Laserfiche WebLink
1.11 <br /> r Y <br /> 'i MyBui ldi ngPermit.com <br /> a service of eCityGov.net Construction Tip Sheet 10 <br /> Window Wells in Conjunction with Emergency Escape and Rescue Openings <br /> ❑ The horizontal area of the window well shall be not less than 9 square feet, with a horizontal <br /> projection and width not less than 36 inches. The area of the window well shall allow the <br /> emergency escape and rescue opening to be fully opened. (R310.3.2) <br /> D Window wells with a vertical depth greater than 44 inches shall be equipped with a permanently <br /> affixed ladder or steps useable with the emergency escape and rescue opening in the fully <br /> opened position and shall not encroach into the required dimensions of the window well. <br /> (R310.3.2.2) <br /> ❑ Ladder rungs or steps shall have an inside width of not less than 12 inches, shall project not <br /> less than 3 inches from the wall, and be spaced not more than 18 inches on center vertically for <br /> the full height of the window well. (R310.3.2.2) <br /> Minimum 36"x36" <br /> m <br /> Min 3"projection co <br /> .c from wait ; a 0 <br /> — <br /> c 4 „... ji 4 Max 18"0,C. <br /> li <br /> c co <br /> AS ax 18"0.C. E <br /> i ' <br /> Q' a m Min 3"projection <br /> t ` from wall <br /> Max 6"encroach into <br /> Q Minimum 36"x36" required window well <br /> "cifx i dimension <br /> January 24, 2021 MyBuildingPermit.com i Residential Emergency Egress Openings 2 <br /> eCityGov.net <br /> 2005 5 eCityGavAilianee <br />