Laserfiche WebLink
VERETT <br />0 <br />Permit Inspections <br />City of Everett <br />12/14/2022 <br />12/14/2022 <br />ELEC 10-FINAL <br />STEVE BANKS <br />CORRECTION <br />eTRAKiT Inspection Request <br />REQUIRED <br />Notes: <br />12/13/2022 10:59 AM Garin Schenk <br />Contact Name: Garin Schenk <br />Site Address: 615 35TH ST <br />Phone:2069310990 <br />e-Mail: garin@archstudioeverett.com <br />GFCI protection required for our kitchen, countertop, bathroom receptacles and receptacles, within 6 feet of the sink or in an unfinished basement. <br />Install arc shield and cover plates for disposal and dishwasher circuits. The grounded conduct cannot be regrounded in the sub panel. The drier <br />receptacle must be a 4 wire receptacle. Mark the equipment grounding contractor to the panel with green tape. Seal the feeder conduit. <br />GFCI protection required for our kitchen, countertop, bathroom receptacles and receptacles, within 6 feet of the sink or in an unfinished basement. <br />Install arc shield and cover plates for disposal and dishwasher circuits. The grounded conduct cannot be regrounded in the sub panel. The drier <br />receptacle must be a 4 wire receptacle. Mark the equipment grounding contractor to the panel with green tape. Seal the feeder conduit. <br />12/14/2022 <br />12/14/2022 <br />ELEC 05 SERVICE <br />STEVE BANKS <br />APPROVAL <br />Notes: <br />200 amp outdoor meter all in one with a 200 amp indoor feeder panel. <br />1/4/2023 <br />1/4/2023 <br />ELEC 10-FINAL <br />STEVE BANKS <br />CORRECTION <br />eTRAKiT Inspection Request <br />REQUIRED <br />Notes: <br />1/3/2023 2:16 PM Garin Schenk <br />Contact Name: Garin Schenk <br />Site Address: 615 35TH ST <br />Phone:2069310990 <br />e-Mail: garin@archstudioeverett.com <br />GFCI protect the kitchen counter receptacles, the undercounter receptacles. Reroute the grounding electrode conductor from the water bond all the <br />way to the service grounded bus. <br />1/11/2023 <br />1/12/2023 <br />ELEC 10-FINAL <br />STEVE BANKS <br />CORRECTION <br />eTRAKiT Inspection Request <br />REQUIRED <br />Notes: <br />1/10/2023 12:46 PM Garin Schenk <br />Contact Name: Garin Schenk <br />Site Address: 615 35TH ST <br />Phone:2069310990 <br />e-Mail: garin@archstudioeverett.com <br />Grounding, electrode conductor, must be continuous from the water to the service, or must be irreversibly crimped. You cannot use mechanically <br />reversible connections along the way. <br />I <br />Printed: Monday, 13 February, 2023 3 of 4 rk <br />SUPERION <br />