Laserfiche WebLink
Lumio <br />SMART ENERGY TODAY <br />(SET) <br />1550 DIGITAL DR, LEHI, UT <br />84043, USA <br />SYSTEM INFO <br />(16) 0 CELLS <br />Q.PEAK DUO BLK ML-G10+ <br />(400W ) <br />(16) ENPHASE <br />IQ8PLUS-72-2-US (240V) <br />DC SYSTEM SIZE: 6.400 kWDC <br />SM■■ SOLAR APPENDIX C : ■ "�SM SOLAR CODE COMPLIANCE NOTES : �, AC SYSTEM SIZE: 4.800 kWAC <br />MOUNT UNIVERSALM ENDCLAMP INSTALLATION GUIDE PAGE ' MOUNT INSTALLATION GUIDE ; PAGE <br />1+P MIN <br />1. Position clamp to align T-bolt with rail 2. Rotate clamp clockwise 2/3 of a turn 3. Place module at least 3/4' from end of 4. While applying pressure to hold the <br />slot. Lower clamp and Insert T-bolt into to engage T-bolt inside fail slot, rail and position clamp against module clamp against the module, push down on <br />fait slot. frame, the module side of the clamp cap. <br />50 mm 31 & 17 mm 33 emr <br />(Res <br />"mm 40 mm 46mm <br />5. When the cap contacts the module 6.Tighten bolt and torque to 15 ft-lbs, 7, Confirm clamp is engaged in correct module height position and that the top of the <br />frame, release and it will re-engage to cap is sitting level with the module frame. <br />the clamp base. <br />NOTE: When installing 46mm modules, loosen bolt by 1 turn before positioning clamp <br />against module frame. Do not Force clamp onto module frame as this may damage the <br />bonding pin. <br />--------------------------------------------------------------------------------------------------------------------------------------------- <br />SYSTEM LEVEL RRE CLASSIFICATION <br />The system fire class rating requires installation in the manner specified in the SOLARMOUNT Installation Guide. SOLARMOUNT has been classified to the system <br />level fire portion of UL2703. SOLARMOUNT has achieved system level performance for steep sloped roofs. The fire classification rating is only valid on roof pitches <br />greater than 2:12 (slopes i; 2 inches per foot, or 9.5 degrees). The system is to be mounted over fire resistant roof covering rated for the application. There is no <br />required minimum or maximum height limitation above the roof deck to maintain the system fire rating for SOLARMOUNT. Module Types, System Level Fire Ratings, <br />and Mitigation Requirements are listed below: <br />RaRType <br />Module Fire Types I System l eel Fire Rallrq Rail Di on <br />Module <br />Midyatlon <br />Orientation <br />Required <br />Standard & HD Rails <br />1, 2, 3 with Metal Frame, 10 with Metal Class A. Class B & Class C , East-West <br />Landscape OR Portrait <br />None Required <br />Frame, 19,22.25.29. & 3o i Norm -South <br />Landscape OR Portrait <br />Hone Required <br />Light Rail 1 & 2 CWzs A, Class 8 & Class C I East-West Landscape OR Portrait None Required <br />North -South Landscape OR Portrait None Required <br />Standard, Ugh4 & 4 & S Class A. Class B & Class C East-West Landscape OR Portrait Trim Installation per solar <br />HD Rails I North -South Landscape OR Portrait Mount tnetatUtIon Gulde <br />his racking V05tem rn;�f ne users to ground ari mourn a fr/ woo ulc •-c;ilyiynml UL1703 or UL61730 Dory wizen - he $petlfic module has reen <br />gr 51 111)g unry.c, mci,wlwq iI, r„I,iVuantr wilco Inv InCt1~1 instructions. <br />UL2703 CERTIFICATION MARKING LABEL UNIRAC <br />Unirac SOLARMOUNT is listed to UL 2703. Certification marking is embossed on all mid clamps as shown. labels with <br />additional information will be provided . After the racking system is fully assembled, a single Label should be applied to the a <br />SOLARMOUNT rail at the edge of the array. Before applying the label, the comers of the Label that do not pertain to the <br />system being installed must be removed so that only the installed system type is showing. C US <br />Nute: i he s1(--es label suQuld D4 piaced suclr :ha: a is vitik:W, uut not uulwata Ca 266909 <br />SM STANDARD RAIL��'— '! <br />SM UGHT RAIL <br />REVISIONS <br />DESCRIPTION I DATE IREV <br />PROJECT NAME & ADDRESS <br />Q <br />U) <br />Z) <br />Cl <br />O <br />N <br />00 <br />O <br />W <br />J <br />LLJ <br />W <br />U w <br />Z <br />= <br />Q <br />0 W <br />W W <br />� <br />U <br />� <br />W <br />Q <br />N <br />p <br />Fy <br />O <br />J <br />LL <br />L!i <br />N <br />L1') <br />DATE: 12/6/2022 <br />SHEET NAME <br />EQUIPMENT <br />SPECIFICATIONS <br />SHEET SIZE <br />ANSI B <br />11tt X 17" <br />SHEET NUMBER <br />PV-18 <br />