[It 1:i111iill iL1a#ULm9 <br />BUILDING CODE & REFERENCE STANDARDS: THE "INTERNATIONAL BUILDING CODE", 2015 EDITION, GOVERNS THE <br />DESIGN AND CONSTRUCTION OF THIS PROJECT. REFERENCE TO A SPECIFIC SECTION IN THE CODE DOES NOT <br />RELIEVE THE CONTRACTOR FROM COMPLIANCE )NTH THE ENTIRE MATERIALS REFERENCE STANDARDS NOTED <br />BELOW. THE LATEST EDITION OF THE MATERIALS REFERENCE STANDARDS SHALL BE USED. <br />ARCHITECTURAL DRAWINGS: REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION INCLUDING, BUT NOT <br />LIMITED T0: DIMENSIONS, ELEVATIONS, SLOPES, DOOR AND WINDOW OPENINGS, NON -BEARING WALLS, STAIRS, <br />CURBS, DRAINS, DEPRESSIONS, RAILINGS, WATERPROOFING, FINISHES AND OTHER NONSTRUCTURAL ITEMS. <br />STRUCTURAL RESPONSIBIUTIES: THE PE IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE PRIMARY <br />STRUCTURE IN ITS COMPLETED STATE. <br />CONTRACTOR RESPONSIBILITIES: THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF <br />CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA AND WSHA. THE CONTRACTOR IS <br />RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE STRUCTURE DURING CONSTRUCTION AND SHALL PROVIDE <br />TEMPORARY SHORING, BRACING AND OTHER ELEMENTS REQUIRED TO MAINTAIN STABILITY UNTIL THE STRUCTURE <br />IS COMPLETED. IT IS THE CONTRACTOR'S RESPONSIBUTY TO BE FAMILIAR WITH THE WORK REQUIRED IN THE <br />CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR EXECUTING IT PROPERLY, <br />DISCREPANCIES: IN CASE OF DISCREPANCIES BETWEEN THESE GENERAL NOTES, THE CONTRACT DRAWINGS AND <br />SPECIFICATIONS, AND/OR REFERENCE STANDARDS, THE ENGINEER SHALL DETERMINE WHICH SHALL GOVERN, <br />DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK. <br />SITE VERIFICATION: THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO <br />FABRICATION AND/OR CONSTRUCTION. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL <br />BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ALL UNDERGROUND <br />UTILITIES SHALL BE DETERMINED BY ME CONTRACTOR PRIOR TO EXCAVATION OR DRILLING. <br />WIND DESIGN: BASIC WIND SPEED (3-SECOND GUST), V = 85 MPH(ASD} WIND IMPORTANCE FACTOR, IW = <br />1.0; OCCUPANCY CATEGORY = II; EXPOSURE CATEGORY = D; <br />SEISMIC DESIGN: SEISMIC IMPORTANCE FACTOR IE 1.0; OCCUPANCY CATEGORY = II; SS = 1.279G; S1 = <br />0.487G; SITE CLASS = D; SDS = 0.853G; SDI = 0.491G; SEISMIC DESIGN CATEGORY = D; <br />BASIC SEISMIC FORCE RESISTING SYSTEM = A-13 (BEARING WALL SYSTEMS) LIGHT -FRAMED <br />WALLS WITH WOOD STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE; CS = 0.092; R = <br />6.5; ANALYSIS PROCEDURE = EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7, SEC 12.8. <br />SNOW LOAD: GROUND SNOW LOAD, PG = 25 PSF; FLAT ROOF SNOW LOAD, PF = 25 PER (DRIFT LOADS <br />CONSIDERED PER ASCE 7 WHERE APPLICABLE); SNOW EXPOSURE FACTOR, CE = 1.0; SNOW <br />IMPORTANCE FACTOR, IS = 1.0, THERMAL FACTOR, CT = 1.0. <br />LIVE LOADS: ROOF (LIVE) 20 PSF <br />ROOF (SNOW) 25 ESE <br />RESIDENTIAL FLOOR 40 PER <br />RESIDENTIAL DECK 60 PER <br />DEFERRED SUBMITTALS: ITEMS DESIGNED BY OTHERS SHALL INCLUDE CALCULATIONS, SHOP DRAWINGS AND <br />PRODUCT DATA. DESIGN SHALL BE PREPARED BY THE SSE AND SUBMITTED TO THE ARCHITECT AND PE FOR <br />REVIEW PRIOR TO SUBMISSION TO THE JURISDICTION FOR APPROVAL. THE SSE SHALL SUBMIT TO THE ENGINEER <br />FOR RENEW CALCULATIONS AND SHOP DRAWINGS THAT ARE STAMPED AND SIGNED BY THE SSE. RENEW OF ME <br />SEE'S SHOP DRAWINGS IS FOR GENERAL COMPLIANCE WITH DESIGN CRITERIA AND COMPATIBILITY WITH THE DESIGN <br />OF THE PRIMARY STRUCTURE AND DOES NOT REUEVE THE SSE OF RESPONSIBILITY FOR THAT DESIGN. ALL <br />NECESSARY BRACING, TIES, ANCHORAGE, AND PROPRIETARY PRODUCTS SHALL BE FURNISHED AND INSTALLED PER <br />MANUFACTURER'S INSTRUCTIONS OR THE SSE'S DESIGN DRAWINGS AND CALCULATIONS. <br />INSPECTIONS: ALL CONSTRUCTION IS SUBJECT TO INSPECTION BY THE BUILDING OFFICIAL IN ACCORDANCE WITH <br />IBC SEC 109. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED INSPECTIONS WITH THE BUILDING OFFICIAL. <br />SUBMIT COPIES OF ALL INSPECTION REPORTS TO THE ENGINEER FOR REVIEW. <br />PREFABRICATED CONSTRUCTION: ALL PREFABRICATED CONSTRUCTION SHALL CONFORM TO IBC SEC 1703.6. <br />GEOTECHNICAL INSPECTION: THE GEOTECHNICAL ENGINEER OR BUILDING OFFICIAL SHALL INSPECT ALL PREPARED <br />SOIL BEARING SURFACES PRIOR TO PLACEMENT OF CONCRETE AND REINFORCING STEEL AND PROVIDE A LETTER <br />TO ME OWNER STATING THAT SOILS ARE ADEQUATE TO SUPPORT THE "ALLOWABLE FOUNDATION PRESSURE" <br />SHOWN BELOW. SOIL VALUES SHALL BE FIELD VERIFIED BY THE BUILDING OFFICIAL OR THE GEOTECHNICAL <br />ENGINEER PRIOR TO PLACING CONCRETE. <br />DESIGN SOIL VALUES: <br />ALLOWABLE BEARING PRESSURE (ASSUMED) 1500 PER <br />PASSIVE LATERAL PRESSURE 150 PSF/FT <br />ACTIVE LATERAL PRESSURE (UNRESTRAINED) 35 PSF/FT <br />ACTIVE LATERAL PRESSURE (RESTRAINED) 50 PSF/FT <br />COEFFICIENT OF SLIDING FRICTION 0.25 <br />SLABS -ON -GRADE & FOUNDATIONS: ALL FOUNDATIONS SHALL BEAR ON STRUCTURAL COMPACTED FILL OR <br />COMPETENT NATIVE SOIL PER THE GEOTECHNICAL REPORT. ALL SLABS -ON -GRADE SHALL BE FOUNDED ON <br />APPROPRIATE SUB -GRADE PREPARATION AS NOTED IN THE GEOTECHNICAL REPORT. EXTERIOR PERIMETER <br />FOOTINGS SHALL BEAR NOT LESS THAN 18 INCHES BELOW FINISH GRADE, OR BY ME GEOTECHNICAL ENGINEER <br />AND THE BUILDING OFFICIAL. INTERIOR FOOTINGS SHALL BEAR NOT LESS THAN 12 INCHES BELOW FINISH FLOOR. <br />COMPACTION: UNLESS OTHERWISE SPECIFIED BY A GEOTECHNICAL ENGINEER, FOOTINGS SHALL BE PLACED ON <br />COMPACTED MATERIAL AND SHALL BE WELL -GRADED GRANULAR MATERIAL WITH NO MORE THAN 5% PASSING A <br />#2 SIEVE. HILLS PLACED SHALL BE IN MAXIMUM 8" LIFTS AND ALL BEARING SOILS SHALL BE COMPACTED TO 957 <br />MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT USING THE MODIFIED PROCTOR TEST. <br />CAST -IN -PLACE CONCRETE & REINFORCEMENT <br />REFERENCE STANDARDS: CONFORM TO: <br />(1) ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY". <br />(2) IBC CHAPTER 19. <br />(3) ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE", SEC 3 "REINFORCEMENT AND <br />REINFORCEMENT SUPPORTS.° <br />FIELD REFERENCE: THE CONTRACTOR SHALL KEEP A COPY OF ACI FIELD REFERENCE MANUAL, SP-15, "STANDARD <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301) WM SELECTED ACI AND ASTM REFERENCES." <br />CONCRETE MIXTURES: CONFORM TO ACI 318 CHAPTER 5 "CONCRETE QUALITY, MIXING, AND PLACING." <br />MATERIALS: CONFORM TO ACI 318 CHAPTER 3 "MATERIALS" FOR REQUIREMENTS FOR CEMENDTOUS MATERIALS, <br />AGGREGATES, MIXING WATER AND ADMIXTURES. <br />REINFORCING BARS ASTM A615, GRADE 60, DEFORMED BARS. <br />DEFORMED WELDED WIRE FABRIC ASTM A497 <br />BAR SUPPORTS CRSI MSP-2, CHAPTER 3 "BAR SUPPORTS." <br />TIE WIRE 16.5 GAGE OR HEAVIER, BLACK ANNEALED. <br />MIX DESIGNS: PROVIDE A 5-SACK MINIMUM, 28-DAY COMPRESSIVE STRENGTH F'C = 2.500 PSI CONCRETE MIX <br />WITH MAXIMUM 3/4" AGGREGATE AND 0.50 W/C RATIO FOR ALL ISOLATED POST AND CONTINUOUS WALL <br />FOOTINGS, SLABS -ON -GRADE, AND BASEMENT WALLS EXTENDING NO MORE THAN 8" ABOVE FINISH GRADE <br />ELEVATION. FOR BASEMENT WALLS EXTENDING MORE THAN 8" ABOVE FINISH GRADE AND ALL SITE WALLS, <br />PROVIDE A 5-1/2 SACK MINIMUM PC = 3,000 PSI CONCRETE MIX WITH MAXIMUM 3/4" AGGREGATE AND 0.50 <br />W/C RATIO. <br />MIX DESIGN NOTES: <br />(1) W/C RATIO: WATER-CEMENTITIOUS MATERIAL RATIOS SHALL BE BASED ON THE TOTAL WEIGHT OF <br />CEMENTITIOUS MATERIALS. <br />(2) CEMENTIDOUS CONTENT: THE USE OF FLY ASH, OTHER POZZOLANS, SILICA FUME, OR SLAG SHALL <br />CONFORM TO ACI 301 SEC 4.2.2.8.B. MAXIMUM AMOUNT OF FLY ASH SHALL BE 20% OF TOTAL <br />CEMENTITIOUS CONTENT UNLESS REVIEWED AND APPROVED OTHERWISE BY SER. <br />(3) AIR CONTENT: CONFORM TO ACI 301 SEC 4.2.2.4. HORIZONTAL EXTERIOR SURFACES IN CONTACT WITH THE <br />SOIL REQUIRE ENTRAINED AIR. USE "MODERATE EXPOSURE". VERTICAL EXTERIOR SURFACES REQUIRE <br />"MODERATE EXPOSURE". TOLERANCE IS ♦/- 1-1/27. AIR CONTENT SHALL BE MEASURED AT POINT OF <br />PLACEMENT. <br />(4) SLUMP: CONFORM TO ACI 301 SEC 4.2.2.2. SLUMP SHALL BE DETERMINED AT POINT OF PLACEMENT. <br />(5) NON -CHLORIDE ACCELERATOR: NON -CHLORIDE ACCELERATING ADMIXTURE MAY BE USED IN CONCRETE <br />SLABS PLACED AT AMBIENT TEMPERATURES BELOW 5OF AT ME CONTRACTOR'S OPTION. <br />FORMWORK CONFORM TO ACI 301 SEC 2 "FORMWORK AND FORM ACCESSORIES." REMOVAL OF FORMS SHALL <br />CONFORM TO SEC 2.3.2 EXCEPT STRENGTH INDICATED IN SEC 2.3.2.5 SHALL BE 0.75 PC. <br />MEASURING, MIXING. AND DEUVERY: CONFORM TO ACI 301 SEC 4.3. <br />HANDLING, PLACING, CONSTRUCTING AND CURING: CONFORM TO ACI 301 SEC 5. <br />REBAR FABRICATION & PLACING: CONFORM TO ACI 301, SEC 3.2.2 "FABRICATION', AND ACI SP-66 "ACI <br />DETAILING MANUAL.' CONFORM TO ACI 301, SEC 3.3.2 "PLACEMENT." PLACING TOLERANCES SHALL CONFORM TO <br />SEC 3.3.2.1 "TOLERANCES." <br />SPLICES: CONFORM TO ACI 301, SEC 3.3.2.7. REFER TO PLANS FOR TYPICAL SPLICES. <br />FIELD BENDING: CONFORM TO ACI 301 SEC 3.3.2.8. "FIELD BENDING OR STRAIGHTENING." BAR SIZES #3 THROUGH <br />#5 MAY BE FIELD BENT COLD ME FIRST TIME. OTHER BARS REQUIRE PREHEATING. DO NOT TWIST BARS, <br />CORNERS BARS: PROVIDE MATCHING -SIZED "C CORNER BARS FOR ALL HORIZONTAL WALL AND FOOTING BARS <br />WITH THE APPROPRIATE SPLICE LENGTH, ONO. <br />CONCRETE COVER: CONFORM TO THE FOLLOWING COVER REQUIREMENTS FROM ACI 301, TABLE 3.3.2.3: <br />CONCRETE CAST AGAINST EARTH 3" <br />CONCRETE EXPOSED TO EARTH OR WEATHER (#5 & SMALLER) 1-1/2- <br />BARS IN SLABS AND WALLS 31C <br />CONSTRUCTION JOINTS: CONFORM TO ACI 301 SEC 2.2.2.5, 5.1.2.3A, 5.2.2.1, AND 5.3.2.6. CONSTRUCTION JOINTS <br />SHALL BE LOCATED AND DETAILED AS ON ME CONSTRUCTION DRAWINGS. USE OF AN ACCEPTABLE ADHESIVE, <br />SURFACE RETARDER, PORTLAND CEMENT GROUT, OR ROUGHENING THE SURFACE IS NOT REQUIRED UNLESS <br />SPECIFICALLY NOTED ON THE DRAWINGS. WHERE SHEAR BOND IS REQUIRED, ROUGHEN SURFACES TO 1/4° <br />AMPUTUDE. <br />@RRQr7tlY_\SIN[N <br />REFERENCE STANDARDS: CONFORM TO- <br />(1) IBC CHAPTER 23 "WOOD <br />(2) NOS AND NOS SUPPLEMENT - "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION", <br />(3) ANSI/TPI 1 "NATIONAL DESIGN STANDARD FOR METAL -PLATE -CONNECTED WOOD TRUSS CONSTRUCTION", <br />DEFERRED SUBMITTALS: SUBMIT PRODUCT DATA AND PROOF OF ICC APPROVAL FOR FRAMING MEMBERS AND <br />FASTENERS THAT HAVE BEEN DESIGNED BY OTHERS. SUBMIT CALCULATIONS PREPARED BY THE SSE IN THE <br />STATE OF WASHINGTON FOR ALL MEMBERS AND CONNECTIONS DESIGNED BY OTHERS ALONG WITH SHOP <br />DRAWINGS. ALL NECESSARY BRIDGING, BLOCKING, BLOCKING PANELS AND WEB STIFFENERS SHALL BE DETAILED <br />AND FURNISHED BY ME SUPPLIER, TEMPORARY AND PERMANENT BRIDGING SHALL BE INSTALLED IN <br />CONFORMANCE W M THE MANUFACTURER'S SPECIFICATIONS. DEFLECTION LIMITS SHALL BE AS NOTED UNDER <br />DESIGN LOADS SECTION. <br />IDENTIFICATION: ALL SAWN LUMBER AND PRE -MANUFACTURED WOOD PRODUCTS SHALL BE IDENTIFIED BY THE <br />GRADE MARK OR A CERTIFICATE OF INSPECTION ISSUED BY THE CERTIFYING AGENCY <br />- SAWN LUMBER: CONFORM TO GRADING RULES OF WWPA, WCUB OR NLGA. FINGER JOINTED STUDS <br />ACCEPTABLE AT INTERIOR WALLS ONLY. <br />MEMBER USE SIZE SPECIES GRADE <br />STUDS & POSTS 2x, 4x HEM -FIR NO, 2 <br />RAFTERS 2x4 - SAO HEM -FIR NO. 2 <br />BEAMS 4x8 - 4x12 HEM -FIR NO. 2 <br />BEAMS 6x8 - 602 HEM -FIR NO. 2 <br />POSTS & TIMBERS 6x, 8x DOUG-FIR NO. 2 <br />- GLUED LAMINATED TIMBER: CONFORM TO AITC 117 "STANDARD SPECIFICATIONS FOR STRUCTURAL <br />GLUE -LAMINATED TIMBER OF SOFTWOOD SPECIES, MANUFACTURING AND DESIGN- AND ANSI/AITC A190.1 <br />°STRUCTURAL GLUED LAMINATED TIMBER." CAMBER ALL GLUED LAMINATED MEMBERS BEAMS TO 2000, <br />RADIUS, UNLESS SHOWN OTHERWISE ON THE PLANS, <br />MEMBER USE SIZES SPECIES STRESS CLASS USES <br />BEAMS ALL DF DF 24F-1.8E SIMPLE SPANS <br />ALL DF/DF 24F-1.8E [(-FB)=(+FB)] CANTILEVER SPANS <br />- METAL PLATE CONNECTED WOOD ROOF TRUSSES: CONFORM TO IBC SEC 2303.4 "TRUSSES,° <br />- WOOD STRUCTURAL SHEATHING (PLYWOOD): WOOD APA-RATED STRUCTURAL SHEATHING INCLUDES: ALL <br />VENEER PLYWOOD, ORIENTED STRAND BOARD, WAFERBOARD, PARTICLEBOARD, T1-11 SIDING, AND <br />COMPOSITES OF VENEER AND WOOD BASED MATERIAL. CONFORM TO PRODUCT STANDARDS PS-1 AND PS-2 <br />OF THE U.S. DEPT. OF COMMERCE AND THE AMERICAN PLYWOOD ASSOCIATION (APA). <br />MINIMUM APA RATING <br />LOCATION THICKNESS TI <br />ROOF 15/32" 32/16 C-D 1 <br />FLOOR 23/32" T&G 24 OC STURD-I-FLOOR 1 <br />WALLS 15/32" 32/16 C-D 1 <br />WALLS(ALT) 7/16" OSB 24/16 C-D 1 <br />- JOIST HANGERS AND CONNECTORS: SHALL BE 'STRONG TIE" BY SIMPSON COMPANY OR USE EQUIVALENT AS <br />SPECIFIED IN THEIR LATEST CATALOGS. ALTERNATE CONNECTORS BY OTHER MANUFACTURERS MAY BE <br />SUBSTITUTED PROVIDED THEY HAVE CURRENT ICC APPROVAL FOR EQUIVALENT OR GREATER LOAD <br />CAPACITIES AND ARE REVIEWED AND APPROVED BY THE SER PRIOR TO ORDERING. CONNECTORS SHALL BE <br />INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, <br />PLACE 1/2 OF THE NAILS OR BOLTS IN EACH MEMBER. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF <br />ALL BOLTS AND LAG SCREWS BEARING ON WOOD. UNLESS NOTED OTHERWISE ALL NAILS SHALL BE FULL <br />LENGTH COMMON. NAIL STRAPS TO WOOD FRAMING AS LATE AS POSSIBLE IN THE FRAMING PROCESS TO <br />ALLOW ME WOOD TO SHRINK AND THE BUILDING TO SETTLE. <br />- NAILS AND STAPLES: CONFORM TO IBC SEC 2303.6 "NAILS AND STAPLES." UNLESS NOTED ON PLANS, NAIL <br />PER IBC TABLE 2304.9.1. UNLESS NOTED OTHERWISE ALL NAILS SHALL BE COMMON. NAIL SIZES SPECIFIED <br />ON THE DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: <br />8d 2-1/2" 0.131" <br />10d 3" 0.148" <br />(8d & 10d ALTERNATIVE) PASLODE TETRAGRIP NAILS 2-3/8" 0.113" <br />12d (16d SINKER) 3-1/4" 0.148" <br />16d 3-1/2" 0.162" <br />LAG BOLTS/BOLTS: CONFORM TO ASTM A307, <br />NAILING REQUIREMENTS: PROVIDE MINIMUM NAILING IN ACCORDANCE "M IBC TABLE 2304.9.1 "FASTENING <br />SCHEDULE" EXCEPT AS NOTED ON THE DRAWINGS. NAILING FOR ROOF/FLOOR DIAPHRAGMS/SHEAR WALLS SHALL <br />BE PER DRAWINGS. NAILS SHALL BE DRIVEN FLUSH AND SHALL NOT FRACTURE THE SURFACE OF SHEATHING. <br />STANDARD LIGHT -FRAME CONSTRUCTION: UNLESS NOTED ON THE PLANS, CONSTRUCTION SHALL CONFORM TO IBC <br />SEC 2308 'CONVENTIONAL LIGHT -FRAME CONSTRUCTION" AND IBC SEC 2304 'GENERAL CONSTRUCTION <br />REOUIREMENTS.' <br />(1) WALL FRAMING: UNLESS OTHERWISE NOTED, ALL INTERIOR WALLS SHALL BE 2X4 0 16"OC AND ALL <br />EXTERIOR WALLS SHALL BE 2X6 0 160OC. PROVIDE (2)BUNDLED STUDS MIN AT WALL ENDS AND EACH <br />SIDE OF ALL OPENINGS. ONO, ALL SOLID SAWN LUMBER HEADERS SHALL BE SUPPORTED BY A MINIMUM <br />OF E)TRIM AND (1)KING STUD AND ALL GLULAM OR ENGINEERED WOOD HEADERS BY (2)TRIM AND <br />(2)KING STUDS. AT FRAMED WALLS, UNO, ALL SOLD SAWN LUMBER BEAMS SHALL BE SUPPORTED ON A <br />MINIMUM OF (2) BUNDLED 2X STUDS AND ALL GLULAM OR ENGINEERED WOOD BEAMS ON A MINIMUM OF <br />(3) BUNDLED 2X STUDS, STITCH -NAIL BUNDLED STUDS WITH (2)10D 0 1YOC. ONO, ALL INTERIOR AND <br />EXTERIOR HEADERS SHALL BE OR. PROVIDE SOLID BLOCKING THEO FLOORS TO SUPPORTS BELOW FOR <br />BEARING WALLS AND POSTS. ONO, ATTACH BOTTOM PLATES OF STUD WALLS TO WOOD FRAMING BELOW <br />WITH 16D 0 12"OC OR TO CONCRETE WITH 5/8"-DIA. ANCHOR BOLTS X 7" EMBEDMENT AT 48.00. REFER <br />TO SHEAR WALL SCHEDULE FOR SPECIFIC SHEATHING, STUD, AND NAILING REQUIREMENTS AT SHEAR <br />WALLS. UNO, PROVIDE GYPSUM SHEATHING ON INTERIOR SURFACES AND PLYWOOD SHEATHING ON <br />EXTERIOR SURFACES. <br />(2) ROOFALOOR FRAMING: UNLESS OTHERWISE NOTED, PROVIDE DOUBLE JOISTS/RAFTERS UNDER ALL <br />PARALLEL BEARING PARTITIONS AND SOUD BLOCKING AT ALL BEARING POINTS. PROVIDE DOUBLE JOISTS <br />AROUND ALL ROOF/FLOOR OPENINGS. ONO, MULTI-JOISTS/RAFTERS SHALL BE STITCH -NAILED TOGETHER <br />WITH (2)10D 0 12"OC. PROVIDE ROOF SHEATHING EDGE CUPS CENTERED BETWEEN FRAMING AT <br />UNBLOCKED PLYWOOD EDGES. ALL FLOOR SHEATHING SHALL HAVE TONGUE AND GROOVE JOINTS OR BE <br />SUPPORTED BY SOLD BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF ROOF/FLOOR <br />SHEATHING. ROOF/FLOOR SHEATHING SHALL BE LAID FACE GRAIN PERPENDICULAR TO FRAMING MEMBERS. <br />MOISTURE CONTENT: WOOD MATERIAL USED FOR THIS PROJECT SHALL HAVE MAXIMUM MOISTURE CONTENT OF <br />19% EXCEPT FOR THE PRESSURE -TREATED WOOD SILL PLATE. <br />PRESERVATIVE TREATMENT: WOOD MATERIALS ARE REQUIRED TO BE 'TREATED WOOD" UNDER CERTAIN <br />CONDITIONS IN ACCORDANCE WITH IBC SEC 2304.11 "PROTECTION AGAINST DECAY AND TERMITES". CONFORM TO <br />ME APPROPRIATE STANDARDS OF THE AMERICAN WOOD -PRESERVERS ASSOCIATION (AMA) FOR SANK LUMBER, <br />GLUED LAMINATED TIMBER, ROUND POLES, WOOD PILES AND MARINE PILES. FOLLOW AMERICAN LUMBER <br />STANDARDS COMMITTEE (ALSC) QUALITY ASSURANCE PROCEDURES. PRODUCTS SHALL BEAR THE APPROPRIATE <br />MARK. <br />METAL CONNECTORS/PT WOOD: CK ENGINEERING LLC RECOMMENDS THAT ALL METAL HARDWARE AND FASTENERS <br />IN CONTACT WITH PRESSURE TREATED LUMBER BE STAINLESS STEEL TYPE 316L. AT THE OWNER'S RISK AND <br />DISCRETION, HOT -DIPPED GALVANIZED METAL HARDWARE AND FASTENERS MAY BE INVESTIGATED FOR USE IN LIEU <br />OF STAINLESS STEEL PROVIDED THAT THE FINISH HAS A MINIMUM ZINC CONTENT OF AT LEAST 1,85 OZ/SF AND <br />ITS USE IS COORDINATED BY THE CONTRACTOR AND WOOD SUPPLIER FOR THE EXPECTED ENVIRONMENT AND <br />MOISTURE EXPOSURE FOR APPROPRIATE USE BASED ON THE METHOD OF PRESERVATIVE TREATMENT OF THE <br />WOOD. <br />DETAILA <br />PIiIt1111111:1 <br />DETAIL C <br />MODEL <br />END STUD <br />CAPACITY(LBS) <br />ANCHORAGE TYPE I.,x.1 <br />FASTENERS <br />DOUG-FIR <br />HEM -FIR <br />#,,, <br />REQUIRED <br />C514 <br />FUR-TO-FUR <br />STRAP (El. <br />(30) 10d COMMON <br />2x STUD <br />2,490 <br />2,490 <br />LSTHDS/RJ <br />CAST -IN -PLACE <br />(16) 16d SINKERS <br />(2) 2x STUDST <br />1,975 <br />1,975 <br />STHD14/RJ <br />CAST -IN -PLACE <br />(22) 16d SINKERS <br />(2) 2x STUDS <br />3,695 <br />3,695 <br />HDU8 <br />SSTB28 <br />(20) '/4 0x21/4 <br />(3) 2, STUDS <br />7,870 <br />5,665 <br />SDS WOOD SCREWS <br />NOTES: <br />1. HOEDOWNS SPECIFIED ARE AS MANUFACTURED BY SIMPSON ANCHOR TIE DOWN CO., ING: ACCEPTABLE <br />EQUIVALENT PRODUCT SUBSTITUTIONS ARE AVAILABLE FROM OTHER MANUFACTURERS WITH SER APPROVAL. <br />2. LOCATE ALL HOEDOWNS AT ENDS OF ALL SHEAR WALLS & FASTEN TO BUNDLED END STUDS. <br />3. BUNDLED END STUDS SHOULD BE STITCH -NAILED TOGETHER USING MINIMUM (2) 16d 0 10"OC, LINO. <br />4. LOCATE "HDU#°, "LSTHD#" & "STHD#" HOEDOWNS AT CONCRETE FOUNDATION LEVEL (DETAIL B & C) <br />LOCATE "CS# 'MST", "MSTC#" & "CMST#" STRAPS AT FLOOR -TO -FLOOR CONNECTIONS. (DETAIL A) <br />5. ALL HOEDOWN ANCHOR BOLTS SHALL BE MIN 5" FROM CONCRETE WALL ENDS. <br />6. USE "SSTB" FOR 2x SILL PLATES & "SSTBL" FOR 3x SILL PLATES. <br />7. ADDITIONAL END STUD REQUIRED TO MEET MINIMUM 11/p" EDGE DISTANCE FROM CONCRETE CORNER TO "STHD" STRAP. <br />USE "RJ" STYLE WITH "STIED" WHERE RIM JOIST IS PRESENT. <br />8. INSTALL All HOEDOWN HARDWARE PER MANUFACTURER'S INSTRUCTIONS & RECOMMENDATIONS. <br />HOLDOWN SCHEDULE <br />SCALE: N.T.S. <br />WOOD -FRAMED SHEAR WALL SCHEDULE <br />FOR HEM-FIRIDOUI STUD FRAMING <br />BOTTOM PLATE & EDGE MEMBER <br />SILL PLATE REQUIREMENTS <br />SW <br />SW SHEATHING <br />NAIL SIZE & <br />RIM JOIST OR BLOCKING <br />REQUIREMENTS <br />SHEAR LOAD <br />SHEAR NAILING TO <br />8070M It <br />ANCHOR BOLT TO <br />SILL It AT <br />TYPE <br />APA-RATED <br />SPACING 0 PANEL EDGES <br />ATTACHMENT TO <br />TOP PLATE BELOW <br />CAPACITY (ELF) <br />WOOD FRAMING BELOW <br />AT FRAMING <br />CONCRETE FOUNDATION <br />FOUNDATION <br />1. 2 121 <br />N 5. 61 <br />18.91 <br />110111 <br />SW-6 <br />15/32" CD-EXT <br />0.131"e x 21/2" <br />CLIP 0 18"OC <br />0.148"e x 31/4" 0 6"OC <br />2x <br />6g <br />/.e 0 48"OC <br />P.T. 2x <br />260 <br />0 6"OC <br />SW-2 <br />15 32° CD-EXT <br />/ <br />0.131"e x 21/2" <br />CLIP 0 COG <br />0.148"e x 31/4" 0 4"OC <br />3x <br />5 /g"0 0 24"OC <br />P.T. 3x <br />640 <br />0 2"OC, STAGGERED <br />& CLIP 0 16"OC <br />Is <br />Is <br />NOTES <br />1. INSTALL PANELS EITHER HORIZONTALLY OR VERTICALLY <br />2. WHERE SHEATHING IS APPUED ON BOTH SIDES OF WALL, PANEL EDGE JOINTS ON 2x FRAMING <br />SHALL BE STAGGERED SO THAT JOINTS ON OPPOSITE SIDES ARE NOT LOCATED ON THE SAME <br />STUDS. <br />3. BLOCKING IS REQUIRED AT ALL PANEL EDGES. <br />4. PROVIDE SHEAR WALL SHEATHING AND NAILING FOR ENTIRE LENGTH OF THE WALLS INDICATED ON <br />THE PLANS. ENDS OF FULL HEIGHT WALLS ARE DESIGNATED BY WINDOWS, OR DOORWAYS OR AS <br />DESIGNATED ON PUNS. HOEDOWN REQUIREMENTS PER PLANS. <br />5. SHEAR WALLS DESIGNATED AS PERFORATED SHEAR WALLS REQUIRE SHEATHING, SHEAR WALL NAILING, <br />ETC. ABOVE AND BELOW ALL OPENINGS). <br />6. SHEATHING EDGE NAILING IS REQUIRED AT ALL HOEDOWN POSTS. EDGE NAILING MAY ALSO BE <br />REQUIRED TO EACH STUD USED IN BUILT-UP HOEDOWN POSTS. ADDITIONAL INFORMATION PER <br />HOEDOWN SCHEDULE & DETAILS. <br />7. INTERMEDIATE FRAMING TO BE 2x MINIMUM MEMBERS. ATTACH SHEATHING TO INTERMEDIATE FRAMING <br />WITH 0.148"0 x 21/2" NAILS AT 12.00 WHERE STUDS ARE SPACED AT 16.00 AND 0.148"0 x 21/2" <br />NAILS AT COG WHERE STUDS ARE SPACED AT 2410C. <br />S. BASED ON OU31"0 x 11/q" NAILS USED TO ATTACH FRAMING CUPS DIRECTLY TO FRAMING. USE <br />0.13110 x 21/2" NAILS WHERE INSTALLED OVER SHEATHING. <br />9. FRAMING CLIPS: SIMPSON 'A35" OR 175" OR APPROVED EQUIVALENT. <br />WOOD -FRAMED SHEAR WALL SCHEDULE <br />SCALE N.T.S <br />10. ANCHOR BOLTS SHALL BE PROVIDED WITH HOT -DIPPED GALVANIZED STEEL PLATE WASHERS <br />3"x3"xO.229"(MIN). THE HOLE IN THE PLATE WASHER MAY BE DIAGONALLY SLOTTED 13/I6:13/p <br />PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND NUT. PLATE <br />WASHER TO EXTEND TO WITHIN I/y" OF THE EDGE OF THE SILL PLATE ON THE SIDES) WITH <br />SHEATHING. WHERE SHEAR WALLS ARE SHEATHED ON BOTH SIDES OF 2x6 WALL FRAMING, USE <br />45"x4.5"xO.229"(MIN) PLATE WASHERS. EMBED ANCHOR BOLTS 7" MINIMUM INTO THE CONCRETE. <br />11. PRESSURE TREATED MATERIAL CAN CAUSE EXCESSIVE CORROSION IN THE FASTENERS. PROVIDE <br />HOT -DIPPED GALVANIZED (ELECTRO-PLATING IS NOT ACCEPTABLE) NAILS AND CONNECTOR PLATES <br />(FRAMING ANGLES, ETC.) FOR ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED FRAMING <br />MEMBERS. ADDITIONAL INFORMATION PER STRUCTURAL NOTES. <br />12. WHERE WOOD SHEATHING IS APPLIED OVER GYPSUM SHEATHING, CONTACT THE ENGINEER OF RECORD <br />FOR ALTERNATE NAILING REQUIREMENTS. <br />13. AT ADJOINING PANEL EDGES, (2) 2x STUDS NAILED TOGETHER MAY BE USED IN PUCE OF SINGLE 3x <br />STUD. DOUBLE 2X STUDS SHALL BE CONNECTED TOGETHER BY NAIUNG THE STUDS TOGETHER WITH <br />3' LONG NAILS OF THE SAME SPACING AND DIAMETER AS THE PLATE NAILING. <br />14, CONTACT THE STRUCTURAL ENGINEER OF RECORD FOR ADHESIVE OR EXPANSION BOLT ALTERNATIVES <br />TO CAST -IN -PLACE ANCHOR BOLTS. SPECIAL INSPECTION MAY BE REQUIRED. <br />15. NAIL STUDS TO 3x BOT7OM/SILL PLATES WITH EITHER (2) 0.148'Ox4" END NAILS OR <br />(4) 0.13170x21/2" TOENAILS. <br />cV�bV� N* gB�`b' <br />ca <br />o s�t04z15 G� <br />�`t'ONA4 <br />12/16/2020 <br />LU <br />CD <br />NQ <br />I L <br />Q <br />00 <br />P <br />Q <br />0a <br />z3 <br />/vF'� <br />CN <br />� <br />Q/V <br />aQui <br />w <br />O <br />a <br />U <br />w <br />0 <br />w <br />0 <br />a <br />0 <br />h <br />w <br />Drawn By: PK <br />Checked By: SC <br />Date: 12-16-2020 <br />CK JOB NO. <br />20-044 <br />STRUCTURAL <br />NOTES//SCHED. <br />S-1.0 <br />