My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1203 SE EVERETT MALL WAY BASE FILE 2023-05-15
>
Address Records
>
SE EVERETT MALL WAY
>
1203
>
BASE FILE
>
1203 SE EVERETT MALL WAY BASE FILE 2023-05-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2023 8:21:36 AM
Creation date
3/16/2023 2:51:58 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1203
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lateral Analysis: CARRIER 48FCDA04A2A5, Weight = 482 # <br />(Between Unit & Spring Isolator) <br />Seismic Design: <br />FP = {(0.4 aP Sos )x(1 + 2z/h)xWp}/(Rp/lp) = 0.54 WP <br />FP MAX = 1.6 Sos Ip Wp = 1.74 Wp (Equation 13.3-2) <br />FP MIN - 0.3 SpS I Wp = 0.33 Wp (Equation 13.3-3) <br />Horizontal Force: <br />FP = QE = 0.54 W = 270 lbs. <br />Vertical Force: <br />E„ = (±) 0.2 SDS W = 108 lbs. <br />From ASCE 7-16 Table 13.6-1: aP = 2.5 RP = 6.0 <br />p = 1.0 <br />IP= 1.0 per ASCE 7-16 Section 13.1.3 Wp = 500.0 <br />lbs. <br />Mean Roof Height (h): 16.5 ft. Comp. Attachment Height (z): 16.5 ft. <br />Ground Motion: SMs = Fa*SS = 1.627 SpS = (2/3)*SMS = 1.085 <br />ASCE7-16, 2.4.5 8. 1.013 + 0.7E„ + 0.7Eh from Eh = pQE= 270 lbs. <br />9. 1.OD + 0.525E„ + 0.525Eh + 0.75L + 0.75S <br />10. 0.61D - 0.7E„ + 0.7Eh <br />Mech Unit: W = 46.625 in. L = 74.375 in. (L>W) <br />H = 33.250 in. C.G. = 18.000 in. Center of Gravity <br />Weight = 500.00 lbs.( Unit Weight + Misc) <br />0.7 Eh = 189 lbs. <br />Check Overturning (ASD) : <br />T, = C, = 0.7 [Eh* (C.G.) + (E /2)]/ 40.5" = 85 lbs.---> No Uplift <br />T2 = C2 = 0.7 [Eh* (C.G.) + (E /2)]/ 68.5" = 50 lbs.---> No Uplift <br />EQ 8 & 9: 1.OD = 1.0 (Wp/2) = 250 lbs. <br />' <br />EQ 10: 0.613 = 0.6 (Wp/2) = 150 lbs. <br />(ASCE 7-16 Section 2.4.5 Basic Combination with Seismic Load Effects 8.9.10. <br />'B', <br /><! <br />Wind Design: Exposure 110 mph, 25 ft (Max. Height) <br />qZ = 0.00256(KZ)(K,)(Kd)(Ke) V2 = 20.44 psf > 16 psf. : Eq. 26.10-1 <br />KZ = 0.66 : Velocity presure exposure coefficient per ASCE 7-16 Table 26.10-1tjat <br />Kn = 1.00 : Topographic factor per ASCE 7-16 Section 26.8.2 <br />Kd = 0.85 : Wind directionality factor, per ASCE 7-16 Table 26.6-1 (roof top equipment) <br />Ke = 1.00 : Ground elevation factor, per ASCE 7-16 Section 26.9. <br />V = 110.00 : Basic wind speeds (Risk Category II) per ASCE 7-16 Figure 26.5-1 B <br />Fh = qZ (GCr) Af: (Horiz: GCr = 1.9) : Eq.29.4-2 & F = qZ (GCr) Ar : (Vertical Uplift: GCr = 1.5) : Eq. 29.4-3 <br />ASCE7-16, 2.4.1 5. 1.01) + 0.6W <br />6. 1.01) + 0.75L + 0.75(0.6W) + 0.75 (Lr or S or R) <br />7. 0.61)+0.6W �`�` <br />Check Overturning (ASD) : �E� <br />(ASD) : Fh, = 0.6x(Fh) (WxH) = 51 lbs. <br />T, = C, = 0.6x(F )x[W*HZ/2] / 68.5" = 4 lbs.---> No Uplift <br />(ASD) : Fh2 = 0.6x(Fh) (LxH) = 40 <br />T2 = C2 = 0.6x(F )x[L*HZ/2] / 40.5" = 130 lbs.---> No Uplift <br />EQ 5 & 6: 1.01) = 1.0 (Wp/2) = 250 lbs. <br />EQ 7: 0.61D = 0.6 (Wp/2) = 150 lbs. <br />(ASCE 7-16 Section 2.4.1 Basic Combination with Wind Load Effects 5.6.7.) <br />T-71- 6+ 4 Jt3 <br />CXT- <br />