Laserfiche WebLink
13 12.4� 12 11.51 11 10.6 0 �� �I 1 9.5 9 8.5 8 7.6 7 6.4 6 5.5 5 4.5 4 3.5 3 2 1.5 1 <br />594' - 0" .. <br />' J Al.1 111 = 201-011 <br />GENERAL NOTES <br />A. <br />REFER TO ASD/GISD REFERENCE PLAN A5.0 FOR ALL APPLICABLE ASD/GISD LOCATIONS. <br />M. <br />PROVIDE BLOCKING IN ALL PARTITIONS FOR ALL MOUNTED ITEMS, INCLUDING BUT NOT LIMITED TO: FIRE <br />B. <br />FIXTURES SHOWN FOR REFERENCE ONLY, SEE FIXTURE PLAN FOR FIXTURE LAYOUT. <br />EXTINGUISHERS, GATES, HOSE RACKS, MOP/BROOM RACKS, POT RACKS, EQUIPMENT RACKS, TOILET PARTITIONS, <br />C. <br />DETAIL REFERENCES APPLY TO ALL INSTANCES WHERE THE SAME CONDITIONS OCCUR. <br />BASCART DOOR OPERATORS, WALL MOUNTED DESKS, WALL MOUNTED COMPUTER WORK STATIONS, WALL MOUNTED <br />D. <br />FOR WALL TYPE INFORMATION SEE SHEET A3.2 & A3.2.1. <br />SHELVING, WALL MOUNTED CABINETRY, FLAT -SCREEN WALL MOUNTED TELEVISIONS, DECOR/SIGNAGE, TYP. METAL <br />E. <br />FOR MATERIALS AND FINISHES SEE FINISH SCHEDULE, INTERIOR ELEVATIONS AND SPECIFICATIONS. VERIFY ALL FINISHES <br />STUD WALLS IN PREP AREA ROOMS WITH SHELVING TO FOLLOW BLOCKING PATTERN AS PROVIDED AT PREFAB <br />WITH SIGNAGE AND DECOR DRAWINGS. <br />INSULATED WALLS, COORD AS REQ'D. <br />F. <br />DIMENSIONS ARE GIVEN TO COLUMN LINES, FACE OF STUD, FACE OF CMU, OR ROUGH OPENING UNLESS NOTED <br />N. <br />ALL NEW GYPSUM BOARD ON INTERIOR PARTITIONS AND EXTERIOR WALLS BEHIND CASES AND SHELVING TO STOP AT <br />OTHERWISE. ALIGN FINISHES WHERE INDICATED. DIMENSIONS ARE MARKED "CLR" ARE FROM FINISH SURFACE TO FINISH <br />6'-0" AFF U.N.O. SEE PLANS AND FIXTURE PLAN FOR FURTHER INFO. <br />SURFACE AND SUPERCEDE OTHER DIMENSIONS. <br />O. <br />PROVIDE EXPANSION JOINTS AND CONTROL JOINTS AS REQUIRED PER DETAILS 11 AND 14 ON SHEET A1.3.1. <br />G. <br />DIMENSIONS ADJACENT TO LATCH SIDE OF DOORS INDICATE ACCESSIBLE CLEARANCES REQUIRED BETWEEN THE CLEAR <br />P. <br />ROUTE DROPS FOR REFRIGERATED CASES AS INDICATED ON GISD AND REFRIGERATION DRAWINGS. <br />DOOR OPENING AND THE ADJACENT FINISH. DOORS NOT DIMENSIONED ARE TO BE LOCATED 4" FROM FACE OF WALL TO <br />Q. <br />PROVIDE INSULATION/PADDING AT ALL EXPOSED PIPING UNDER SINKS PER CODE. <br />OUTSIDE EDGE OF JAMB TYPICAL. <br />R. <br />PROVIDE STAINLESS STEEL CLOSURE AT TILE TERMINATION AROUND FREEZER/COOLER DOORS, SEE ENLARGED PLANS. <br />H. <br />CONTRACTOR TO VERIFY AND CONFIRM ALL DIMENSIONS AND LAYOUT INFORMATION. NOTIFY ARCHITECT OF AN <br />S. <br />PROVIDE REFRIGERATED CASE CORNER GUARDS AND BOLLARDS AS REQ'D PER ASD, COORDINATE LOCATIONS W/ <br />CONFLICTS OR DISCREPANCIES PRIOR TO CONSTRUCTION. DO NOT SCALE DRAWINGS. <br />FIXTURE PLAN. <br />I. <br />MAINTAIN EXITS AS REQ'D BY AUTHORITY HAVING JURISDICTION DURING ALL PHASES OF CONSTRUCTION. <br />T. <br />PROVIDE SS SPLASH GUARDS AT HAND WASH SINKS IN PREP AREAS. <br />J. <br />PROVIDE TEMPORARY CONSTRUCTION BARRIERS AT ALL PHASES OF CONSTRUCTION PER ASD. SEE OWNER PHASING <br />U. <br />REFER TO SHEET A6.3 FOR COLUMN FINISH NOTES. <br />PLAN AND SCHEDULE. <br />V. <br />CLEAN SPRINKLER HEADS, MODIFY SYSTEM AS NEEDED TO MEET KROGER STANDARDS. <br />K. <br />CONTRACTOR TO PATCH AND REPAIR ALL WALLS WHERE REQUIRED DUE TO DEMO, NEW WORK, OR AS REQUIRED TO <br />REPAIR (E) DAMAGED CONDITIONS. <br />L. <br />WALL CONSTRUCTION AND FINISHES ADJACENT TO DOORS AND STOREFRONT CONTINUE OVER TOP OF DOOR AND/OR <br />STOREFRONT UNLESS NOTED OR DETAILED OTHERWISE.REFER TO ASD/GISD REFERENCE PLAN A5.0 FOR ALL <br />APPLICABLE ASD/GISD LOCATIONS. <br />KEYNOTES <br />09-02 PROVIDE WOOD STRIPPING BEHIND FIXTURES AT ALL NEW AND REVISED FIXTURE HEIGHTS, SEE DETAIL <br />7/A6.2. ADD GYP ABOVE FIXTURE AS REQUIRED. <br />09-11 STEAM CLEAN ALL RESTROOMS <br />09-13 REPAIR CEILING & INFILL CEILING GRID AS NEEDED <br />09-14 COORDINATE LOCATION WITH KPM TO MINIMIZE IMPACT TO CEILING LIGHTING, HVAC, SPRINKLERS. <br />10-01 (N) ELECTRIC HAND DRYER <br />Architecture I. Interiors <br />Planning N Engineering <br />Portland, OR <br />503.224.9560 <br />Vancouver, WA <br />360.695.7879 <br />Seattle, WA <br />206.749.9993 <br />www.mcknze.com <br />MACKENZIE <br />DESIGN DRIVEN I CLIENT FOCUSED <br />Client <br />FRED MEYER <br />STORES INC <br />3800 SE 22ND AVE <br />PORTLAND, OR 97202 <br />F------------ <br />i��d <br />Project <br />FRED MEYER #458 <br />MILL CREEK <br />12906 BOTHELL- <br />EVERETT HWY <br />EVERETT, WA 98208 <br />Mechanical/Electrical <br />t <br />301 REGISTERED <br />ARC T CT <br />TE Y ALLEN KRAUSE <br />STATE OF WASHINGTON <br />© MACKENZIE <br />2020 ALL RIGHTS RESERVED <br />THESE DRAWINGS ARE THE PROPERTY OF <br />MACKENZIE AND ARE NOT TO BE USED <br />OR REPRODUCED IN ANY MANNER, <br />WITHOUT PRIOR WRITTEN PERMISSION <br />-------------- <br />Revision Schedule <br />Revision Delta Issue Date <br />SHEET TITLE: <br />GROUND <br />FLOOR PLAN <br />LEGEND <br />EXISTING NEW <br />NO WORK IN THIS AREA, EXISTING EXTERIOR CMU WALL W/ FURRING <br />TENANT TO REMAIN, CONTRACTOR <br />TO ENSURE WORK DOES NOT INTERIOR PARTITION/FURRING <br />DISTURB TENANT. <br />LOW WALL PARTITION <br />-_ EXTERIOR WALUINTERIOR <br />PARTITION/WALK IN BOX WALULOW WALK-IN BOX WALL <br />WALUFURRING <br />STOREFRONT STOREFRONT <br />DRAWN BY: LEM <br />- _ - FASCIA = _ _ _ = FASCIA ABOVE <br />- SOFFIT/ROOF/OVERHANG ABOVE CHECKED BY: JGV <br />SOFFIT/ROOF/OVERHANG ABOVE <br />CHAIN LINK FENCE & GATES _L CHAIN LINK FENCE & GATES SHEET <br />FIXTURES SHOWN FOR REFERENCE <br />ONLY, SEE il.1 FIXTURE PLAN FIXTURES SHOWN FOR REFERENCE <br />ONLY, SEE i1,1 FIXTURE PLAN <br />Al <br />■` <br />STY 01F 'VRE <br />JOB No. 2190236.00 <br />PERMIT SET: 02.17.20 <br />C:1Userslsrf1DocumentslRevit ProjectsXARCHITECTURAL1219023600 - FM 458 Mill Creek\236-FM MILL CREEK-L.rvt 2/17/202011:52:47 AM 1" = 20'-0" <br />