My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3700 FEDERAL AVE JACKSON ELEMENTARY 2023-04-06
>
Address Records
>
FEDERAL AVE
>
3700
>
JACKSON ELEMENTARY
>
3700 FEDERAL AVE JACKSON ELEMENTARY 2023-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 9:49:28 AM
Creation date
3/17/2023 1:52:05 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3700
Tenant Name
JACKSON ELEMENTARY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5104B Fire Control <br />Communicator <br />120VAC 60 Hz <br />Class A Input <br />(supervised) <br />Class B Inputs <br />(supervised) <br />Heat detectors, manual <br />pull stations and <br />contact type <br />smoke detectors <br />SILENT KNIGHT <br />MODEL 5104B <br />6 Channel Silent Knight <br />Communicator Model 5230 <br />(optional) <br />Model 6712 <br />12VDC 7 AH <br />Remote Annunciator <br />(3 max per system) <br />Tel. Line #1 <br />Tel. Line #2 <br />MODEL 5104B BLOCK DIAGRAM <br />To RJ31X <br />Stand-alone Automatic Fire Detection Application <br />(For Communication Only) <br />ARCHITECT/ENGINEER <br />SPECIFICATIONS <br />The contractor shall provide an <br />approved digital communicator to <br />transmit the fire alarm and supervisory <br />and trouble signals to a central station. <br />The digital communicator shall be UL <br />or FM listed for fire reporting to a <br />central station and shall conform to the <br />requirements of NFPA 72. <br />The digital communicator shall provide <br />power and necessary components for <br />six supervised detection circuits. One <br />shall be Class A (Style D) and five shall <br />be Class B (Style A). The detection <br />circuits shall accommodate sprinkler <br />flow switches, gate valve supervisory <br />switches, thermal detectors and <br />contact -type smoke detectors <br />intermixed as desired and permitted by <br />NFPA 72. <br />The control/communicator shall have <br />the capability to supervise two <br />telephone lines, seize the phone line <br />and send the alarm signal on one or <br />both lines without the addition of any <br />more equipment. It shall test each <br />telephone line (number) at alternating <br />24-hour intervals in accordance with <br />NFPA 72. It shall sound a local trouble <br />signal if the telephone service is <br />interrupted for longer than 60 seconds <br />and it shall transmit a signal indicating <br />the loss of phone line service to the <br />central station over the remaining <br />phone line. A signal shall also be <br />transmitted to indicate the restoral of <br />phone service. The <br />control/communicator shall be able to <br />report the loss of either phone line <br />without regard to which phone line <br />failed first. If both lines fail, a local <br />signal shall sound. <br />The control/communicator shall have <br />the ability to send a test signal to the <br />central station every 24 hours. The test <br />signal shall be able to be transmitted at <br />a specific time of day or night by <br />setting a program within the panel. <br />02 <br />I Wheelock <br />M13-G10-12-11 <br />(optional) <br />The digital communicator shall provide <br />a secondary power supply utilizing <br />rechargeable batteries. The secondary <br />supply shall be capable of supplying <br />power, under maximum normal load, <br />for 24 hours for central station or <br />proprietary applications or 60 hours for <br />remote supervising station system <br />application in accordance with NFPA <br />72. <br />The communicator shall be able to <br />transmit all signals in the Standard SIA <br />format (Security Industry Association). <br />The alarm signals transmitted to the <br />central station shall indicate which of <br />the six zones is in alarm and which <br />zones are in trouble. Restoral from <br />alarm or trouble shall be capable of <br />communicating to Silent Knight, and <br />other industry standard receivers. <br />SILENT This document is not intended to be used for installation purposes. We try to <br />KNIGHT keep our product information up-to-date and accurate. We cannot cover all <br />specific applications or anticipate all requirements. All specifications are <br />by Honeywell subject to change without notice. For more information, contact Silent Knight <br />12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, <br />Fax: (203) 484-7118. www.silentknight.com <br />h�IG1�7�1►I_1��t1�:7[HG1 <br />PN 350349, Rev C1 <br />©2010 Honeywell International Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.