My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1706 HOYT AVE 2023-04-03
>
Address Records
>
HOYT AVE
>
1706
>
1706 HOYT AVE 2023-04-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2023 8:06:25 AM
Creation date
3/16/2023 3:03:14 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
1706
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a rmuct apecittcatiuns <br />Decibels([dB(Q) <br />Max @ 100% load <br />Min @ minload <br />Compressor <br />RLA <br />LRA <br />Condenser Fan Motor <br />79 <br />60 <br />19 29 <br />45— 58.1 <br />Horsepower (HP) <br />1/6 1/3 <br />FLA <br />1.0 2.5 <br />Refrigeration System <br />Refrigerant Line Size' <br />Liquid Line Size (OD) <br />3/8" 3/8" <br />Suction Line Size (OD) <br />3/4" 7/8" <br />Refrigerant Connection Size <br />Liquid Valve Size (OD) <br />3/8" 3/8" <br />Suction Valve Size (OD) <br />3/4" 7/8" <br />Refrigerant Charge (R410-A, oz) <br />121 170 <br />Expansion Device <br />EEV EEV <br />Maximum Line Length <br />100 FT 100 FT <br />Maximum Elevation Difference <br />50 FT 50 FT <br />Operating Range <br />Cooling <br />40°F-125°F <br />Heating <br />5°F-86'F <br />Electrical Data <br />Voltage -Phase -Hz <br />208/230.1.60 208/230.1.60 <br />Minimum Circuit Ampacity' <br />24.8 38.8 <br />Max. Overcurrent Protection' <br />40 60 <br />Min/Max Volts <br />172V/270V <br />Weight <br />Net Weight (without packaging) <br />I 159 196 <br />Gross Weight (including packaging)' <br />I 190 227 <br />Dimensions <br />Unit L x W x H (in.) <br />294/8 x 29.1/8 x 24-15/16 29-1/8 x 29-1/8 x 33.3/16 <br />Outdoor Coil <br />Net face area - sq.ft. Outer Coil <br />13.6 18.4 <br />Tube diameter -in. <br />9/32" (7mm) 9/32" (7mm) <br />No.of rows <br />2 2 <br />Fins per inch <br />17 19 <br />Table 1 <br />' Tested and rated in accordance with AHRI Standard 210/240. <br />' Wire size should be determined in accordance with National Electrical Codes; <br />extensive wire runs will require larger wire sizes. <br />a Must use time -delay fuses or HACR-type circuit breakers of the same size as <br />noted. <br />Always check the rating plate for electrical data on the unit being <br />' Weight values are estimated. <br />' installed. <br />- • Unit is factory charged with refrigerant for 15' of " liquid line. <br />System charge must be adjusted per Installation Instructions Final <br />Charge Procedure. <br />• TXV is required at indoor unit to match our outdoor unit. <br />Data subject to change 12.2020 1 Bosch Thermotechnology Corp. <br />
The URL can be used to link to this page
Your browser does not support the video tag.