My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1702 COLBY AVE 2023-03-30
>
Address Records
>
COLBY AVE
>
1702
>
1702 COLBY AVE 2023-03-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2023 10:37:39 AM
Creation date
3/17/2023 1:46:06 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1702
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SOLGI-MN <br />P O W E R <br />January 26, 2023 <br />Subject: Proposed Solar Panel Installation <br />Edward Amato Residence, 1702 Colby Ave, Everett, WA <br />To Whom it May Concern, <br />Our engineering department has reviewed information, gathered by our field crews, related to the proposed solar <br />panel installation at the above -referenced address. The purpose of our review was to determine the structural <br />adequacy of the existing roof. Based on our review and analysis of the available information, and in accordance <br />with governing building codes, it is our professional opinion that the existing structure is permitted to remain <br />unaltered for the proposed solar installation. <br />Design Parameter Summary <br />Governing Building Code: 2018 Washington Building Code (2018 IBC) <br />Risk Category: II <br />Design Wind Speed: 110 mph (per ASCE 7-16) <br />Ground Snow Load: 15 psf <br />Roof Information <br />Roof Structure: 2x4 Rafters @ 24" O.C. <br />Roofing Material: Asphalt Shingles (1 layer) <br />Roof Slope: 30 degrees <br />Roof Connection Details <br />RT Minis into 2x rafters or truss top chords at 48" O.C.; install per design drawings and manufacturer specs <br />Locations per design drawings <br />Note: Required embedment length excludes the tapered tip of the screw, and embedment into sheathing. <br />Analysis <br />The proposed installation complies with the requirements of WAC Section 51-51-03240 R324.4 (Exception) and is <br />therefore deemed adequate to support the load of the rooftop solar system. <br />Specifically: 1) the system is designed for the local wind speed; 2) the ground snow load does not exceed 70 psf; 3) <br />the total dead load of all items is less than 4 psf (actual value is approximately2.74 psf); 4) Modules are not <br />mounted more than 18" off the roof; and 5) Supports are installed such that the dead load is spread across roof - <br />framing members and does not exceed 50 Ibs at any point. <br />Wind uplift on the panels has been calculated in accordance with the relevant provisions of ASCE 7-16. This loading <br />has been used to verify the adequacy of the connection specified above. Connection locations should be in <br />accordance with design drawings. <br />Conclusion <br />
The URL can be used to link to this page
Your browser does not support the video tag.