My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1525 FLORIDA DR 2024-02-26
>
Address Records
>
FLORIDA DR
>
1525
>
1525 FLORIDA DR 2024-02-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 12:03:58 PM
Creation date
2/27/2023 1:57:07 PM
Metadata
Fields
Template:
Address Document
Street Name
FLORIDA DR
Street Number
1525
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENPHASE <br />IQ8 and IQ8+ Microinverters <br />Our newest I08 Microinverters are the industry's first microgrid-forming, software - <br />defined microinverters with split -phase power conversion capability to convert DC <br />power to AC power efficiently. The brain of the semiconductor -based microinverter <br />is our proprietary application -specific integrated circuit (ASIC) which enables the <br />microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced <br />55nm technology with high speed digital logic and has super -fast response times <br />to changing loads and grid events, alleviating constraints on battery sizing for home <br />energy systems. <br />Part of the Enphase Energy System. I08 Series <br />Microinverters integrate with the Enphase IQ <br />Battery, Enphase 10 Gateway, and the Enphase <br />App monitoring and analysis software. <br />emc <br />Connect PV modules quickly and easily to <br />108 Series Microinverters using the included <br />O-DCC-2 adapter cable with plug-n-play MC4 <br />connectors. <br />I08 Series Microinverters redefine reliability <br />standards with more than one million <br />cumulative hours of power -on testing, <br />enabling an industry -leading limited warranty <br />of up to 25 years. <br />IQ8 Series Microinverters are UL Listed as <br />PV Rapid Shut Down Equipment and conform <br />with various regulations, when installed <br />according to manufacturer's instructions. <br />0 2021Enphase Energy. All rights reserved. Enphase. the Enphase logo. I08 microinverters. <br />and other names are trademarks of Enphase Energy. Inc. Data subject to change. <br />108SP-DS-0002- Of-EN-US-2021-10-19 <br />Easy to install <br />Lightweight and compact with <br />plug-n-play connectors <br />Power Line Communication <br />(PLC) between components <br />Faster installation with simple <br />two -wire cabling <br />High productivity and reliability <br />Produce power even when the <br />grid is down <br />More than one million cumulative <br />hours of testing <br />Class II double -insulated <br />enclosure <br />Optimized for the latest high- <br />powered PV modules <br />Microgrid-forming <br />Complies with the latest <br />advanced grid support <br />Remote automatic updates for <br />the latest grid requirements <br />Configurable to support a wide <br />range of grid profiles <br />Meets CA Rule 21(UL 1741-SA) <br />requirements <br />IQ8 and IQ8+ Microinverters <br />Commonly used module pairings' <br />w <br />235 - 350 <br />235 - 440 <br />Module compatibility <br />60-cell/120 half -cell 60-cell/120 half <br />-cell and 72-cell/144 half -cell <br />MPPT voltage range <br />v <br />27 - 37 <br />29 - 45 <br />Operating range <br />V <br />25 - 48 <br />25 - 58 <br />Min/max start voltage <br />v <br />30 / 48 <br />30 / 58 <br />Max input DC voltage <br />v <br />50 <br />60 <br />Max DC current° [module $so] <br />A <br />15 <br />Overvoltage class DC port <br />II <br />DC port backfeed current <br />mA <br />0 <br />PV array configuration <br />Ixt Ungrounded array: No additional DC side protection required: AC side protection requires max 20A per branch circuit <br />OUTPUT r <br />Peak output power <br />VA <br />245 <br />300 <br />Max continuous output power <br />VA <br />240 <br />290 <br />Nominal (L-L) voltage/range' <br />v <br />240 / 211 - 264 <br />Max continuous output current <br />A <br />1.0 <br />1.21 <br />Nominal frequency <br />He <br />60 <br />Extended frequency range <br />Hz <br />50 - 68 <br />Max units per 20 A (L-L) branch circuit' <br />16 <br />13 <br />Total harmonic distortion <br /><5% <br />Overvoltage class AC port <br />III <br />AC port backfeed current <br />mA <br />30 <br />Power factor setting <br />1.0 <br />Grid -tied power factor (adjustable) <br />0.85leading - 0.85 tagging <br />Peak efficiency <br />% <br />97.5 <br />97.6 <br />CEC weighted efficiency <br />% <br />97 <br />97 <br />Night-time power consumption <br />mw <br />60 <br />MECHANICAL DATA <br />Ambient temperature range <br />-40°C to+60°C (-401F to.140°F) <br />Relative humidity range <br />4% to 100% (condensing) <br />DC Connector type <br />MC4 <br />Dimensions (HxWxD) <br />212 mm (8.31 x 175 mm (6.9") x 30.2 mm 0.21 <br />Weight <br />1.08 kg (2.38lbs) <br />Cooling <br />Natural convection - no fans <br />Approved for wet locations <br />yes <br />Acoustic noise at 1 in <br /><60 d8A <br />Pollution degree <br />PD3 <br />Enclosure <br />Class II <br />double -Insulated. corrosion resistant polymeric enclosure <br />Environ. category / UV exposure rating <br />NEMA Type 6 / outdoor <br />CA Rule 21(UL 1741-SA). UL 62109-1. ULI741/IEEE1547, FCC Part 15 Class B.ICES-0003 Class B. CAN/CSA-C22.2 NO.107.1-01 <br />Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014. NEC 2017, and NEC 2020 section <br />690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems. for AC and DC conductors, when installed according to <br />manufacturer's instructions. <br />(1) No enforced DC/AC ratio. See the compatibility calculator at https://Ilnk.enphase.com/ <br />module -compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage <br />range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to <br />local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2021-10-19 <br />Lumio <br />SMART ENERGY TODAY <br />(SET) <br />1550 DIGITAL DR, LEHI, UT <br />84043, USA <br />SYSTEM INFO <br />(16) O CELLS <br />Q.PEAK DUO BLK ML-G10+ <br />(400W ) <br />(16) ENPHASE <br />IQ8PLUS-72-2-US (240V) <br />DC SYSTEM SIZE: 6.400 kWDC <br />AC SYSTEM SIZE: 4.800 kWAC <br />REVISIONS <br />DESCRIPTION I DATE IREV <br />PROJECT NAME & ADDRESS <br />Q <br />W <br />Z) <br />M <br />O <br />N <br />00 <br />t) <br />W <br />J <br />LLJ <br />W <br />U w <br />Z <br />2 <br />Q <br />0 ry <br />W <br />— <br />W <br />W <br />� <br />U <br />� <br />W <br />Q <br />N <br />p <br />O <br />J <br />U- <br />Lf) <br />N <br />DATE: 12/6/2022 <br />SHEET NAME <br />EQUIPMENT <br />SPECIFICATIONS <br />SHEET SIZE <br />ANSI B <br />11tt X 17" <br />SHEET NUMBER <br />PV-13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.