My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10318 EVERGREEN WAY WOODS COFFEE 2023-03-30
>
Address Records
>
EVERGREEN WAY
>
10318
>
WOODS COFFEE
>
10318 EVERGREEN WAY WOODS COFFEE 2023-03-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2023 2:03:59 PM
Creation date
3/16/2023 3:58:59 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10318
Tenant Name
WOODS COFFEE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AIR QUALITY SCHEDULE <br />A <br />B <br />C <br />D <br />E <br />F <br />I G <br />H <br />1 <br />J <br />K <br />I L <br />I M <br />I N <br />O <br />P <br />Q <br />R <br />s <br />Sysl. <br />Room N <br />Sarong <br />Table 403.3 <br />Occupant <br />Classification <br />Area <br />Sgft <br />Table <br />403.3 <br />Persons/ <br />1000sgft <br />Outside <br />Air <br />Cfm/ <br />Sgft <br />Outside <br />Air <br />Crm/ <br />Person <br />Number <br />People <br />Code <br />Cfm/Sgft <br />CA Crm <br />Code <br />Cfm/Per. <br />CA CI <br />Design <br />CA Cirri <br />% <br />CA <br />HRU <br />Supply <br />Total <br />Cf. <br />Code <br />Exhaust <br />Cfm/Sgft <br />EA Cfin <br />Code <br />Exhaust <br />Total <br />Cfin <br />Exhaust <br />Fan <br />No. <br />Exhaust <br />Airflow <br />CFM <br />WH-1 <br />Unisex RR Exh 50-70/Fixt. <br />Toilet <br />55 <br />interim <br />EF-3— <br />50 <br />HRU-1 <br />Work Room m <br />Kitchen <br />308 <br />20 <br />0.18 <br />7.5 <br />6 <br />55.4 <br />46 <br />140 <br />8.8% <br />1,600 <br />0.7 <br />216 <br />EF-1— <br />216 <br />HRU-2A <br />Bev. Prep. 2A (T) <br />Kitchen <br />121 <br />20 <br />0.18 <br />7.5 <br />2 <br />21.8 <br />18 <br />80 <br />10.0°/h <br />800 <br />0.7 <br />85 <br />EF-2A" <br />85 <br />HRU-2B <br />Bev. Prep. 2B m <br />Kitchen <br />112 <br />20 <br />0.18 <br />T5 <br />2 <br />20.2 <br />17 <br />80 <br />10.0% <br />800 <br />0.7 <br />78 <br />EF-2B" <br />80 <br />TOTAL <br />596 <br />3. <br />379 <br />431 <br />(T) indicates thermostat location- <br />' Minimum percentage of outside air at the (HRU) must be set equal to the room with the highest calculated percent of outside air. <br />" Exhaust fan provided by Contractor <br />I EF-3 controlled (on - oM by a Motion Detector <br />Ventilation: 2021 Intmational MC, TABLE 403.3.1.1 Mechanical Ventilation. <br />DESIGN CRITERIA <br />1. Heating, Ventilating and Air Conditioning (HVAC): <br />1 Heating/Cooling Loads: <br />a. Calculations per Trane Load Calculation Program, Ultra Edition, based on ASHRAE Guide. <br />Calculations to comply with State of Washington Energy Code. <br />b. Summer design: 75F degrees indoors: 84F degrees dry bulb and 65F degrees wet bulb outdoors. <br />c. Winter design: 72F degrees indoors; 24F degrees outdoors. <br />d. Elevation: 410 feet <br />2 Interior Loads: <br />Room <br />Lights <br />Watts <br />SgFt <br />Equipment <br />Number <br />of <br />People <br />People <br />Vent <br />Rate <br />CFM/ <br />Person <br />Seri. <br />BTU/ <br />SgFt <br />Lat. <br />BTU/ <br />SgFt/ <br />Sen. <br />per <br />Person <br />Lat. <br />per <br />Person <br />Beverage Prep. <br />1 <br />118 <br />8 <br />5 <br />250 <br />200 <br />0.7 Cfm/sgft <br />Corridor <br />1 <br />0 <br />0 <br />0.06Crm/sqft <br />Kitchen <br />1 <br />110 <br />6 <br />5 <br />300 <br />250 <br />0.7 Cfin/sqft <br />Restrooms <br />1 <br />0 <br />0 <br />Exhaust <br />3 Ventilation: <br />a. Per International Mechanical Code Table 403.3. <br />b. Toilet Rooms: 50Cfm per water closet or urinal exhausted. <br />4 Noise Criteria: <br />The mechanical system shall be designed such that the system will not produce noise levels in the space <br />higher than indicated. Recommended indoor design goals from the ASHRAE Handbook. <br />Indoor Area` <br />Room dbA" or NC" <br />Ia. Toilet Rooms 45 40 <br />b. Kitchen 70 65 <br />` This recommended criteria is for unoccupied spaces with all mechanical systems operating. <br />" Design goals can be increased by 5 db when dictated by budget constraints or when noise intrusion <br />DRAWING INDEX <br />M0.0 - HVAC DESIGN CRITERIA, SYMBOLS, & ABBREVIATIONS <br />MIA - HVAC FIRST FLOOR PLAN <br />M1.2 - HVAC LOFT PLAN <br />M1.3 - HVAC ROOF PLAN <br />M4.0 - HVAC SCHEDULES <br />M4.1 - HVAC SPECIFICATIONS <br />ABBREVIATIONS <br />4) Point of connection to Existing <br />(E) <br />Existing <br />(N) <br />New <br />(R) <br />Remove <br />(RL) <br />Relocate <br />Abv. <br />Above <br />AFF <br />Above Finished Floor <br />AP <br />Access Panel <br />BFC <br />Below Finished Ceiling <br />SFF <br />Below Finished Floor <br />BFG <br />Below Finished Grade <br />BS <br />Branch Selector <br />CA <br />Combustion Air <br />CC <br />Cooling Coil <br />CFM <br />Cubic Feet per Minute <br />CIg. <br />Ceiling <br />Col <br />Column <br />D <br />Drop <br />Db <br />Dry Bulb Temperature, F Degrees <br />dB <br />Decibels <br />EA <br />Exhaust Air <br />EF <br />Exhaust Fan <br />EG <br />Exhaust Grille <br />EX <br />Extractor <br />FC <br />Flexible Connection <br />Fir. <br />Floor <br />' or Ft. <br />Feet <br />Fig. <br />Footing <br />FP <br />Fire Protection <br />GPM <br />Gallons Per Minute <br />HP <br />Horsepower or Heat Pump <br />HRC <br />Heat Recovery Concealed Unit <br />" or In. <br />Inches <br />L <br />Louver <br />MAU <br />Make-up Air Unit <br />Max. <br />Maximum <br />MBH <br />1000 BTU/Hr. <br />Min. <br />Minimum <br />N <br />North <br />NA <br />Not Applicable <br />Nom. <br />Nominal <br />NITS <br />Not to Scale <br />CA <br />Outside Air <br />PSI <br />Pounds per Square Inch <br />R <br />Riser <br />RA <br />Return Air <br />RH <br />Radiant Heater <br />RTU <br />Roof Top Unit <br />RV <br />Roof Vent <br />0 <br />Round <br />TVE <br />Turning Vane Extractor <br />TWU <br />Through -Wall Unit <br />Typ <br />Typical <br />V <br />Vent <br />VHRU <br />Multi V Heat Recovery Unit <br />VI <br />Vibration Isolator <br />VVD <br />Variable Volume Damper <br />Wb <br />Wet Bulb Temperature, F Degrees <br />WH <br />Wall Heater <br />GENERAL NOTES <br />HVAC SYMBOLS <br />A PROVIDE PIPING, EQUIPMENT, AND MATERIALS IN <br />® ® <br />SUPPLY AIR DUCT (UP & DN) <br />VANED ELBOW (PROVIDE <br />ACCORDANCE WITH APPLICABLE MECHANICAL CODE <br />ON ALL SQ. & RECT. <br />REGULATIONS AND STANDARDS. AND PER THE <br />E 11 <br />RETURN AIR DUCT (UP & DN) <br />ELBOWS, EVEN IF SYMBOL <br />MANUFACTURERS INSTALLATION INSTRUCTIONS. <br />IS MISSING) <br />Z <br />EXHAUST AIR DUCT (UP & DN) <br />B CONDITIONS SHOWN ON THE PLANS RELATIVE TO THE WORK <br />STANDARD RADIUS ELBOW <br />TO BE PERFORMED ARE BASED ON THE BEST INFORMATION <br />OUTSIDE AIR <br />AVAILABLE BUT ARE SUBJECT TO VERIFICATION BY THE <br />® <br />OA <br />AIR QUALITY SENSOR (CO2) <br />CONTRACTOR. VERIFY AND COORDINATE LOCATIONS AND <br />1 124 <br />NEW DUCT- WIDTH x DEPTH (NET INSIDE) <br />ELEVATIONS OF DUCTWORK AND PIPING CORRECT <br />CARBON MONOXIDE SENSOR <br />DEFICIENCIES CAUSED BY FAILURE TO PERFORM SUCH <br />® <br />INCLINE RISE, IN DIRECTION OF AIR FLOW <br />VERIFICATION AND COORDINATION AT NO EXPENSE TO THE <br />O <br />THERMOSTAT <br />OWNER. IMMEDIATELY NOTIFY ARCHITECT OF FIELD <br />® <br />INCLINE DROP, IN DIRECTION OF AIR FLOW <br />CONDITIONS IN CONFLICT WITH THE PLANS. <br />O <br />TEMPERATURE SENSOR <br />SQUARE TO ROUND TRANSITION <br />C SAW CUTTING OF ANY FLOOR AND CORE DRILLING HOLES <br />OM <br />MOTION SENSOR <br />(NOT SHOWN ON THE ARCHITECTURAL DRAWINGS) LARGER <br />ADJUSTABLE EXTRACTOR <br />THAN EIGHT INCHES DIAMETER IN STRUCTURAL WALLS, <br />EX <br />SD <br />SMOKE DETECTOR <br />FLOOR OR ROOF REQUIRES THE APPROVAL OF A <br />FLEXIBLE CONNECTION <br />STRUCTURAL ENGINEER REGISTERED IN THE STATE OF <br />A-1 <br />DIFFUSER to. <br />WASHINGTON. CONTRACTOR TO RETAIN THE SERVICES OF <br />MANUAL VOLUME DAMPER <br />THE STRUCTURAL ENGINEER AND FORWARD WET STAMPED <br />FD <br />RTU-1 <br />EQUIPMENT ID. <br />STRUCTURAL CALCULATIONS TO THE ARCHITECT PRIOR TO <br />FIRE DAMPER <br />BEGINNING WORK. HOLES SMALLER THAN EIGHT INCHES IN <br />FSD <br />DIAMETER IN STRUCTURAL WALLS, FLOOR OR ROOF SHALL <br />FIRE / SMOKE DAMPER <br />BE REVIEWED AND AUTHORIZED BY THE ARCHITECT INSD� <br />WRITING PRIOR TO BEGINNING OF WORK. <br />SMOKE DAMPER <br />MOTORIZED DAMPER <br />ATP ENGINEERING, INC. <br />MECHANICAL CONSULTANTS <br />18407 Andis Road <br />RURLJNGTON, WA 98233 <br />Office (360)757-2099 <br />Cell (503)701-4221 <br />Fax (360)757-2097 <br />larrym@atpeinc.com <br />11382 Q <br />�o'Fs`SIONALAGl�ww <br />5/18/2023 <br />Ld <br />L.d p <br />Li N <br />Li 00 <br />® <br />U � Q <br />0) <br />® j (I) <br />® W N <br />W <br />E <br />No. <br />Revision/Issue <br />Date <br />SD <br />Schematic Design <br />07-22-21 <br />DD <br />Design Development <br />08-11-21 <br />CD <br />Permit Set <br />10-22-21 <br />sneer rue <br />HVAC - DESIGN <br />CRITERIA, SYMBOLS, <br />& ABBREVIATIONS <br />Proiect N <br />Drawn <br />Sh- r. :. <br />21-012.0 <br />iC <br />M0.0 <br />Print Data <br />10-22-21 <br />CM1ecLI LM <br />some <br />AS NOTED <br />
The URL can be used to link to this page
Your browser does not support the video tag.