Laserfiche WebLink
GE-NERAL NOTES <br />'Nomigiiam <br />CODE <br />The following codes and classifications are applicable to this project and are to be enforced: <br />2015 International Building Code (Structural for Residential) <br />2916 International Residentiai Code (Ordinance) <br />2015 Washington State Energy Code and Ventilation Code <br />(Or adopted City of Seattle versions of these same codes.) <br />BUILDING, <br />Construction Type: V Seismic Zone: D2 <br />Occupancy Group: Wind Speed: 36 MRFI/3sec. 120 MPH Gust <br />Fire Zone: 3 Exposure Category: B Kit: <br />LOADING: Floor Live Load: 40psf Dead Load: 10psf <br />Roof Live Load: 26psf Dead Load: 16 sf <br />Stairs Live Load: 100psf Dead Load: 10psf <br />Exterior and Interior Walls: Dead Load: 35plf <br />Contractor shall verify all notes, dimensions and conditions prior to construction. During demolition <br />and construction the Contractor shall provide temporary bracing for support and stability until all <br />positive connections have been installed. The Contractor shall report all discrepancies to the <br />Designer when they are noted. Written dimensions take precedence over scaled drawings. <br />SITE WORK <br />has performed a soils investigation and report, the <br />Unless a state approved �eotechnica Engineerp g p, <br />foundation will be designed based on the assumption that the average soil bearing is 2000psf. <br />Exterior footings shall be a minimum 1259 below finished grade for one-story structures or 18" below <br />finished grade for multiple -story structures on undisturbed soil. Footing drains, if required, are to be <br />tied to existing or new systems, Mono -pour slabs with footings shall be a minimum 12" below finished <br />grade. Foundation vents shall not interfere with bearing points or be within 3" of lateral holdowns. <br />Finish grade shall be a rain. 6" below the top of foundation. <br />CONCRETE, <br />Class and Use F'C Slump Min. Sacks/cy <br />A. Footings and foundations 2500 3-4 Y2 <br />B. Slabs On grade 2600 3-4 5 Y2 <br />Air entraining agent (3% to 6%) t0 be Used in all concrete flat work exposed to the weather, <br />Retarding agents may be used, but must be installed by professional concrete provider. Concrete <br />mix design and water®to-cement ratio to be in accordance to the IBC. <br />REINFORCING STEEL and COVER <br />All steel reinforcing to be ASTM A615 Grade, 40. All special reinforcing steel details to be approved <br />by a'professional engineer. All splices are to be lapped 30 diameters. No splices to occur at <br />locations of tension. <br />Cover: 3" Concrete cast against and perm- anently, exposed to earth <br />1 1/2" Concrete exposed to weather or tem, porarl'ly t0 earth <br />1 1/2" Beams and columns not exposed to earth Or weather <br />%" dabs or walls not exposed to earth or weather <br />All structural framing and nailing are to conform to the requirements in the IBC or IRC. All wood in <br />contact with concrete to be pressure treated. All structural wood exposed to the weather to be <br />pressure treated. Wood bearing against or within 1" of masonry to be pressure treated. Solid 2x <br />blocking shall be installed at ends and at all support points of all joists and rafters. Also, solid 2x - <br />blocking or approved bridging shall be installed at the mid -span of ail joists spanning more than 10'- <br />0". Typical anchor bolts, tying sill plate to foundation, shall be minimum 6/8" diameter and embedded <br />into the foundation minimum " at 4'®0"oc and 12" from all corners and plate separations. Bolt heads <br />and nuts bearing against wood to have 3"x3"x1/4" square washers. All metal framing anchors, <br />connectors and hangers called Out on drawings to be Simpson Strong -Tie Connectors or designer <br />approved equal. <br />Minimum woad -to -earth clearances: 699 Any untreated wood to earth <br />12" Craw{space floor bears to earth <br />1" Crawlspace floor joists to earth <br />LUMBER STRENGTH (units in osi <br />FV Fb L <br />Studs: Hem -Fir #3 76 600 1200K <br />Stud grade 75 675 1200K <br />Joists & Rafters: Hem -Fir #2 (2x10) (2x12) 75 350 1300K <br />Beams &pleaders: 4x Doug -Fir #2X1 96 375/1000 160OK/1700K <br />6x Doug -Fir 2/ 1 35 375/1350 1300K/1600K <br />Clulam Beams: Doug -Fir Larch 24F-V4 190 2400 1 00K <br />Micro -Lam: LVL 1.9 E 290 2900 1900K <br />Loading: <br />Roof 16psf Dead Load + 26psf Live Load o 40psf <br />Floor 10psf Dead Load + 40psf Live Load m 60psf <br />Ceiling 5psf Dead Load + 10psf Live Load 16psf <br />Deck 10psf mead Load psf Live Load psf <br />Interior Partition e 30pif <br />Exterior Partition 90plf <br />PLYWOOD <br />Plywood wall and roof sheathing shall e 1/2" CD or 7/16" OSB, unless otherwise specified. <br />y g p <br />Minimum nailing shall be 3d @ 6"oc on all panel edges and 12"oc in the field. The span index shall <br />be 24/0. Plywood subflooring shall be 1/99 CDX or 11/16" OSD tong ue=and=grove, unless otherwise <br />specified. Minimum nailing shall be 10d @ 6"oc on pane{ edges bearing on supports and 12"oc in the <br />field. The span index shall be 40/20. Roof and floor sheathing should be staggered a minimum 24". <br />WOOD TRUSSES <br />All roof and floor trusses shall be designed by a State approved engineer and fabricated only from the <br />approved designs. The trusses, are to be stamped by the manufacturer or by an approved quality <br />control agency. All truss designs are to be submitted to the. Building Official for approval prior t0 <br />fabrication and a copy of the approved designs to go to the Designer. Nonbearing walls shall not be <br />tied directly to the roof truss bottom -hord unless with an approved connector. All truss -to -truss metal <br />connections are to be specified by the designing engineer. The roof trusses shall be tied into the <br />framework and the supporting galls so as to form an integral art of the whole structure, Temporary <br />pp 9 g C� <br />diagonal and sway bracing shall be used until all required bracing and roof sheathing is installed, <br />FIREPLACES <br />Masonry fireplaces laces and chirnne s are to e constructed to conform to all applicable ortions of the <br />p yp <br />IBC, IFC and International Mechanical Code. Chimneys shall support their Own weight unless <br />specifically designed to support additional loads. All fireplaces are to be provided with tightly fitting <br />flue dampers and Operated with a readily accessible manual Or approved automatic control, An <br />Outside source, of combustion air is t0 be provided with a minimum 10 square inch dint. <br />Prefabricated fireplaces, chimneys and related components to bear UL or ICBO seals of approval and <br />installed per manufacturer's specifications. Masonry hearths are to extend 20" in front of and 12" <br />beyond each side of the fireplace mouth. All fireplaces are to be provided with tight fitting tempered <br />glass or metal doors. <br />INSULATION & MOISTURE PROTECTION <br />LIGHTING, <br />A minimum of 75% of lamps in permanently installed lighting fixtures shall be high -efficacy lamps. <br />0Pi'i0N <br />DESCRIPTION <br />�_.Eb1i() <br />EFFICIENT BUILDING ENVELOPE la: <br />0.5 <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U = 0.28 <br />Floor R-38 <br />Xla__Co.mpliance <br />Slab on grade R-10 perimeter and under entire slab <br />Below grade slab R-10 perimeter and under entire slab <br />or <br />based on Section R402.1.4_'Reduce the Total UA by 5%. <br />lb <br />EFFICIENT BUILDING ENVELOPE 1b: <br />1.0 <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U = 0,2.5 <br />Wall R-21 plus R-4 <br />Floor R-38 <br />Basement - <br />wall R 21 int plus R-5 of <br />Slab on grade R-10 perimeter and under entire slab <br />Below grade slab R-10 perimeter and under entire slab <br />or <br />Com fiance based on Section R402.1.4: Reduce the Total UA by 150/.. <br />Ic <br />EFFICIENT BUILDING ENVELOPE Ic: <br />2.0 <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U = 0.22 <br />Ceiling and single -rafter or joist -vaulted R-49 advanced <br />Wood frame wall R-21 int plus R-12 ci <br />Floor R-38 <br />Basement wail R-21 int plus R-12 ci <br />Slab on grade R-10 perimeter and under entire slab <br />Below grade slab R-10 perimeter and under entire slab <br />or <br />Compliance based on Section R402.1.4: Reduce the Total UA by 30%. <br />Ida <br />EFFICIENT BUILDING ENVELOPE Id: <br />0.5 <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vei airdal fenestration U = 0.24 <br />OPTION <br />DESCRIPTION <br />2a <br />AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: <br />0:5 <br />Compliance based on R402.4.1.2: Reduce the tested air leakage to 3,0 air changes per <br />hour maximum <br />and <br />All whole house ventilation requirements as determined by Section M 1507.3 of the <br />International Residential Code shall be met with a high efficiency fan (maximum 0.35 <br />watts/char), not interlocked with the furnace fan. Ventilation systems using a furnace <br />including an ECM motor are allowed, provided that they are controlled to operate at low <br />speed in ventilation only mode. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the maximum tested building air leakage and shall <br />show the qualifying ventilation system. <br />2b <br />AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: <br />l.0 <br />Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air <br />changes per hour maximum <br />and <br />All whole house ventilation requirements as determined by Section M 1507.3 of the <br />International Residential Code shall be met with a heat recovery ventilation system <br />with minimum sensible heat recovery efficiency of 0.70. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the maximum tested building air leakage and shall <br />show the heat recovery ventilation system. <br />2c <br />AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 20: <br />1,5 <br />Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air <br />changes per hour maximum <br />and <br />All whole house ventilation requirements as determined by Section M 1507.3 of the <br />International Residential Code shall be met with a heat recovery ventilation system <br />with minimum sensible heat recovery efficiency of 0,85. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the maximum tested building air leakage and shall <br />ehnu, fk� h..f rare,ran, r ,.. __ <br />3a <br />HIGH EFFICIENCY HVAC EQUIPMENT 3a: <br />Gas, propane or oil -fired furnace with minimum AFUE of 94%, or <br />Gas, propane or oiled -fired boiler with minimum AFUE of 92% <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the heating equipment type and the minimum <br />equi ment efficiency: <br />1.0 <br />3b <br />HIGH EFFICIENCY hVAC EQUIPMENT 3b: <br />1.0 <br />Air -source heat pump with minimum BSPF of 9,0 <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the heating equipment type and the minimum <br />e ui mentefficiency. <br />3c <br />111t3B EFFICIENCY B\TAC EQUIPMENT 3c: <br />1.5 <br />Closed -loop ground source heat pump; with a minimum COP of 3.3 <br />or <br />Open loop water source heat pump with a maximum pumping hydraulic head of 150 <br />feet and minimum COP of 3.6 <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify, the heating equipment type and the minimum <br />equi meat efficiency. <br />r. ut{vee wtn,v c Ju. <br />Ductless Split System Heat Pumps, Zonal Control: In homes where the primary space <br />1,0 <br />heating system is zonal electric heating, a ductless heat pump system shall be installed <br />and provide heating to the largest zone of the housing unit. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the heating equipment type and the minimum <br />equipment efficiency. <br />4 <br />IISI EFF1tENC. ,-%is/AC D S 12iUTTON S� STE <br />All heating and cooling system components installed inside the conditioned space. This <br />includes all equipment and distribution system components such as forced air ducts. <br />hydronic piping, hydronic floor heating loop, convectors and radiators. All combustion <br />equipment shall be direct vent or sealed combustion. <br />For forced air duets: A maximum of 10 linear feet of return ducts and 5 linear feet of <br />supply ducts may be located outside the conditioned space. All metallic ducts located <br />outside the conditioned space must have both transverse and longitudinal joints sealed <br />with mastic. If flex ducts are used, they cannot contain splices. Flex duct connections <br />must be made with nylon straps and installed using a plastic strapping tensioning tool, <br />Ducts located outside the conditioned space must be insulated to a minimum of Rug, <br />Locating system components in conditioned crawl spaces is not permitted under this <br />option. <br />Electric resistance heat and ductless heat pumps are not permitted under this option. <br />Direct combustion heating equipment with AFUE less than 80% is not permitted under <br />this option. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the heating equipment type and shall show the location <br />of the heatinY and coolin e ui ment and all the ductwork. <br />5a <br />EFFICIENT WATER BEA IING 5a: <br />0.5 <br />All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 <br />GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less.` <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the maximum flow rates for all showerheads, kitchen <br />sink faucets, and other lavatoryfaucets. <br />5b <br />EFFICIENT WATER BEATING 5b: <br />1.0 <br />Water heating system shall include one of the following: <br />Gas, propane or oil water heater with a minimum EF of 0.74 <br />� di <br />N <br />Car <br />Water heater heated by ground source heat pump meeting the requirements of Option <br />3c. <br />M 6d er <br />or <br />oFol 4- <br />For R-2 occupancy, a central heat pump water heater with an EF greater than 2.0 that <br />would supply DBW to all the units through a central water loop insulated with R-g <br />minimum pipe insulation. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the water heater equipment type and the minimum <br />equipment efficiency. <br />Sc <br />EFFICIENT WATER HEATING 5c. <br />1.5 <br />Water heating system shall include one of the following: <br />Gas, propane or oil water heater with a minimum EF of 0.91 <br />or <br />Solar water heating supplementing a minimum standard water heater. Solar water <br />heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the <br />Solar Rating and Certification Corporation (SRCC) Annual Performance of OG-300 <br />Certified Solar Water Beating Systems. <br />or <br />Electric heat pump water heater with a minimum EF of 2,0 and meeting the standards of <br />NEEA's Northern Climate Specifications for Beat Pump Water heaters. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the water heater equipment type and the minimum <br />equipment efficiency and, for solar water heating systems, the calculation of the <br />OPTION <br />DESCRIPTION <br />CREDIT(S) <br />5d <br />EFFICIENT WATER BEATING 5d: <br />U <br />A drain water heat recovery unit(s) shall be installed, which captures waste water heat <br />from all the showers, and has a minimum efficiency of40% if installed for equal flow or <br />a minimum efficiency of 52% if installed for unequal flow. Such units shall be rated in <br />accordance with CSA B55.1 and be so labeled. <br />To qualify to claim this credit, the building permit drawings shall include a plumbing <br />diagram that specifies the drain water heat recovery units and the plumbing layout <br />needed to install it and labels or -other documentation shall be provided that <br />demonstrates that the unit complies with the standard. <br />6 <br />RENEWABLE ELECTRIC ENERGY: <br />0.5 <br />For each 1200 kWh of electrical generation per housing unit provided annually by <br />on -site wind or solar equipment a 0.5 credit shall be allowed, up to 3 credits. Generation <br />shall be calculated as follows: <br />For solar electric systems, the design shall be demonstrated to meet this requirement <br />using the National Renewable Energy Laboratory calculator PV WATTs. <br />Documentation noting solar access shall be included on the plans - <br />For wind generation projects designs shall document annual power generation based on <br />the following factors: <br />The wind turbine power curve; average annual wind speed at the site: frequency <br />distribution of the wind speed at the site and height of the tower. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall show the photovoltaic or wind turbine equipment type, provide <br />documentation of solar and wind access, and include a calculation of the minimum <br />annual energy power production. <br />a. Projects using this option may not use Option la, lbor lc. <br />b. Projects may only include credit from one space heating option, 3a, 3b, 3c or 3d, When a housing unit has two pieces of <br />equipment (i.e., two furnaces) both must meet the standard to receive the credit. <br />c. Plumbing Fixtures Flow Ratings. Low flow plumbing fixtures (water closets and urinals) and fittings (faucets and <br />showerheads) shall comply with the following requirements: <br />1. Residential bathroom lavatory sink faucets: Maximum flow rate - 3.8 L/min (1.0 gal/min) when tested in accordance <br />with ASME A112.1 8.1/CSA B125.1. <br />2. Residential kitchen faucets: Maximum flow rate - 6.6 L/min (1.75 gal/min) when tested in accordance with ASME <br />Al12.18.I/CSA B125.1, <br />3. Residential showerheads: Maximum flow rate - 6.6 L/min (1.75 gal/min) when tested in accordance with ASME <br />Al 12.19. I/CSA B125.1. <br />S him-u'I ARINE . <br />. <br />FENESTRA'noN U-FACTORa. <br />0.30 <br />SKYLIGHTu U-FACTOR <br />0.50 <br />GLAZED FENESTRATION SW X � <br />NR <br />CEILING-VALUEa <br />( 49 <br />WooD FRAME ALLO"n"R-VALUE <br />21 int <br />Mass Wall R-Value' <br />21/21 <br />Rom RNALUE <br />30 <br />BELOW -GRADE"' WALL R-VALUE <br />10/ 15/21 int + TB, <br />SLABd R-VALUE & DEPTH <br />10, 2 ft <br />For SI: I foot = 304,8 mart, ci = continuous insulation, int = intermediate framing, <br />a R-values are minimums. U-factors and SHOC are maximums. When insulation is installed in a cavity which <br />is less than the label or design thickness of the insulation, the compressed R-value of the insulation from <br />Appendix Table A101.4 shall not be less than the R-value specified in the table. <br />e The fenestration U-factor column excludes skylights. The SHGC column n applies to all glazed fenestration. <br />° ' 10/15/21 +TB" means R-10 continuous insulation on the exterior of the wall, or R-I5 continuous insulation <br />on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the <br />basement wall at the interior of the basement wall. "10/15/21 +TB" shall be permitted to be met with <br />R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior <br />or exterior of the wall. "713" means thermal break between floor .slab and basement wall. <br />d R 10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. <br />'There are no SHGC requirements in the Marine Zone. <br />f Reserved. <br />s Reserved. <br />" Reserved. <br />'The second R-value applies when more than half the insulation is on the interior of the mass wall, <br />Reserved, <br />k For single rafters .or joist -vaulted. ceilin s, the insulation m,ta be <br />ar� y red cad to R 3g. <br />'Reserved. <br />" Int. (ioter€tiediate framing) denotes standard framing 16 incites on center with headers insulated with a <br />i inimurnofR-10insulation. <br />'Log og and solid tirpber walls with a minimum average thie nm- of 3.5 inches 1s are exempt ftaorra this insulation <br />requirerruent. <br />i 1lllf 'lw <br />t� <br />fix <br />Date <br />R E r PERMIT Dp11 <br />Job <br />Shoot <br />Of Sheets <br />