<br />BUILDING CODE & REFERENCE STANDARDS: THE "INTERNATIONAL BUILDING CODE", 2015 EDITION, GOVERNS THE
<br />DESIGN AND CONSTRUCTION OF THIS PROJECT. REFERENCE TO A SPECIFIC SECTION IN THE CODE DOES NOT
<br />RELIEVE THE CONTRACTOR FROM COMPLIANCE )NTH THE ENTIRE MATERIALS REFERENCE STANDARDS NOTED
<br />BELOW. THE LATEST EDITION OF THE MATERIALS REFERENCE STANDARDS SHALL BE USED.
<br />ARCHITECTURAL DRAWINGS: REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION INCLUDING, BUT NOT
<br />LIMITED T0: DIMENSIONS, ELEVATIONS, SLOPES, DOOR AND WINDOW OPENINGS, NON -BEARING WALLS, STAIRS,
<br />CURBS, DRAINS, DEPRESSIONS, RAILINGS, WATERPROOFING, FINISHES AND OTHER NONSTRUCTURAL ITEMS.
<br />STRUCTURAL RESPONSIBIUTIES: THE PE IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE PRIMARY
<br />STRUCTURE IN ITS COMPLETED STATE.
<br />CONTRACTOR RESPONSIBILITIES: THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF
<br />CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA AND WSHA. THE CONTRACTOR IS
<br />RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE STRUCTURE DURING CONSTRUCTION AND SHALL PROVIDE
<br />TEMPORARY SHORING, BRACING AND OTHER ELEMENTS REQUIRED TO MAINTAIN STABILITY UNTIL THE STRUCTURE
<br />IS COMPLETED. IT IS THE CONTRACTOR'S RESPONSIBUTY TO BE FAMILIAR WITH THE WORK REQUIRED IN THE
<br />CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR EXECUTING IT PROPERLY,
<br />DISCREPANCIES: IN CASE OF DISCREPANCIES BETWEEN THESE GENERAL NOTES, THE CONTRACT DRAWINGS AND
<br />SPECIFICATIONS, AND/OR REFERENCE STANDARDS, THE ENGINEER SHALL DETERMINE WHICH SHALL GOVERN,
<br />DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK.
<br />SITE VERIFICATION: THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO
<br />FABRICATION AND/OR CONSTRUCTION. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL
<br />BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ALL UNDERGROUND
<br />UTILITIES SHALL BE DETERMINED BY ME CONTRACTOR PRIOR TO EXCAVATION OR DRILLING.
<br />WIND DESIGN: BASIC WIND SPEED (3-SECOND GUST), V = 85 MPH(ASD} WIND IMPORTANCE FACTOR, IW =
<br />1.0; OCCUPANCY CATEGORY = II; EXPOSURE CATEGORY = D;
<br />SEISMIC DESIGN: SEISMIC IMPORTANCE FACTOR IE 1.0; OCCUPANCY CATEGORY = II; SS = 1.279G; S1 =
<br />0.487G; SITE CLASS = D; SDS = 0.853G; SDI = 0.491G; SEISMIC DESIGN CATEGORY = D;
<br />BASIC SEISMIC FORCE RESISTING SYSTEM = A-13 (BEARING WALL SYSTEMS) LIGHT -FRAMED
<br />WALLS WITH WOOD STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE; CS = 0.092; R =
<br />6.5; ANALYSIS PROCEDURE = EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7, SEC 12.8.
<br />SNOW LOAD: GROUND SNOW LOAD, PG = 25 PSF; FLAT ROOF SNOW LOAD, PF = 25 PER (DRIFT LOADS
<br />CONSIDERED PER ASCE 7 WHERE APPLICABLE); SNOW EXPOSURE FACTOR, CE = 1.0; SNOW
<br />IMPORTANCE FACTOR, IS = 1.0, THERMAL FACTOR, CT = 1.0.
<br />LIVE LOADS: ROOF (LIVE) 20 PSF
<br />ROOF (SNOW) 25 ESE
<br />RESIDENTIAL FLOOR 40 PER
<br />RESIDENTIAL DECK 60 PER
<br />DEFERRED SUBMITTALS: ITEMS DESIGNED BY OTHERS SHALL INCLUDE CALCULATIONS, SHOP DRAWINGS AND
<br />PRODUCT DATA. DESIGN SHALL BE PREPARED BY THE SSE AND SUBMITTED TO THE ARCHITECT AND PE FOR
<br />REVIEW PRIOR TO SUBMISSION TO THE JURISDICTION FOR APPROVAL. THE SSE SHALL SUBMIT TO THE ENGINEER
<br />FOR RENEW CALCULATIONS AND SHOP DRAWINGS THAT ARE STAMPED AND SIGNED BY THE SSE. RENEW OF ME
<br />SEE'S SHOP DRAWINGS IS FOR GENERAL COMPLIANCE WITH DESIGN CRITERIA AND COMPATIBILITY WITH THE DESIGN
<br />OF THE PRIMARY STRUCTURE AND DOES NOT REUEVE THE SSE OF RESPONSIBILITY FOR THAT DESIGN. ALL
<br />NECESSARY BRACING, TIES, ANCHORAGE, AND PROPRIETARY PRODUCTS SHALL BE FURNISHED AND INSTALLED PER
<br />MANUFACTURER'S INSTRUCTIONS OR THE SSE'S DESIGN DRAWINGS AND CALCULATIONS.
<br />INSPECTIONS: ALL CONSTRUCTION IS SUBJECT TO INSPECTION BY THE BUILDING OFFICIAL IN ACCORDANCE WITH
<br />IBC SEC 109. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED INSPECTIONS WITH THE BUILDING OFFICIAL.
<br />SUBMIT COPIES OF ALL INSPECTION REPORTS TO THE ENGINEER FOR REVIEW.
<br />PREFABRICATED CONSTRUCTION: ALL PREFABRICATED CONSTRUCTION SHALL CONFORM TO IBC SEC 1703.6.
<br />GEOTECHNICAL INSPECTION: THE GEOTECHNICAL ENGINEER OR BUILDING OFFICIAL SHALL INSPECT ALL PREPARED
<br />SOIL BEARING SURFACES PRIOR TO PLACEMENT OF CONCRETE AND REINFORCING STEEL AND PROVIDE A LETTER
<br />TO ME OWNER STATING THAT SOILS ARE ADEQUATE TO SUPPORT THE "ALLOWABLE FOUNDATION PRESSURE"
<br />SHOWN BELOW. SOIL VALUES SHALL BE FIELD VERIFIED BY THE BUILDING OFFICIAL OR THE GEOTECHNICAL
<br />ENGINEER PRIOR TO PLACING CONCRETE.
<br />DESIGN SOIL VALUES:
<br />ALLOWABLE BEARING PRESSURE (ASSUMED) 1500 PER
<br />PASSIVE LATERAL PRESSURE 150 PSF/FT
<br />ACTIVE LATERAL PRESSURE (UNRESTRAINED) 35 PSF/FT
<br />ACTIVE LATERAL PRESSURE (RESTRAINED) 50 PSF/FT
<br />COEFFICIENT OF SLIDING FRICTION 0.25
<br />SLABS -ON -GRADE & FOUNDATIONS: ALL FOUNDATIONS SHALL BEAR ON STRUCTURAL COMPACTED FILL OR
<br />COMPETENT NATIVE SOIL PER THE GEOTECHNICAL REPORT. ALL SLABS -ON -GRADE SHALL BE FOUNDED ON
<br />APPROPRIATE SUB -GRADE PREPARATION AS NOTED IN THE GEOTECHNICAL REPORT. EXTERIOR PERIMETER
<br />FOOTINGS SHALL BEAR NOT LESS THAN 18 INCHES BELOW FINISH GRADE, OR BY ME GEOTECHNICAL ENGINEER
<br />AND THE BUILDING OFFICIAL. INTERIOR FOOTINGS SHALL BEAR NOT LESS THAN 12 INCHES BELOW FINISH FLOOR.
<br />COMPACTION: UNLESS OTHERWISE SPECIFIED BY A GEOTECHNICAL ENGINEER, FOOTINGS SHALL BE PLACED ON
<br />COMPACTED MATERIAL AND SHALL BE WELL -GRADED GRANULAR MATERIAL WITH NO MORE THAN 5% PASSING A
<br />#2 SIEVE. HILLS PLACED SHALL BE IN MAXIMUM 8" LIFTS AND ALL BEARING SOILS SHALL BE COMPACTED TO 957
<br />MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT USING THE MODIFIED PROCTOR TEST.
<br />CAST -IN -PLACE CONCRETE & REINFORCEMENT
<br />REFERENCE STANDARDS: CONFORM TO:
<br />(1) ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY".
<br />(2) IBC CHAPTER 19.
<br />(3) ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE", SEC 3 "REINFORCEMENT AND
<br />REINFORCEMENT SUPPORTS.°
<br />FIELD REFERENCE: THE CONTRACTOR SHALL KEEP A COPY OF ACI FIELD REFERENCE MANUAL, SP-15, "STANDARD
<br />SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301) WM SELECTED ACI AND ASTM REFERENCES."
<br />CONCRETE MIXTURES: CONFORM TO ACI 318 CHAPTER 5 "CONCRETE QUALITY, MIXING, AND PLACING."
<br />MATERIALS: CONFORM TO ACI 318 CHAPTER 3 "MATERIALS" FOR REQUIREMENTS FOR CEMENDTOUS MATERIALS,
<br />AGGREGATES, MIXING WATER AND ADMIXTURES.
<br />REINFORCING BARS ASTM A615, GRADE 60, DEFORMED BARS.
<br />DEFORMED WELDED WIRE FABRIC ASTM A497
<br />BAR SUPPORTS CRSI MSP-2, CHAPTER 3 "BAR SUPPORTS."
<br />TIE WIRE 16.5 GAGE OR HEAVIER, BLACK ANNEALED.
<br />MIX DESIGNS: PROVIDE A 5-SACK MINIMUM, 28-DAY COMPRESSIVE STRENGTH F'C = 2.500 PSI CONCRETE MIX
<br />WITH MAXIMUM 3/4" AGGREGATE AND 0.50 W/C RATIO FOR ALL ISOLATED POST AND CONTINUOUS WALL
<br />FOOTINGS, SLABS -ON -GRADE, AND BASEMENT WALLS EXTENDING NO MORE THAN 8" ABOVE FINISH GRADE
<br />ELEVATION. FOR BASEMENT WALLS EXTENDING MORE THAN 8" ABOVE FINISH GRADE AND ALL SITE WALLS,
<br />PROVIDE A 5-1/2 SACK MINIMUM PC = 3,000 PSI CONCRETE MIX WITH MAXIMUM 3/4" AGGREGATE AND 0.50
<br />W/C RATIO.
<br />MIX DESIGN NOTES:
<br />(1) W/C RATIO: WATER-CEMENTITIOUS MATERIAL RATIOS SHALL BE BASED ON THE TOTAL WEIGHT OF
<br />CEMENTITIOUS MATERIALS.
<br />(2) CEMENTIDOUS CONTENT: THE USE OF FLY ASH, OTHER POZZOLANS, SILICA FUME, OR SLAG SHALL
<br />CONFORM TO ACI 301 SEC 4.2.2.8.B. MAXIMUM AMOUNT OF FLY ASH SHALL BE 20% OF TOTAL
<br />CEMENTITIOUS CONTENT UNLESS REVIEWED AND APPROVED OTHERWISE BY SER.
<br />(3) AIR CONTENT: CONFORM TO ACI 301 SEC 4.2.2.4. HORIZONTAL EXTERIOR SURFACES IN CONTACT WITH THE
<br />SOIL REQUIRE ENTRAINED AIR. USE "MODERATE EXPOSURE". VERTICAL EXTERIOR SURFACES REQUIRE
<br />"MODERATE EXPOSURE". TOLERANCE IS ♦/- 1-1/27. AIR CONTENT SHALL BE MEASURED AT POINT OF
<br />PLACEMENT.
<br />(4) SLUMP: CONFORM TO ACI 301 SEC 4.2.2.2. SLUMP SHALL BE DETERMINED AT POINT OF PLACEMENT.
<br />(5) NON -CHLORIDE ACCELERATOR: NON -CHLORIDE ACCELERATING ADMIXTURE MAY BE USED IN CONCRETE
<br />SLABS PLACED AT AMBIENT TEMPERATURES BELOW 5OF AT ME CONTRACTOR'S OPTION.
<br />FORMWORK CONFORM TO ACI 301 SEC 2 "FORMWORK AND FORM ACCESSORIES." REMOVAL OF FORMS SHALL
<br />CONFORM TO SEC 2.3.2 EXCEPT STRENGTH INDICATED IN SEC 2.3.2.5 SHALL BE 0.75 PC.
<br />MEASURING, MIXING. AND DEUVERY: CONFORM TO ACI 301 SEC 4.3.
<br />HANDLING, PLACING, CONSTRUCTING AND CURING: CONFORM TO ACI 301 SEC 5.
<br />REBAR FABRICATION & PLACING: CONFORM TO ACI 301, SEC 3.2.2 "FABRICATION', AND ACI SP-66 "ACI
<br />DETAILING MANUAL.' CONFORM TO ACI 301, SEC 3.3.2 "PLACEMENT." PLACING TOLERANCES SHALL CONFORM TO
<br />SEC 3.3.2.1 "TOLERANCES."
<br />SPLICES: CONFORM TO ACI 301, SEC 3.3.2.7. REFER TO PLANS FOR TYPICAL SPLICES.
<br />FIELD BENDING: CONFORM TO ACI 301 SEC 3.3.2.8. "FIELD BENDING OR STRAIGHTENING." BAR SIZES #3 THROUGH
<br />#5 MAY BE FIELD BENT COLD ME FIRST TIME. OTHER BARS REQUIRE PREHEATING. DO NOT TWIST BARS,
<br />CORNERS BARS: PROVIDE MATCHING -SIZED "C CORNER BARS FOR ALL HORIZONTAL WALL AND FOOTING BARS
<br />WITH THE APPROPRIATE SPLICE LENGTH, ONO.
<br />CONCRETE COVER: CONFORM TO THE FOLLOWING COVER REQUIREMENTS FROM ACI 301, TABLE 3.3.2.3:
<br />CONCRETE CAST AGAINST EARTH 3"
<br />CONCRETE EXPOSED TO EARTH OR WEATHER (#5 & SMALLER) 1-1/2-
<br />BARS IN SLABS AND WALLS 31C
<br />CONSTRUCTION JOINTS: CONFORM TO ACI 301 SEC 2.2.2.5, 5.1.2.3A, 5.2.2.1, AND 5.3.2.6. CONSTRUCTION JOINTS
<br />SHALL BE LOCATED AND DETAILED AS ON ME CONSTRUCTION DRAWINGS. USE OF AN ACCEPTABLE ADHESIVE,
<br />SURFACE RETARDER, PORTLAND CEMENT GROUT, OR ROUGHENING THE SURFACE IS NOT REQUIRED UNLESS
<br />SPECIFICALLY NOTED ON THE DRAWINGS. WHERE SHEAR BOND IS REQUIRED, ROUGHEN SURFACES TO 1/4°
<br />AMPUTUDE.
<br />@RRQr7tlY_\SIN[N
<br />REFERENCE STANDARDS: CONFORM TO-
<br />(1) IBC CHAPTER 23 "WOOD
<br />(2) NOS AND NOS SUPPLEMENT - "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION",
<br />(3) ANSI/TPI 1 "NATIONAL DESIGN STANDARD FOR METAL -PLATE -CONNECTED WOOD TRUSS CONSTRUCTION",
<br />DEFERRED SUBMITTALS: SUBMIT PRODUCT DATA AND PROOF OF ICC APPROVAL FOR FRAMING MEMBERS AND
<br />FASTENERS THAT HAVE BEEN DESIGNED BY OTHERS. SUBMIT CALCULATIONS PREPARED BY THE SSE IN THE
<br />STATE OF WASHINGTON FOR ALL MEMBERS AND CONNECTIONS DESIGNED BY OTHERS ALONG WITH SHOP
<br />DRAWINGS. ALL NECESSARY BRIDGING, BLOCKING, BLOCKING PANELS AND WEB STIFFENERS SHALL BE DETAILED
<br />AND FURNISHED BY ME SUPPLIER, TEMPORARY AND PERMANENT BRIDGING SHALL BE INSTALLED IN
<br />CONFORMANCE W M THE MANUFACTURER'S SPECIFICATIONS. DEFLECTION LIMITS SHALL BE AS NOTED UNDER
<br />DESIGN LOADS SECTION.
<br />IDENTIFICATION: ALL SAWN LUMBER AND PRE -MANUFACTURED WOOD PRODUCTS SHALL BE IDENTIFIED BY THE
<br />GRADE MARK OR A CERTIFICATE OF INSPECTION ISSUED BY THE CERTIFYING AGENCY
<br />- SAWN LUMBER: CONFORM TO GRADING RULES OF WWPA, WCUB OR NLGA. FINGER JOINTED STUDS
<br />ACCEPTABLE AT INTERIOR WALLS ONLY.
<br />MEMBER USE SIZE SPECIES GRADE
<br />STUDS & POSTS 2x, 4x HEM -FIR NO, 2
<br />RAFTERS 2x4 - SAO HEM -FIR NO. 2
<br />BEAMS 4x8 - 4x12 HEM -FIR NO. 2
<br />BEAMS 6x8 - 602 HEM -FIR NO. 2
<br />POSTS & TIMBERS 6x, 8x DOUG-FIR NO. 2
<br />- GLUED LAMINATED TIMBER: CONFORM TO AITC 117 "STANDARD SPECIFICATIONS FOR STRUCTURAL
<br />GLUE -LAMINATED TIMBER OF SOFTWOOD SPECIES, MANUFACTURING AND DESIGN- AND ANSI/AITC A190.1
<br />°STRUCTURAL GLUED LAMINATED TIMBER." CAMBER ALL GLUED LAMINATED MEMBERS BEAMS TO 2000,
<br />RADIUS, UNLESS SHOWN OTHERWISE ON THE PLANS,
<br />MEMBER USE SIZES SPECIES STRESS CLASS USES
<br />BEAMS ALL DF DF 24F-1.8E SIMPLE SPANS
<br />ALL DF/DF 24F-1.8E [(-FB)=(+FB)] CANTILEVER SPANS
<br />- METAL PLATE CONNECTED WOOD ROOF TRUSSES: CONFORM TO IBC SEC 2303.4 "TRUSSES,°
<br />- WOOD STRUCTURAL SHEATHING (PLYWOOD): WOOD APA-RATED STRUCTURAL SHEATHING INCLUDES: ALL
<br />VENEER PLYWOOD, ORIENTED STRAND BOARD, WAFERBOARD, PARTICLEBOARD, T1-11 SIDING, AND
<br />COMPOSITES OF VENEER AND WOOD BASED MATERIAL. CONFORM TO PRODUCT STANDARDS PS-1 AND PS-2
<br />OF THE U.S. DEPT. OF COMMERCE AND THE AMERICAN PLYWOOD ASSOCIATION (APA).
<br />MINIMUM APA RATING
<br />LOCATION THICKNESS TI
<br />ROOF 15/32" 32/16 C-D 1
<br />FLOOR 23/32" T&G 24 OC STURD-I-FLOOR 1
<br />WALLS 15/32" 32/16 C-D 1
<br />WALLS(ALT) 7/16" OSB 24/16 C-D 1
<br />- JOIST HANGERS AND CONNECTORS: SHALL BE 'STRONG TIE" BY SIMPSON COMPANY OR USE EQUIVALENT AS
<br />SPECIFIED IN THEIR LATEST CATALOGS. ALTERNATE CONNECTORS BY OTHER MANUFACTURERS MAY BE
<br />SUBSTITUTED PROVIDED THEY HAVE CURRENT ICC APPROVAL FOR EQUIVALENT OR GREATER LOAD
<br />CAPACITIES AND ARE REVIEWED AND APPROVED BY THE SER PRIOR TO ORDERING. CONNECTORS SHALL BE
<br />INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS,
<br />PLACE 1/2 OF THE NAILS OR BOLTS IN EACH MEMBER. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF
<br />ALL BOLTS AND LAG SCREWS BEARING ON WOOD. UNLESS NOTED OTHERWISE ALL NAILS SHALL BE FULL
<br />LENGTH COMMON. NAIL STRAPS TO WOOD FRAMING AS LATE AS POSSIBLE IN THE FRAMING PROCESS TO
<br />ALLOW ME WOOD TO SHRINK AND THE BUILDING TO SETTLE.
<br />- NAILS AND STAPLES: CONFORM TO IBC SEC 2303.6 "NAILS AND STAPLES." UNLESS NOTED ON PLANS, NAIL
<br />PER IBC TABLE 2304.9.1. UNLESS NOTED OTHERWISE ALL NAILS SHALL BE COMMON. NAIL SIZES SPECIFIED
<br />ON THE DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS:
<br />8d 2-1/2" 0.131"
<br />10d 3" 0.148"
<br />(8d & 10d ALTERNATIVE) PASLODE TETRAGRIP NAILS 2-3/8" 0.113"
<br />12d (16d SINKER) 3-1/4" 0.148"
<br />16d 3-1/2" 0.162"
<br />LAG BOLTS/BOLTS: CONFORM TO ASTM A307,
<br />NAILING REQUIREMENTS: PROVIDE MINIMUM NAILING IN ACCORDANCE "M IBC TABLE 2304.9.1 "FASTENING
<br />SCHEDULE" EXCEPT AS NOTED ON THE DRAWINGS. NAILING FOR ROOF/FLOOR DIAPHRAGMS/SHEAR WALLS SHALL
<br />BE PER DRAWINGS. NAILS SHALL BE DRIVEN FLUSH AND SHALL NOT FRACTURE THE SURFACE OF SHEATHING.
<br />STANDARD LIGHT -FRAME CONSTRUCTION: UNLESS NOTED ON THE PLANS, CONSTRUCTION SHALL CONFORM TO IBC
<br />SEC 2308 'CONVENTIONAL LIGHT -FRAME CONSTRUCTION" AND IBC SEC 2304 'GENERAL CONSTRUCTION
<br />REOUIREMENTS.'
<br />(1) WALL FRAMING: UNLESS OTHERWISE NOTED, ALL INTERIOR WALLS SHALL BE 2X4 0 16"OC AND ALL
<br />EXTERIOR WALLS SHALL BE 2X6 0 160OC. PROVIDE (2)BUNDLED STUDS MIN AT WALL ENDS AND EACH
<br />SIDE OF ALL OPENINGS. ONO, ALL SOLID SAWN LUMBER HEADERS SHALL BE SUPPORTED BY A MINIMUM
<br />OF E)TRIM AND (1)KING STUD AND ALL GLULAM OR ENGINEERED WOOD HEADERS BY (2)TRIM AND
<br />(2)KING STUDS. AT FRAMED WALLS, UNO, ALL SOLD SAWN LUMBER BEAMS SHALL BE SUPPORTED ON A
<br />MINIMUM OF (2) BUNDLED 2X STUDS AND ALL GLULAM OR ENGINEERED WOOD BEAMS ON A MINIMUM OF
<br />(3) BUNDLED 2X STUDS, STITCH -NAIL BUNDLED STUDS WITH (2)10D 0 1YOC. ONO, ALL INTERIOR AND
<br />EXTERIOR HEADERS SHALL BE OR. PROVIDE SOLID BLOCKING THEO FLOORS TO SUPPORTS BELOW FOR
<br />BEARING WALLS AND POSTS. ONO, ATTACH BOTTOM PLATES OF STUD WALLS TO WOOD FRAMING BELOW
<br />WITH 16D 0 12"OC OR TO CONCRETE WITH 5/8"-DIA. ANCHOR BOLTS X 7" EMBEDMENT AT 48.00. REFER
<br />TO SHEAR WALL SCHEDULE FOR SPECIFIC SHEATHING, STUD, AND NAILING REQUIREMENTS AT SHEAR
<br />WALLS. UNO, PROVIDE GYPSUM SHEATHING ON INTERIOR SURFACES AND PLYWOOD SHEATHING ON
<br />EXTERIOR SURFACES.
<br />(2) ROOFALOOR FRAMING: UNLESS OTHERWISE NOTED, PROVIDE DOUBLE JOISTS/RAFTERS UNDER ALL
<br />PARALLEL BEARING PARTITIONS AND SOUD BLOCKING AT ALL BEARING POINTS. PROVIDE DOUBLE JOISTS
<br />AROUND ALL ROOF/FLOOR OPENINGS. ONO, MULTI-JOISTS/RAFTERS SHALL BE STITCH -NAILED TOGETHER
<br />WITH (2)10D 0 12"OC. PROVIDE ROOF SHEATHING EDGE CUPS CENTERED BETWEEN FRAMING AT
<br />UNBLOCKED PLYWOOD EDGES. ALL FLOOR SHEATHING SHALL HAVE TONGUE AND GROOVE JOINTS OR BE
<br />SUPPORTED BY SOLD BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF ROOF/FLOOR
<br />SHEATHING. ROOF/FLOOR SHEATHING SHALL BE LAID FACE GRAIN PERPENDICULAR TO FRAMING MEMBERS.
<br />MOISTURE CONTENT: WOOD MATERIAL USED FOR THIS PROJECT SHALL HAVE MAXIMUM MOISTURE CONTENT OF
<br />19% EXCEPT FOR THE PRESSURE -TREATED WOOD SILL PLATE.
<br />PRESERVATIVE TREATMENT: WOOD MATERIALS ARE REQUIRED TO BE 'TREATED WOOD" UNDER CERTAIN
<br />CONDITIONS IN ACCORDANCE WITH IBC SEC 2304.11 "PROTECTION AGAINST DECAY AND TERMITES". CONFORM TO
<br />ME APPROPRIATE STANDARDS OF THE AMERICAN WOOD -PRESERVERS ASSOCIATION (AMA) FOR SANK LUMBER,
<br />GLUED LAMINATED TIMBER, ROUND POLES, WOOD PILES AND MARINE PILES. FOLLOW AMERICAN LUMBER
<br />STANDARDS COMMITTEE (ALSC) QUALITY ASSURANCE PROCEDURES. PRODUCTS SHALL BEAR THE APPROPRIATE
<br />MARK.
<br />METAL CONNECTORS/PT WOOD: CK ENGINEERING LLC RECOMMENDS THAT ALL METAL HARDWARE AND FASTENERS
<br />IN CONTACT WITH PRESSURE TREATED LUMBER BE STAINLESS STEEL TYPE 316L. AT THE OWNER'S RISK AND
<br />DISCRETION, HOT -DIPPED GALVANIZED METAL HARDWARE AND FASTENERS MAY BE INVESTIGATED FOR USE IN LIEU
<br />OF STAINLESS STEEL PROVIDED THAT THE FINISH HAS A MINIMUM ZINC CONTENT OF AT LEAST 1,85 OZ/SF AND
<br />ITS USE IS COORDINATED BY THE CONTRACTOR AND WOOD SUPPLIER FOR THE EXPECTED ENVIRONMENT AND
<br />MOISTURE EXPOSURE FOR APPROPRIATE USE BASED ON THE METHOD OF PRESERVATIVE TREATMENT OF THE
<br />WOOD.
<br />DETAILA
<br />PIiIt1111111:1
<br />DETAIL C
<br />MODEL
<br />END STUD
<br />CAPACITY(LBS)
<br />ANCHORAGE TYPE I.,x.1
<br />FASTENERS
<br />DOUG-FIR
<br />HEM -FIR
<br />#,,,
<br />REQUIRED
<br />C514
<br />FUR-TO-FUR
<br />STRAP (El.
<br />(30) 10d COMMON
<br />2x STUD
<br />2,490
<br />2,490
<br />LSTHDS/RJ
<br />CAST -IN -PLACE
<br />(16) 16d SINKERS
<br />(2) 2x STUDST
<br />1,975
<br />1,975
<br />STHD14/RJ
<br />CAST -IN -PLACE
<br />(22) 16d SINKERS
<br />(2) 2x STUDS
<br />3,695
<br />3,695
<br />HDU8
<br />SSTB28
<br />(20) '/4 0x21/4
<br />(3) 2, STUDS
<br />7,870
<br />5,665
<br />SDS WOOD SCREWS
<br />NOTES:
<br />1. HOEDOWNS SPECIFIED ARE AS MANUFACTURED BY SIMPSON ANCHOR TIE DOWN CO., ING: ACCEPTABLE
<br />EQUIVALENT PRODUCT SUBSTITUTIONS ARE AVAILABLE FROM OTHER MANUFACTURERS WITH SER APPROVAL.
<br />2. LOCATE ALL HOEDOWNS AT ENDS OF ALL SHEAR WALLS & FASTEN TO BUNDLED END STUDS.
<br />3. BUNDLED END STUDS SHOULD BE STITCH -NAILED TOGETHER USING MINIMUM (2) 16d 0 10"OC, LINO.
<br />4. LOCATE "HDU#°, "LSTHD#" & "STHD#" HOEDOWNS AT CONCRETE FOUNDATION LEVEL (DETAIL B & C)
<br />LOCATE "CS# 'MST", "MSTC#" & "CMST#" STRAPS AT FLOOR -TO -FLOOR CONNECTIONS. (DETAIL A)
<br />5. ALL HOEDOWN ANCHOR BOLTS SHALL BE MIN 5" FROM CONCRETE WALL ENDS.
<br />6. USE "SSTB" FOR 2x SILL PLATES & "SSTBL" FOR 3x SILL PLATES.
<br />7. ADDITIONAL END STUD REQUIRED TO MEET MINIMUM 11/p" EDGE DISTANCE FROM CONCRETE CORNER TO "STHD" STRAP.
<br />USE "RJ" STYLE WITH "STIED" WHERE RIM JOIST IS PRESENT.
<br />8. INSTALL All HOEDOWN HARDWARE PER MANUFACTURER'S INSTRUCTIONS & RECOMMENDATIONS.
<br />HOLDOWN SCHEDULE
<br />SCALE: N.T.S.
<br />WOOD -FRAMED SHEAR WALL SCHEDULE
<br />FOR HEM-FIRIDOUI STUD FRAMING
<br />BOTTOM PLATE & EDGE MEMBER
<br />SILL PLATE REQUIREMENTS
<br />SW
<br />SW SHEATHING
<br />NAIL SIZE &
<br />RIM JOIST OR BLOCKING
<br />REQUIREMENTS
<br />SHEAR LOAD
<br />SHEAR NAILING TO
<br />8070M It
<br />ANCHOR BOLT TO
<br />SILL It AT
<br />TYPE
<br />APA-RATED
<br />SPACING 0 PANEL EDGES
<br />ATTACHMENT TO
<br />TOP PLATE BELOW
<br />CAPACITY (ELF)
<br />WOOD FRAMING BELOW
<br />AT FRAMING
<br />CONCRETE FOUNDATION
<br />FOUNDATION
<br />1. 2 121
<br />N 5. 61
<br />18.91
<br />110111
<br />SW-6
<br />15/32" CD-EXT
<br />0.131"e x 21/2"
<br />CLIP 0 18"OC
<br />0.148"e x 31/4" 0 6"OC
<br />2x
<br />6g
<br />/.e 0 48"OC
<br />P.T. 2x
<br />260
<br />0 6"OC
<br />SW-2
<br />15 32° CD-EXT
<br />/
<br />0.131"e x 21/2"
<br />CLIP 0 COG
<br />0.148"e x 31/4" 0 4"OC
<br />3x
<br />5 /g"0 0 24"OC
<br />P.T. 3x
<br />640
<br />0 2"OC, STAGGERED
<br />& CLIP 0 16"OC
<br />Is
<br />Is
<br />NOTES
<br />1. INSTALL PANELS EITHER HORIZONTALLY OR VERTICALLY
<br />2. WHERE SHEATHING IS APPUED ON BOTH SIDES OF WALL, PANEL EDGE JOINTS ON 2x FRAMING
<br />SHALL BE STAGGERED SO THAT JOINTS ON OPPOSITE SIDES ARE NOT LOCATED ON THE SAME
<br />STUDS.
<br />3. BLOCKING IS REQUIRED AT ALL PANEL EDGES.
<br />4. PROVIDE SHEAR WALL SHEATHING AND NAILING FOR ENTIRE LENGTH OF THE WALLS INDICATED ON
<br />THE PLANS. ENDS OF FULL HEIGHT WALLS ARE DESIGNATED BY WINDOWS, OR DOORWAYS OR AS
<br />DESIGNATED ON PUNS. HOEDOWN REQUIREMENTS PER PLANS.
<br />5. SHEAR WALLS DESIGNATED AS PERFORATED SHEAR WALLS REQUIRE SHEATHING, SHEAR WALL NAILING,
<br />ETC. ABOVE AND BELOW ALL OPENINGS).
<br />6. SHEATHING EDGE NAILING IS REQUIRED AT ALL HOEDOWN POSTS. EDGE NAILING MAY ALSO BE
<br />REQUIRED TO EACH STUD USED IN BUILT-UP HOEDOWN POSTS. ADDITIONAL INFORMATION PER
<br />HOEDOWN SCHEDULE & DETAILS.
<br />7. INTERMEDIATE FRAMING TO BE 2x MINIMUM MEMBERS. ATTACH SHEATHING TO INTERMEDIATE FRAMING
<br />WITH 0.148"0 x 21/2" NAILS AT 12.00 WHERE STUDS ARE SPACED AT 16.00 AND 0.148"0 x 21/2"
<br />NAILS AT COG WHERE STUDS ARE SPACED AT 2410C.
<br />S. BASED ON OU31"0 x 11/q" NAILS USED TO ATTACH FRAMING CUPS DIRECTLY TO FRAMING. USE
<br />0.13110 x 21/2" NAILS WHERE INSTALLED OVER SHEATHING.
<br />9. FRAMING CLIPS: SIMPSON 'A35" OR 175" OR APPROVED EQUIVALENT.
<br />WOOD -FRAMED SHEAR WALL SCHEDULE
<br />SCALE N.T.S
<br />10. ANCHOR BOLTS SHALL BE PROVIDED WITH HOT -DIPPED GALVANIZED STEEL PLATE WASHERS
<br />3"x3"xO.229"(MIN). THE HOLE IN THE PLATE WASHER MAY BE DIAGONALLY SLOTTED 13/I6:13/p
<br />PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND NUT. PLATE
<br />WASHER TO EXTEND TO WITHIN I/y" OF THE EDGE OF THE SILL PLATE ON THE SIDES) WITH
<br />SHEATHING. WHERE SHEAR WALLS ARE SHEATHED ON BOTH SIDES OF 2x6 WALL FRAMING, USE
<br />45"x4.5"xO.229"(MIN) PLATE WASHERS. EMBED ANCHOR BOLTS 7" MINIMUM INTO THE CONCRETE.
<br />11. PRESSURE TREATED MATERIAL CAN CAUSE EXCESSIVE CORROSION IN THE FASTENERS. PROVIDE
<br />HOT -DIPPED GALVANIZED (ELECTRO-PLATING IS NOT ACCEPTABLE) NAILS AND CONNECTOR PLATES
<br />(FRAMING ANGLES, ETC.) FOR ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED FRAMING
<br />MEMBERS. ADDITIONAL INFORMATION PER STRUCTURAL NOTES.
<br />12. WHERE WOOD SHEATHING IS APPLIED OVER GYPSUM SHEATHING, CONTACT THE ENGINEER OF RECORD
<br />FOR ALTERNATE NAILING REQUIREMENTS.
<br />13. AT ADJOINING PANEL EDGES, (2) 2x STUDS NAILED TOGETHER MAY BE USED IN PUCE OF SINGLE 3x
<br />STUD. DOUBLE 2X STUDS SHALL BE CONNECTED TOGETHER BY NAIUNG THE STUDS TOGETHER WITH
<br />3' LONG NAILS OF THE SAME SPACING AND DIAMETER AS THE PLATE NAILING.
<br />14, CONTACT THE STRUCTURAL ENGINEER OF RECORD FOR ADHESIVE OR EXPANSION BOLT ALTERNATIVES
<br />TO CAST -IN -PLACE ANCHOR BOLTS. SPECIAL INSPECTION MAY BE REQUIRED.
<br />15. NAIL STUDS TO 3x BOT7OM/SILL PLATES WITH EITHER (2) 0.148'Ox4" END NAILS OR
<br />(4) 0.13170x21/2" TOENAILS.
<br />cV�bV� N* gB�`b'
<br />ca
<br />o s�t04z15 G�
<br />�`t'ONA4
<br />12/16/2020
<br />LU
<br />CD
<br />NQ
<br />I L
<br />Q
<br />00
<br />P
<br />Q
<br />0a
<br />z3
<br />/vF'�
<br />CN
<br />�
<br />Q/V
<br />aQui
<br />w
<br />O
<br />a
<br />U
<br />w
<br />0
<br />w
<br />0
<br />a
<br />0
<br />h
<br />w
<br />Drawn By: PK
<br />Checked By: SC
<br />Date: 12-16-2020
<br />CK JOB NO.
<br />20-044
<br />STRUCTURAL
<br />NOTES//SCHED.
<br />S-1.0