Laserfiche WebLink
FOUND REBAR & CAP, <br />ILLEGIBLE <br />y 0.13'S X 0.15'E <br />o � <br />b <br />30' k <br />SSMH <br />RIM 182.75' <br />IE 36" (N,S)=166.93' <br />BOCK <br />FRI DAY'S SECOND ADDITION TO EVERETT <br />VOL. 3, P. 5 6 <br />24 <br />BLOCK 13 <br />NW 114, SE 114, SEC.301 T.29N., R.5E., W.M. <br />SNOHOMISH COUNTY, WASHINGTON <br />50' 22' <br />cv � <br />SCALE: 1 " = 20' <br />20 40 0 20 10 <br />/ '�QC7 by tiv� `. V <br />7 <br />CL CURVE DATAAl 4 P P _ �� \ \ \/ I a SEWER MAIN SYSTEM CONSTR UCTION PLAN NOTES: <br />L=181.70' cJa� J ❑ P ER u° 21 - �- 1 <br />R=153.10' �' 7 P VA LTS _ \ ' \ THE INSTALLATION OF ALL EXTENSIONS TO THE SANITARY SEWER SYSTEM SHALL BE DONE <br />Q=67°59'S6" \ I 4° PER PLANS WHICH HAVE BEEN APPROVED BY THE CITY ENGINEER. <br />a ° ` SANITARY SEWER PLANS ARE TO BE SEPARATE FROM OTHER UTILITY PLANS, BUT ALL <br />°o OTHER UTILITIES ARE TO BE SHOWN, WITH SANITARY SEWER PORTIONS HIGHLIGHTED. <br />UNLESS APPROVED OTHERWISE, PLANS SHOULD BE PREPARED ON 22 INCH BY 34 INCH <br />10 <br />PLAN/PROFILE TYPE SHEETS AND SHALL SHOW BOTH PLAN AND PROFILE VIEWS. OTHER <br />SSMH L=91. R I - y UTILITIES ARE TO BE SHOWN IN PROFILE VIEW AND IN PLAN VIEW. <br />r � <br />�: A R=183 ? 0 �� t c <br />RIM 186.12' 7 0 90 Voff ,/ V THE MINIMUM ALLOWABLE SCALE SHALL BE i INCH = 40 FEET, ON SMALL PROJECTS, IT <br />IE 36" (N,SW)=168.54' =28'34 33" 1 p SHALL BE EXPECTED THAT THE SCALE WILL BE ENLARGED TO ADEQUATELY UTILIZE THE <br />1 \ IE=171.50 ; TRASH FULL PLAN SHEET. (12' IN, NE) 2 0 \ \ � ' a: <br />p <br />CB T-1-- ------ g YD11 � � / ROOM � I � I \ PROVIDE NOTES ON PLANS THAT REFER TO SPECIFIC CITY STANDARDS FOR SUCH THINGS <br />RIM=185.14' RIM: 101.5°; : `C \ AS MANHOLES, DROP CONNECTIONS, SIDE SEWERS, ETC. <br />IE=181.01' (12" PVC E) IE: 179.5 p ELECTRICA <br />8 , / ROOM I� PLANS SHALL SHOW INVERT ELEVATIONS OF THE MAIN AT THE OUTLET AND ALL INLETS <br />CB T-2 W/OIL WATER SEP. P N OF EACH MANHOLE, SLOPE OF THE MAIN AND SURFACE ELEVATIONS OF THE MANHOLE <br />RIM=185.14' °a " rn " z 4Q LID. IN THE PROFILE VIEW, THE FINISH GROUND ELEVATION OVER THE PIPE SHALL BE <br />IE=180.40' (12 PVC NW) ,3 0 6 PVC 2% 6 PVC 0 0.6% Ig m <br />SHOWN AS WELL AS CROSSINGS OF OTHER EXISTING OR PROPOSED UTILITIES. STATIONING <br />IE=180.35' (12" PVC S) _1Z96 Yo12 _ �w j OF SIDE SEWERS FROM THE DOWNHILL MANHOLE IS REQUIRED. <br />_ RIM: 182t - 90 cn <br />Cn <br />lE=180.60' (12" PVC OUT SE) 4 Io STOP BAR <br />2 SSMH#1 6 ° FIRE RI �E: 179.12 �- \ Io I IN ALL CASES WHERE A NEW SEWER LINE IS TO BE LOCATED IN AN EASEMENT, THE <br />3 DOM 6' PVC 0 2%_ EX. ROCKERY o ` EASEMENT IS TO BE SHOWN WITH MEASUREMENT INFORMATION TO ACCURATELY FIELD <br />55 p I &STAIRS ci SURVEY AND STAKE LOCATION PRIOR TO CONSTRUCTING THE PIPE LINE. <br />/ 1 O \ MAR GAS TU o (TO BE RIt11lOVED) N <br />f 4 v, UPON COMPLETION OF CONSTRUCTION, THE ORIGINAL OF THE PLAN SMALL BE AS -BUILT <br />IGI - / BY THE DEVELOPER AND CERTIFIED AS AS -BUILT BY HIM AND TURNED INTO THE PUBLIC / G WORKS DEPARTMENT WITH PROPERLY EXECUTED EASEMENT DEEDS AS APPLICABLE FOR <br />S Q ° <br />THE PROJECT. <br />NIA/ 11 LF 12" SD ® 43.59% ® _ Cn <br />�O INSTALL BACKWATER VALVE - s T29' \TT <br />P " <br />ON STORM LINE CB#1 SEWER MAIN SYSTEM REQ UIRED NOTES: <br />SS Q L=36. 77' 11 LF 12" SD 0 0.00% \ Z 25LFN 8 PVGIpt % YD 5 1 o <br />_ YD16 RIM: 181.259 <br />=25.00' PROPOSED STORM AQUA SWIRL AS 2 � THE FOLLOWING STANDARD NOTES ARE REQUIRED ON ALL SANITARY SEWER .PLANS: <br />\ C4.4 RIM: 182E IE: 77. 1 ° <br />4= 4' 16' 14 /-- TANK UNDER PARKING PRETREATMENT E. 177 55 I P A. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETT STANDARDS <br />-' CB T-2 d _._.�� � `�' / ---_._ '`-- ------'-'_-,,` yD#8 RIM=181.5E <br />/� ( RIM: 188E IE=f77.3 n AND WSOOT/APWA STANDARD SPECIFICATIONS. <br />SA g1' RIM=187.10' d /y IE: 18 \ / "I TOY TOP" p ��✓/ <br />�66 55 35 IE=181.30' (12" PVC E) IN LEAD W HER I I NO PART OF THE SANITARY SEWER SYSTEM SMALL BE COVERED, CONCEALED OR PUT <br />P INTO USE UNTIL IT HAS BEEN TESTED, INSPECTED, AND APPROVED 8Y THE CITY <br />o 4 tJ D REB R INSPECTOR. <br />/ PROPOSED <br />a ] STOP R C. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM AVAILABLE <br />MSE WALL L=53.07 N8857 0fi E 1 8.03' GN PO E/ 0 4 RECORDS AND ARE SHOWN FOR CONVENIENCE THE CONTRACTOR SHALL BE RESPONSIBLE <br />TOP. 188.0 R=66.40' i GHT E ?CROSSWALK I FOR VERIFICATION OF LOCATIONS AND TO AVOID DAMAGE TO ANY ADDITIONAL UTILITIES <br />TOE: 184.0 d 45'47'37" 4 a CURB.: CUT: ° I NOT SHOWN. IF CONFLICTS WITH EXISTING UTIL177ES ARISE DURING CONSTRUCTION, THE <br />YD#JO <br />'r . S \ a . CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR AND ANY CHANGES REQUIRED <br />RIM: 184 o CB 1460 SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO COMMENCEMENT OF RELATED <br />1E: 183 \ ( � '�\ YD#9 .,,• ". � p CB 1456 <br />y'"RIM: 184� CONSTRUCTION ON THE PROJECT. <br />\ N6) WATER �"- LANE STR IE t82.S 37TH STR�ET / RIM7181.5a / o D. ALL SEWER MAIN EXTENSIONS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN EASEMENTS <br />S6- VAULT ,, rn N IE. 177.45 t? MUST BE STAKED BY SURVEY FOR LINE AND GRADE PRIOR TO STARTING CONSTRUCTION. <br />2, ry EASEMENT FOR \ W yam------- _ W'' - \ 1 /1 CB 1458 <br />STREET AND SW \ \ �-� <br />DEDICATED TO d _ <br />cnY of EVERETT _ - 7' S'E 179.6 7' �{ -- - - I Q i �2-00' WATER MAIN SYSTEM CONSTR UCTION PLAN NOTES: <br />i EL -- y�I d 0 m W / \ <br />N83'45'20T 127.35 -- - d 1--� \ <br />,.' � o CB 1457 A. WATER PLANS ARE TO 8E SEPARATE FROM OTHERS AND SHALL HAVE WATER MAINS <br />------ HIGHLIGHTED AND INDICATE LOCATIONS OF OTHER UTILITIES. <br />/MSE WALL <br />TOP=184.0 0�' <br />TOE=181.0 °= <br />CROSSWALK CB 1459 <br />/ SIGNAL POLE, EX. 6" WM <br />/ LIGHTPOLE <br />/ 7LF 8' DI d- � <br />WATER CONSTRUCTION NOTES: <br />O 1 WATER SYSTEM UPGRADE TO BE PERFORMED BY THE PUBLIC WORKS <br />DEPARTMENT AT CITY EXPENSE. COORDINATE TIMING OF THIS <br />WORK THROUGH THE PUBLIC WORK INSPECTOR RANDY ALLEN 425 OUG E ( ) <br />339-7403 <br />O CONTRACTOR TO POTHOLE EX, WATER TAPS. REUSE FOR 3/4' <br />IRRIGATION METER <br />O INSTALL: 1-4" DI TAPPING TEE (FL) <br />O 4" FIRE SERVICE METER PER COE STD 503, DCDA TO BE LOCATED <br />IN FIRE RISER ROOM <br />�5 4" DI FIRE LINE <br />FIRE DEPARTMENT CONNECTION TO BE MOUNTED TO BUILDING <br />7D 3" WATER METER PER COE STD 502 <br />O EX, WATER TAP TO BE KILLED BY WATER DEPARTMENT <br />4" DI DOMESTIC WATER LINE <br />i0 3/4" IRRIGATION METER W/DCVA <br />SEWER CONSTRUCTION NOTES: <br />0 CONNECT TO BUILDING SEWER PIPE IE=72.0 <br />INSTALL BACKWATER VALVE <br />OINSTALL SSMH PER COE STD 605 <br />3 1OLF-8" PVC ® 1.0% <br />4 14LF- 12" PVC 0 1.07o <br />O6" PVC FOOTING DRAIN (SEE ARCHITECTS PLAN FOR DETAILS) <br />OCOORDINATE CONNECTION TO MANHOLE WITH BRIAN DOLAN (425) 257-8828 <br />6" PVC <br />o V <br />WALL <br />V D <br />IN <br />RAMP DETAIL <br />SCALE: 1 "=10' HORIZ, 1`_-1' VERT <br />I <br />I <br />SWIRL <br />D <br />/ <br />r <br />/ <br />INLET BASIN <br />/ <br />RIM=178.76' <br />/ <br />(E=177.72' (6" DI NE) <br />/WATER MAIN SYSTEM GENERAL NOTES: <br />/ <br />/ ALL CONSTRUCTION OF WATER MAINS AND RELATED APPURTENANCES SHALL <br />AFTER THE INSTALLATION OF ANY WATER SERVICE BY THE PUBLIC WORK <br />/ CONFORM TO THESE STANDARDS, APPLICABLE AMERICAN WATER WORKS ASSOCIATION <br />DEPARTMENT, THE PROPERTY OWNER SHALL BE HELD RESPONSIBLE FOR, <br />/ (AWWA) SPECIFICATIONS AND APPLICABLE SECTIONS OF DIVISION 7 OF THE <br />MAY BE CHARGED FOR, ANY AND ALL DAMAGES TO THE SERVICE LINE, <br />/ WSDOT/APWA STANDARD SPECIFICATIONS. THE GENERAL REQUIREMENTS OF AWWA <br />SETTER METER AND METER BOX S AU T OR ANY NC <br />E /V L A OTHER APPURTENA <br />/ AND THE WSDOT/APWA STANDARD SPECIFICATIONS SHALL APPLY UNLESS THEY ARE <br />UNTIL COMPLETION OF CONSTRUCTION AND/OR THE STRUCTURE IS APPR <br />/ INCONSISTENT WITH ANY OF THE PROVISIONS OF THIS PARTICULAR SECTION. <br />FOR OCCUPANCY <br />/ SHOULD INCONSISTENCIES OCCUR, THESE STANDARDS SHALL HAVE PRECEDENCE. <br />/ ALL REFERENCE TO STANDARD SPECIFICATIONS SUCH AS AWWA OR WSOOT/APWA <br />ALL WATER MAINS ON PRIVATE PROPERTY THAT ARE LOOPED BACK TO T <br />/ SHALL REQUIRE THE USE OF THE LATEST EDITION. <br />PUBLIC RIGHT-OF-WAY OR ARE OPEN TO THE GENERAL PUBLIC SYSTEM <br />/ <br />SHALL BE INSTALLED IN EASEMENTS, GRANTED TO THE CITY, AND SHALL <br />/ ANY PUBLIC WATER SYSTEM OR ANY PLUMBING IN A RESIDENTIAL OR <br />MAINTAINED BY THE CITY. (SEE SECTION 5-8.6 FOR MAIN LOOPING <br />/ NONRESIDENTIAL FACILITY PROVIDING WATER FOR HUMAN CONSUMPTION WHICH IS <br />REQUIREMENTS.) <br />/ CONNECTED TO A PUBLIC WATER SYSTEM SHALL BE LEAD FREE. WITH RESPECT TO <br />SOLDERS AND FLU "LEAD FREE"SHALL MEAN NO MORE THAN .2% LEAD. WITH <br />/ X, E H 0 TH <br />H MINIMUM <br />THE WATER MAIN EASEMENT WIDTH SHALL BE 15 FEET, 5 FEET <br />/ RESPECT TO PIPES AND PIPE FITTINGS, "LEAD FREE" SHALL MEAN NO MORE <br />ONE SIDE AND 10 FEET ON THE OTHER SIDE AND SHALL BE EXCLUSIVE <br />/ THAN 8% LEAD. <br />THE WATER MAIN AND APPURTENANCES. THE LEGAL DESCRIPTION SHALL <br />/ <br />PREPARED BY A SURVEYOR LICENSED TO PRACTICE IN THE STATE OF <br />/ WATER MAIN EXTENSIONS WILL BE REQUIRED WHEN THE PROPERTY DOES NOT <br />WASHINGTON. THE EASEMENT SHALL BE REVIEWED AND APPROVED BY TH <br />FRONT ON A WATER MAIN OR WHEN THE EXISTING WATER MAIN IS NOT ADEQUATE <br />PUBLIC WORKS DIRECTOR OR HIS DESIGNEE PRIOR TO ACCEPTANCE. <br />TO MEET THE MINIMUM FlRE FLOW REQUIREMENT. THE NEW WATER MAIN EXTENSION <br />SHALL EXTENDED ACROSS THE PROPOSALS FULL FRONTAGE AND SHALL BE <br />DUE TO THE COMPLEXITIES OF MANY WATER MAINS AND THEIR WTERFAC <br />EXTENDED THROUGH AND TO THE LIMITS OF THE PROPERTY BEING DEVELOPED FOR <br />WITH OTHER UNDERGROUND STRUCTURES, ALL WATER MAIN CONSTRUCTID <br />SYSTEM CIRCULATION OR FUTURE DEVELOPMENT AS DETERMINED BY THE PUBLIC <br />SHALL BE STAKED TO ENSURE PLACEMENT WITHIN DESIGNATED EASEMEN <br />WORKS DEPARTMENT. THE MINIMUM SIZE WATER MAIN SHALL BE DETERMINED BY <br />ANY DEVIATION FROM THIS REQUIREMENT MUST BE APPROVED BY THE P <br />THE PUBLIC WORKS DEPARTMENT AND SHALL BE AT LEAST 8" INCHES IN DIAMETER <br />WORKS DIRECTOR OR HIS DESIGNEE. <br />UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DIRECTOR OR HIS DESIGNEE. <br />UPON COMPLETION OF THE INSTALLATION OF THE WATER SYSTEM, THE <br />WATER MAIN EXTENSIONS OR REPLACEMENTS AND/OR NEW FIRE HYDRANT <br />ORIGINAL SIGNED DRAWING OF THE WATER CONSTRUCTION PLAN MUST B <br />INSTALLATIONS MAY ALSO BE REQUIRED PER THE REQUIREMENTS OF THE CITY FIRE <br />EDITED TO REFLECT ACTUAL CONSTRUCTED CONDITIONS (RECORD DRAWIN <br />MARSHAL. FIRE HYDRANT INSTALLATIONS ARE NOT ALLOWED ON WATER MAINS THAT <br />BY THE DEVELOPER/CONTRACTOR, CERTIFIED AS SUCH BY HIM AND TUR <br />DO NOT MEET THE MINIMUM FIRE FLOW REQUIREMENTS OF THE AREA. IN A SINGLE <br />INTO THE CITY. A RECORD DRAWING PRINT SHALL BE SUBMITTED FOR <br />FAMILY / DUPLEX NEIGHBORHOOD, THE FIRE FLOW IN THE MAIN MUST BE A <br />CHECKING BY THE CITY INSPECTOR AND PUBLIC WORKS DEPARTMENT PR <br />MINIMUM OF 1000 GPM BEFORE THE INSTALLATION OF A FIRE HYDRANT IS <br />TO SUBMITTING THE REVISED ORIGINALS. THE WATER RECORD DRAWING S <br />ALLOWED. <br />BE SUBMITTED WITHIN 14 DAYS OF THE PUBLIC WATER MAIN BECOMING <br />A FIRE HYDRANT IS REQUIRED WITHIN 350 FEET OF EVERY STRUCTURE FOR SINGLE <br />THE INSTALLATION OF ALL WATER MAINS AND APPURTENANCES SHALL BE <br />FAMILY HOMES AND DUPLEXES AS WELL AS NEW SUBDIVISIONS AND SHORT <br />ACCORDANCE WITH THE CONSTRUCTION PLANS AS APPROVED BY THE PU <br />SUBDIVISION FOR SINGLE FAMILY HOMES AND DUPLEXES. <br />WORKS DIRECTOR OR HIS DESIGNEE FOR THE PROJECT. ANY DEVIATIONS <br />CHANGES ARE TO BE APPROVED BY PUBLIC WORKS DIRECTOR OR HIS <br />FOR ALL OTHER BUILDINGS FROM TRIPLEXES TO COMMERCIAL USES, A FIRE <br />DESIGNEE BEFORE THE CHANGES ARE INCORPORATED INTO THE WORK. <br />HYDRANT IS REQUIRED WITHIN 200 FEET, BUT NOT CLOSER THAN 50 FEET TO ANY <br />STRUCTURE (MEASURED DISTANCE TO BE ALONG ROUTE TO BE TRAVELED BY FIRE <br />ALL MATERIALS SHALL BE NEW AND UNDAMAGED. UNLESS OTHERWISE <br />EQUIPMENT). <br />APPROVED BY THE PUBLIC WORKS DIRECTOR OR HIS DESIGNEE, THE SA <br />MANUFACTURER OF EACH ITEM SHALL BE USED THROUGHOUT THE WORK. <br />WATER METERS ARE REQUIRED FOR ALL NEW SERVICES INCLUDING DOMESTIC, <br />CONTRACTORS SHALL FURNISH A WATER TIGHT PLUG OF THE APPROPRIA <br />IRRIGATION AND FIRE SERVICES. <br />SIZE WHICH SHALL BE INSTALLED IN THE END OF THE WATER MAIN AN <br />WORK IS DELAYED OR STOPPED. <br />B. PLANS MUST SHOW EASEMENTS WHERE MAINS ARE ON PRIVATE PROPERTY AND ALL <br />HYDRANTS, METERS, AND OTHER APPURTENANCES MUST BE WITHIN THE EASEMENTS. <br />EASEMENTS MUST MEET THE REQUIREMENTS OF SECTION 5-1. <br />C. EASEMENTS MUST BE EXECUTED AT COMPLETION OF CONSTRUCTION. EASEMENTS FOR <br />sC WATER MAINS MUST BE 15 FEET WIDE WITH THE CENTER OF THE WATER MAIN 5 FEET FROM <br />ONE OF THE SIDES LEAVING 10 FEET ON THE OTHER. ACCESS TO EASEMENTS FOR <br />MAINTENANCE MUST REMAIN OPEN. STRUCTURES, FENCES, AND SHRUBS ARE NOT TO BE <br />PLANTED ON EASEMENTS. <br />D. SHOW ELEVATIONS OF SEWER MAINS, WATER MAINS AND STORM DRAINS WHERE THEY <br />o CROSS EACH OTHER. <br />z <br />g E. POTABLE WATER MAINS SHALL MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL CLEARANCE <br />AND 18 INCHES VERTICAL SEPARATION ABOVE NON -POTABLE UTILITIES (INCLUDING SEWER, <br />STORM DRAINAGE AND IRRIGATION) WHENEVER POSSIBLE. IF SITE CONDI7ONS DO NOT ALLOW <br />z SUCH MINIMUM SEPARATIONS, PIPELINES MAY BE LOCATED CLOSER TO EACH OTHER <br />PROVIDED ADDITIONAL PRECAUTIONS ARE IDENTIFIED AND INSTITUTED TO ASSURE PROTECTION <br />OF THE POTABLE LINE. NO OTHER UTILITIES, POTABLE OR NON -POTABLE, SHALL BE WITHIN 5 <br />FEET HORIZONTAL AND 12 INCHES VERTICAL FROM THE WATER MAIN. <br />S F. ALL INSTALLED HYDRANTS MUST BE COVERED BY A BURLAP BAG OR OTHER SUITABLE <br />AND COVERING UNTIL ACCEPTED BY THE PUBLIC WORKS DIRECTOR OR HIS DESIGNEE AND PLACED <br />METER IN SERVICE. <br />O G. A WASHINGTON STATE APPROVED BACKFLOW PREVENTION DEVICE IS REQUIRED FOR ALL <br />OVED IRRIGATION SYSTEMS. <br />HE H. ALL ENVIRONMENTAL SENS177VE AREAS SHALL BE SHOWN ON THE WATER SYSTEM <br />CONSTRUCTION PLANS. <br />BE I. PLANS MUST SHOW REQUIRED THRUST RESTRAINT PER SECTION 5-13 OF THESE <br />STANDARDS. <br />J. ALL WATER CONSTRUCTION PLANS SHALL BE PREPARED, STAMPED AND SIGNED BY AN <br />ON ENGINEER REGISTERED IN THE STATE OF WASHINGTON. <br />FOR <br />BE WATER MAIN S YS TEM REQ UIRED NOTES: <br />E A. NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY <br />MEANS OF AN APPROVED BACKFLOW PREVENTION DEVICE PRIOR TO <br />E SATISFACTORY FLUSHING, TESTING, DISINFECTION, AND RECEIPT OF <br />N SATISFACTORY BACTERIOLOGICAL TEST RESULTS. <br />S. B. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL BE MADE BY THE <br />EIBLIC PUBLIC WORKS DEPARTMENT AT THE DEVELOPER'S EXPENSE. THE PUBLIC <br />WORKS DEPARTMENT SHALL BE GIVEN AT LEAST 5 BUSINESS DAYS NOTICE <br />FOR EACH CONNECTION. THE PUBLIC WORKS DEPARTMENT SHALL THEREAFTER <br />E DETERMINE THE DATE AND TIME AT WHICH THE CONNECTION SHALL BE MADE. <br />GS) C. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT <br />NED STANDARDS. <br />TOR D. A PRE -CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR TO <br />LIVE. THE START OF CONSTRUCTION. THE CITY OF EVERETT PUBLIC WORKS <br />CONSTRUCTION DIVISION MUST BE NOTIFIED AT LEAST 24 HOURS PRIOR TO <br />IN COMMENCEMENT OF CONSTRUCTION. <br />BLIC E. THE DEVELOPER OR THE DEVELOPER'S AUTHORIZED AGENT SHALL NOTIFY <br />OR THE PUBLIC WORKS DEPARTMENT OF A PERSON WHO CAN BE CONTACTED <br />REGARDING PROBLEMS DURING CONSTRUCTION ON A 24 HOUR BASIS. <br />F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VERTICAL <br />ME SEPARATION BETWEEN POTABLE AND NON -POTABLE CONVEYANCE SYSTEMS. <br />G. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBLIC WORKS <br />IYT ME DEPARTMENT PERSONNEL ONLY. ALL VALVES, NEW AND EXISTING, SHALL BE <br />ACCESSIBLE AT ALL TIMES. <br />C <br />PROJECT ID/ <br />0 1 H CONTRACT NO: <br />800 Series MAXI <br />Non -Sloped <br />Heavy Duty System LOCATION: T <br />ENGINEERING SPECIFICATION: <br />POLYCAST® 800 Series MAXI Heavy Duty System is a <br />non -sloping trench drain, with 12" [305mm] wide x 48" [1219mm] <br />long (standard) polyester polymer concrete channels with <br />tongue and groove connections. <br />6' [152m ] or a 8" [203mm] drain drill 111 out required. <br />asl(102mm}, <br />•�����p� ���p���� <br />MALE ENO <br />45" <br />11219-3 <br />TONGUE & GROOVE <br />CHANNELJOINT9 <br />fu..j <br />,2" <br />[305mmj <br />10 V5" <br />[257mm] <br />I' [203mm]I <br />1 314" I T <br />44mm] <br />A ore 1A[25mm1 <br />U (.,B). <br />R4" <br />Channel Number <br />Weight <br />Inlet <br />Outlet <br />(LOS.) <br />Dim 'A' <br />Dim V <br />825E w/ 4" Bottom Drill Out (Non -Sloped) 1 <br />165 <br />13-3/4 <br />13.3/4 <br />Grate Options (Select One) <br />Grate Type yP <br />Part No. Load Class <br />MAXI! Fiberglass <br />DG0844 Class D <br />MAXIt Cast Iron Slotted <br />DG0841 Class E <br />MAXI! Cast Iron Solid <br />DG0842 Class E <br />Options (Select All That Apply) <br />Part No. <br />Additional Specifications: <br />(] <br />Vinyl Ester Concrete Channels <br />DVO825B <br />[� <br />Closed End Cap (Inlet/Outlet) <br />DPO825C <br />[� <br />Drain End Cap (4" Outlet) <br />DPO825DM4 <br />Drain End Cap (6" Outlet) <br />DPO825DM6 <br />❑ <br />Drain End Cap (8" Outlet) <br />DPO825DMB <br />Meets the following Standards & Specifications: <br />• Federal Aviation Administration (FAA) Advisory Circular Airport <br />Pavement Design and Evaluation (AC 15015320.6D Appendix 3 <br />Design of Structures for Heavy Aircraft) <br />• ASTM Standard D543, Test Method for Resistance of Plastics to <br />Chemical Reagents <br />• ASTM Standard 0570, Test Method for Water Absorption of Plastic <br />• ASTM Standard D576, Practice for Determination of Weight and <br />Shape Change of Plastics Under Accelerated Service Conditions <br />• ASTM Standard G53, Recommended Practice for Operating Light and <br />Water Exposure Apparatus for Exposure of Non -Metallic Materials <br />• ASTM Standard C78, Test Method for Flexural Strength of Concrete <br />• ASTM Standard C579, Test Method for Compressive Strength of <br />Chemical Resistant Mortars and Monolithic Surfacing's <br />+ AASHTO Highway Drainage Guidelines <br />• AASHTO Standard Specification for Highway Bridges <br />HUBBELL <br />www.polycastdrain.com <br />Toll Free Number: <br />1.800.346-3062 <br />1 TRENCH DRAIN DETAIL <br />C4.0 N.T.S. <br />Know what's below. <br />SEWER MAIN SYSTEM GENRAL NOTES: Call before you dig. <br />CONSTRUCTION OF ALL SANITARY SEWER MAINS, SIDE UTILITY CONFLICT NOTE ' <br />SEWERS (LATERALS) -WHETHER SIDE SEWERS ARE BY GRAVITY, BY FORCE <br />PC-30 <br />7114/09 <br />MAIN, OR PRESSURE SEWER -AND RELATED FACILITIES, INCLUDING BUT CAUTION.' <br />NOT LIMITED TO SEWER LIFT STATIONS, TELEMETRY FACILITIES AND <br />APPURTENANCES WILL BE UNDER THE SUPERVISION OF THE CITY AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE <br />SHALL BE IN COMPLIANCE WITH ALL ORDINANCES AND CURRENT LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER <br />STANDARDS OF THE CITY OF EVERETT, WASHINGTON STATE DEPARTMENT SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND <br />OF ECOLOGY CRITERIA FOR SEWAGE WORKS DESIGN (ORANGE BOOK), OR SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO <br />THE UNIFIED PLUMBING CODE AS APPLICABLE. CONSTRUCTION, THIS SHALL INCLUDE CALLING UTILITY LOCATE <br />1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT <br />SEWER MAIN EXTENSIONS WILL BE REQUIRED WHEN THE PROPERTY DOES LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER <br />NOT FRONT ON A SEWER MAIN OR WHEN THE EXISTING SEWER MAIN IS OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON <br />NOT ADEQUATE FOR THE INCREASED USE PROPOSED. THE MINIMUM THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION <br />EXTENSION SHALL BE TO A POINT AT LEAST 5 FEET INSIDE THE AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE <br />PROLONGATION OF THE PROPERTY LINE. CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO <br />EACH SIDE SEWER SHALL SERVE ONLY ONE BUILDING AND ONE PARCEL RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. <br />(ONE CONNECTION FROM LOT TO MAIN) PER SECTION 6-8.3 AND EMC <br />14.08.170. <br />ALL NEW SEWER CONNECTIONS SHALL COMPLY WITH BACKWATER VALVE I <br />REQUIREMENTS IN EMC 14.08.180 B.1. <br />ALL PIPE INSTALLED SHALL BE STRUCTURALLY SOUND FOR THE DESIGN <br />DEPTH. <br />REQUIREMENTS FOR NEW PROPOSED LIFT (PUMP) STATIONS TO BE <br />DEDICATED TO THE CITY ARE PROVIDED IN SECTION 6-5.1 AND PER THE <br />CITY'S CURRENT LIFT STATION STANDARDS AS ESTABLISHED BY THE CITY'S <br />MAINTENANCE IVISION SEW UTILITY. STATIONS ARE DEFINED D / ER LER LIFTS N EIO AS <br />SEWAGE PUMPING SYSTEMS THAT SERVE MULTIPLE RESIDENTIAL LOTS OR <br />CITY OF EVERETT <br />A NON-RESIDENTIAL DEVELOPMENT GENERATING SIGNIFICANT SEWAGE <br />REVIEWED FOR PERMIT <br />VOLUME. LIFT STATIONS MUST BE DEMONSTRATED TO BE NEEDED, COST <br />EFFECTIVE FOR THE CITY TO OWN AND MAINTAIN BASED ON SEWER RATES <br />AND LIFECYCLE 0&M COSTS, MEET THE MAINTENANCE DIVISION <br />STANDARDS, AND BE PERMITTED AND APPROVED SOLELY AT THE INTEREST <br />OF THE DEPARTMENT GRINDER PUMP INSTALLATION FOR INDIVIDUAL <br />PARCELS MAY BE ALLOWED UNDER SEPARATE REVIEW PER SECTION 6-5.2. <br />ALL REQUESTS FOR INSPECTIONS AND FOR WITNESSING ACCEPTANCE <br />TESTS SHALL BE SCHEDULED WITH THE PUBLIC WORKS INSPECTOR AT <br />LEAST 24 HOURS IN ADVANCE FAILURE TO GIVE ADEQUATE ADVANCE <br />N0710E MAY RESULT IN DELAYS TO THE CONTRACTOR FOR REQUIRED <br />INSPECTIONS. <br />