Laserfiche WebLink
SCOPE OF WORK <br />TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE <br />LOCATED AT 1815 LOMBARD AVE, EVERETT, WA 98201, USA. <br />THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY <br />GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. <br />THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. <br />EQUIPMENT SUMMARY <br />9 Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES <br />9 ENPHASE IQ8PLUS-72-2-US (240V) MICROINVERTERS <br />GENERAL NOTES <br />• THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND <br />OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE <br />MODIFICATIONS IN CONSTRUCTION DETAILS. <br />• ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR <br />INSTALLATION OF ANY EQUIPMENT AT SITE. <br />• CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL <br />PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. <br />• CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS <br />AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER <br />BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND <br />ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE <br />CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL <br />COMPENSATION. <br />• DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, <br />ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE <br />CONTRACTOR AT NO ADDITIONAL COST. <br />• THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND <br />COMPLETION OF THE WORK WITH APPROVED MATERIALS. <br />• NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE <br />ARCHITECT. <br />• CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING <br />PERMIT IS PROPERLY DISPLAYED. <br />• ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE <br />WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, THE DEPARTMENT OF <br />ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. <br />• IT 1 S ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL <br />PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. <br />THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. <br />• ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO <br />BE PAINTED BY GENERAL CONTRACTOR. <br />• THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE <br />LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. <br />• THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, <br />ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. <br />• CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. <br />I GOVERNING CODES I <br />2018 INTERNATIONAL FIRE CODE <br />2018 INTERNATIONAL BUILDING CODE <br />2018 INTERNATIONAL RESIDENTIAL CODE <br />WASHINGTON ADMINISTRATIVE CODE (WAC) <br />2020 NATIONAL ELECTRICAL CODE <br />I AHJ NAME: CITY OF EVERETT I <br />WIRING AND CONDUIT NOTES <br />• ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND <br />APPROVAL FOR THE SITE APPLICATIONS <br />• ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV WIRE, OR <br />PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALENT; ROUTED TO <br />SOURCE CIRCUIT COMBINER BOXES AS REQUIRED <br />• ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE <br />DERATED ACCORDING TO AS PER LATEST NEC CODE. <br />• EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV <br />RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE <br />USED TO PROTECT WIRE FROM SHARP EDGES <br />• PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 <br />INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 1000V AS PER <br />APPLICABLE NEC <br />• 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER <br />VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE <br />MEANS <br />• ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION <br />• VOLTAGE DROP LIMITED TO 2% <br />• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, <br />PHASE B OR 1-2- RED, PHASE C OR 1-3- BLUE, NEUTRAL- WHITE/GRAY <br />• VOLTAGE DROP LIMITED TO 2% <br />• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE AOR L1- BLACK, <br />PHASE B OR 1-2- RED, PHASE C OR 1-3- BLUE, NEUTRAL- WHITE/GRAY <br />SYSTEM RATING <br />PHOTOVOLTAIC SYSTEM FIRE <br />CLASSIFICATION LISTING IN <br />ACCORDANCE WITH UL 1703 <br />STANDARD. <br />3.600 kWDC <br />2.700 kWAC <br />SHEETINDEX <br />PV1 <br />COVER PAGE <br />PV2 <br />SITE PLAN <br />PV3 <br />ROOF PLAN <br />PV4 <br />STRING LAYOUT & BOM <br />PV5-PV6 <br />ATTACHMENT DETAILS <br />PV7 <br />ELECTRICAL LINE & CALCS. <br />PV8 <br />SPECIFICATIONS & NOTES <br />PV9-PV10 <br />SIGNAGE <br />PV11 <br />JOB SAFETY PLAN <br />PV12-PV21 <br />I EQUIPMENT SPECIFICATIONS <br />HOUSE PHOTO SCALE: NTS <br />egion Park <br />19 <br />ELECTRICAL NOTES <br />• ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />• ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET <br />ENVIRONMENT. <br />NORTHWEST <br />• WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY <br />EVERETT <br />TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />• WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL <br />COMPLY WITH NEC 110.26. <br />• WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE <br />CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />• ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />• MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE <br />SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. <br />• MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE <br />Everett <br />n' o <br />�IVo gleucliaTerms of Use Re <br />VICINITY MAP <br />\� <br />Spencer <br />Island Pa <br />SCALE: NTS <br />Lum'160 <br />SMART ENERGY TODAY <br />(SET) <br />1550 DIGITAL DR, LEHI, UT <br />84043, USA <br />SYSTEM INFO <br />(9) Q CELLS <br />Q.PEAK DUO BILK ML-G10+ <br />(40OW) <br />(9) ENPHASE <br />IQ8PLUS-72-2-US (240V) <br />DC SYSTEM SIZE: 3.600 kWDC <br />AC SYSTEM SIZE: 2.700 kWAC <br />REVISIONS <br />DESCRIPTION DATE REV <br />PROJECT NAME & ADDRESS <br />0 <br />J <br />Q LU <br />z U <br />O z <br />W <br />U � <br />Q <br />U) <br />W <br />a <br />75 <br />Q <br />U) <br />1-7 <br />N <br />00 <br />O7 <br />Q <br />W <br />of <br />W <br />Lu <br />LLI <br />> <br />Q <br />0 <br />Q <br />00 <br />2 <br />O <br />J <br />Ln <br />CD <br />0 <br />I` <br />0 <br />0 <br />M <br />N <br />00 <br />M <br />0 <br />0 <br />z <br />D_ <br />EN <br />I DATE:12/3/2022 1 <br />SHEET NAME <br />COVER PAGE <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-1 <br />