOREFRONT <br />DRAWN BY: LEM <br />- _ - FASCIA = _ _ _ = FASCIA ABOVE <br />- SOFFIT/ROOF/OVERHANG ABOVE CHECKED BY: JGV <br />SOFFIT/ROOF/OVERHANG ABOVE <br />CHAIN LINK FENCE & GATES _L CHAIN LINK FENCE & GATES SHEET <br />FIXTURES SHOWN FOR REFERENCE <br />ONLY, SEE il.1 FIXTURE PLAN FIXTURES SHOWN FOR REFERENCE <br />ONLY, SEE i1,1 FIXTURE PLAN <br />Al <br />■` <br />STY 01F 'VRE <br />JOB No. 2190236.00 <br />PERMIT SET: 02.17.20 <br />C:1Userslsrf1DocumentslRevit ProjectsXARCHITECTURAL1219023600 - FM 458 Mill Creek\236-FM MILL CREEK-L.rvt 2/17/202011:52:47 AM 1" = 20'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.