My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2127 OAKES AVE 2023-04-26
>
Address Records
>
OAKES AVE
>
2127
>
2127 OAKES AVE 2023-04-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2023 3:07:06 PM
Creation date
3/16/2023 3:24:21 PM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
2127
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SOLGEN <br />P O W E R <br />July 13, 2022 <br />Subject: Proposed Solar Panel Installation <br />Stephen Ehresman Residence, 2127 Oakes Ave, Everett, WA <br />To Whom it May Concern, <br />Our engineering department has reviewed information, gathered by our field crews, related to the proposed solar <br />panel installation at the above -referenced address. The purpose of our review was to determine the structural <br />adequacy of the existing roof. Based on our review and analysis of the available information, and in accordance <br />with governing building codes, it is our professional opinion that the existing structure is permitted to remain <br />unaltered for the proposed solar installation. <br />Design Parameter Summary <br />Governing Building Code: 2018 Washington Building Code (2018 IBC) <br />Risk Category: II <br />Design Wind Speed: 110 mph (per ASCE 7-16) <br />Ground Snow Load: 15 psf <br />Roof Information <br />Roof Structure: 2x4 Rafters @ 24" O.C. <br />Roofing Material: Asphalt Shingles (2 layers) <br />Roof Slope: 12 degrees <br />Roof Connection Details <br />RT Minis into 2x rafters or truss top chords at 48" O.C., install per design drawings and manufacturer specs <br />Locations per design drawings <br />Note: Required embedment length excludes the tapered tip of the screw, and embedment into sheathing. <br />Analysis <br />The proposed installation - including weight of panels, racking, and mounts - will be approximately 2.66 psf. In the <br />areas where panels are installed, roof live loads will not be present. The reduction of roof live load is adequate to <br />fully or partially compensate for the addition of the panel installation. Because the member forces in the area of <br />the solar panels are not increased by more than 5%, the stresses in the members are not increased by more than <br />5%, and so per section 806.2 of the International Existing Building Code (IEBC), the structure need not be altered for <br />gravity loading. <br />The proposed installation will be 6" max. above the roof surface (flush mounted) and parallel to the roof surface. <br />Therefore, any increase in wind loading on the building structure from the solar panel installation is expected to be <br />negligible. Wind is the governing lateral load case. Because the increase in lateral loading is not increased by more <br />than 10%, per section 806.3 of the adopted IEBC, the structure need not be altered for lateral loading. <br />Wind uplift on the panels has been calculated in accordance with the relevant provisions of ASCE 7-16. This loading <br />has been used to verify the adequacy of the connection specified above. Connection locations should be in <br />accordance with design drawings. <br />rnnrhicinn <br />
The URL can be used to link to this page
Your browser does not support the video tag.