Laserfiche WebLink
CEILING EXHAUST FAN (EF) SCHEDULE <br />Unit Symbol/Serving: <br />EF-2A / Bev Prep <br />EF-1 / Work Rm <br />Remarks <br />EF-2BI Bev Prep <br />EFJ I Toilet Rm <br />Cook <br />Cook <br />Model No: <br />GC-186 <br />GC-422 <br />Type: <br />Ceiling <br />Ceiling <br />Exhaust (CFM) <br />60 - 170 <br />180 - 300 <br />TSP (In. Water): <br />0.25 <br />0.25 <br />Noise (dbA/Sones): <br />44 / 3.5 <br />47 / 4.0 <br />Wheel Max RPM's: <br />894 <br />1490 <br />Size (Inches) (W x L x H): <br />12-3/4 x 12 x 7 <br />17 x 11-7/8 x 11-7/8 <br />Weight (Lbs.): <br />22 <br />38 <br />Electrical <br />- Motor: <br />73 watts <br />90 watts <br />- Volts: <br />115 <br />115 <br />Phase: <br />1 <br />1 <br />Options: <br />- Radiation Damper <br />No <br />No <br />- Speed Control #: <br />Yes <br />Yes <br />-Backdreft damper. <br />Yes <br />Yes <br />- See Below <br />Yes 1. <br />Yes 1. <br />- Curb Height <br />NA <br />NA <br />EFJ - Motion Detector <br />Controls: <br />EF2A & 28 - Light Switch <br />Light Switch <br />Quantity: <br />3 <br />1 <br />NOTE: <br />1. All tans with 113 HP and smaller motors to have LekTrol solid-state variable <br />speed control (50 - 100 % air flaw) located above ceiling at fan (speed control <br />adjustment by air balancer and maintenance personnel only). <br />BOOSTER FAN (BF) SCHEDULE <br />Unit Symbol: <br />BF-2A & -2B <br />BF-1 <br />Remarks <br />Serving / Location: <br />HRU-2A / OA <br />HRU-1 / OA <br />HRU-28 / OA <br />Manufacturer <br />FanTech <br />FanTech <br />Model: <br />FR-100 <br />FR-160 <br />Nominal (CFM): <br />80 <br />216 <br />TSP (Inches Water): <br />0.5 <br />0.45 <br />Maximum Wheel (RPM): <br />1892 <br />2400 <br />Noise: dbA <br />54 <br />54 <br />Weight(Lbs.): <br />4113 <br />6112 <br />Size (Dia. X Length) Inchs <br />10 1/4 x 10 9/16 <br />12 12 x 13 <br />Vibration Isolation: <br />' <br />Electrical <br />-HP <br />20 watts <br />85 watts <br />-Volts: <br />115 <br />115 <br />-Phase <br />1 <br />1 <br />Control: <br />Interlock w/ Assoc. <br />Interlock w/ Assoc. <br />EF-2A & -28 <br />EF-1 <br />Quantity: <br />2 <br />1 <br />' Rubber in shear by equipment manufacturer. <br />HEAT RECOVERY UNIT (HRU) SCHEDULE <br />Nominal Cooling MBH: <br />36.2 <br />48.1 <br />Symbol, Serving: <br />HRU-2A / Beverage Prep. A <br />HRU-1 / Work <br />HRU-213 / Beverage Prep. B <br />Manufacture: <br />LG <br />LG <br />Type: <br />Four -Way Ceiling Cassette <br />Four -Way Ceiling Cassette <br />Model No.: w/ Bottom Service Access <br />ARNU363TMA4 <br />ARNU483TMC4 <br />Supply (CFM): <br />918 - 706 <br />1,300 - 883 <br />ESP (Inches Water): <br />0.12 <br />0.12 <br />Cooling Coil: <br />Yes - DX <br />Yes - DX <br />Direction Air Flow: <br />Vertical <br />Vertical <br />Cooling Total MBH: <br />362 <br />48.1 <br />SEER:: <br />See HP Unit <br />See HP Unit <br />Heating Total MBH: <br />40.6 <br />51.2 <br />COP: <br />See HP Unit <br />See HP Unit <br />Sound: (dBA) <br />37 - 44 <br />40 - 42 - 46 <br />Weight (Lb&): <br />71 <br />73 <br />Size H / W / D (Inches): <br />37-1/16 x 33-1/16 x 11-5116 <br />33-1/16 x 33-1/16 x 11-5/16 <br />Filter: <br />MERV8 <br />MERV8 <br />Refrigerant Type: <br />410A <br />41OA <br />Refrigerant Pipe: <br />- Liquid (Inches): <br />3/8 <br />3/8 <br />- Suction (Inches): <br />5/8 <br />5/8 <br />Drain Pipe (Inches): <br />1 <br />1 <br />Electrical <br />-KW, Heating <br />None <br />Now <br />-HP: Evap. Fan <br />_ Amp <br />1.3 <br />1.30 <br />-Volts/Phase: <br />208/230, 1-Phase <br />208/230, 1-Phase <br />Control: <br />' <br />Condensate Pump: <br />Yes <br />Yes <br />Quantity: <br />2 <br />1 <br />Elevation: 410 Ft. <br />` Programmable Wall Sensor cycles Heat and Cooling in sequence to maintain set point. <br />VRV BRANCH SELECTOR UNIT SCHEDULE <br />System Tag <br />Tag Reference <br />BS-1 <br />Model Number <br />PRHR033A <br />Number of Ports <br />3 <br />m <br />2D8/230V / 1-phase <br />Yes <br />Power Cig 20BVI230V (MCA) <br />0.06 <br />W <br />MFA <br />15 <br />Dim. (L x W x H) Inches: <br />18 15/16 x 19 1 /8 x 8 5/8 <br />BSU Location <br />Adi, t0 HP-1 <br />Weigh (lb): <br />37 <br />Quantity of HR Units connected: <br />3 <br />OUTDOOR UNIT (HP) SCHEDULE <br />System Tag <br />System 1 <br />HRC <br />Unit # <br />1 Load Sum. <br />j19.1 <br />Tag Reference <br />HP-1 <br />d <br />Htg. Load <br />Mil <br />Model NumberARUM072BTE5 <br />HRU-1 <br />40.6 <br />Modules <br />1 <br />HRU-2A <br />21.5 <br />Nominal CoolingCapacity (MBH) <br />72.0 <br />HRU-213 <br />48.1 <br />51.2 <br />Nominal Heating Capacity (MBH) <br />81.0 <br />Cooling Efficiency EER/IEER [or SEER] <br />---/ 28.4 <br />Heating COP @ 47"F [or HSPF] <br />3.83 <br />BS1-IA <br />103.4 <br />113.3 <br />Design Cooling Outdoor Temp DB ('F) <br />84 <br />a <br />Design Heating Outdoor Temp WB (°F) <br />64 <br />rj <br />Max Pipe Length from BC or 1st Joint (feet) <br />ReNg Pipe Dim High/Low Pressure (inch) (See Note 4) <br />€ o <br />Connected Cooling Total Capacity (BTU/h) <br />o m <br />Connected Heating Capacity (BTU/h) <br />if i' <br />Sound Pressure (dBA) <br />58 <br />h <br />Compressor Type <br />SCROLL <br />Compressor Quantity <br />1 <br />E <br />Refiigeram Type <br />R410A <br />tj <br />Pipe Dim: Liquid / High Press. Vapor / Low Press. Vapor <br />3/8" 1 518" l 3W' <br />Preliminary Added Field Charge (See Note 5) <br />o <br />Voltage / Phase <br />208 3-phase 3-wire <br />MCA 2081 <br />22.6 <br />Recommended Fuse Size (RFS) <br />35 <br />W <br />Maximum Fuse Size (MFS) <br />Weigh <br />Pountls (Ib): <br />430 <br />Dim <br />Width x Height x Length (inch): <br />36-518" x 66-17/32" x 29-29/32" <br />TOTAL <br />103.4 <br />113.3 <br />Applicable System Notes - See Notes Belowl <br />1, 2, 3, 4, 5, 6 <br />Use the <br />Block <br />Load <br />Notes & Options: <br />1 Nominal cooling capacities are based on indoor coil EAT of 921670F (DB/WB), outdoor of 95'F (DB) <br />2 Nominal heating capacities are based on outdoor EAT of 2WF (DB), 5"F (WB) <br />3 Efficiency values for EER, IEER, COP are based on AHRI 1230 test method for mixture of ducted & non -ducted indoor units. <br />4 For systems with multiple modules, refigemrd pipe dimensions indicate total system combined piping downstream of module twinning. <br />5 Added field charge listed is in addition to factory charge, this must be updated based upon final as -built piping layout. <br />6 Option: Base Pan Heater -ZPLT1A52A <br />GRILLE SIZE SCHEDULE <br />Price <br />i• See Air Quality Schedule for exact air Bow CFM. I <br />ATP ENGINEERING, INC. <br />MECHANICAL CONSULTANTS <br />18407 Andis Road <br />RURLINGTON, WA 98233 <br />Office (360)757-2099 <br />Cell (503)701-4221 <br />Fax (360)757-2097 <br />lar ym@atpeinc.com <br />11382 Q <br />�o�Fs`SIONALA Gl�ww <br />5/18/2023 <br />L.d <br />Ld p <br />L-L_ N <br />Li 00 <br />® <br />U � Q <br />0) <br />® j <br />>® W N <br />W <br />E <br />No. <br />Revision/Issue <br />Date <br />SD <br />Schematic Design <br />07-22-21 <br />DD <br />Design Development <br />08-11-21 <br />CD <br />Permit Set <br />10-22-21 <br />HVAC - <br />SCHEDULES <br />Project fl <br />Drawn <br />Sh- r. .. <br />21-012.0 <br />iC <br />M4.0 <br />Pr,"r Data <br />10-22-21 <br />Dne�LI <br />LM <br />sale <br />AS NOTED <br />