VIBRATION ISOLATION / SEISMIC SCHEDULE LAST UPDATED: 0415 21 <br />UNIT <br />TAG <br />SERVES <br />BASIS OF <br />DESIGN 1 <br />DEFL <br />INCH <br />BASE <br />TYPE <br />SEISMIC <br />RESTRAINT <br />REMARKS <br />NA <br />ROOFTOP UNITS LARGE RAISED CURB <br />WELD TO CURB <br />2 4 10 14 <br />NA <br />ROOFTOP UNITS SMALL MFG CURB <br />SCREW TO CURB <br />2 4 10 <br />NA <br />ROOFTOP UNITS SENSITIVE AREAS RAISED CURB <br />1 2 OR 4 <br />WELD TO CURB <br />2 4 30 14 <br />NA <br />FLOOR MOUNTED AIR HANDLING UNITS <br />KNC RSP <br />0.125 <br />LAG BOLT / WEDGE ANCHOR <br />4 10 12 14 <br />NA <br />STRUCTURE HUNG HYDRONIC HEAT PUMPS <br />KNC SH <br />1 <br />CABLE RESTRAINT <br />5 10 15 <br />NA <br />WALL MOUNTED HEAT PUMPS <br />4,10 <br />NA <br />CHILLERS <br />KNC FLSS <br />0.25 1 2 or 4 <br />SFB <br />WEDGE ANCHOR <br />2 3 10 14 15 <br />NA <br />CURB MOUNTED COOLING TOWERS <br />KNC FLSS <br />1 2 or 4 <br />SFB <br />WELD TO CURB & WEDGE ANCHOR / WELD TO STRUCTURE <br />2,3 10,14,15 <br />NA <br />BOILERS <br />KNC RSP <br />0.125 <br />WEDGE ANCHOR <br />10 12 14 <br />NA <br />BASE MOUNTED PUMPS <br />KNC FHS <br />1 2 or 4 <br />CIB <br />WEDGE ANCHOR <br />8 10 14 15 <br />NA <br />VAV TERMINALS FAN POWERED <br />KNC SH <br />1 <br />CABLE RESTRAINT <br />6 10 15 <br />NA <br />UTILITY SET EXHAUST FANS <br />KNC FHS <br />1 2 or 4 <br />WEDGE ANCHOR <br />8 10 15 <br />NA <br />CURB MOUNTED EXHAUST FANS <br />4 10 <br />NA <br />FLOOR MOUNTED GARAGE EXHAUST FANS <br />10,11 <br />NA <br />SUSPENDED SUPPLY EXHAUST FANS <br />KNC SH <br />1 2or4 <br />- <br />CABLE RESTRAINT <br />10 13 15 <br />NA <br />LIFE SAFETY PRESSURIZATION FANS <br />LAG BOLT WEDGE ANCHOR <br />10,16 <br />NA <br />CHILLED HYDRONIC OR CONDENSER WATER PIPE <br />KNC SH <br />1 <br />CABLE RESTRAINT <br />5 8 9 15 <br />NA <br />NATURAL GAS PIPING <br />CABLE RESTRAINT <br />16 <br />NA <br />DUCTWORK <br />CABLE RESTRAINT <br />5 8 15 <br />GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS <br />PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION &INSTALL PER MANUFACTURERS REQUIREMENTS <br />NOTE: CTB = COOLING TOWER BASE, CIB = CONCRETE INERTIA BASE <br />1 OR EQUAL ISOLATION (ISAT, MASON, VIBRACOUSTICS OR AS APPROVED), CONFIRM INSTALL METHOD WITH FIELD PRIOR TO ORDER <br />2 SEISMIC RATED CURB / ISOLATOR <br />3 USE HEIGHT SAVING BRACKETS FOR SPRING ISOLATORS <br />4 INTERNAL ISOLATION PROVIDED INTEGRAL WITH UNIT <br />5 PROVIDE FLEXIBLE HOSES FOR PIPING CONNECTIONS AT UNIT <br />6 WHERE DESIGNATED AS REQUIRED BY DESIGN ENGINEER BASED ON UNIT MOUNTING LOCATION IN ACOUSTICALLY/VIBRATIONALLY SENSATIVE AREAS <br />7 LAG BOLT (WOOD) OR WEDGE ANCHOR (CONCRETE) TO CONCRETE PAD WITH NEOPRENE GROMMET IF NON -SEISMIC RATED ISOLATOR USED <br />8 CONFIRM EQUIPMENT RPM, REFER TO "REQUIRED DEFLECTION BASED ON RPM" SPREADSHEET TO DETEREMINE PROPER DEFLECTION <br />9 THREE SPRING HANGERS FROM ROTATING EQUIPMENT CONNECTIONS <br />10 SEISMIC RESTRAINT AS REQUIRED BY CODE AND/OR LOCAL AUTHORITY HAVING JURISDICTION OR PER SMACNA GUIDELINES <br />* SUSPENDED EQUIP WITH IP=1.0 AND >20LBS REQUIRES SEISMIC BRACING - IF THE COMPONENT/EQUIPMENT IS RIGIDLY ATTACHED TO THE DUCT AND THE DUCT IS BRACED, THEN NO ADDITIONAL <br />SEISMIC IS REQ'D. COMPONENTS/EQUIP >75LBS REQUIRE INDEPENDENT VERTICAL SUPPORTS AND SEISMIC BRACING. EQUIP WITH IP=1.5 AND <20LBS AND FLEXIBLY CONNECTED MAY BE OMITTED <br />11 FLOOR STAND PROVIDED BY MECHANICAL CONTRACTOR <br />12 4" MINIMUM (CONFIRM WITH STRUCTURAL ENGINEER BASED ON EQUIPMENT WEIGHT AND EMBED ANCHOR DEPTH REQ'D) CONCRETE HOUSEKEEPING PAD INSTALLED UNDER UNIT BY GC <br />13 FOR UNITS THAT ARE GREATER THAN 2 HP IN SIZE <br />14 PROVIDE 1.SX'S UNIT WEIGHT IN CONCRETE BELOW UNIT AND MAXIMUM OF 1/8" DEFLECTION ACROSS LENGTH OF UNIT BY GC <br />15 DEFLECTION AS REQUIRED PER ASHRAE APPLICATIONS, CHAPTER 48 BASED ON STRUCTURE ITEM WILL BE SUPPORTED FROM (VERIFY PRIOR TO ORDER) <br />16 COMPONENT IMPORTANCE FACTOR (Ip = 1.5) <br />MINIMUM DUCT INSULATION LAST UPDATED 05/03/21 <br />INSULATION <br />DUCT SYSTEM <br />DUCT LOCATION AND USE <br />R-VALUE <br />REMARKS <br />CLIMATE ZONE 4C <br />SUPPLY AIR OR <br />OUTSIDE THE BUIDING (OUTDOORS AND EXPOSED TO WEATHER) <br />R-8 <br />1 <br />RETURN AIR <br />SUPPLY AIR OR <br />UNCONDITIONED SPACE (ENCLOSED BUT NOT IN THE BUILDING CONDITIONED <br />R-6 <br />1 <br />RETURN AIR <br />ENVELOPE <br />SUPPLY AIR OR <br />UNCONDITIONED SPACE (DUCT CONVEYS AIR THAT IS WITHIN 15-F OF THE AIR <br />RETURN AIR <br />TEMPERATURE OF THE SURROUNDING UNCONDITIONED SPACE) <br />R-3.3 <br />2 <br />SUPPLY AIR OR <br />IN A BUILDING ENVELOPE ASSEMBLY <br />R-16 <br />3 <br />RETURN AIR <br />WITHIN CONDITIONED SPACE (SUPPLY DUCT CONVEYS AIR THAT IS LESS THAN 55-F <br />R-3.3 <br />1 <br />SUPPLY AIR <br />OR GREATER THAN 105'F <br />SUPPLY AIR <br />WITHIN CONDITIONED SPACE THAT THE DUCT DIRECTLY SERVES SUPPLY DUCT <br />NONE <br />1 <br />WITHIN CONDITIONED SPACE (SUPPLY DUCT OONVEYS AIR THAT IS 55-F OR <br />SUPPLY AIR <br />GREATER AND 105'F OR LESS <br />NONE <br />- <br />RETURN OR <br />WITHIN CONDITIONED SPACE, DOWNSTREAM OF AN ENERGY RECOVERY MEDIA, <br />R-8 <br />_ <br />EXHAUST AIR <br />UPSTREAM OF AN AUTOMATIC SHUT OFF DAMPER <br />RELIEF OR <br />WITHIN CONDITIONED SPACE AND DOWNSTREAM OF AN AUTOMATIC SHUT OFF <br />R-16 <br />- <br />EXHAUST AIR <br />DAMPER <br />OUTSIDE AIR <br />INSIDE ODNDITIONED SPACE AND UPSTREAM OF AN AUTOMATIC <br />2800 CFM <br />R-16 <br />4 <br />SHUT OFF DAMPER <br />OUTSIDE AIR <br />INSIDE CONDITIONED SPACE AND DOWNSTREAM OF AN AUTOMATIC <br />z2800 CFM <br />R-8 <br />SHUT OFF DAMPER TO HVAC UNIT OR ROOM <br />OUTSIDE AIR <br />INSIDE CONDITIONED SPACE <br /><28M CFM <br />R-7 <br />5 <br />NOTES: <br />1 SEE ENERGY CODE SECTION C403.10.1.2 FOR DETAILS <br />2 SEE IMC SECTION 603.12 FOR ADDITIONAL REQUIREMENTS FOR CONDENSATION CONTROL AT DUCTWORK <br />3 DUCT OR PLENUM IS SEPARATED FROM BUILDING ENVELOPE ASSEMBLY WITH THE MINIMUM INSULATION VALUE <br />4 SEE ENERGY CODE SECTION C403.10.1.1 FOR ADDITIONAL REQUIREMENTS <br />5 SEE EXCEPTION 1 TO SECTION C403.10.1.1 FOR ADDITIONAL DETAILS <br />STANDARD INSERT METHODS <br />NEW A D EXISTING CONDITIO <br />DUCT CONSTRUCTION STANDARDSDUCTWORK HANGER REQUIREMENTS <br />ROUND, OVAL AND RECTANGULAR <br />RECTANGULAR DUCT <br />Iw.D TO" A w 6a"1 <br />RECTANGULAR DUCT <br />I W+D 100^ Awl 60"I <br />SUPPORTS REQUIRED <br />• NO2 GABLE: STUD (PLAT) <br />RREL(PANI <br />SUPPORTS REQUIRED <br />• NO3 CABLE: STUD (PLAT) <br />03 CABLE, BARREL(PAN) <br />BEARER REQUIRED <br />BEARER REQUIRED <br />• GBIPPLE TRAPEZE BRACKET <br />• CRIPPLE TRAPEZE BRACKET <br />i <br />OVAL DUCT <br />IW+D <TO"8w <br />OVAL DUCT <br />WIDTH 5so"I <br />SUPPORTS REQUIRED <br />SUPPORTS REQUIRED <br />• NO2 CABLE: STUD (FLAT) <br />NO3 CABLE: STUD (FLAT) <br />BARREL (PAN) <br />LL(111) <br />BEARER REQUIRED <br />P1000: 1.5- UNI-RUTTR <br />BEARERI!EQUIRED <br />UT <br />HANGER SPACING GUIDE <br />INSTALL HANGERS SHOWN ON... <br />ROUND @ 1 EVERY 10 FEET <br />OVAL 0 1 EVERY 08 FEET <br />RECT V 1 EVERY 08 FEET <br />RECTANGULAR DUCT <br />I_ < B6" A WIDTH 5 IS-) <br />SUPPORTS REQUIRED <br />• LS GALV THREADED ROD <br />BEARER REQUIRED <br />OVAL DUCT <br />Iw+D 5 98" a WIDTH < TS-) <br />SUPPORTS REQUIRED_ <br />•e GALV THREADED ROD <br />BEARER REQUIRED <br />oo: 1-SIB' UNIiTRUT <br />RECTANGULAR DUCT <br />WIDTHSUPPORTS REQUIRED <br />• LB GALV THREADED ROD <br />BEARER REQUIRED <br />P1001: 1-518 DOUBLE STRUT <br />II ll <br />OVAL DUCT <br />SUPPORTS REQUIRED <br />• 3e GALV THREADED AOD <br />BEARER REQUIRED <br />P100+11-&IS DOUBLE -a- <br />RECTANGULAR DUCT <br />Iw+D51sz"&wI _9._) <br />SUPPORTS REQUIRED <br />._2 . <br />• 1l2 GALV THREADED ROD <br />BEARER REQUIRED <br />►1001,1416 DOUBLE STRUT <br />OVAL DUCT <br />I.H. S IB2- A WIDTH S BB' <br />SUPPORTS REQUIRED <br />• +Y1 GALV THREADED ROD <br />BEARER REQUIRED <br />• H'f_%M DOUBLE STRUT <br />RECTANGULAR DUCT <br />(W.p<I.. AWIDTH <120^) <br />SUPPORTS REQUIRED_ <br />• +G: GALV THREADED ROD <br />BEARER REQUIRED <br />i.UI A RTEEL ANGLE <br />D>< <br />OVAL DUCT <br />Iw+B S t92" a w o"I <br />SUPPORTS REQUIRED <br />112 GALV THREADED ROD <br />BEARER RESTEELQUIRED <br />RECTANGULAR DUCT <br />I W.. S 1.1. R5 14A-) <br />SUPPORTS REQUIRED <br />• 11S GALV THREADED ROD <br />BEARER REQUIRED <br />OVAL DUCT <br />(w+D<112-aWIDTH <br />SUPPORTS REQUIRED <br />BEARER REQUIRED <br />ROUND DUCT ROUND DUCT ROUND DUCT ROUND DUCT ROUND DUCT <br />(DIAMETERS 1S0") (DIAMETER 5 --) (DIAMETER 5 380") (DIAMETERS BAB^) (DIAMETER S Us-) S ALL SEISMIC <br />ffazcmam.EII <br />SUPPORTS REQUIRED SUPPORTS REQUIRED SUPPORTS REQUIRED SUPPORTS REQUIRED SUPPORTS REQUIRED <br />. NO2 CABW STUD IPUTl+O R . NOz CASLl: aTUD (PUT) +S PT • Le GALV THRSADED ROD- �e caw ix REAOED Roo •SIB GALV THREADED ROD <br />• NO2 CABLE: BARREL PAN 10 FT • NO2 GABLE: BARREL PAN 1S FT <br />BEARER REQUIRED BEARER REQUIRED BEARER REQUIRED BEARER REQUIRED BEARER REQUIRED <br />• BINDLE CABLE LOOP • SINOIE CABLE LOOP .12 OR BAND LOOP OR PEAR . 12 GA BOTTOM SADDLE ONLY • 12 OA TOP AND BOTTOM SADDLE <br />Hermanson <br />Building Today, Defining Tomorrow <br />Hermanson Company LLP <br />1221 2rld Avenue North <br />Kent, Washington 98032 <br />Tel: (206) 575-9700 <br />Fax:(206) 575-9800 <br />Mmv.hermanson.com <br />Contractor Reg J: HERMACL0058J <br />RTU <br />REPLACE <br />EVERETT MALL PLAZA, SUITE M <br />1203 SE EVERETT MALL WAY <br />EVERETT, WA 98208 <br />DID <br />J�9 OF WASy <br />Oe 0 4j' M•2 <br />36149 <br />ONAL 6 <br />October 12, 202? <br />ISSUE FOR PERMIT <br />Revisions <br />_ 10/07/22 JMH ISSUE FOR PERMIT <br />No. Date By Description <br />Design Team <br />Design JMH <br />Drawn FVP <br />Checked DTN <br />Pre -Construction Number 14-22-22760 <br />Construction Number <br />Issue Date 10/07/22 <br />CONSTRUCTION <br />STANDARDS <br />- HVAC <br />M0.02 <br />