My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
401 PECKS DR 2025-04-18
>
Address Records
>
PECKS DR
>
401
>
401 PECKS DR 2025-04-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2025 1:58:05 PM
Creation date
3/16/2023 2:29:14 PM
Metadata
Fields
Template:
Address Document
Street Name
PECKS DR
Street Number
401
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Enphase IQ 7 and IQ 7+ Microinverters <br />INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US <br />Commonly used module pairings' <br />Module compatibility <br />Maximum input DC voltage <br />Peak power tracking voltage <br />Operating range <br />Min/Max start voltage <br />Max DC short circuit current (module Isc) <br />Overvoltage class DC port <br />DC port backfeed current <br />235 W - 350 W + <br />60-cell PV modules only <br />48 V <br />27V-37V <br />16V-48V <br />22V/48V <br />15A <br />0A <br />235 W - 440 W + <br />60-cell and 72-cell PV modules <br />60 V <br />27V-45V <br />16V-60V <br />22V/60V <br />15A <br />0A <br />PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; <br />AC side protection requires max 20A per branch circuit <br />OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter <br />Peak output power <br />250 VA <br />295 VA <br />Maximum continuous output power <br />240 VA <br />290 VA <br />Nominal (L-L) voltage/range2 <br />240 V / <br />208 V / <br />240 V / <br />208 V / <br />211-264 V <br />183-229 V <br />211-264 V <br />183-229 V <br />Maximum continuous output current <br />1.0 A (240 V) <br />1.15 A (208 V) <br />1.21 A (240 V) <br />1.39 A (208 V) <br />Nominal frequency <br />60 Hz <br />60 Hz <br />Extended frequency range <br />47 - 68 Hz <br />47 - 68 Hz <br />AC short circuit fault current over 3 cycles <br />5.8 Arms <br />5.8 Arms <br />Maximum units per 20 A (L-L) branch circuit3 <br />16 (240 VAC) <br />13 (208 VAC) <br />13 (240 VAC) <br />11 (208 VAC) <br />Overvoltage class AC port <br />III <br />III <br />AC port backfeed current <br />0 A <br />0 A <br />Power factor setting <br />1.0 <br />1.0 <br />Power factor (adjustable) <br />0.7 leading ... <br />0.7 lagging <br />0.7 leading ... <br />0.7 lagging <br />EFFICIENCY <br />@240 V <br />@208 V <br />@240 V <br />@208 V <br />Peak CEC efficiency <br />97.6 % <br />97.6 % <br />97.5 % <br />97.3 % <br />CEC weighted efficiency <br />97.0 % <br />97.0 % <br />97.0 % <br />97.0 % <br />MECHANICAL DATA <br />Ambient temperature range <br />Relative humidity range <br />Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) <br />Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) <br />Dimensions (WxHxD) <br />Weight <br />Cooling <br />Approved for wet locations <br />Pollution degree <br />Enclosure <br />-400C to +65°C <br />4% to 100% (condensing) <br />MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) <br />Friends PV2 (MC4 intermateable). <br />Adaptors for modules with MC4 or UTX connectors: <br />PV2 to MC4: order ECA-S20-S22 <br />PV2 to UTX: order ECA-S20-S25 <br />212 mm x 175 mm x 30.2 mm (without bracket) <br />1.08 kg (2.38 Ibs) <br />Natural convection - No fans <br />Yes <br />PD3 <br />Class II double -insulated, corrosion resistant polymeric enclosure <br />Environmental category / UV exposure rating NEMA Type 6 / outdoor <br />FEATURES <br />Communication <br />Power Line Communication (PLC) <br />Monitoring <br />Enlighten Manager and MyEnlighten monitoring options. <br />Both options require installation of an Enphase IQ Envoy. <br />Disconnecting means <br />The AC and DC connectors have been evaluated and approved by UL for use as the load -break <br />disconnect required by NEC 690. <br />Compliance <br />CA Rule 21 (UL 1741-SA) <br />UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, <br />CAN/CSA-C22.2 NO. 107.1-01 <br />This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and <br />NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC <br />and DC conductors, when installed according manufacturer's instructions. <br />1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. <br />2. Nominal voltage range can be extended beyond nominal if required by the utility. <br />3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. <br />To learn more about Enphase offerings, visit enphase.com u E N P H AS E. <br />© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. <br />2018-05-24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.