My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2825 COLBY AVE HERITAGE BANK 2023-03-30
>
Address Records
>
COLBY AVE
>
2825
>
HERITAGE BANK
>
2825 COLBY AVE HERITAGE BANK 2023-03-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2023 11:02:29 AM
Creation date
3/16/2023 3:31:50 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2825
Tenant Name
HERITAGE BANK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMPRESSION STRUTS <br />ATTACHED <br />WALL <br />BE <br />B B <br />B <br />BE <br />I B <br />B <br />B <br />AND LATERAL BRACING <br />TO BE LOCATED 6'-0" <br />1 <br />MAX E.W. FROM WALLS <br />AND DISCONTINUOUS <br />CEILING SURFACES <br />CENTER SMALL <br />u <br />'-"ARMSTRONG SEISMIC RX <br />2 PERIMETER CLOSURE AT <br />-92 SEISMIC CATEGORY C. D,E, F 7/8� <br />u <br />PENETRATIONS WITHIN <br />UNATTACHED WAI <br />THE CEILING GRID; <br />EVENLY SPACE T <br />MULTIPLE <br />PENETRATIONS <br />WITHIN A SINGLE GRID <br />SEISMIC JOINTS WHERE <br />3 CAN USE BERK CL <br />1a2 REQUIRED TO LIMIT CEILING POP RIVET NOTE[ <br />AREAS TO 2500 SF <br />'B/P' ON 1/ 1-9.2 FO <br />4 COMPRESSION STRUTS AND CATEGORYD,E,F <br />192 LATERAL BRACING WHERE <br />A <br />71 <br />X-X" <br />u <br />u <br />MODULE <br />"HEAVY-DUTY'CEILING <br />SUPPORT SYSTEM <br />SIMILAR TO <br />CEILING AREA> 144 SF <br />HANGER WIRE AT <br />12 GA VERTICAL HANGER WIRES <br />4 TOCEILINGGRID MAINBEAMSAT PERIMETER MAIN <br />4'-0" O.C. EACH WAY WITH 3 AND PERIMETER <br />TIGHT WRAPS CROSS TEE <br />1-9.2 <br />ARMSTRONG SEISMIC o <br />RX FOR SEISMIC DESIGN 1 <br />CATEGORY'D, E, OR F' a L1 u w <br />PER IBC 1613.1 G B 1 2 <br />OFF MODULE MAIN I G <br />a <br />BEAMS TO USE STAG�UNAT-TACHED <br />CEILING GRID FIXTURE BRACING <br />5 AT ELECTRICAL AND <br />CLIP1-9.2 MECHANICAL FIXTURES <br />WALL <br />CEILING TYPE L. XX'-0"AFF <br />CEILING ELEVATION AFF B.O. HEADER <br />OCEILING GRID DETAIL DIAGRAM - TYPICAL <br />SCALE: 3"=1'W <br />NO.9 GA. LATERAL SUPPORT WIRE WITHIN 3" <br />OF EACH CORNER OF LIGHT FIXTURE. SPLAY <br />WIRES AS SHOWN AND FASTEN TO BEAM OR <br />PURLIN. MIN. OF 3 WIRE TURNS EACH. <br />CONNECTION POINT <br />N0.9 GA. LATERAL SUPPORT WIRE AT <br />CENTER ENDS OF EA. FIXTURE. FIXTURE <br />SUPPORT WIRE SUPPLIED BY CEILING <br />CONTRACTOR Q \ Z; <br />OLIGHT FIXTURE BRACING DIAGRAM <br />SCALE: N.T.S. <br />a2 <br />60° MAX. TYP. <br />45� <br />45° <br />RECESSED FLUORESCENT <br />FIXTURE <br />MAIN STRUCTURAL <br />RUNNER 4'-0" O.C. <br />8" <br />ARMSTRONG STABILIZER <br />3AR OR OTHER SUITABLE <br />SYSTEM TO KEEP PERIMETER <br />:OMPONENTSFROM <br />SPREADING APART <br />SEISMIC RX PERIMETER TRIM <br />3Y ARMSTRONG CEILING <br />:j <br />NOTES: <br />1. LATERAL BRACING CLUSTER: (4)12 GA. GALV. SOFT -ANNEALED MILD STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF <br />CROSS T' AND SPLAYED 90 DEGREES FROM EACH OTHER AT 45 DEGREES MAX. ABOVE HORIZONTAL. CLUSTERS PLACED 12'4" <br />O.C. MAX. AND 6-0" MAX. FROM EACH WALL. WIRES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT. <br />2. SUSPENSION WIRE: 12 GA. GALV. SOFT -ANNEALED MILD STEEL WIRE ENCASED IN DIAM. CONDUIT (FOR UPLIFT RESTRAINT); <br />8" MAX. SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS'T. CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND <br />SUSPENSION WIRES TO OCCUR AT 4'-0" O.C. MAX. EACH WAY. <br />Bg .° <br />NOTE #2 <br />3 TURNS MIN. <br />C WITHIN 3" TYP. <br />© NOTE #1 NOTE #1 <br />PROVIDE CEILING SEISMIC JOINT CLIP IN MAIN <br />BEAMS SIMILAR TO ARMSTRONG SJMR AS <br />�.l <br />O NECESSARY DIVIDING CEILING INTO AREAS NO <br />TYPICAL HEAVY DUTY <br />7/8" SUSPENDED CEILING <br />g ° GREATER THAN 2,500 S.F. <br />ATTACHED WALLS AT GRID SYSTEM BY <br />CATEGORY D, E & F USE ARMSTRONG <br />BERC2 BY ARMSTRONG <br />CEILING NOTED AS 'B' <br />ON 1/ 1-9.2, CATEGORY C <br />ALWAYS USES BERC2 <br />OSUSPENDED CEILING AT PERIMETER SUPPORT <br />O <br />EXPANSION JOINT >2500SF <br />SCALE:1 i/2'=1'A" <br />SCALE: 3'=V-0- <br />(E) CONCRETE (E) CONCRETE <br />OVER METAL DECK OVER METAL DECK <br />7 <br />STRUCTURAL DECK <br />5/8"TYPE'X' GYPSUM BOARD <br />3 5/8" METAL STUDS AT 24"O.C. <br />7�(2)#B <br />NOTE: WHERE HEADER IS PART <br />CEILING CLIP W/CEILING CLIP AS <br />OF A FIRE -RATED CEILING <br />BRACE TO STRUCTURE, 4'A"O.C. <br />ANCHORAGE PE(1}0.157"O HILTI <br />SCREWS <br />ASSEMBLY, GYPSUM BOARD <br />ASTME580 EMBEX-J EMBEDDED <br />MUST GO TO THE STRUCTURAL <br />MIN. LATERAL STUD SPACING <br />1-1/2" INTO1-1/2"INTO <br />p <br />DECK ON BOTH SIDES WITH FIRE <br />UPPER FLUTEUPPER FLUTE <br />PROOFING AT TOP TRACK 4"MIN(3) <br />TURNS WITHIN1-112"OF <br />END <br />OF WIRECOMPRESSION <br />-� <br />STRUT PER <br />CEILING AS SCHEDULED, <br />SEISMIC BRACE 4/1-9.2 <br />SEE REFLECTED CEILING <br />WIRE <br />PLANS FOR TYPE AND ELEVATION <br />OANCHORAGE DETAIL <br />O <br />HEADER DETAIL <br />SCALE: 3"= I' W <br />SCALE. N T.S. <br />45° MAX. TYP. RUNNER ENDS AT <br />OPPOSITE WALLS <br />MAIN RUNNER, 2" MAX. TYP. <br />TO FLOAT FREE <br />HEAVYDUTY <br />ON PERIMETER <br />CROSS T" <br />ANGLE. PROVIDE <br />3/4" CLEARANCE <br />VIEW SHOWING LATERAL BRACING <br />BETWEEN ENDS OF <br />GRID & WALL <br />CLUSTER AND SUSPENSION WIRE <br />OCEILING BRACING DIAGRAM <br />SCALE: N.T.S. <br />fEM PENETRATING CEILING SHALL BE <br />IUPPORTED AND SEISMICALLY BRACED <br />VDEPENDENT OF CEILING <br />;EILING PANEL AS SCHEDULED <br />:SCUTCHEON ATTACHED TO ITEM <br />OCEILING PENETRATION DETAIL <br />SCALE: N.T.S. <br />NOTE: COORDINATEACCESS <br />PANEL LOCATION WITH <br />ARCHITECT PRIOR TO INSTALL. <br />HANGER WIRE W/ (3) TURNS <br />1/1 /2"FRAMING CHANNELS <br />ALL (4) SIDES <br />1 1/2" MAIN RUNNER <br />718" FURRING CHANNEL <br />GWB W/J MOLDING <br />FLUSH FRAMELESS RECESSED <br />PANEL ACCESS -DOOR FASTENED <br />TO FRAMING CHANNELS <br />GWB INFILL @ ACCESS PANEL <br />n GWB CEILING ACCESS PANEL DETAIL <br />SCALE: N.T.S. <br />N <br />U <br />W <br />2 <br />u <br />I1..� <br />a <br />V <br />CL <br />O <br />N <br />N <br />LLI <br />Z <br />O <br />O <br />C W <br />N P <br />L <br />N O) <br />01m <br />HERITAGE BANK <br />FRONTIER BANK BLD <br />2831 COLBY AVE <br />EVERETT, WA 98201 <br />DESIGN JPC <br />DRAWN CIS <br />CHECKED AC <br />NO. 22-0419 <br />ezaa REGISTERED <br />AL`R^�C�yH)IITECCT <br />CHARLOTTE PATfER50N <br />STATE OF WASHINGTON <br />7/13/2022 PERMIT REVIEW SET <br />7/1812022 PERMIT SET <br />Ceiling Details <br />1-9.2 <br />2017. JPC ArcNteUs. PLLC <br />
The URL can be used to link to this page
Your browser does not support the video tag.